| 1 | STREET LIGHT WORK |
| 2 | Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70 mm, Bottom dia 155 mm and base plate 16 mm thick) having 3 mm thikness with sword type Double arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of 3 phase 4 way connector with backlite sheet/MCB in G.I. Pole, foundation, excavation & back filling and Required T&P complete in all respect with 2 coat of white cement on foundation. [MAKE:- Bajaj/ Philips/ Valmont/ VPST/ KesclacSchreder] |
| 3 | Making suitable earth of H.T. overhead line pole with 2.5 Mts. long 20mm M.S rod connected with 7/16 SWG G.S. wire duly clamped & binded on pole including the cost of materials, labour and T & P required for proper completion of work as per direction of E/I. |
| 4 | Supply and fixing of LED Street light Fitting with mandalory driver set having die cast aluminium body with toughend giass/UV stabilized PC Cover and lenses suitable for 175 Watt and Confirming to IP 66, and IK07 and above protection having Company LOGO Engraved complete in all respect including Labour ,19200-21000 system lumens, High Power LED with lenses 120 Lm/W, PF>0.95, THD <10% at full load, CRI > 70, Potted driver Set in Metal housing (Not Circuitory) Phase to phase, Protection at 440V & >300V auto cut and re-start feature, 4 KV internal Sürge Protection, with 5.years warrantee. [Make:- Polycab/Havells / Philips/ Jaquar/ Crompton] |
| 5 | Supply and fixing of 16 mtr. High mast shaft of approved make with rising system hot dip glavanized inside & out side dip, heaving pole sheet thickness 4mm. Top dia minimum 150 mm, bottom dia minimum 360mm, base plate 32mm thick, suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 6mm dia, double drum winch. including Aviation Light & making suitable foundation as per manufature drawing/site reuiment along with foundation bolts nuts, washers, anchor plates etc complete in all respect. with 2 coat of white cement on foundation. [MAKE:-Bajaj/Philips/Valmont/VPST/ Kesclac Schreder] |
| 6 | Supply and ſixing of factory wired integral LED flood light luminaires with die cast aluminium housing with toughend: glass UV stabilized PC Cover and lenses built with mandatory driver set suitaisle for 200 Watt. Confirming to IP 66, IK 07 and above protection compiete in all respect including Labour. 20400-24000 system Lumens, High power LED with lenses, >120 Lm/W, P.F.>0.95, THD <10% at full load, CRI >70, Potted driver Set in Metal housing (Not Circuitory) Phase to phase Protection a: 440V & >300V auto cut and re-start feature, 4 KV internal Surge Protection, with 5 years warrantee. [Make:- Polycab/ Havells/ Philips/ Jaquar/ Crompton] |
| 7 | Supply and Laying of Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc [Make:-Havells/Polycab/Grandlay /KEI] |
| 8 | 16 Sqmm 4 core |
| 9 | 35 Sqmm 3.5core |
| 10 | S/F of HDPE pipes (upto Pn 6kg pressure Rating material Grade PE 80, Nominal Dia (OD) 40mm 2.7 mm thicknes for cable Complete in all respect as per relevants IS Technical Specification. |
| 11 | Drilling of road Parallely & road crossing at depth 2 to 3 mtr as required and laying charges of cable & Diffrent size HDPE pipe (PN-6, PE 80 grade) complete with all material, labour, drilling machine and required T&P etc. |
| 12 | Supply & fixing of M.S. Saddle Clamp, Nut, Bolt etc. Complete in all respect As per direction of E/I. |
| 13 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN. complete in all respect. [Make-Havells/Schneider/HPL/ABB ] |
| 14 | 15 A TPN |
| 15 | 25 A TPN |
| 16 | Road Cutting |
| 17 | External Electrification Work |
| 18 | S/I/T/C with Loading & Unloding of 63 KVA, 11/0.433 kV \\"Energy Efficient\\" (Level-2) (Amended Level-1) Aluminium Wound, out door, Delta- Star, Distribution Transformer as per B.I.S. 1180-2014 Standards and lateest Specification of D.V.V.N.L. . [MAKE :- ONLY THOSE MANUFACTURER WHOSE G.T.P. IS APPROVED IN DVVNL & HAVING VALID TYPE TEST BY CPRI/ERDA AND NOT BLACK LISTED WITHIN 7 YEARS IN D.V.V.N.L] |
| 19 | S/F of following type of G.I. pipe \\"C\\" class for cable clamped with supports by 3 Nos. clamps made of 20x2.5mm M.S. flat and suitable size of nut bolt and washer required for proper completion of work as per direction of E/I. [MAKE :- TATA/SAIL/JINDAL] |
| 20 | 65 mm dia . |
| 21 | 40 mm dia . |
| 22 | Supply and erection of double pole structure made of following types of support duly grouted in 1:4:8 cement concrete (1 cement, 4 coarse sand and 8 grit of 20mm nominal size plinthed plastered & painted in the same manner as already specified for respective supports suitable for plinth mounted type substation with different types of M.S. Channel and angle iron duly fabricated for disc insulator fittings, D.O. fuse set, TPMO ladder stand projecting outside, dropper and bracings , including cost of all material, labour and T & P required for proper completion of work as per drawing and direction of E/I. (as per specification no. 16) 11 Mts. long 410 SP 55 S.T. Pole Bottom section Galvanised with base plate. [MAKE :- ONLY THOSE MANUFACTURER WHOSE G.T.P. APPROVED BY D.V.V.N.L] |
| 23 | Supply and erection of 11 KV TPMO set complete in all respects. |
| 24 | Supply and erection of 11 KV D.O. fuse set complete in all respects. |
| 25 | Supply and fixing of H.T./L.T. jumpering and connections on double pole/four pole, lightning arrestor and transformer. The rates include the cost of all materials, labour and T & P etc. required for proper completion work. |
| 26 | S/F of lightening arrestor set (3 Nos.) suitable for mounting on steel supports complete with all materials, labour and T & P required for proper completion of work as per direction of E/I. |
| 27 | Supply and Burring of Safe Earthing Electrode T-39 Zn-Zinc Coated, Length 2000 mm, outer pipe 76.30 mm x 3.2 mm inner pipe 42.40 mm x 2.6, terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square CI frame with hinged cover & masonary housing.[Make: As approved in U.P.P.W.D., & C.P.R.I. Certified] |
| 28 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. |
| 29 | Supply and Laying of 70 Sqmm 3 Core stranded Aluminium Conductor XLPE (Cross linked polyethylene) insulated PVC bedded, galvanized flat steel strip armoured cables confirming to LS. 7098 (Part II with latest amendments) 11 KV grade at a depth of 900 mm below ground level over a cushion of 100mm thick fine rever sand all around and protected with well burit bricks on sides and on top put across as directed by Engineer in Charge complete in all respect including xcavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. [Make:-Havells/Polycab/Grandlay /KEI] |
| 30 | Supply and Laying of 120 Sqmm 3.5 Core Aluninium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the carth conductor by clamps etc [Make:-Havells/Polycab/Grandlay /KEI] |
| 31 | S/Laying of 2.5 Sqmm 2 Core control cable. [Make:-Havells/Polycab/HPL/Grandlay /KEI] |
| 32 | Supplying and making of 70 Sqmm 3 Core straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: [Make :- Reychem/ M-SEAL/Birla-3M] |
| 33 | Supply & Making of 70 Sqmm 3 Core Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as Required. [Make :- Reychem/ M-SEAL/Birla-3M] |
| 34 | S/F of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tap and making connection etc. complete in all respects as per direction of the E/I. |
| 35 | 16 Sqmm |
| 36 | 35 Sqmm |
| 37 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer- Incharge. |
| 38 | 35 Sqmm 3.5 core |
| 39 | 120 Sqmm 3.5 Core |
| 40 | Supply, Installation, Testing and Commissioning of outdoor type LT Panel verinin proof floor mounting, M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper slieet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating. The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartiment Design for Each Feeder as per 3b construction Forinat. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartinent for incomer metering and outgoing metering. |
| 41 | All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components, such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Amineter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type. Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire, All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/C Protection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA 'C' Curve. Cubicle type switch board shall be Cat-A and B only. [Make: As approved in U.P.P.W.D.] |
| 42 | Panel Board (MCCB Type) |
| 43 | Incoming |
| 44 | 100 Amp. MCCB 01 Nos |
| 45 | Outgoing |
| 46 | 63 Amp. MCCB 02Nos |
| 47 | Cat.-B Panel Cubicle Type Please Enable Macros to View BoQ information |