| 1 | Schedule 'A' |
| 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, poles struts, laying of cables/pipes, etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 3 | All as per item No.1.01 but beyond 1.5 m depth complete all as specified and directed. |
| 4 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and as directed. |
| 5 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soils complete all as specified and as directed. |
| 6 | Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down 18CM will be measured and paid complete all as specified and directed.(Note: Thickness of sand cushion after punning down will be measured and paid.) |
| 7 | Supply and laying well burnt sub class ‘B’ bricks ( designated 75) locally available best quality, laid dry in trenches for protection of underground cable all as specified and directed. |
| 8 | Supply and fixing in repairs of steel tubular swaged poles, type 410 SP 31 (Overall length 9.00 m) complete with cast iron base plate, finial taper plug, bolts, nuts screws and washers including painting two coats of black bituminous paint internally and externally up to planting depth and remaining external portion with two coats of aluminum paints over a coat of red oxide primer and writing pole Nos with white paint on black back ground complete all as specified and as directed. |
| 9 | M&L for plain cement concrete 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundation of pole, protection of UG cable, concrete base, etc complete all as specified and directed. |
| 10 | M&L for plain cement concrete (1:3:6) type C0 using 12.5 mm graded crushed stone aggregate in coping of pole, concrete base work, protection of cable complete all as specified and directed. |
| 11 | M&L for stringing ACSR conductor in repairs of any size including all binding wires and aluminium jointing, jumpering etc maintaining standard sag on LT OH lines complete all as specified and directed. |
| 12 | S&F in repairs for cross arms, bracing, clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, drilling hole for bolts in any shape or size with welding, bending cold or hot including painting two coats of aluminium paint over a coat of primer complete all as specified and directed. |
| 13 | S&F in repairs pin type porcelain insulator of size 100 mm height, 65mm dia, vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut for 1100 volts grade complete all as specified as directed. |
| 14 | S&F in repairs shackle type insulator, porcelain, vitreous, white, brown or green, 75 mm height 90 mm dia for working pressure of 1100 volts including galvanized steel straps of section 31x3 mm, 12 mm dia of bolts, washers and nuts complete all as specified and directed. |
| 15 | Supply, laying, Jointing connecting in repairs of LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core laid in trenches / on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. |
| 16 | All as per serial item No. 14 above but for 10 Sqmm 4 Core. |
| 17 | All as per serial item No. 14 above but for 16 Sqmm 4 Core. |
| 18 | Supply and laying in repairs of GI tube 40 mm bore medium grade as in cable protection pipe including all fittings & taking down / taking out from trench complete all as directed |
| 19 | Material and labour for cutting of road/ hard standing n exc 20cm width and n exc 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 to match with existing surface complete all as directed. |
| 20 | Supply & Fix in repairs bracket made of 32/40 mm bore galvanised iron light grade pipe made to shape having overall length 1.2 mtr, fixed on pole /wall through two numbers mild steel clamp of 25mm width 3mm thick MS flat strip and four Nos nuts ,bolts & washers complete all as specified and as directed. |
| 21 | Supply & Fix in repairs LED street light fitting 60Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 22 | Supply & Fix in repairs LED street light with motion sensor fitting 60 Watt 230 V AC outdoor type with auto on-off or Dimming/ Brightness, high pressure die cast aluminum hosing and heat resistant complete with driver, lithium ion battery for minimum 6 hrs backup, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified and directed. |
| 23 | Supply & Fix in repairs inverter LED street light fitting 60 Watt outdoor type with high pressure die cast aluminum hosing, inbuilt battery back-up, real time clock (RTC) auto on-off/ Dimming (pre-programmable) and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 24 | Supply & Fix in repairs All-in-one LED solar street light fitting 25/30 Watt outdoor type with inbuilt lithium ion battery of minimum 18 AH, PV Panel power minimum 15 watt, high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 25 | Supply & Fix in repair post top lantern LED type 20Watt 230volts AC outdoor type with decorative post top for 360 degree energy saving, environmental friendly, long life aesthetically designed IP 65 protection including impact corrosion resistant connection with twin core twisted flexible copper conductor cable complete all as specified and as directed. Make:- CG Catt Part No LPTH-20-WW or equivalent. |
| 26 | Supply & Fix in repair Globe Light 10 Watt 230 volts AC outdoor type including lamp with twin core twisted flexible copper conductor cable complete all as specified and as directed. |
| 27 | Supply & Fix in repair robustly designed IP 65 LED bollard light fitting 8/10W ,220- 240V with minimum upward light component, ensuring excelent distribution and high system lumen efficency and incl easy to install with base plate necessary connection complet all as specified & directed . Make:- CG Cat Part No LBLA3-10-WW or equivalent. |
| 28 | Supply & Fix in repair LED flood light 100 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and incl eassy to instl with base plate connection complete all as specified and directed. |
| 29 | Supply & Fix in repair LED flood light 120 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and incl eassy to instl with base plate connection complete all as specified and directed. |
| 30 | Supply & Fix in repair LED flood light 60/70 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and incl eassy to instl with base plate connection complete all as specified and directed. |
| 31 | Supply & Fix in repair inverter LED flood light 60 watt 230V AC outdoor type with pressure die cast aluminum hosing thermal management in multiple optics and equipped with battery back-up of minimum 6 hrs, IP66 protection, with impact and corrosion resistant complete with driver and lamp and incl eassy to instl with base plate connection complete all as specified and directed. |
| 32 | M&L for checking the serviceability of the different spares/components/parts of high mast light fittings any wattage/capacity of any description and in any position, repalcement of unserviceable/damageed/ broken parts(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed by Engineer-in-Charge. Note :- Contractor should arrange crane and eqpt as required for the checking the faulty light at his own cost and spare parts and components/parts of light but new light fittings shall be meassured and paid seperately. |
| 33 | S&F in repair 10 Sqmm 2 Core 1100 volts grde heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed all as specified and directed. |
| 34 | All as per item No 32 herein above but 6 Sqmm 2 Core. |
| 35 | S&F in repair 2x1.5 Sqmm 1100 Volt garde PVC insulated and PVC sheathed stranded copper conductor cable all as specified and directed. |
| 36 | S&F in repair of digital timer switch for switching on/off street light and other elctric device according to rising/setting of the sun with combination fuction for creating switching programes in which the devices are switched according to astronomical time and fixed present time all as specified and directed. |
| 37 | S&F in repair of contacter up to 65 Amp, 240/440 Volt for street light timer all as specified and directed. |
| 38 | S&F in repair of street light panel of capacity 12 KW , 440 Volt including digital timer, contacter, suitable size of connector, required MCBs of suitable size and internal wiring complete all as specified and directed.Make:- Havells Cat Part No:- IHXTS09120 or equivalevt. |
| 39 | S&F in repair of street light panel of capacity 6 KW , 240 Volt including digital timer, contacter, suitable size of connector, required MCBs of suitable size and internal wiring complete all as specified and directed.Make:- Havells Cat Part No:- IHXSS01060 or equivalevt. |
| 40 | S&F in repair submain wiring in PVC conduit of suitable size with 2x1.5 Sqmm main conductor + 1x1.5 Sqmm earth wire of FR,PVC insulated stranded copper conductor, single core cable in surface/recessed in wall or floor as required all as specified and directed. |
| 41 | M&L for cleaning, scrapping, preparaing of old painted steel tubular pole 9M long and applying one coat of aluminium red oride primer and two coats of aluminium paint to pole and accessoreis / fittings whatever fixed on pole including marking /writing pole No on each pole with yellow SE paint with 5CM large bold letters on black background of suitable size at a height of 2M above GL complete all as specified. |
| 42 | S&F in repair street light junction box of size 250mmx200mmx100mm with MCB SP 6A 01 Nos, 10KA capacity, and 04 nos terminal for looping of cable on procelin insulator suitable capacity for 3 phase and neutral complete with necessary MS clamp made of 25x3 mm MS flat, bolts, nuts,wahsers etc for fixing to steel tubular / rail pole including dismantling of existing old unserviceable junction box with all accessoreis complete all as specified and as directed.Make:- Syntex Cat Part No GSJB-3020 or equivalent. |
| 43 | S&F in repair MCB SP 6 to 32 Amp 240V, 10 KA all as specified and directed. |
| 44 | S&F in repair MCB SPN 6 to 32 Amp 240V, 10 KA all as specified and directed. |
| 45 | S&F in repair MCB TPN 40 to 100 Amp 240V 10 KA all as specified and directed. |
| 46 | Supply, fix and testing in repairs of 1.5 HP, three phase electric motor to lower & raise the carriage for high mast light fixing with necessary clamps, nuts, bolts including dismantling of existing old unserviceable electric motor with all accessoreis complete all as specified and as directed. |
| 47 | Supply & fix in repair LED Driver of suitable to 60 Watt LED street light/security light fitting all as specified and directed. Please Enable Macros to View BoQ information |