| 1 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil. 300 mm dia |
| 2 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil. 300 mm dia |
| 3 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 4 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 5 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in- charge. |
| 6 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 7 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 8 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65 mm dia nominal bore |
| 9 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 150 metre & upto 250 metre depth below ground level. |
| 10 | Supplying, assembling, lowering and fixing in vertical position in bore well, heavy well casing M. S. pipe of required dia including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia |
| 11 | Supplying, assembling, lowering and fixing in vertical position in bore well, heavy well screen M. S. pipes with ribs including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia |
| 12 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia |
| 13 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp |
| 14 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia |
| 15 | Conducting Geophysical & Hydrogeological Survey to Select Suitable Borewell Point by using Fresh Result Instrument (GER DETECT) and PQWT. |
| 16 | Modified total by multiply correction factor of 0.973 ON TOTAL AMOUNT (SL NO 1 TO 8) |
| 17 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mmdia including accessories, and providing masonryenclosure with cover plate having lockingarrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 18 | Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 19 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 20 | Providing and making end termination with brass Compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV Grade as required 3.x50 sqmm(35 mm) |
| 21 | Providing and Fixing of 65 mm dia cast iron non returning valve swing check type in existing 65 mm dia outlet delivery pipe. Make and specification of isi mark only. |
| 22 | Providing, installation, testing and commissioning of ISI Marked vertical 20 HP with minimum 16 stage outlet deleivery size 65 mm sumbersible pump set with motor content with shaft and cast iron/ss body, the pump shall be designed to prevent over loading and having dynamically balanced rotating parts etc. the pump capable of delivering following capacities discharge at suitable for operation on 415 volt(+/- 10%) 3 Phase AC Supply, i/c providing required nos of MS Clamp made on flat iron and suitable size top cover made of suitable thick MS Sheet as required with outlet deleivery size 65 mm, material of motor body/pump, warranty 12 months, suitable bore well depth approx 450 to 500 feet for cashing pipe dia meter 200 mm i/c lowering of pump set in the existing bore well and making connection etc. as required(Make Havells/LK/Crompton/Lubi/Kirloskar) |
| 23 | Providing and Fixing of PVC insulated PVC Sheathed copper conductor sumbersible flat cable ISI Marked in the existing metal/HDPE/PVC/Pipe/ in bore well/ in sump i/c fixing the cable to GI/HDPE Pipe with suitable cable tags follwing sizes ets as required 3 Core 16 Sqmm Flat cable (Havells/polycab/KEI/LK) |
| 24 | Supplying and fixing of GI Pipe(lowering pipe) of 65 mm dia heavy duty(Class C) ISI Marked in the existing borewell for lifting of water 20 HP Sumbersible Pump+Motor to surface i/c making connection testing etc. as required as per direction of Engineer in charge with the following accessoires fitted (i) pipe length - 06 mtr of each (ii) GI threaded flange - welded at both side with 04 holes (iii) suitable nut bolts 04 nos each side (iv) full face rubber gasket - 02 Nos with 4 holes, pipe Make TATA/Prakash/Jindal/Ravindra/Hindustan. |
| 25 | Providing and Fixing of steel rope (safety guard wire) of grade with following specifications for support of sumbersible pump+motor i/c connection at both end in the borewell etc as required (i) minimum wire dia 10 mm (ii) wire coating- nylon or PVC Coated and as required of ISI Mark only |
| 26 | Supplying & laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size 3.5 x 50 sqmm direct in ground i/c excavation and refilling the trench etc as required but excluding sand cushioning and protective covering of make Havells / Polycab / finolex / Gloster/ISI Mark cable only |
| 27 | Supplying & laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size 3.5 x 50 sqmm. in the existing masonry open duct as required. Conf. to IS:7098 part - I of make Havells / Polycab / finolex / Gloster/ISI Mark cable only |
| 28 | Fabrication, Providing, installation, testing and commissioning of outdoor type feeder piller, double door made out of 2.0 mm thick CRCA powered coated sheet of size 900 mm(height) x 900 mm (width) x 450 mm deep having 200 amp 04 Nos aluminum bus bar, and to accommodate with following accessories, front & back openable door, RYB LED indicators, and P & F of internal connections with suitable size of copper wires, following acceossires & angle iron frame of size 900 mm x 450 mm with 800 mm long legs made out of 40 mm x 40 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming & outgoing cables, cable termination, earthing, locking, interconnection etc. as required ( CPRI Approved builder) :-(a) 100 amp, 4 Pole, 415 volt 50 Hz MCCB , Make Havells/Standared/LK/Siemns/ABB make - 1 No.(b) Indicating lamp (LED Type) 230 volt, RYB - 03 Nos(b) Submarssible pump starter (Star-Delta) with phase preventer for 3 Phase submersible pump set as item no. 5, Make Havells - 1 No. or similiar specifications of LK/Crompton/C&S/HPL/Protex |
| 29 | Total Cost (BoQ1+BoQ2) |
| 30 | Civil work |
| 31 | Elect work Please Enable Macros to View BoQ information |