| 1 | Material and labour for taking down Window type air conditioner of any type/make/capacity after disconnecting all electric connection from site (either in ground / any floor), transporting to work site if required, cleaning of air filter, front panel, suction grill, De-dusting of coupler unit, checking electrical connection, cleaning the condenser, brush cleaning the whole unit with electric blower, cleaning with water, descaling with non corrosive acid on both side of cooling coil and components, identifying the fault/ trouble in the unit and their redressal, reassembling and refixing the covers and making electrical connections, installation the machine in same position, testing and commissioning complete all as specified and as directed by Engineer-in-Charge (Note: Repair/Replacement of the component required shall be paid under relevant item of schedule here-in-after). (Note:- For Sl No 1 - 112, if any complain not rectified within 24 hrs with user's satisfactory working report penalty of Rs 500 per defect per day shall be recovered from the contractor in FB) |
| 2 | Supply & Fix in repairs air filter elemant pads for window type A/C for 1.5 TR/ 2 TR of size and make during the maintenance complete all as specified & as directed by Engineer-In -Charge. |
| 3 | Supply & Fix in repairs louvers swing motor suitable for window type AC of cap 1.5/2.0 ton cap in situ as per existing make and compatible model, necessary electrical connection and testing after fixing to entire satisfaction of user and Engr-in-Charge. |
| 4 | Supply and fix in repairs blower drum, suitable for window type AC 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed by Engineer-in-Charge |
| 5 | Repairs to Micro-processor electronic circuit board (PCB) suitable for 1.5/2.0 ton window type AC including disconnection and taking out unsv PCB and and fixing after repairs, testing complete as per existing make/model complete all as specified & as directed by Engineer-In -Charge. |
| 6 | Supply & Fix in repairs Condensor fan motor double shaft 1/6Hp, 1/8Hp, 1/10Hp for Window type AC of 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and directed by Engineer In Charge |
| 7 | Supply & Fix in repairs blower motor single phase AC 200/230 volts suitable for window type A/C for 1.5 TR/ 2 TR complete all as specified & as directed by Engineer-In -Charge. |
| 8 | Supply & Fix in repairs Air filter suitable for window type AC 1.5 /2.0 TR capacity as per existing make and model complete all as specified & as directed by Engineer-In -Charge. |
| 9 | Supply & Fix in Repairs new sealed unit compressor of 1.5 TR window type room air conditioner (Make: As Per Exisiting or Equivalant) complete all as specified & as directed by Engineer-In -Charge. Note - Cost of Refrigerant gas and Gas charging is deemed to be included in the unit rate quoted of this item. |
| 10 | Supply and Fix in Repairs new sealed unit compressor of 2.0 TR window type room air conditioner (Make: As Per Exisiting or Equivalant) complete complete all as specified & as directed by Engineer-In -Charge. Note - Cost of Refrigerant gas and Gas charging is deemed to be included in the unit rate quoted of this item. |
| 11 | Supply & Fix in repairs Condenser coil unit of window type AC of cap 1.5 / 2.0 ton cap in situ as per existing make and competable model, connecting necessary copper tubings by brazing after dismentling/taking out existing unserviceable condenser unit & Fixing New Condenser Coil any Make/model and testing after completion to entire satisfaction of Engr-in-Charge. |
| 12 | M & L Gas Charging and Repairs to window AC of unit 1.5/2 T capacities after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, identifying the leakage in the unit, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a or any other) and non freezing oil achieving desired cooling. Testing the equipment for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge.(Note- Refrigerant will be issued under respective Item of this Schedule) |
| 13 | Material and labour for shifting of window type AC of any capacity and make after taking down of all electrical connection, closing existing window AC alocation with brick/PCC work and carrying it to the new location and cutting the existing window including additions/alterations to make suitable opening for fixing including welding/wood work as per site requirement to match with adjoining/existing surfaces and Refixing the window type air conditioner to the new altered location and making electrical connections, installation testing, commissioning and making good the disturbed surface to match with the existing surfaces complete all as specified and as directed by Engineer-in-Charge. |
| 14 | Material and labour for taking down split type air conditioner of any type/make/capacity after disconnecting all electric connection from site (either in ground / any floor), transporting to work site if required, cleaning of air filter, display, PCB, de-dusting of complete indoor/outer unit, washing condensor unit with suitable water spray jet, checking electrical connection, brush cleaning the whole unit with electric blower, cleaning with water, decaling with non corrosive acid on both side of cooling coil and components, identifying fault/ trouble in the Indoor and Outdoor unit and their rectification/ redressal, rewiring, grasing of movable part for getting trouble free servicing, refixing the covers and making electrical connections, installation the machine in same position, testing and commissioning complete all as specified and as directed by Engineer-in-Charge (Note: Repair/Replacement of the component required shall be paid under relevant item of schedule here-in-after) |
| 15 | Supply and fix in repair condensor coil of copper suitable for 1.5 TR/2 TR split type air conditioner including taking down old unserviceable condensor coil from existing position complete all as directed and specified by Engineer-In Charge |
| 16 | Repairs to micro processor Circuit of existing Printed Circuit Board (PCB) in Non-Invertor Split type AC of any make, complete all as specified & as directed by Engineer-In -Charge. |
| 17 | Repairs to micro processor Circuit of existing Printed Circuit Board (PCB) invertor Split type AC of any make, complete all as specified & as directed by Engineer-In -Charge. |
| 18 | Supply and fix in repairs blower drum suitable for split type AC 1.0 Ton/1.5 Ton/2.0 Ton complete all as specified and as directed by Engineer-in-Charge |
| 19 | Supply and fix in repairs New Micro-processor Printed Circuit Board (PCB) For Non-Invertor split A/C of as existing sample/make or equivalent ,complete all as specified & as directed by Engineer-In -Charge. |
| 20 | Supply and fix in repairs New micro processor Printed Circuit Board (PCB) For Invertor Split A/C of make as existing sample ,complete all as specified & as directed by Engineer-In -Charge. |
| 21 | Supply and fix in repairs Indoor blower motor single phase AC 200/230 volts suitable for split model A/C of capacity 1.5 TR/2 TR (Make - As per Existing Make or equivalent), complete all as specified & as directed by Engineer-In -Charge. |
| 22 | Supply and fix in repairs Heavy duty air conditioner outdoor unit stand/ brackets with complete accessorise for window/split AC of capacity of 1.5/2 Ton complete with grouting nut bolts all as specified and as directed by Engr-in-charge . |
| 23 | Supply and fix in repairs contactor switch suitable for existing multi (3 TR Unit) split type unit complete all as specified & as directed by Engineer-in Charge.(Make. Blue star,Schnieder) |
| 24 | Supply and fix in Repairs Suction valve for split AC of any capacity. |
| 25 | Supply and fix in Repairs Discharge valve for split AC of any capacity. |
| 26 | Supply and fix in repairs Condensor fan motor 1300rpm with fan blade, 1/3 Hp, 1/6Hp, 1/8Hp, 1/10Hp for Split type Air Conditioner outdoor unit of 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and directed by Engineer In Charge |
| 27 | Supply and fix in repair copper tubes 2 mm thick for additional length required in the process of maitenance of the split air conditioners unit, with insulation of puff or TF quality of thermocole or poly urithine insulating tubes all as specified for 5/8 inch copper tubing complete all as specified & as directed by Engineer-In -Charge. |
| 28 | All as per item No 27 here in above but of size 1/4 inch |
| 29 | All as per item No 27 here in above but of size 1/2 inch |
| 30 | All as per item No 27 here in above but of sizer 3/8 inch |
| 31 | Supply and fix in repair flexible cord PVC insulated and sheathed 3 core flexible with copper conductor of size 2.5 sq mm complete all as specified & as directed by Engineer-In -Charge. |
| 32 | Supply and fix in repairs 240 volts 32 amps capacity MCB single pole after taking out old unserviceable MCB from existing position Make - Standard/Havells/Legrand complete all as specified & as directed by Engineer-In -Charge. |
| 33 | M&L in replacement of air filter made out of nylon wire mesh moulded in plastic complete suitable for existing old filter's size and shape, as directed for 1.5/2 TR capacity of split type AC complete all as specified and as directed. |
| 34 | Supplying and fix in repair sheet metal enclousers with socket, plug top and MCBs, single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB , single pole, 240 V of capacity 20 amps , complete all as specified and as directed by Engr-in-Charge. |
| 35 | Supply and fix in repairs Air filter suitable for indoor unit of split type AC 1.5 /2.0 tr capacity as per existing make and model. |
| 36 | Supply and fix in repairs Fibre reinforced PVC drain pipe suitable for split AC out let of 1.5T/2.T capacity. Please Enable Macros to View BoQ information |
| 37 | Supply and fix in repairs Fibre reinforced PVC drain pipe suitable for split AC out let of 1.5T/2.T capacity. Please Enable Macros to View BoQ information |