| 1 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 2 | 1 or 2 Module (75mmX75mm) |
| 3 | 6 Moudle (200mmX75mm) |
| 4 | 8 Module (125mmX125mm) |
| 5 | 12 Module (200mmX150mm) |
| 6 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 7 | Group C |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 9 | 5/6 A switch |
| 10 | 3 pin 5/6 A socket outlet |
| 11 | 15/16 A switch |
| 12 | 6 pin 15/16 A socket outlet |
| 13 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 14 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \\"C\\" curve including connections, painting etc. as required. |
| 15 | Supply and fixing of suitable size G.I. box with modular plate and cover on front or surface in recess including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16A modular switch, connection etc.as required. |
| 16 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 17 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 18 | Group C |
| 19 | Supplying and fixing of following sizes of heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 20 | 20 mm |
| 21 | 25 mm |
| 22 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 23 | 4X10 sq. mm + 2X 6 sq. mm earth wire |
| 24 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 25 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 26 | 12 way (4 + 36), Double door |
| 27 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 28 | Single pole |
| 29 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 30 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 31 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 32 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 33 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 34 | Upto 35 sq. mm |
| 35 | Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 36 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 37 | 3x2.5 sq.mm |
| 38 | 3x4 sq.mm |
| 39 | 3x6 sq.mm |
| 40 | Supply, Installation, testing and commissioning of pre-wired, Double box fitting with Two no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 2xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 41 | Supply, Installation, testing and commissioning of one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm in existing single box or double box fittings complete as required. Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 42 | Supply, Installation, testing and commissioning of pre wired 2'x2' recess mounted 36 watts LED fitting square shape, Commercial grade with luminaire with diffuser complete with all accessories i/c connection with 1.5 sqmm FRLS PVC copper conductor Cable with mounting 4 nos clutch wire /G.I. chain for mounting from true ceiling etc. as required. Make Philips, Model No. - FullGlow G6 Cat No. RC380B LED36S-6500 G6 L60W60 PSU OD S1 or equivalent model of Thorn/Trilux |
| 43 | Supply, Installation,testing and comissioning of Plastic body exhaust fan of 200 mm sweep, suitable for operation on 230 Volt, 50 Hz,single phase, AC supply, 1585 RPM, with air delivery of minimum 700 CMH in the existing opening, including, making good the damage, connection with suitable size cable, testing and commissioning etc. as required.Make Crompton greaves model- Ventilus HS exhaust fan or equivalent model of Almonard/Atomberg. |
| 44 | Supplying and Fixing of snap-on DLP trunking of size 105mm x 50 mm with cover and including accessories such as Flat angle, end caps, internal/external angle support etc. on the wall/surface complete all as requied. |
| 45 | Supply and fixing of street light pole box of size (250 X 200 X 100) complete with all necessary accessories including suitable clamps, bakelite sheet, brass screws, washers, and 01 no. 10 Amps SP MCB (Single Pole Miniature Circuit Breaker), inclusive of making electrical connections, as required at site. |
| 46 | Supply, installation, testing and commissioning of pre-wired, 150 watt, Flood light Pressure die-cast aluminium housing with high impact resistance (IK07) glass cover IP 66 protection, 130 lm/w, 220-240 V, 50 Hz on existing street light pole/wall including all accessories and connection etc as required. (Philips make, Cat no. BVP 192 LED 177 CW NB FG A1 PSU GR or equivalent Model of Thorn/Trilux). |
| 47 | Dismantling of ceiling fan/exhaust fan/Light fittings etc. including disconnection of wires/cable and submission of same in department store etc. complete as required. |
| 48 | Supplying of one number PVC insulated and PVC sheathed / XLPE aluminium conductor armoured power cable of 1.1 KV grade of size 4C x 16 sqmm etc as required. Please Enable Macros to View BoQ information |