| 1 | A) SPLIT TYPE AC : Dismantling the unserviceable uncut rotary compressor from the AC unit and replacement with new compressor for split type Air conditioner of approved Make all as specified and as directed. |
| 2 | All as per item No.1 above but for AC of 2.0 Ton capacity.Note : Supply only Gas for charging as required will be measured and paid separately under relevant item of this schedule. |
| 3 | M&L for Servicing/ overhauling by flushing out of complete condensing and evaporator unit, jointing the compressor suction and delivery tubes including replacement of any description of liquid line, strainer assembly, capillary tubes etc., including rectification of leakage from the systems and line, vaccumising, dehydrating, oil and gas charging and testing and commissioning of system upto 2 TR capacity of Split type Air conditioners . NOTE :- (i) The rate quoted is deemed to include the replacement of spares like copper tubes any description, strainer assembly, capillary tubes etc. (ii) Supply only Gas for charging as required will be measured and paid separately under relevant item of this schedule. |
| 4 | S&F the following spares/ items for split type AC upto 2 Ton capacity including dismantling the old unserviceable spares/ items. |
| 5 | Remote control. |
| 6 | Electronic PCB Board compatible for existing AC upto 2 Ton |
| 7 | Electronic PCB Board compatible for existing Inverter AC upto 2 Ton |
| 8 | Fan motor 1/6HP capacity. |
| 9 | Condenser coil |
| 10 | Cooling Coil |
| 11 | Suction valve |
| 12 | Discharge valve |
| 13 | PVC conduit pipe 20mm dia including all accessories to drain out pipe |
| 14 | Indoor unit blower motor of 1.5/ 2.0 ton split type AC |
| 15 | Running capacitor 45/50 MFD |
| 16 | Fan blade set |
| 17 | Air filter suitable for air conditioner 1.5 /2.0 Ton capacity |
| 18 | Outer cover for Outdoor unit of existing AC 1.5/ 2.0 TR capacity |
| 19 | Taking down of existing split type Air conditioner any capacity making good the disturbed surface and refixing at new location including Supply & fixing factory fabricated support suitable to mount out door unit (one pair per AC) and duly making holes into wall for insertion of copper pipe, drain pipe and 3 core cable gas filling to requisite level and testing complete all as specified and as directed. Note: (a) This item to be operated for change of location only, as split type AC unit to be shifted from one location to other location.(b) Supply only compresser gas will be measured and paid separately. |
| 20 | Supply and fix Indoor unit of split type AC 1.5/2.0 Ton capacity all as specified and as directed by Engineer-in-Charge including taking down existing unservicable indoor unit. |
| 21 | B). REFRIGERATOR Dismantling the unserviceable uncut hermetically sealed compressor from the Refrigerator unit and supply and fix hermetically sealed compressor for refrigerator of approved make 180 ltrs to 400 ltrs capacity. Note: Supply only Gas for charging as required will be measured and paid separately under relevant item of this schedule. |
| 22 | Supply only Gas R - 134 A |
| 23 | Supply only Gas R - 32 |
| 24 | Supply only Gas R - 410 A/R-22 |
| 25 | M&L for flushing out of complete condensing and evaporator unit, jointing the compressor suction and delivery tubes including replacement of any description of liquid line, strainer assembly, capillary tubes etc., including rectification of leakage from the systems and line, vaccumising, dehydrating, oil and gas charging and testing and commissioning of system upto 180 to 400 ltr cooling capacity. NOTE :- (i) The cost deemed included the replacement of spares like copper tubes any description, strainer assembly, capillary tubes etc.(ii) The required gas shall be measured and paid under relevant items of this schedule. |
| 26 | S&F the following spares/ items for 180 to 400 ltrs Refrigerator including dismantling the old unserviceable spares/ items |
| 27 | Relay box type |
| 28 | Over load protector 1/6HP |
| 29 | Thermostat defrosting type |
| 30 | Door magnetic gasket |
| 31 | Cooling coil |
| 32 | Condenser coil |
| 33 | New frost free motor |
| 34 | M & L servicing Refrigerator by cleaning all parts/ fittings, washing out of condensing unit with water to remove deposition of materials checking of all parts for smooth functioning carrying out servicing & lubricating of all parts, checking and tightening electrical connections and ensuring complete unit in perfect working condition. NOTE:- The rate quoted is deemed to include for all consumables required for servicing and transporting to MES store yard if onsite servicing is not feasible. However S&F of compressor if any needs to be replaced and supply only gas for charging will be measured and paid separately. |
| 35 | C). VOLTAGE STABILIZER Taking out the voltage stabilizer of any make of following capacity transporting to work shop, to detect/ identify the nature of defects/ repairs and reassembling after repair/ servicing commissioning at site and testing complete etc., & all as directed and specified for following capacity:- |
| 36 | 4 KVA & 5 KVA |
| 37 | 2 KVA & 3 KVA |
| 38 | M&L in replacement Sub main wiring with two single run of single core PVC insulated cable with copper conductor multistranded 1100 volts grade 4 sqmm through and including with suitable size of PVC rigid conduit and its accessories, surface/ ceiling along with fixing arrangements etc., including 4.0 sqmm PVC insulated multistranded copper earth continuity conductor and connected to common earth dolly complete all as specified and directed by Engineer-In-Charge including taking down existing submain wiring any type and size. |
| 39 | All as per item No.15 above but with 2 runs of 6 sqmm.Note for Sl Item No.15 & 16:- (i) Two runs of cable, one/ two runs of earth conductor cable and one run of PVC conduit shall be measured as one unit. (ii) The cost deemed to be included for cutting and chasing and making good the disturbed surfaces. |
| 40 | S & F three core flexible cord copper wire of size 3 Core 4 Sqmm suitable for all summer appliances all as specified & directed by Engineer-In-Charge. |
| 41 | S&F the following copper pipes for all summer appliances of any capacity including dismantling the unserviceable pipe. |
| 42 | Copper pipe 1/2\\" dia |
| 43 | Copper pipe 5/8\\" dia |
| 44 | Copper pipe 1/4\\" dia |
| 45 | D). WATER COOLER / DEEP FREEZERSTaking down carefully, dismantling and opening the Water coolers / Deep Freezers of any capacity / any make after disconnecting the electric connection for attending repairs, reassembling, refixing and re-connecting the Water coolers / Deep Freezers to power point / connector after necessary servicing and replacing the spare parts etc., complete all as specified and directed.Note : The rate quoted is deemed as required to include for S & F spares (except compressor & gas charging). |
| 46 | Rewinding the blower fan motor of water coolers of any Make with super enamelled copper wire of same existing (original) size to get design speed for the particular make of fan motor including insulating varnishing, providing sleeves to copper wire ends all as specified and directed for the capacity of fan motor 1/5 HP (for 150 litres water cooler). |
| 47 | All as per item No.20 above but, fan motor 1/16 HP (for 120 litres water cooler) |
| 48 | All as per item No.20 above but, fan motor 1/32 HP (for 80 litres water cooler) |
| 49 | Flushing the complete condensing unit, Cooling coil unit and replacement of liquid lines, Strainer / drier capillary tubes etc., and rectification of leakage from the system, Vacumising, dehydrating oil and gas charging including testing and commissioning complete and all as specified and directed for the water cooler of capacity 150 litres.Note : The rate quoted is deemed to include for supply and charging Freon gas as required. |
| 50 | All as per item No.23 above but, water cooler of capacity120 Litres |
| 51 | All as per item No.23 above but, water cooler of capacity 80 Litres Please Enable Macros to View BoQ information |