| 1 | Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-55 (11.0 Metre long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of Aluminium Primer (Externally from Top of Coping) including writing MES Pole No. with synthetic Enamel Paint (First Grade/quality), complete all as specified and as directed. |
| 2 | M&L Stay Assembly complete with Accessories as show in Electrical Plate No. 1 of MES Schedule Part-I, diameter of Stay Rod 20mm, including 7/4.00 mm Galvanised Stay Strand, complete all as specified and as directed.NOTE: Earthwork, Cement Concrete, Mild Steel Stay Clamps with Bolts, Nuts, etc., Loop Insulator, etc. will be measured and paid under appropriate Items. |
| 3 | M&L Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed. |
| 4 | Re-fixing only Cross-arms, Bracings, Supports, Clamps and Back Plates (serviceable materials i.e. Structural Steel Sections obtained from Item No. 7 here-in-before) including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed. |
| 5 | S&F Insulator Pin type Polymer, including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, for 11 KV grade, complete all as specified and as directed |
| 6 | S&F Pin type insulator polymer suspension type , for tension with Tension Clamps for conductors working pressure 11KV, complete all as specified and as directed. |
| 7 | S&F Loop Type Insulator Vitreous White, Brown or Green, large size with overall dimensions 90x140mm, clearance of hole 25.50 mm dia, complete all as specified and as directed. |
| 8 | S&F AAAC covered Conductor (ACSR) 100Sqmm with permissible Sags and providing Jumper, etc., fixing on Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc., complete all as specified and as directed.NOTE : Cost of Binding Wire is deemed to be included in the quoted Unit Rate. |
| 9 | Supply and installation for GI top cleat (100 x 50 x 6 x 350) mm for 11 KV complete all as specified and as directed |
| 10 | Supply and installation for termination kit for 11 KV-IC 100 sqmm AAAC covered conductor complete all as specified and as directed |
| 11 | Supply and installation for MVCC mid span jointing kit accessories mid span jointing kit for 11 KV IC 100 sqmm AAAC covered conductor complete all as specified and as directed |
| 12 | Supply and installation for tension hardware 11 KV IC 100 sqmm AAAC covered conductor complete all as specified and as directed |
| 13 | Supply and installation for tension insulator 11 KV IC 100 sqmm AAAC covered conductor complete all as specified and as directed |
| 14 | Supply and installation for piercing connector 11 KV IC 100 sqmm AAAC covered conductor complete all as specified and as directed |
| 15 | Supply and installation for cable tie 11 KV IC 100 sqmm AAAC covered conductor complete all as specified and as directed |
| 16 | Material and Labour for Earthing complete with Galvanised Steel Earth Plate Electrode 600 x 600 x 6mm, thick buried directly in ground ( earth pit not less than 2.25 Metre deep below the Ground Level ) with Top Edge of Earth Plate not less than 1.50 Metre deep below normal ground level , connected to Galvanised steel iron strip earth lead 32x6 mm by means of Bolts, Nuts, Check Nuts and Washers made of Galvanised Iron 20 mm dia GI Pipe (Med grade) for watering, 40 mm dia GI Pipe light grade for protection of earth strip, including necessary earth work in any type of soil , PCC (1:3:6) Type C1 Concrete pit RCC (1:1.5:3) Type A1 Precast cover (54x54x5Cm) duly reinforced with including 8mm Dia TMT Bar @ 150 mm c/c both ways lifting handle made of 8mm dia TMT Bar embedded in precast cover slab complete as shown in electrical Plate No 3 of SSR Part-I including testing on completion complete all as specified and as directed. |
| 17 | Excavation in Trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/Pole/Stays etc getting out in Soft/Loose Soil, complete all as specified and as directed. |
| 18 | Excavating in Trenches, not exc. 1.50 Metre wide and exc. 1.50 Metre but not exc. 3.00 Metre in depth, for Foundation of Poles/ Stays, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed. |
| 19 | M&L Cement Concrete 1:3:6 (40mm graded aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as/if required) complete all as specified and as directed. |
| 20 | Removing Surplus Soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed. |
| 21 | Returning, Filling in including Spreading, Levelling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed. |
| 22 | M&L Cement Concrete 1:4:8 (40mm graded aggregate) as Lean Concrete in Foundation of Poles, Stay Assembly, etc., including Formwork (as/if required), complete all as specified and as directed. |
| 23 | M&L Cement Concrete 1:2:4 (20mm graded aggregate) as in Coping of Poles, etc. and finishing the Concrete surfaces Fair and Even including necessary Formwork required at Site(s), complete all as specified and as directed. Please Enable Macros to View BoQ information |