| 1 | Earth work in excavation of all kind of soil, by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth,1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and directed. |
| 2 | Rolling and consolidating formation surfaces in cutting with 8 to 12 tonne power roller complete all as specified and directed. |
| 3 | M & L for Soling (or subbase base with broken boulders or quarried stone,inter stices filled with coarse sand,surfces formed and rolled with 8 to 12 tonne power roller and consolidated to required camber and granite for 150mm spread thickness complete all as specified and directed. |
| 4 | M & L for Laying and compacting 150 mm thick (compacted thickness) Wet Mix Macadam (WMM), laid in two layers of 75 mm each grading as per table 400-13 of MoRTH specifications for Road and Bridge works 2013 manufactured in WMM plant material comprising of clean, crushed, graded aggregate and granular material premixed with wate to a dense mass,spreading with sensor paver and rolling with vibratory roller of capacity 80-1OOKN static weight and consolidating to required gradien and camber complete all as specified and directed. The finished surface tolerances to be as per Table 900-1 of MoRTH specifications for Road and Bridge works 2013 complete all as specified and directed. |
| 5 | Material and labour for preparation of Un-surfaced wet Mix macadam by brushing with wire brushes,levelling, cutting with scrapper for removing caked mud etc. sweeping with brooms and finally fanning cleaned surface with gunny bags to romove all loose dirt etc & applying evenly a tack coat with bitumenious primer / tack coat, using paving bitumen of Grade VG-30 at the rate of 10 Kg / 10 Sqm complete all as specified and directed. |
| 6 | M&L for 75mm thick Premix bituminous,macadam laid/rolled and compacted to required gradient and camber (consolidated thickness 75 mm or less) with using paving bitumen complete all as specified and directed. |
| 7 | M&L for paving bituminous premixed asphaltic semi dense concrete 40mm consolidated thickness (minimum) with 5.5% binder content of paving bitumen Gde-VG-30 by weight of total mix, rolled and compacted, mixed in mechanical hot mix plant and pre-mix material laid with mechanical paver incl premixed sand seal coat with 0.06 cu.m. of sand mixed with 6.8 kg of bitumen, finished including rolling to required gradient and camber with 8 to 12 tonne power roller to required compaction complete all as specified and directed. |
| 8 | M&L for Cement concrete 1:2:4 Type B-2 (using 40mm graded stone aggregate) to fix goal post on ground complete all as specified and directed. |
| 9 | S&F 8 layers of acrylic surface coating one layer of priming coat, one layer of resurfacer coat, three layers of cushion coat, one layer of base coat & two layers of top coat over bituminous surface etc, ITF approved material with 2 years of warranty etc complete all as specified and directed. (Make: Excell sports international, passion sports or equivalent). |
| 10 | S & F basket ball pole right angle pattern, 2.2 m highwith 12mm toughen glass/Acrylic board 6\\"x6\\" heavy right angle pipe with dunking ring with foundation bolt installation & all fitting and fixture complete all as specified and directed. (Make: Excell sports international, passion sports or equivalent). |
| 11 | M & L for Basket ball Coart line Marking, ITF approved complete all as specified and directed. (Make: Excell sports international, passion sports or equivalent). |
| 12 | S&F of 6- a side football portable goal post of MS pipe height as per standered with foundation installation, with two coat of primer & double coat synthetic paint, complete all as specified and directed. (Make: Excell sports international, passion sports or equivalent). |
| 13 | S&F of Movable Bedminton poles high quality MS tube iron box, weight 70 kg to 80 kg as per international standered complete all as specified and directed. (Make: Excell sports international, passion sports or equivalent). |
| 14 | M & L for Badminton Coart line Marking, complete all as specified and directed. |
| 15 | S&F tennis poles made of MS square pie 4\\"x 4\\" height as per standerd 1.07 mtrs, painted with two coat synthetic enamel with primer as per international standered complete all as specified and directed. |
| 16 | M & L for Tennis Coart line Marking, complete all as specified and directed. (Make: Excell sports international, passion sports or equivalent). |
| 17 | S & F Artificial turf material type 40mm for volleyball court & 50mm thick for football ground fabrillated 100 % polyethene, std D-tex:8900, Primary backing 100% woven polypreleyne, UV resistence, pile weight 935gm/sqm, turf pile height 40mm, machine guage 3/4 \\", roll width 4 mtrs, sand fill 7mm and rubber infill 19mm as approve make for volley ball court & 6-a Side footbal pitch incl line marking with white turf grass of same quality etc. all fitting & fixing with adhessive complete all as specified and directed. (Make: Excell sports international, passion sports or equivalent). |
| 18 | S&F of MS Volley ball poles, Fixed type Ias per standered size complete all as specified and directed. (Make: Excell sports international, passion sports or equivalent). |
| 19 | Excavation in trenches not exc. 1.5 mtr wide and not exc. 1.5 mtr depth for foundation,cesspits, manholes etc. and getting out hard/dense soil complete all as specified and direcetd. |
| 20 | M&L for PCC 1:4:8 type D-2 using (40 mm graded stone aggregate) in foundation,filling and mass concrete complete all as specified and directed. |
| 21 | M&L for mild steel TMT bar 5mm dia and over upto and including 10mm dia in stirrups, spacers & binders cut to length bend to shape required incl cranking bending spirally for column, hooking ends & binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips quality conforming to TMT bars complete all as specified and directed. |
| 22 | M&L for mild steel TMT bar 10mm dia and over cut to length bend to shape required indd cranking bending spirally for column, hooking ends & binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips quality conforming to TMT bars complete all as specified and directed. |
| 23 | All as per Item No.22, above but 6 to 8 mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 24 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for flat rough finished surfaces complete all as specified and directed. |
| 25 | M&L for RCC (nominal mix) type B-1 1:2:4 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for coloumns etc, basement slabs, under rammed piles and mass concrete complete all as specified and directed. |
| 26 | Returning filling in including speading,leveling ,watering and well ramming in layer complete all as specified and directed. |
| 27 | Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.50 mtr from starting point complete all as specified and directed. |
| 28 | Surfaces excavation n.exc 30cm deep and averaging 24cm deep and getting out in hard/dense soil complete all as specified and directed. |
| 29 | M&L for hard core of broken stone boulders of guage not exc 63mm using stone aggregate, deposited , spread and levelled in layer not exc 15cm thick watered and rammed to a true surface complete all as specified and directed. |
| 30 | Material and labour for 100 mm thick cement concrete type D-2, 1:4:8 (using 40 mm graded aggregate) as in flooring and all other similar works complete all as specified and directed. |
| 31 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of stone dust/fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;complete all as specified and directed. |
| 32 | M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in Kerbs and edging to road , divider and foothpath etc incl necessary earthwork with plain fair faces, incl chamfered wheathering, throating etc and setting in cement mortar 1:3 complete with joints to match complete all as specified and directed. |
| 33 | M&L for preparation of new concrete surface of any description over 10cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over priming paint compete all as spcified and directed. |
| 34 | M&L for plain cement concrete, type B1, 1:2:4 (Using 20mm graded granite stone aggregate) cast in situ in bed blocks, copings and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified and directed by the Engineer in Charge.. |
| 35 | Excavation in post hole (or similar holes) each n.exc 0.5 cum and getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm watering and removing surplus soil to a distance n.exc 50m and making good in soft /loose soil complete all as specified and directed. |
| 36 | M & L for PCC 1:3:6 type C-2 in foundation filling and mass concrete complete all as specified and directed. |
| 37 | M & L for angle iron as in fencing post /Strut & flat iron, incl cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets ( for securing wire mess) incl all necessary drilling , bolting or reveting etc complete all as specified and directed. |
| 38 | M & L for mild steel round bars 10mm dia and over cut to length bent to shape required and fixing as required in fencing.complete all as specified and directed. |
| 39 | Supply only chain link MS galavanised fencing complete all as specified and directed. |
| 40 | Fixing only chain link fencing including line wires, and mesh size type of standards, rail straining bols etc size of mess 100x100mm 4mm dia wire complete all as specified and directed. |
| 41 | S & F MS bolts machine made with hexagonal or square head one end and screwed the other or screwed both end n.exc 5 cm long 12mm dia complete all as specified and directed. |
| 42 | M&L for preparation of new steel surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat red oxide, zinc chrome primer complete all as specified and directed. |
| 43 | M &L Two coat of synthetic enamel paint to steel surface over a coat of red oxid primer n exc 10 cm width or girth incl preparation of new surfaces complete all as specified and directed. |
| 44 | M & L for preparation of surfaces of steel and iron work new of any description and girth at treated area n.exc .5 sq each and treated with Tar/ Coal tar black paint complete all as specified and directed. |
| 45 | M&L for fly ash brick work built in cement mortar (1:4) using straight or curved on plan exceeding 6 mtr mean radius complete all as specified and directed. |
| 46 | M&L for 15mm thick rendering in CM 1:4 finishing even and smooth using extra cement complete all as specified and directed. |
| 47 | M&L for Preparation of newly plastered surface and applying three coats of white wash on walls complete all as specified and directed. |
| 48 | M&L for Reinforcement cement concrete (nominal mix) type B-1 (1:2:4) ( 12.50 mm graded stone aggregate) as in foundations, footings of columns etc complete all as specified and as directed. |
| 49 | Use and waste form work to sides of concrete foudations, footings for flat and rough finished surfaces of concrete complete all as specified and as directed. |
| 50 | Use and waste form work to sides of columns, pillars posts struts for flat and rough finished surfaces of concrete complete all as specified and as directed. |
| 51 | M&L 20mm thick Granite (of any type) work (table rubbed and polished and exposed visible edge moulding/rounding ) in steps, jambs, pillars, window cills, cooking platforms and like in 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.complete all as specified and directed. |
| 52 | S&F mild steel framed work such as framed and hung as gates ornamental and intricate design, including pintle hinges, stops,hand-made sliding bolts, etcgrills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framed work and similar works conforming to Fe-290 Gd E-165 complete all as specified and directed. |
| 53 | M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in coping to drainage complete all as specified and directed. |
| 54 | S&F of MS work framing/gratings ( tee, angle, channel or flat sections etc) including distance pieces, cleats etc. framed brackets of angles with cut to shape, drilled and countersunk for screw, in-cluding welding angles, as necessary, gusset plates, riveting, etc., brackets, con-forming to Fe 410-0 E- 250-grade A complete all as specified and directed. |
| 55 | M&L for steel tubular swaged poles complete with MS base plate, finial taper plug, bolts, nuts & screws type 410, SP-31 (9 mtrs long), erected to truely vertical position, painting externaly embedded portion in PCC with black bitumenous paint and externally exposed to surfaces with aluminium paint in two coats, making five alternate strips 30cm wide with black and yellow paint in two coats, marking MES number with black paint complete all as specified and directed. (Note : Excavation and PCC will be measured and paid for separately under respective items of this schedule) |
| 56 | Sppply & Laying XLPE insulated, armoured, electric cable with aluminium conductor,multi stranded 1100 volts grade, laid in trenches, fixed on poles / walls or passing through pipes including provision of necessary lugs and glands & making necessary connection complete all as specified and directed for the following:-(Note : excavtion and earth work, cable protection sand cushioning will be measured and paid seperately) (a) 10 Sqmm, 4 core. |
| 57 | (b ) 16 sqmm, 4 core |
| 58 | (c) 25 Sqmm, 3 1/2 core |
| 59 | Excavation in trenches not exc. 1.5 Mtr wide and not exc 1.5 Mtr deep in any type of soil and getting out complete all as specified and directed. |
| 60 | All as above item No 60, above, but depth exc 1.5 Mtr and not exc 3.0 Mtr deep complete all as specified and directed. |
| 61 | M&L for filling approved fine river sand in trenches as cable cushion to the full width of excavated trench, under and over cable complete all as specified directed.(Note : Punned thickness of sand shall be measured) |
| 62 | M&L for bricks slightly over burnt (kiln burnt) , modular bricks, best quality, locally available, laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection complete all as specified and directed. |
| 63 | Supply and errecting LT Panel outdoor type (CPRI approved) mounted and fixed with PCC foundation, made out of MS sheet factory assembled & factory fabricated out of 3.15 mm thick sheet steel with suitable size MS angel frame duly spray painted with two coats of gray synthetic enamel paint over one coat of red oxide zinc chrome primer after preparatiion of surface, with required civil works & with and including 4 Nos Copper bus bars 200 Amps with suitable size porcelain insulators & wiring with copper cable of suitable size, connecting including indicating lamp LED type for each phase, incl in built industiral type locking arrangement, front operated openable incl necessry arrangement for fixing with suitable clamps, nuts & bolts etc. The panel pre wired with PVC insulated copper conductor danger notice board, feeders marked, and testing & commissioning, complete all as specified and directed.consisting of the following :- (Make: Indoasian/Power system and control/ Shalabh (India) Industries (a) MCCB 4 pole 415 Volts 50Hzs 63 Amps 36 ka repturing capacity - 01 No (incoming)(b) MCB 4 pole 415 Volts 50Hzs 20 Amps 10 ka repturing capacity - 05 Nos (outgoing)(c) ON / OFF LED Type indication lamp with toggle switch - Set of 03 |
| 64 | M&L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to galvanised earth lead wire 4.0mmdia by means of bolts. nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length , provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts,bolts, earthing shall be done all as per shown electrical plate No 5 of SSR part 1 Including neccessary excavation in disintergratedand hard soil and 20mm dia GI pipe with funel for watering PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr -in -Charge. |
| 65 | M&L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI strip 32x6mm by means of bolts. nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length , provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts,bolts, earthing shall be done all as per shown electrical plate No 5 of SSR part 1 Including neccessary excavation in disintergratedand hard soil and 20mm dia GI pipe with funel for watering PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr -in -Charge. |
| 66 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete all as specified and directed. |
| 67 | S&F IP 65 Pole Box, made of high quality Polycarbonate(shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, having high impact, made of halogen and silica free recyclable material), UV resistant, having high grade gasket made of Polyurethane, should withstand glow wire test at 9600C in accordance with IEC 60 695- 2-11 UL subject 94, should be flame retardant and self-extinguishing, the system should have test certificate in accordance with IEC 60 439-1, (IS8623), & IEC 60529, including provision of three phase connection with MCB SP 6 amps- 01 Nos complete all as specified and directed. |
| 68 | M&L wiring for circuit/submain wiring with 2.5 sq mm 2 runs of single core multistrand PVC insulated, unsheathed cable & one run of 1.5 sqmm PVC insulated copper conductor single core cable as earth conforming to IS - 694, 1100 volts with copper conductor drawn in and including 20 mm dia or higher non metalic PVC grey conduit with all accessories such as Tees, Elbows, Junction box, Reducers etc as required and connecting to pole box to light fitting complete all as specified and directed. |
| 69 | S&F GI tubing, light grade, ISI marked 80 mm bore pipe laid in trenches/duct or in road crossing or fixed to wall/poles for protection of cable incl taking out old pipe of any grade complete all as specified and directed. |
| 70 | All as per Item No. 69, above but 40 mm bore pipe. |
| 71 | M&L for boaring holes under the road/ hard standing with the help of trenchless technology using ultra sound technique and necessary machine including GI light grade pipe 80 mm bore suitable for 0.4 Mpa working pressure not less than one mtr below ground level complete all as specified and directed. Note: The Cost of GI light grade pipe shall measure and paid seperately. |
| 72 | S&F Rigid non mettalic PVC Conduit of size 20 mm exclusive of boxes (junction/RM terminal) but inclusive of all tees,bends,elbows,reducers,bell mouth tube ends and fixing accessories such as couplers ,lock nuts,saddles,pipe hook sets complete all as specified and directed. Please Enable Macros to View BoQ information |