| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas including getting out and disposal of excavated earth in all leads and lifts, as directed by Engineer-in-charge. All Kind of soils. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains , including dressing of sides and ramming of bottoms,in all lift , including getting out the excavated soil and disposal of surplus excavated soil as directed in all leads & lifts. All kind of soils |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering including carriage of material in all leads and lifts. 1:4:8 (1 cement : 4 fine sand : 8 graded stone aggregate 40 mm nominal size) All work up to plinth. |
| 4 | Providing and laying cement concrete 1:5:10 (1 cement : 4 fine sand : 8 graded stone aggregate 40 mm nominal size) and curing complete including the cost of formwork for plain/reinforced concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc i/c weephole as per technical specifications including carriage of material in all leads and lifts. |
| 5 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing including carriage of material in all leads and lifts. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 6 | Providing weapholes in brick masonry / stone masonry /plain reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full with of the structures with slope of 1(v):20(H) towards drawing face complete as per drawing and technical specificatioclauses 614, 709, 1204.3.7 including carriage of material in all lead and lift. |
| 7 | Stone filling behind retaining walls including carriage of material in all leads and lifts. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for all heights including carriage of material in all leads and lifts. |
| 9 | Foundations, footings, bases of columns, etc. for mass concrete |
| 10 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 11 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length i/c holdfast complete in all respects including carriage of material in all leads and lifts. Sal wood |
| 12 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters including carriage of material in all leads and lifts. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 13 | Providing and fixing panelled or panelled and glazed shutters for windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Kiln seasoned and chemically treated hollock wood including carriage of material in all leads and lifts. 30 mm thick shutters |
| 14 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete including carriage of material in all leads and lifts. 250x16 mm |
| 15 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete including carriage of material in all leads and lifts. 300x10mm |
| 16 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete including carriage of material in all leads and lifts. 200x10 mm |
| 17 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete including carriage of material in all leads and lifts. 125mm |
| 18 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, railing, window frame etc including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including carriage of material in all leads and lifts. |
| 19 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including carriage of material in all leads and lifts. |
| 20 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge including carriage of material in all leads and lifts. Made of G.I. wire of dia 4 mm |
| 21 | Providing & fixing glass panes with putty/beading and glazing clips in windows, clerestory windows, all complete including carriage of material in all leads and lifts. 4.0 mm thick glass panes |
| 22 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required including carriage of material in all leads and lifts. |
| 23 | Providing and laying 10mm thick vitrified floor, dado tiles in different sizes with water absorption less than 0.08%, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete including carriage of material in all leads and lifts. |
| 24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete including carriage of material in all leads and lifts. |
| 25 | Finishing with Deluxe Multi surface paint system for interiors and exteriors as per manufacturers specifications including carriage of material in all leads and lifts.Two or more coats applied on walls @ 1.25 ltr/10 sqm of approved brand and manufacture |
| 26 | Painting wood work with Deluxe Multi Surface Paint of required shade including carriage of material in all leads and lifts. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 27 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade including carriage of material in all leads and lifts. Two or more coat applied @ 0.90 ltr/10 sqm of approved brand and manufacture |
| 28 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) including carriage of material in all leads and lifts. |
| 29 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) including carriage of material in all leads and lifts. Please Enable Macros to View BoQ information |