| 1 | Cleaning of existing sewer lines of dia 100 to 300 mm, any depth not exceeding 2.50 m deep by rodding manually or mechanically as required at site including manholes, inspection chamber, testinig after cleaning and getting out sludge and accumulated solids / semi solids from connecting manholes / lines, removing the sludge / spoil min 250 mtrs away from MoD land and refixing the manhole cover etc complete all as specified. |
| 2 | Cleaning/desludging of existing septic tanks of any capacity and any depth including taking out and removing sludge and accumulated solids / semi solid contents out side defence land in closed container more than to a pit of sufficient size and depth at a place 250 mtrs away from defence land and burried in ground including necessary excavacution, earth work and spreading of bleaching powder complete all as specified and directed. |
| 3 | Cleaning/clearing of manhole of any description and any size varying from 0.6 x 0.60m to 1.50 x1.50 mtr having depth varying from 0.4 mtr to 2.5m and removing sludge and accumulated solid/semi solids with proper equipment and washing down with water for smooth functioning of sewage line and manhole all as specified and directed. Waste obtained shall be removed to a distance exceeding 250m away from unit lines and burried in ground including necessary excavation, earth work and spreading of bleaching powder complete all as specified and directed. |
| 4 | Cleaning / clearing of blocked WC / EWC of any type and description including removal of soil, waste and vent pipes by using rubber cup 125mm dia with wooden handle, rodding or with gunny bags and clearing the blockage upto 1st manhole with cleaning rod including removal of all materials from traps of WC complete all as specified and directed. |
| 5 | Cleaning / Clearing of Nahani traps, floor traps and Gully traps of any description, any size any depth and removing sludge and accumaulated solid / semi solis with proper equipment and washing down with water for smooth functioning of sewage line, nahani traps and floor traps all as specified and directed. Waste obtained shall be removed to a distance exceeding 250m away from unit lines and burried in ground including necessary excavation, earth work and spreading of bleaching powder complete all as specified and directed. |
| 6 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, manholes etc not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified and as directed |
| 7 | Demolition and breaking up drain pipes , 100/110 mm dia (PVC / Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar or fixed with wall complete all as specified and directed. |
| 8 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) complete all as specified and directed. |
| 9 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil of any description, complete all as specified and as directed.. |
| 10 | Removing excavated soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.5m above the starting point, complete all as specified. |
| 11 | M&L for PCC 1:4:8 type D-2, (Using 20 mm graded stone aggregate) as in bed of drain for 100mm bore pipe incl packing under and haunching against the sides of pipes after they are laid in and tested complete all as specified and directed. |
| 12 | S&F PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed |
| 13 | Demolition of reinforced cement concrete cover slab for MH/Spetic tank and removing the debris to a distance not exc 500 M as directed. |
| 14 | M & L precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate for cover slab for Man holes/Septic tank set in CM 1:4 complete all as specified and directed. |
| 15 | M&L for mild steel deformed bars or TMT bars10mm dia and over, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 16 | M&L for mild steel deformed bars or TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 17 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 18 | Pre - cast cement concrete 1:3:6 type C-1, (20mm graded stone aggregate) block masonary with solid blocks built in cement mortar 1:6 complete all as specified and as directed |
| 19 | M&L for walling of random rubble stone masonry uncourced well bonded bedded and solidly hearted built in CM 1:6 complete all as specified and as directed |
| 20 | M&L precast PCC 1:3:6 type C1 using 20mm graded stone agg as bond stones set in cement mortar 1:6 complete all as specified and as directed |
| 21 | M&L PCC 1:2:4 type B-1 using 20mm graded stone agg as in coping to retaining wall / drains / manholes complete all as specified and directed. |
| 22 | Taking down cement plastering at any description on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc and removal of debries and depositing where directed. |
| 23 | M&L for Rendering 15mm thick on stone masonary surfaces in CM 1:4 finishing even and smooth without using extra cement complete all as specified and directed. |
| 24 | M & L rendering 15mm thick on fair faces of stone/concrete work in CM 1:4 incl finished even and smooth without using extra cement. |
| 25 | M&L for PCC 1:2:4 type B-2 (using 40mm graded stone agg) as in surface channel, drain and manhole including finishing complete all as specified and directed. |
| 26 | M/L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in fdn filling and mass concretecomplete all as specified and directed. |
| 27 | Extra for forming fair finished drain channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 28 | Supply and fixed (in repairs) vitreous China squatting pan of Orrisa pattern size 580mmx440mm white (Ist quality) with ‘P’ or ’S’ trap, front or back inlet and integral foot rests of any pattern complete including making good to floor surface with the existing surface and connection to flush pipe complete all as specified. |
| 29 | Material and labour for 40mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in floor finished even and smooth without using extra cement complete all as specified and directed . |
| 30 | S&F 110mm dia PVC pipe single socketed, in any length with rubber rings joints or jointed with solvent cement joint, fixed to wall, complete all as specified and directed. |
| 31 | S&F in repair PVC (SWR) vent cowl 110mm dia pipe complete all as specified and directed. |
| 32 | S&F in repair PVC (SWR) vent cowl 75mm dia pipe complete all as specified and directed. |
| 33 | Schedule of Credit Please Enable Macros to View BoQ information |