| 1 | Transportation of Rig machine, drilling equipment. T&P including errection of rig machine & dismentling after completion of work etc. Complete. (M.R.) |
| 2 | Rate for drilling:- (M.R.) |
| 3 | 675 mm dia bore. |
| 4 | 525 mm dia bore. :- |
| 5 | Beyond 60 to 100 M. BGL. |
| 6 | Beyond 100 to 150 M. BGL. |
| 7 | Beyond 150 to 200 M. BGL. |
| 8 | Rate for tubewell liner assembly (ERW pipe) Make Tata/Jindal |
| 9 | Housing MS pipe 350 mm dia 8 mm thick. |
| 10 | Blind MS pipe 200 mm dia 8 mm thick. |
| 11 | Slotted MS pipe 200 mm dia 8 mm thick. |
| 12 | M.S. reducer 350x200mm dia 8 mm thick. |
| 13 | M.S. socket/ Ring 350 mm dia 8 mm thick. |
| 14 | M.S. socket/ Ring 200 mm dia 8 mm thick. |
| 15 | M.S. Bail plug 200 mm dia. |
| 16 | M.S. housing clamp heavy duty 350 mm dia. |
| 17 | M.S. tube well cap. 350mm dia |
| 18 | Lowering of tube well assembly (M.R.) |
| 19 | Supply of pea gravel. (M.R.) |
| 20 | Development of tube well by 250 PSI air compressor. (M.R.) |
| 21 | Development of tube well by 3.5 To 4.5 Cusec O.P. Unit. (M.R.) |
| 22 | Electric logging and resstively Test of bore by bogging. (M.R.) |
| 23 | Bantonite powder if required while drilling of bore hole. (M.R.) |
| 24 | K.S.B. Make submersible Pump. 1100 L.P.M. 67.00 mtr head |
| 25 | K.S.B. Make submersible Pump. 1200 L.P.M. 79.00 mtr head |
| 26 | Auto Transformer Starter for submersible pump |
| 27 | Submersible cable 1x3x10 sq.mm. |
| 28 | Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 mtrs. Below grouynd level complete PWD SOR 2018, SI No. 702 |
| 29 | Danger board |
| 30 | C.I.D.F. sluice valve 150 mm ( Make kirloskar/I.V.C ) |
| 31 | C.I.D.F. non return valve 150 mm( Make kirloskar/I.V.C ) |
| 32 | C.I.T.F Tee for 150 mm dia MS Pipe |
| 33 | C.I.D.F bends 90 degree for 150 mm dia MS Pipe |
| 34 | M.S. clamp 150 mm dia MS Pipe |
| 35 | Safty guard/ crossing ring |
| 36 | Cutting of housing cove |
| 37 | Nut, bolt and washer |
| 38 | Rubber packing |
| 39 | M.S.D.F. pipe 150 mm dia column for M.S Pipe. |
| 40 | MSDF Pipe 150 mm dia 1.50 mtr long |
| 41 | MSDF Pipe 150 mm dia 1.00 mtr long |
| 42 | Painting. |
| 43 | Pressure and depth gauge as per SE approved rate letter attech |
| 44 | Lifting tackle. |
| 45 | Tools as per SE approved rate letter attach |
| 46 | Errection charge. |
| 47 | Testing and commissioning. |
| 48 | Running period. |
| 49 | Supply of of Electronic Chlorinator of 6 LPH Capacity complete with accessories and PVC Solution Tank |
| 50 | Supply of Orifice Plate (150 mm dia) |
| 51 | Supply of Sodium Hypochlorite (70 Ltr. Drum) |
| 52 | Installation Charges |
| 53 | Cartage |
| 54 | 63 KVA 11/0.433 kV Transformer |
| 55 | Supply and errection of Double pole 11 Mtr. long 410 SP-55 ST pole support duly grouted with 1:4:8 cement concrete (1-cement , 4fine sand and 8-OBB of 40mm. nominal size) including plinthing with 20 mm. nominal size stone grit 10 Cm. Below the G.L. and 30Cm. Above the G.L. and plastering with 1:4 cement mortar, plastered and painted in the same manner as already specified for respective supports suitable for Plinth mounted type substation with different types of M.S. channels and angle iron duly fabricated for Disc. fittings D.O. fuse set, TPMO, outside dropper & bracing's including cost of material,labour and T&P required for proper completion of work as per drawing and direction of E/I. |
| 56 | (i)ST GI BOTTOM Pole SP -55 , 11.00 mtr Long |
| 57 | S/f of 11 KV, TPMO set complete With all material, labour and T&P required for Proper completion of the work. |
| 58 | S/f of 11 KV, D.O. fuse set complete With all material, labour and T&P required for Proper completion of the work. |
| 59 | S/f of 11 KV, Lighting Arrester set complete With all material, labour and T&P required for Proper completion of the work. |
| 60 | S/F of Barbed wire 1.5 Kg. Duly clamped with 2 No. clamps made of 20 x 3 mm at both end on poles, flate including bolts, required for nuts and washer complete with all material labour and T&P etc. for proper completion of work. |
| 61 | Supply and fixing of H.T/L.T. jumpering and connections on double pole/four pole. Lighting arrestor and transformer. The rates include the cost of all materials, labour and T&P etc. required for proper completion of work. |
| 62 | Making suitable earthing of ST poles /Double pole/ Section End Double pole with 2.5Mts. long 20mm dia M.S. rod with 7/16 SWG G.S. wire in 15mm dia 2Mtr. long G.I. pipe duly clamped with 3 nos clampes and binding on poles including cost of labour & T & P etc. required for proper completion of work. |
| 63 | Supply, delivery, testing and commissioning of 11KV (E) XLPE cable having compacted circular stranded aluminium conductor, conductor screening of extruded semi conducting compound. Cross linked polythylance (XLPE) insulation screening of the extruded semi conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to IS: 7098/Part-II/ with latest ammendment for following mentioned sizes. (120 sqmm LT Cable Laying in HDPE pipe) Complete in all respects. Make:- PolyCab, Gloster, Havells, KEI ) . |
| 64 | (i)3x120 sq mm 3 core. |
| 65 | Supply of HDPE pipes (upto PN 6 Kg Pressure Rating material Grade PE 80, Pressure Rating PN 6.0) as per relevants IS suitable for HT / LT XLPE cable. (Make :- Sudhakar, Creator Poly Extrusions LLP, Supreme, Josexim) |
| 66 | (i) 90 mm dia HDPE Pipe |
| 67 | Drilling of road crossing at depth 1.5 to 2 mtr as required and laying charges of cable in 90 mm dia HDPE pipe. complete with all material, labour, drilling machine and T&P etc. required for proper completion of work. |
| 68 | For 90 mm dia HDPE pipe |
| 69 | Supply, Delivery, Installation, Testing & Commissioning of 11 KV Straight through cable jointing kit of 3 core cable jointing Complete in all respects as required for proper completion of work. (make:- Raychem/ Dension/ 3M) As per DSR-2022, 10.6.3 |
| 70 | 3C x 120 sq.mm. |
| 71 | Supply and jointing of Out-door type 11 KV Jointing Kit (HEAT SINK) for 3 core HT XLPE cable including cost of all material labour T&P etc. as per proper completion of work. (Make:- Raychem/ Dension/ 3M). |
| 72 | Outdoor type DSR-2022, 10.5.2(i)120 sq mm outdoor type Jointing Kit |
| 73 | Supply, Installation, Testing, commissioning of Out door type Transformers 63 KVA, 11/0.433 kV \\"Energy Efficient(Level -1)\\" including Loading, unlaoding, local carriagewith all material, labour, T&P required for proper completion of the work. (Make: Transtron/ Elecon/ Paramax/Asian) - .- |
| 74 | (i)63 KVA Aluminium wound |
| 75 | Supply and burring of safe Earthing Electrode T-39, Zn-Zinc Coated , Length 3000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mmX2.6mm terminal Dia, 12 mm Coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of rataining capacity along with 30 cm square C.I. Frame with hinged cover & masonry housing (From electrode terminal to switch board, cost of 25x3 G.I. strip will be extra) Make:- As approved in U.P.P.W.D., & C.P.R.I. Certified. As per PWD SOR-2018 SI No-726(D) |
| 76 | Supply and laying of aluminium conductor (LT Cable) PVC insulated armoured served sheathed cable 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top on surface. complete in all respect. (Laying in HDPE Pipe) (Make:- Polycab, Gloster, Havells, KEI). . |
| 77 | (i) 70 sq. mm 3.5 Core(PWD SO-2018 Sl No. 501(m)) |
| 78 | Supply and fixing of plain or pin type copper tin plated cable socket (Lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of E/I. UP PWD SOR-2018 SI No-504 |
| 79 | (i) 35 Sq.mm. |
| 80 | (ii) 70 Sq.mm. |
| 81 | S/F of G.I. Pipe of following sizes for DP cable duly clamped with supports by 3 No. with clamps of 20 x 3 mm M.S. flats bolts, nuts and washer required for proper completion of work.(Make:- Jindal/ Tata/Prakash). - .- |
| 82 | (i)100 mm dia |
| 83 | Supply and Fixing of Wooden Meter Board. As per latest guidelines of UPPCL. |
| 84 | Supply and Fixing of 200 Amp. Kit-Kat fuse unit. |
| 85 | Neutral link 100 Amp. |
| 86 | S/F of Danger board of size 200 x 250 x 1.6 mm of M.S. sheet fixed with clamp of 20 x 3 mm M.S. flate including bolts, nuts and washer duly painted completed with all material, labour and T&P etc. required for proper completion of work. |
| 87 | Supply and Fixing of Cable Route Marker with cement concrete 1:2:4 (1 cement : 2 corse sand : 4 graded stone aggregate 20 mm nominal size ) of size 1000x400x100 mm in suitable masonry enclosure as directed by E/I. Please Enable Macros to View BoQ information |