| 1 | Loading, Unloading and safe cartage of the following materials from Electricity Store Centre, Shrawasti/Bharaich to the work site/dump site. All the material at Sl. No. 1 shall be given by department and rest all the material including civil material will be arranged by the contractor itself. Any other material if required for completion of work which might not have been mentioned in bid document, shall be arranged by the contractor. (Decentralized Items Provided by the Contractor as per Estimate). |
| 2 | Carriage of ST Pole 11 / 9 Mtr. Long |
| 3 | Carriage of PCC Pole 11 Mtr long |
| 4 | Carriage of PCC Pole 8.5 Mtr long |
| 5 | Carriage of ACSR weasel conductor |
| 6 | Carriage of 33 KV XLPE cable 3x300 Sq.mm |
| 7 | Carriage of 11 KV XLPE cable 3x120mm2/3x185mm2 |
| 8 | Carriage of AB Cable 1x25/3x50+1x35+1x25 mm2/3x95+1x70+1x25mm2 |
| 9 | L.T XLPE Cable 3.5x400 Sq.mm |
| 10 | 11 KV Pilfer Proof Metering cubical |
| 11 | 11 KV CT/PT Double Metering Combined Unit CT/PT |
| 12 | 11 KV VCB I/C, O/G |
| 13 | Safe Carriage of 25 KVA T/F |
| 14 | Safe Carriage of 63/100 KVA T/F |
| 15 | Safe Carriage of 250 KVA T/F |
| 16 | Carriage of other line material |
| 17 | Erection of Single PCC Pole (11 Mtr Long) for 11 KV/LT. line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site. |
| 18 | Erection of Double PCC Pole (11 Mtr Long) for 11 KV HT line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site. |
| 19 | Erection of Single PCC Pole (8.5 Mtr Long) for 11 KV/LT. line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site. |
| 20 | Erection of Double PCC Pole (8.5 Mtr Long) for 11 KV HT line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site. |
| 21 | Erection of Single ST Pole (11 Mtr Long) for 11 KV/LT line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site. |
| 22 | Erection of Double ST Pole (11 Mtr Long) for 11 KV HT line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site. |
| 23 | Erection and Grouting of stay sets alongwith complete fittings. Cement, Sand & Brick ballast provided by the contractor at his own cost. |
| 24 | Grouting of Poles with 1:4:8 CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely. All required materials shall be provided by the contractor at his own cost. |
| 25 | Earthing of Pole as per RESSPO Norms. |
| 26 | Pipe Earthing as per RESSPO Norms. |
| 27 | Digging of trench as per norms and proper laying and commissioning of 33 KV XLPE size 3x300 Sq.mm cable on Pakka road and its hoisting with providing GI Pipe 6\\" dia (GI Pipe will be supplied by the contractor) including road restoration work as per respo norms |
| 28 | Digging of trench as per norms and proper laying and commissioning of 11 KV XLPE size 3x70 mm2/3x120/3x185 mm2 cable on Pakka road and its hoisting with providing GI Pipe 6\\" dia (GI Pipe will be supplied by the contractor) including road restoration work as per respo norms |
| 29 | Digging of trench as per norms and proper laying and commissioning of L.T KV XLPE size 3.5x400/240 mm cable on Pakka road and its hoisting with providing GI Pipe 6\\" dia (GI Pipe will be supplied by the contractor) including road restoration work as per respo norms |
| 30 | Construction of Masonry Plinth of Size 6.0x6.0x6.0 Mtr Suitable for 400/630 KVA Capacity of Tronsformer Including Fixxing of Pole on Plinth All Required Materials Provided By the Working Agency at his own. |
| 31 | Construction of Civil Work/Pilfer Room/ All Required Work. |
| 32 | Fencing Suitable for 250/400/630 KVA Capacity of Tronsformer Including Fixxing All Required Materials Provided By the Working Agency at his own. |
| 33 | Errection & Commissioning of AB cable 1x25/3x50+1x35+1x16mm2/3x95+ 1x70+1x25mm2 including fitting of Accessories (All Accessories shall be Provided by the Contractor). |
| 34 | Dismentaling of Old Pole & Line |
| 35 | Installation of 11 KV VCB I/C and O/G |
| 36 | Supply & Fixing of 33 KV Straight Through Jointing kit 3x300,3x120 Sq.mm |
| 37 | Supply & Fixing of 11 KV Straight Through Jointing kit 3x120,3x185 Sq.mm |
| 38 | Supply & Fixxing of 33 KV Cable Joint Kit Outdoor/Indoor 3x300,3x120 Sq.mm |
| 39 | Supply & Fixxing of 11 KV Cable Joint Kit Outdoor/Indoor 3x185,3x120,3x70 Sq.mm |
| 40 | Installation and commissioning of 11 KV Pilfer Proof Metering Cubical |
| 41 | Installation and commissioning of 11 KV CT/PT Double Metering Combined unit CT/PT |
| 42 | Mounting of 25 KVA T/F with complete fitting. |
| 43 | Mounting of 63/100 KVA T/F with complete fitting. |
| 44 | Mounting of 250 KVA T/F with complete fitting. |
| 45 | Laying, stringing, sagging & binding of conductors of 11 KV in 3 phase, 3 wire line with jumpering (where as required). |
| 46 | Cradle Guarding of 11 KV line at road crossing, 11KV line crossing, canal line crossing as per RESPO specification at double pole and 2600mm long at single pole by stringing and sagging of 2 No. G.I.wire, tightining with mounting. |
| 47 | 11 KV Air Breack Switch TPMO Set (Providing By Working Agency) |
| 48 | 11 KV D.O Fuse Set (Providing By Working Agency) |
| 49 | D.O/TPMO Channel With Clamp (Providing By Working Agency) |
| 50 | MS Nut and Bolt All Size (Providing By Working Agency) |
| 51 | F-Bracket (Providing By Working Agency) |
| 52 | Clamp For ST/PCC Pole All Type (Providing By Working Agency) |
| 53 | L.T XLPE Cable 3.5x240 Sq.mm (Providing By Working Agency) |
| 54 | Loop Insulator for Stay |
| 55 | LT Clamp With-Hooq |
| 56 | Dead End Clamp |
| 57 | Suspension Clamp |
| 58 | Aluminum Lug |
| 59 | Supply & Fixxing of L.T Armored Cable 4x16 Sq.mm |
| 60 | PG Clamp |
| 61 | Danger Board With Clamp |
| 62 | G.I Pipe 6\\" Dia Please Enable Macros to View BoQ information |