| 1 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manhole, pier holes, etc and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge. |
| 2 | M&L Cement concrete 1:4:8Type D2 (using 40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and as directed by Engineer-in-Charge. |
| 3 | M&L for Reinforced cement concrete (DESIGN MIX M-30, using 20mm graded aggregate) as foundations, including rafts, footings foundation beams, plinth beams, bases for columns, etc basement slabs, under reamed piles and mass concrete |
| 4 | M&L for use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits(if any) of foundation and plinth beams, and similar work vertical of to batter, rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-Charge. |
| 5 | M&L for Reinforced cement concrete (DESIGN MIX M30, using 20mm graded aggregate) as Beams, cantilivers, bressummers, lintels over 1.5m span complete all as specified and as directed by Engineer-in-Charge. |
| 6 | M&L for use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams etc, rough finished surfaces of concrete complete all as specified and as directed by Engineer-in-Charge. |
| 7 | M&L for Reinforced cement concrete (DESIGN MIX M-30, using 20mm graded aggregate) as Columns, pillars, piers, posts and struts complete all as specified and as directed by Engineer-in-Charge. |
| 8 | M&L for use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surfaces of concrete, square, rectangular or polygonal complete all as specified and as directed by Engineer-in-Charge. |
| 9 | M&L for pre-cast cement concrete block masonry 1:3:6 (20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete |
| 10 | M&L mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, includiing cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 11 | M&L mild steel CRS TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, includiing cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 12 | M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc 15cm thick, spread, levelled and rammed including wataring complete all as specified and as directed by Engineer-in-Charge. |
| 13 | M&L Hardcore(broken stone of boulder)of guage n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge. |
| 14 | M&L 100mm thick Cement concrete type B-2, 1:4:8 (using 40mm graded aggregate) as in sub base complete all as specified and as directed by Engineer-in-Charge. |
| 15 | M&L 25mm thick Cement concrete 1:2:4 type B-0 (using 12.5mm graded aggregate) as in flooring, finished surfaces even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 16 | M&L Non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in Cement Mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 17 | M & L for M&L for Glazed coloured ceramic tiles in vertical surfaces 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match and laid over 10mm thick cement backing coat in Cement Mortar 1:4. cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L 75mm thick Cement concrete type C-2 , 1:3:6 (using 40mm graded aggregate) as in plinth protection /flooring finished surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 19 | M&L for 15mm thick Rendering on fair faces of brick work or concrete sureces in Cement Moratar 1:4 finished surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 20 | M&L for 10mm thick Rendering on fair faces of brick work or concrete sureces in Cement Moratar 1:6 finished surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 21 | M&L for preparation of new plastered surfaces of wall incl pilasters / cornices etc and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS-15489 : 2004 : Alkali & fungal resistant, dirt resistant, exterior paint of required shade (company Depot Tinted) with silicon additives @1.43 Liters/10 Sqm over and including priming coat of exterior primer applied @ 0.90 Litre / 10 Sqm complete all as specified and as directed by Engineer-in-Charge. |
| 22 | M&L Preparing newly plastered surfaces of walls and applying two coats of oil bound distemper over one coat of Chalk whiting, on plastered surfaces, prepara-tory to distempering complete all as specified and as directed by Engineer-in-Charge. |
| 23 | S&F Factory made solid panel PVC door shutter 30mm thick(style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottim rail. Penelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 24 | S&F PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinfoced with MS Square tub, suppling & fixing in opening as per specification and drawing. |
| 25 | Hoisting and fixing 500 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindricla vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I |
| 26 | S & F for 20mm bore Stop Valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed |
| 27 | S & F for 20mm bore Ball brass valves high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed |
| 28 | S & F Towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats(Minimum weight-170 gms) |
| 29 | S&F Vitreous China squatting pan of pattern “long pan”, size 580 mm white with ‘P’ or ‘S” trap, front or back inlet and foot rests,any pattern (excluding flushing cistern and flush pipe) |
| 30 | S & F Soap dish, any type, fixed to plugs with chromium plated brass screws |
| 31 | S & F Vitreous China wash basin, white, flat back, size 450 x 300mm excluding taps, waste, chain and plug and porcelain stopper but including brackets |
| 32 | S & F 32 mm bore in trap Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed |
| 33 | M & L for 50 mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) |
| 34 | S & F for 15mm Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe |
| 35 | S & F for 15 mm Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule |
| 36 | S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 37 | S & F 10 Ltr PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets |
| 38 | S & F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 39 | M & L for 15mm Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors |
| 40 | M & L for 20mm Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors |
| 41 | S&F aluminium (powder coated with approved colour) ventilator, partially glazed and partially louvers, outer frame & mullion fabricated with aluminium section of size 82.50 mm x 38.00 mm x 1.50 mm thick (Cat No 20036), half portion glazed with 4 mm thick frosted glass including rubber beading, & glazing clip, half portion louvers of 80 mm wide & 4 mm thick frosted glass including aluminium louver patti including S.S wire gauge of fixing of 0.36mm dia and 1.40 width of aperture with 25x3mm think aluminium strip with screw to upper half portion of ventilator all fitting & fixture and fixed in position including taking down old ventilator complete. Note :- Section nos given above are of make jindel, contactor may be use similat section of other make mentioned in Appx 'B'. |
| 42 | Returning, fillingin, including spreading, levelling, watering and well remming in layers not exc 25cm in soft/loose soil complete all as specified and as directed by Engineer-in-Charge. |
| 43 | Removing (soil) excavated materials n exc 50m and depositing where directed at a level n exc 1.5m above the sarting point complete all as specified and as directed by Engineer-in-Charge. |
| 44 | S&F mild steel plates, Fe-290 (Gde E-165) (plain or chequered) channels, square cut or notched (ordinary and counter sunk) for forming holes without any attachement complete all as specified and as directed. |
| 45 | S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as incoating as in roof covering/cladding to wall, fixed with self tapping screws as sprecified and directed by Engr-In-Charge. |
| 46 | S&F for 4mm thick Non asbestos fibre cement building boards fixed or laid/inserted to timber/ GI/Aluminium frame work with screws fixed in ceiling |
| 47 | Excavating over areas, n. exc 1.5 m deep and getting out in soft / loose soil |
| 48 | Removing excavated meterial Exc 250m and n exc 500 m and depositing where directed at a level n exc 1.5 m above starting point in Soil. |
| 49 | Hardcore of gauge n exc. 63 mm, deposited, spread and leveled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 50 | M&L for Sand filling under floors or in foundations including watering and consolidation |
| 51 | M&L 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate)as in floors/ path finished fair and even. |
| 52 | Material & Labour for machine pressed precast concrete interlocking paver block (ISI marked) of approved shape and size of 60 mm thickness, with minimum compressive strength of 35 N / Sqmm (M-35 grade), without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer coating on top surface, with Grey cement and pigment all as specified and as directed. |
| 53 | Demolition of cement Concrete(interlocking tiles) of any description and in any position not otherwisespecifically provided for |
| 54 | Removing excavated material exc. 1.00 Km but n exc 1.5 Km and depositing where directed at a level not exceeding 1.5 m above the starting point out side MD Land. |
| 55 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete confrming to Fe-290 (Gde-E-165). |
| 56 | M&L for preparing new or previously untreated steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enemal paint over red oxide primer. |
| 57 | M&L for preparation of new plastered surfaces of wall incl pilasters / cornices etc and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS-15489 : 2004 : Alkali & fungal resistant, dirt resistant, exterior paint of required shade (company Depot Tinted) with silicon additives @1.43 Liters/10 Sqm over and including priming coat of exterior primer applied @ 0.90 Litre / 10 Sqm. |
| 58 | S&F for 40mm Tubes, 'Medium grade', galvanised, with all fitting including Tank Nipple; laid in trenches |
| 59 | S&F Gun-metal, globe or gate valves of 20mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed |
| 60 | Fixing only chain link fencing including lines wires, any mesh size and type to any of standards, rails, straining bolts,etc including provn of binding wire complete all as specified and directed. |
| 61 | Supply only chain link MS galvanised fencing conforming to IS 2721:2003 including line wires of 4mm dia straining bolts etc including provn of binding wire complete all as specified and directed. |
| 62 | S&F Galvansed 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia bars at 75mm spacing and straining and fixing to any typeof standard rails straining bolts including securing or typing at crossing with and provn of galvanised mild steel wire staples or steel pins etc as directed (each line of wire to be measured) complete all as specified and directed. |
| 63 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/loose soil complete all as specified by Engr-in-Charge. |
| 64 | M&L for PCC 1:2:4 type C1 using 20 mm graded stone aggregate in coping complete all as specified and directed. |
| 65 | M&L for point wiring with 1.5 sqmm(22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in modular metal box , modular fittings etc including 1.5 sqmm (22/.3 mm ) PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified. |
| 66 | All as per Sl item No 65 above herein before but one socket out let 5 pins 5 Amp on the same board but with other switches complete all as specified and directed. |
| 67 | Supply and fixing modular Socket, 6A - 2/3 pin combined 2 module, all as specified & directed. |
| 68 | Supply and fixing Modular switch 1 way 6A, 1 module all as specified & directed. |
| 69 | Supply & fixing of M.C.B., single pole, 240 volts, 6 Amps to 32 Amp breaking capacity 10KA(type 'B') |
| 70 | Supply & Fixing of M.C.B. SPN, 240 Volts, 40 Amps breaking capacity 10 KA (type B curve). |
| 71 | S & F sheet metal enclosure MCB DB SPN 4 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 having door earthing complete all as specified and directed. |
| 72 | M&L in sub main wiring with 2 single core PVC insulated unsheathed cable, 1100v grade with FRLS PVC 6sq mm copper cable multi stranded conductor drawn through and including ISI marked PVC conduit 25 mm dia complete, fixed on walls/ceilings with PVC saddles as per IS including of 6 sqmm dia FRLS PVC Copper cable green colour as earth wire connected to earth all as specified and directed by Engineer-in-Charge. |
| 73 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 74 | Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder includingLED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 75 | Supply & fix exhaust fans steel body AC single phase 230/ 240 V of size 300 mm sweep, blades,frame andlouvers all as specified and directed by Engineer in charge. |
| 76 | Supply and fixing of Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body all as specified and directed by Engineer in charge. Please Enable Macros to View BoQ information |
| 77 | Supply and fixing of Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body all as specified and directed by Engineer in charge. Please Enable Macros to View BoQ information |