| 1 | Excavation in foundation and trenches ( For pipes and pits ) up to all depths in all classification of earth work such as pick work ,jumper work ,saturated soil including bailing or pumping out water ,blasting soft/hard rock or chiseling soft/hard rock where blasting is prohibited in all lifts including trimming & dressing of sides, leveling of beds to correct grade i/c shoring /strutting ,planking ,timbering & dewatering wherever required ,stacking the usable & unusable material /soil separately & after laying ,jointing & testing of pipes ,returning the useable soil in trenches in 15 cm ,layers including consolidating of such deposited layer by ramming & watering & then deposing of all surplus excavated soil / unusable material as directed with in all leads and lifts including restoration of unmetalled surfaces to its original condition and including cost of diversion for traffic , night signals ,fixing caution boards ,crossing over trenches for access to houses ,fencing etc. complete in all respects with in all lead and lifts as per direction & satisfaction of Engineer - in - charge. |
| 2 | Dismantaling of Galvanised Mild Steel Tubes (LG) including fittings (earth work in trenches to be measured and paid separately ) as per direction and satisfaction of engineer in charge of the following nominal bore. |
| 3 | 50mm Dia |
| 4 | 40mm Dia |
| 5 | Relaying Jointing and Testing of Galvanised Mild Steel Tubes (LG) including fittings ( earth work in trenches to be measured and paid separately ) as per direction and satisfaction of engineer in charge of the following nominal bore. |
| 6 | 50mm Dia |
| 7 | 40mm Dia |
| 8 | Providing Laying, Jointing and Testing of Galvanised Mild Steel Tubes (LG) including fittings (earth work in trenches to be measured and paid separately) as per direction and satisfaction of engineer in charge of the following nominal bore. |
| 9 | 50mm Dia |
| 10 | 40mm Dia |
| 11 | Providing and fixing GI Sockets heavy duty ISI marked complete fixing at site complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 12 | 50mm Dia |
| 13 | 40mm Dia |
| 14 | 32mm Dia |
| 15 | Providing and fixing GI unions heavy duty ISI marked complete fixing at site complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 16 | 50mm Dia |
| 17 | 40mm Dia |
| 18 | 32mm Dia |
| 19 | Providing and fixing of Bir/ Kartar make Cast Iron Double flanged Sluice Valve of class-ASA 150 as per relavant IS standards withstand nominal seat pressure 20.00 KG/Cm sqr. Conforming to IS BS :1868/API -600(latest with up to date ammendments if any ) complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge having following nominal diameters: |
| 20 | 50mm Dia |
| 21 | Providing and laying cement concrete 1:3:6 (1 cement:3 sand:6 graded stone aggregate 40mm nominal size) and curing complete excluding cost for form work in foundation and plinth with in all leads and lifts. |
| 22 | Providing and laying cement concrete 1:2:4(1 cement:2 sand:4 graded stone aggregate 20mm nominal size) and curing complete excluding cost for form work in:- |
| 23 | Foundation and plinth with in all leads and lifts. |
| 24 | Wall(any thickness but not less than 0.10mtr thickness attached pillasters, buttresses, plinth anddrting courses etc from top foundation level upto floor level including entire carriage of material with in all angle iron 30x30x5 mm so as to give a fair finish including cenetring, shuttering, strittingand proping etc. with wooden batten and ballies height of proping and centring below supporting floor to ceiling not exceeding 4 mtr and removel of the same for insitu reinforcement concrete and plain concrete work in vertical surface such as wall(any thickness)partitions and the like including pillasters, buttresses plinth and string course and the like including entire carriage of materials with in all leads and lifts. |
| 25 | Suspended floors, roofs, landings and shelves and their supports, balconies, beams ,griders bressumers and cantilevers upto all floor level with in all lead and lifts. |
| 26 | Providing Form work with steel plattes 3.15 mm thick welded with angle iron30x30x5mm so as to give afair finsh including centering, shuttering,strittingand proping etc.with wooden batten and ballies height of proping and centering below supporting floor to celling not concrete and plan concrete work in:- |
| 27 | Flat surfaces such as soffits of suspended floors, roofs, landings and the like floors upto 200 mm kin thickness. |
| 28 | Vertical surface such as wall(any thickness) partitions and the like including pillasters,buttresses plinth and string course and the like including entire carriage of materials with in all leads and lifts Providing Tor steel reinforcement for RCC work including bending. |
| 29 | Edges of slabs breaks etc under 20 cm wide |
| 30 | Providing TOR steel reinforcement for RCC work including bending binding and placing complete upto floor two level complete in all leads and lifts. |
| 31 | Providing and fixing of oil immersed star delta starter 45 HP of MEI/Kilburn make of following ratings including initial oil filling and cost of making all connection with theimbles of required ratings and carriage upto site of work complete with in all leads and lifts as per entire satisfaction of the Engineer-in-Charge. |
| 32 | Excavation in earth work and banking in 20 cm layers including breaking clods, ramming and dressing up for the purpose of making embankments of filling up ground depressions up to all leads and lifts in pick work (Local earth) |
| 33 | Providing and laying cement concrete 1:6:12 (1Cement:6sand:12 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work foundation and plinth . |
| 34 | Providing and fixing Heavy duty compacted and pressed C.C.interlocking paver blocks 60mm thick complete in all respects within all leads and lifts as per direction and complete satisfaction of engineer in charge. |
| 35 | Disjointing , Dismantling RCC Pipe of following dia class NP-2 including cost of stacking of pipe on the site, Disjointing of joints complete in all respect. |
| 36 | RCC Pipe 250 mm dia |
| 37 | Relaying/ Rejointing dismantled RCC pipe of following dia class NP-2 after removing the blockage including cost of new Joints, rubber gasket and testing complete in all respect. |
| 38 | RCC Pipe 250 mm dia |
| 39 | Providing Laying Jointing & testing reinforced cement concrete light duty non pressure pipe Class NP-2suitable class and spigotted and socketted end type precast reinforced concrete pipe of following internal dia meter including testing of joints complete confirming to IS 458-2003 or latest with upto date amendments complete with rubber ring type II duly ISI marked as per IS:5382 -1985 or latest with uptodate ammendments and filling of joints in cement mortar 1:2 (1: Cement :2 Sand) with in all leads and lifts as per direction of the Engineer-in-Charge.and testing of joints and laying shuld be as per IS 783-1985 or latest with up to date ammendments with in all leads and lifts as per direction and satisfaction of the Engineer-in-Charge. |
| 40 | RCC Pipe 250 mm dia |
| 41 | Providing & fixing of cast iron alfa valves of following dia within all leads and lifts as per the direction of Engineer-in-charge. |
| 42 | Brick work using common burnt clay building bricks(2nd class in super structure, pillars etc above and below plinth levels upto floor two levels in ceent mortar 1:6 (1 cement : 6 sand) with in all leads and lifts as per direction and complete satisfaction of Engineer in charge. |
| 43 | 20 mm cement plaster in single coat of rough sides of bricks/concrete stone walls for interior plastering upto floor two level including arrises internal rounded angle chambers and rounded angles not exceeding 80 mm in girth and finshed even and smooth in cement mortar 1:6 (1 cement :6 sand) in all leads and lifts. |
| 44 | 20 mm thick cement concrete topping in 1:2 to 3 (1 cement : 2 to 3 sand complete in all respect with in all leads and lifts. |
| 45 | Providing and Fixing of fencing panels of size 1.20x1.80 or jali 25x25mm welded to MS black tube of 32 mm dia of 14 guage with MS flat 20x3 mm , MS holdfast 7 nos. Made of MS flat 32x 3 mm including cutting welding painting with red oxide paint complte in all respects . The jali of 25x25 mm should be fixed in 1.20x1.80 mtr. and work should be executed within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 46 | Finishing wall with water proofing cement paint of approved brand & manufacture & of required shade on undecorated wall surfaces (two coats) to give an even shade after thotoughly brushing the surface to remove all dirt & remains of loose powdered materials. |
| 47 | Applying priming coat over new steel and other metal surfaces after including preparing the surface by thoroughly cleaning oiling, greasing, dirt and dust and other forging matter and sourced with wire brushing fine steel wool scraps and sand paper complete with ready mixed priming paint brushing red laid, Red oxide / Zinc oxide chrome. |
| 48 | Painting two coats (excluding priming coat)on new Steel and Steel based surface with ready mixed paint brushibng the give and even shade including cleaning of all dirt dust and other foreign matter and sand papering and stopping with ready mixed paint other than white in all leads and lifts. |
| 49 | Demolishing RCC work manually/ by mechanical means including stacking of serviceable material and disposal of unseviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 50 | Demolition of old 20 mm thick plaster in C.M. 1:6 ( 1 cement : 6 sand ) including disposal of the waste material with in all leads and lifts complete in all respect as per entire satisfaction of Engineer in charge. |
| 51 | Demolition of cement concrete in flooring in 1:2:4 (1 cement :2 sand :4 aggregate) including disposal of the waste material complete in all respect as per entire satisfactionn of Engineer in charge. |
| 52 | Cement concrete in flooring in 1:2:4(1 cement :2 sand :4 aggregate) complete in all respect as per entire satisfactionn of Engineer in charge. |
| 53 | 6 mm thick ceiling plaster in C.M. 1:3 ( 1 cement : 3 sand )in all leads and lifts complete in all respect as per entire satisfaction of Enginer in charge. |
| 54 | Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size and including finshing the top surface of concrete smooth. |
| 55 | Distempering with dry distemper of approved brand and manufacturer( Two coat and of required shade on undercoated wall surface to give an even shade over and including primer coat of whiting after thoroughly brushing the surface free from mortar dropping and other foreign matter including preparing the surface even and sand papered smooth. |
| 56 | Painting two coats(excluding priming coat) on new wood and wood based surface with ready mixed paint brushing the give and even shade including cleaning of all dirt dust and other foreign matter and sand papering and stopping with ready mixed paint other than white. |
| 57 | Providing and fixing M.S. fan clamp 16 mm dia M.S. bar bent to \\"U\\" shape with hooked ends in R.C.C. slab during laying including painting the exposed of loop all as per standard design complete. |
| 58 | Providing and fixing PVC pipe 80 mm dia with clamps for safe disposal of rain water from roof complete in all respect as per entire satisfaction of Engineer in charge. |
| 59 | Providing and fixing PVC bend 80 mm dia complete in all respect as per entire satisfaction of Engineer in charge. |
| 60 | Providing and fixing PVC Socket 80 mm dia complete in all respect as per entire satisfaction of Engineer in charge. |
| 61 | Wiring for sub main wiring with following sizes of PVC insulated conductor single core cable in surface /recessed PVC conduit as required (2.5 sqmm) of finolex /plaza or some ISI make approved make by HPSEB Department complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 62 | Wiring for sub main wiring with following sizes of PVC insulated conductor single core cable in surface /recessed PVC conduit as required (1.00 sqmm) of finolex /plaza or some ISI make approved make by HPSEB Department complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 63 | Providing and fixing holder for bulbs Anchor/Havells/Syska make complete in all respect as per entire satisfaction of Engineer in charge. |
| 64 | Providing and fixing round electrical fan sheet complete in all respect as per entire satisfaction of Engineer in charge. |
| 65 | Providing and fixing round electrical holder sheet complete in all respect as per entire satisfaction of Engineer in charge. |
| 66 | Providing installation and commissioning and testing of of LED bulbs 20 watts fittings including 90 degree GI bend choke reflector of Bajaj /crompton /Greaves make complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 67 | Providing fixing testing and comissioning of ceiling fan 1200 mm(category - A ) and regulator including wiring of the down rod of standard length (up to 30 cm) with 1.5 sqmm PVC insulated copper conductor single core cable etc. as required complete in all respects as per direction and satisfaction of engineer in charge complete in all respects. |
| 68 | Providing and fixing LED street lights 40 watt 110-220 V with complete fixtures including cost of providing and commissioning of electric wire as per required length ISI approved, Flexible pipe to cover the electric wire Havells/L&T/Philips/Syska make and making connection to existing electric syestem as per entire satisfaction of Engineer in charge. |
| 69 | Providing & fixing 3 pin socketoutlet on the existing switch box/cover including connection etc. as required complete in all respects as per direction and satisfaction of engineer in charge complete in all respects. |
| 70 | 5/6 Ampere |
| 71 | 15/16 Ampere |
| 72 | Supplying and fixing of wooden box 50mm deep on surface or in recessed with suitable size pharolic sheets laminated in front including providing and fixing 3 pin 5/6 ampere socket outlet and 5/6 amp. Tumbler / piano type switch connection painting as required (for power plug) complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 73 | 200 mm x 120 mm |
| 74 | 120 mm x 120 mm Please Enable Macros to View BoQ information |