| 1 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (a) Up to 35 Sq.mm/3.5 C |
| 2 | (b) Above 35 sq. mm and upto 95 sq. mm |
| 3 | (c) Above 95 sq. mm and upto 185 sq. mm |
| 4 | (d) Above 185 sq. mm and upto 400 sq. mm |
| 5 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.(a) Up to 35 Sq.mm/3.5 C |
| 6 | (b) Above 35 sq. mm and upto 95 sq. mm |
| 7 | (c) Above 95 sq. mm and upto 185 sq. mm |
| 8 | (d) Above 185 sq. mm and upto 400 sq. mm |
| 9 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.(a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 10 | (b) 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 11 | (c) 160 mm dia (OD-160 mm & ID-135 mm nominal) |
| 12 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.(a) Up to 35 Sq.mm/3.5 C |
| 13 | (b) Above 35 sq. mm and upto 95 sq. mm |
| 14 | (c) Above 95 sq. mm and upto 185 sq. mm |
| 15 | (d) Above 185 sq. mm and upto 400 sq. mm |
| 16 | Handling of PVC/PILCA/XLPE cables of Grade 1.1 KV which are not necessarily laid in ground but part of it going up to pole/panel/pillar & part in the building in open trench/ pillar/ panel or otherwise(a) Up to 95 Sq.mm/3.5 C |
| 17 | (b) LT cable above 95 sqmm/3.5C up to 400 sqmm/3.5 C |
| 18 | Dismantling/ laying of PVC/ PILCA/ XLPE cables of Grade 1.1 KV which are not necessarily laid in ground but part of it going up to pole/panel/pillar & part in the building in open trench/pillar/panel or otherwise(a) Up to 95 Sq.mm/3.5 C |
| 19 | (b) LT cable above 95 sqmm/3.5C up to 400 sqmm/3.5 C |
| 20 | Road cut of any thickness (metalled/concrete) for one cable |
| 21 | Road berm/stone footpath/brick footpath/C.C. Slab/ Approach Gate |
| 22 | Road cut of any thickness (metalled/concrete) for additional cable(a) Service Road |
| 23 | (b) Road berm/stone footpath/brick footpath/C.C. Slab/ Approach Gate Please Enable Macros to View BoQ information |