| 1 | Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, all as specified . |
| 2 | Demolition of plain cement concrete in ground floors or above ground floor and paving n.exc 15 cm thickness (Below or above ground level) |
| 3 | M&L For Brick work with sub class 'B' Bricks (old size bricks),straight or curved on plan exceeding 6 m mean radius with old size bricks built in cement mortar 1:6 as in brick edging. |
| 4 | All as per srl item No. 3 above but except bricks. |
| 5 | M&L for walling of random rubble masonary, uncoursed well bonded, bedded and solidly hearted built in CM 1:6. complete all as specified and directed by Engineer-in-charge. |
| 6 | All as per item No.5 above, but except stone. complete all as specified and directed by Engineer-in-charge. |
| 7 | M&L For raised pointing to random rubble walling uncoursed in CM (1:3) complete all as specified. |
| 8 | M&L For 15mm thick cement plaster in cement mortar 1:4 on stone masonry,Brick Masonary surfaces or surface other than fair face of brickwork and finished even and smooth without using extra cement incl Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water Incl Preparing plastered or unplastered new surfaces of walls and applying two coats of cement base paint Complete all as specified. |
| 9 | Preparation of old decorated brick/concrete/ plastered/unplastered surfaces of walls, Pillars, cornices etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots, rubbing with sand paper and applying two coat of cement base paint on walls, pillars, cornice etc (upto 2nd storey with necessary scaffolding complete all as specified and directed. |
| 10 | M&L Complete removal of existing treatment and preparation of old surfaces and applying two coats of weather Proof Apex Paint Complete all as specified. |
| 11 | M&L Complete removal of existing treatment and preparation of old surfaces and applying one coats of weather Proof Apex Paint Complete all as specified. |
| 12 | M&L for Cement concrete type D-2, 1:4:8(40mm graded agg) as in foundations, filling and mass concrete, sub base all as specified. |
| 13 | M&L for Pre-polished glazed designer ENDURA tiles, coloured 30cm x 30cm x 8-10mm thick set jointed and pointed in neat cement slurry pointed in white or coloured cement to match in floors over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 14 | Chequered cement concrete tiles 30cm x 30cm x 25mm thick/25cm x25cm x25mm thick, Glossy finish set, with grey cement and pigment, jointed and pointed in neat cement slurry in floors over and incl 20mm thick screed bed in CM 1:4, complete all as spd & direction. |
| 15 | M&L Machine pressed precast concrete interlocking coloured (red/ yellow) paver blocks, Glossy finish, any shape and size of 60mm thickness M-35 grade over and incl 50mm thick sand cusion complete all as specified (Sample & laying pattern approved by GE) complete all as specified. |
| 16 | M&L Machine pressed precast concrete interlocking coloured (red/ yellow) paver blocks, Glossy finish, any shape and size of 80mm thickness M-35 grade over and incl 50mm thick sand cusion complete all as specified (Sample & laying pattern approved by GE) complete all as specified. |
| 17 | M&L For Plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates as in copings, kneelers, apex stones, bed plates, etc. and in similar works including weathering,slightly rounded or chamfered angles and throating and necessary form works,all as specified . |
| 18 | Dismantling post or Precast RCC struts any section, including taking out embedded portion in concrete and making good the disturbed ground. complete all as specified and directed by Engineer-in-charge. |
| 19 | Excavation in post holes (or similar holes) each in hard & soil n. exc. 0.5 cum, getting out, returning filling in an ramming earth or broken rubble mixed with earth around, in layers n. exc. 25 cm, watering and removing surplus soil to a distance not exc. 50 M and making good complete all as specified. |
| 20 | S&F Posts & struts of MS angle iron in fencing including cutting tops to shape as directed, drilling hole, notching for wire etc flat iron fillets(for securing wire mesh) including all necessary drilling bolting or riveting etc. complete all as specified and directed by Engineer-in-charge. |
| 21 | M&L painting the surfaces of steel any description over 10cm in width or girth, with two coats of synthetic enamel paint over a coat of red oxide incl preparation of new steel surface complete all as specified and directed by Engineer-in-charge. |
| 22 | M&L preparation of old painted steel surfaces of any description not otherwise specified over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed by Engineer-in-charged. |
| 23 | S&F For Mild steel galvanised chain link of mesh size 100mmx100mm and thickness of line wire 3.00mm dia including fixing with straining bolt, binding wire etc including dismantling fencing wire mesh, any type complete all as specified and directed by Engineer-in-charge. |
| 24 | S&F For Mild Steel round bars 12mm dia for strengthening of chain link. complete all as specified and directed by Engineer-in-charge. |
| 25 | S&F of mild steel screw bolts with hexagonal or square heads at one end and screwed the other end or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut length of bolt exc 5cm and n.exc 10 cm. complete all as specified and directed by Engineer-in-charge. |
| 26 | S & F in repairs Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed by Engineer-in-charge. |
| 27 | Dismantling structural steel work including doors, gates but excluding framed truss etc. |
| 28 | S&F of Bands, straps,Chennel, supports or stays for rainwater, ventailing pipes, including bolts, if required hooks,heavy, for large gates, hook and pintle hinges; large hasps and stables; chains;hand made sliding bolts; clamps; hold fasts; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe -290 Gde -165. complete all as specified and directed by Engineer-in-charge. |
| 29 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specifed and directed Engr-in-Charge. |
| 30 | Restraining and resecuring of steel barbed wire fencing including making good staples etc complete all as specified and directed by Engr-in-Charge. (each line wire to be measured seperately) |
| 31 | Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents. Please Enable Macros to View BoQ information |