Name of Work:- Supply, Installation, testing and Commissioning of 350mm, 250 mm & 1200mm Electromagnetic Flow Meter, Remote online monitoring instrument and V notch for Amthane Dam parameter monitoring
Sl. No.
Item Description
1
Supplying, installation, testing and Commissioning of 350mm Full Bore Carbon Steel Flanged ends Electromagnetic Flow Meter (FBEM) of Seimens/E&H/Yokogawa or equivalent makes to measure outflow to PWD as per the directions of the Engineer In-charge in complete, With the Below specifications:Nominal dia (mm): 350mm-Working pressure (kg/cm2):16-Working temperature: Remote PTFE – 180oC-Electrode material: SS 316L -Sensor lining: Std. Rubber-Display version: Remote-Measuring tube material: SS 304 -Sensor housing material: Std. CS-End connection: Flange-Flange standard: ANSI 150-Measuring range: 0.2 to 12 m/sec. Bidirectional-Accuracy % : ±0.5% (±O.2% consult factory)-Repeatability: ±0.2% of Span-Display: 2 line LCD-Display units: All standard engineering units in m3, litre, gallon, ft3-Output: Std. 4 – 20 mA/RS 485-Power supply: 12 – 60 V DC or 80 – 300 V AC/DC-Protection class for sensor: IP 67/68-Installation: Inline flanged typeThe output of the flowmeter coupled to a RTU for real time data monitoring via Mobile application and server, further compatible to existing departmental servers.Transmitter unit & Flow RTU-Installed near the remotely, and connected to the Flow sensor.-Ability to receive input from the sensor and convert input signals to readable data in M3/hr or LPS.-Physical Dimensions: 175 x 175 x 120 mm-Enclosure: ABS-Protection class : Weatherproof IP 65-Mounting: Field-Supply Power: 230 V A.C.-Display : 16 x 2 Alphanumeric display-Accuracy: ± 2% FSD-Input: 4-20 mA DC Current-Communication : Through built in GPRS modem-Data hosting via Mobile Application and PC-Data transferable incase of centralised sever facilities..
2
Supplying, installation, testing and Commissioning of 250mm Full Bore Carbon Steel Flanged ends Electromagnetic Flow Meter (FBEM) of Seimens/E&H/Yokogawa or equivalent makes to measure outflow to IDC as per the directions of the Engineer In-charge in complete, With the Below specifications:Nominal dia (mm): 250mm-Working pressure (kg/cm2):16-Working temperature: Remote PTFE – 180oC-Electrode material: SS 316L -Sensor lining: Std. Rubber-Display version: Remote-Measuring tube material: SS 304 -Sensor housing material: Std. CS-End connection: Flange-Flange standard: ANSI 150-Measuring range: 0.2 to 12 m/sec. Bidirectional-Accuracy % : ±0.5% (±O.2% consult factory)-Repeatability: ±0.2% of Span-Display: 2 line LCD-Display units: All standard engineering units in m3, litre, gallon, ft3-Output: Std. 4 – 20 mA/RS 485-Power supply: 12 – 60 V DC or 80 – 300 V AC/DC-Protection class for sensor: IP 67/68-Installation: Inline flanged typeThe output of the flowmeter coupled to a RTU for real time data monitoring via Mobile application and server, further compatible to existing departmental servers.Transmitter unit & Flow RTU-Installed near the remotely, and connected to the Flow sensor.-Ability to receive input from the sensor and convert input signals to readable data in M3/hr or LPS.-Physical Dimensions: 175 x 175 x 120 mm-Enclosure: ABS-Protection class : Weatherproof IP 65-Mounting: Field-Supply Power: 230 V A.C.-Display : 16 x 2 Alphanumeric display-Accuracy: ± 2% FSD-Input: 4-20 mA DC Current-Communication : Through built in GPRS modem-Data hosting via Mobile Application and PC-Data transferable incase of centralised sever facilities..
3
Supplying, installation, testing and Commissioning of 1200mm Full Bore Carbon Steel Flanged ends Electromagnetic Flow Meter (FBEM) of Seimens/E&H/Yokogawa or equivalent makes to measure outflow to Tillari Canal as per the directions of the Engineer In-charge in complete, With the Below specifications:Nominal dia (mm): 1200mm-Working pressure (kg/cm2):16-Working temperature: Remote PTFE – 180oC-Electrode material: SS 316L -Sensor lining: Std. Rubber-Display version: Remote-Measuring tube material: SS 304 -Sensor housing material: Std. CS-End connection: Flange-Flange standard: ANSI 150-Measuring range: 0.2 to 12 m/sec. Bidirectional-Accuracy % : ±0.5% (±O.2% consult factory)-Repeatability: ±0.2% of Span-Display: 2 line LCD-Display units: All standard engineering units in m3, litre, gallon, ft3-Output: Std. 4 – 20 mA/RS 485-Power supply: 12 – 60 V DC or 80 – 300 V AC/DC-Protection class for sensor: IP 67/68-Installation: Inline flanged typeThe output of the flowmeter coupled to a RTU for real time data monitoring via Mobile application and server, further compatible to existing departmental servers.Transmitter unit & Flow RTU-Installed near the remotely, and connected to the Flow sensor.-Ability to receive input from the sensor and convert input signals to readable data in M3/hr or LPS.-Physical Dimensions: 175 x 175 x 120 mm-Enclosure: ABS-Protection class : Weatherproof IP 65-Mounting: Field-Supply Power: 230 V A.C.-Display : 16 x 2 Alphanumeric display-Accuracy: ± 2% FSD-Input: 4-20 mA DC Current-Communication : Through built in GPRS modem-Data hosting via Mobile Application and PC-Data transferable incase of centralised sever facilities..
4
Supplying, installation, testing and commissioning of remote online montitoring for Exisiting 1000mm Flowmeter at Assonora WTPThe output of the flowmeter coupled to a RTU for real time data monitoring via Mobile application and server, further compatible to existing departmental servers.Transmitter unit & Flow RTU-Installed near the remotely, and connected to the Flow sensor.-Ability to receive input from the sensor and convert input signals to readable data in M3/hr or LPS.-Physical Dimensions: 175 x 175 x 120 mm-Enclosure: ABS-Protection class : Weatherproof IP 65-Mounting: Field-Supply Power: 230 V A.C.-Display : 16 x 2 Alphanumeric display-Accuracy: ± 2% FSD-Input: 4-20 mA DC Current-Communication : Through built in GPRS modem-Data hosting via Mobile Application and PC-Data transferable incase of centralised sever facilities..
5
V-NOTCH Water Seepage measurements(V-Notch) Proving and installation of stainless steel V- Notch’s including cost of civil work materials, including cost of all materials labour, HOM of machinery transportation, to site. The instrument shall conform to IS 7436 (Part 1) of Range 300mm of wc, resolution of 0.03%, Linearity of ±0.5% FS, Temperature limit of -10° to +60°C and material of stainless steel. Please Enable Macros to View BoQ information