| 1 | Prov. Distribution Transformer 11/.4KV, 100KVA |
| 2 | Prov. S/T Pole 9 Mtr W/L >200 kgf/m2 |
| 3 | Prov. RCC Muff with concrete filling |
| 4 | Prov. ACSR 6/1/3.35 mm |
| 5 | Prov. MS A.I X-arm (50x50x6 mm), Length: 2800 mm x 1 No for LA's |
| 6 | Prov. X-arm: C.I (75x40X6 mm ),Length: 2800 mm x 4 Nos for supporting DO Fuse unit & GO switch |
| 7 | Prov. X-arm: C.I (100x50X6 mm ),Length: 2800 mm x 2 Nos for T/F Bed |
| 8 | Prov. X-arm: C.I (100x50X6 mm ),Length: 460 mm x 2 Nos for supporting main channel of T/F |
| 9 | Prov. MS A.I X-arm (50x50x6 mm), Length: 2800 mm x 2 Nos |
| 10 | Prov. MS A.I X-arm (35x35x5 mm), Length: 460 mm x 2 Nos |
| 11 | Prov. MS A.I X-arm (50x50x6 mm), Length: 950 mm x 2 Nos for Bed Knee Bracing |
| 12 | Prov. MS A.I X-arm (50x50x6 mm), Length: 2800 mm x 2 Nos |
| 13 | Prov. MS A.I X-arm (50x50x6 mm), Length: 450 mm x 1 Nos |
| 14 | Prov. G.O Switch handle supporting C.I (75x40x5 mm), Length: 460 mm x 1 No |
| 15 | Prov. G.O AB Switch unit Triple pole o/d type |
| 16 | Prov. D.O Fuse unit |
| 17 | Prov. Lightning Arrestor/Surge Arrester, 9 Kv station class ( porcelain type) |
| 18 | Prov. Stay set complete |
| 19 | Prov Stay wire 7/3.15mm (6.0 kg/stay set) |
| 20 | SWG GI wire For Earthing |
| 21 | Prov. Pipe Earthing Set |
| 22 | Prov. LT Distn Panel Box for 100 kVA DTR with MCCB 160 amp 3P 35kA , ICS =100 % ICU, Kit-Kit 200 Amp(Panel should be CPRI Approved) |
| 23 | Prov. Half Clamp |
| 24 | Prov. Full Clamp |
| 25 | Prov. M.S Nuts & Bolt Off size (Galvanised/coated) |
| 26 | Prov. Aluminium Thimble |
| 27 | Prov. Aluminium Thimble 300 sq mm |
| 28 | Prov. Danger Plate |
| 29 | Prov. Barbed Wire |
| 30 | Prov. LT Cable 3.5 core 185 mm sq |
| 31 | Prov. Energy Meter 3 phase, 4-Wire, Static Tri-Vector meter (DLMS compliant, system of capacities-/110 V and CT ratio - /5 Amp of\\"Category C\\"meter ) |
| 32 | Prov. HP 60.5 cm (23.8) All in one Desktop PC 24-cr0016 in (AMD ryzen 37000 series processor with 23.8 inch display , 8 gb Ram, 512 gb ssd hard drive) for SAP billing |
| 33 | Prov. Aluminium Paint |
| 34 | Prov. Chain Link fencing , Angle Iron ,Gate etc fortransformer fencing |
| 35 | Add: [Cost of Optional Miscellaneous Items (Protective Gear i.e 33 kv insulated rubber handler gloves (EN-60903 & IEC-60903) |
| 36 | Add Erection Charges Complete in all respect |
| 37 | Add Transportation Charges Complete in all respect |
| 38 | CT PT unit |
| 39 | CT-PT Combined Unit [PT:11 kV/110 V) ; CT:10- 200/5A] |
| 40 | Surge Arrester, 9 kV Station Class (Porcelain Type) |
| 41 | X-arm: C.I (100x50X6 mm ),Length: 2800 mm x 2 Nos for CT PT Bed |
| 42 | MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing |
| 43 | MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos |
| 44 | Pipe Earthing Set |
| 45 | Half Clamp |
| 46 | PVC wire 4 mm² flexible |
| 47 | 1 inch dia GI pipe for concealing |
| 48 | Full Clamps |
| 49 | Aluminium Thimble |
| 50 | Copper tinned thimble |
| 51 | Add Erection Charges Complete in all respect |
| 52 | Add Transportation Charges Complete in all respect |
| 53 | HT Line |
| 54 | Prov.X-Arm (Horizontal) - MS Channel Iron: 100X50x5, Length: 2340mm x 2 Nos |
| 55 | Prov. X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No. |
| 56 | Prov. Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No. |
| 57 | Prov. Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps, Straight stapples & Bend Stapples etc.) x (3 No. conductors) x (2 No. sides) |
| 58 | Prov. 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure( Insulator suitable for heavily polluted area) |
| 59 | Prov. Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures |
| 60 | Prov. Stay set complete in all respect( i/c Stay Clamp) (4No. / Dead Structure & 2 No./Run Thro.) |
| 61 | Prov. 6 SWG GI wire For Earthing |
| 62 | Prov. MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos |
| 63 | Prov.Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 3% (Sag, Earthing, Cross lacing above road wastage and for connecting with earth coil))} @ 0.102 kg/m |
| 64 | Prov.Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m} |
| 65 | Prov. Eye Hook for earth wire |
| 66 | Prov. Half clamps |
| 67 | Prov. Full clamps |
| 68 | Prov. Danger Plate (250X200X1.6mm) |
| 69 | Prov. D.O Fuse Unit |
| 70 | Prov. GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type |
| 71 | Prov. X-Arm: [Channel Iron (75x40x4.8 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch |
| 72 | Prov. GO Switch Handle Supporting: [Channel Iron (75x40x4.8 mm), Length : 460 mm |
| 73 | Add: [Cost of Optional Miscellaneous Items (Protective Gear i.e 11 kv insulated rubber handler gloves (EN-60903 & IEC-60903) |
| 74 | Add Erection Charges Complete in all respect |
| 75 | Add Transportation Charges Complete in all respect Please Enable Macros to View BoQ information |