| 1 | Earthwork in surface excavation not exceeding 30 cm in depth butexceeding 1.5 m in width as well as 10 sqm on plan including getting outand disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer in Charge: |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level: |
| 3 | Filling available exacavated earth ( excluding Rock) in trenches ,plinth,sides of foundations etc in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming and watering lead upto 50 and for all lift |
| 4 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring and shuttering - All work upto plinth level: |
| 5 | Reinforced cement concrete work in walls ( any thickness),including attached pilasters,bultresses,plinth and string courses,fillets,columns,pillars,piers,abutments,posts and struts etc above plinth level upt floor five level, excluding cost of centering ,shuttering,finishing and reinforcement : |
| 6 | Reinforced cement concrete work in beams ,suspended floors,roofs having slope upto 15 landiings,balconis ,shelves,chajjas,lintels,bands,palin window sills,staircase and spiral stair cases above plinth level upto floor five level, excluding the cost of centering ,shuttering,finishing and reinforcement with 1:1.5:3 ( 1 cement :1.5 coarse sand (zone-III) derived from natural sources :3 graded stone graded aggregate 20 mm nominal size derived from natural sources) |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 8 | Suspended floors, roofs,Landings, balconies and access platforms |
| 9 | Lintels ,beams,plinth beams,girders,bressumers and cantilivers |
| 10 | Columns,Pillars,Piers,Abutments,Posts and struts |
| 11 | Steel reinforcement for R.C.C work including straightening ,cutting ,bending ,placing in position and binding all complete upto plinth level |
| 12 | Brickwork with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: |
| 13 | Half brick masonary with common burnt clay F.P.S ( non moudalar) bricks of class designation 7.5 in superstucture above plinth level upto floor V level |
| 14 | Providing and fixing stainless steel ( Grade 304 ) railing made of Hollow tubes,channels,plates etc.,including welding,grinding,buffing,polishing and making curvature ( wherever required|) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories & stainlesss steel dash fasteners,stainless steel bolts etc of required size on the top of the floor or the sides of waist slab with suitable arrangement as per approval of Engineer i n charge |
| 15 | 12 mm cement plaster of mix: |
| 16 | 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 17 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer ,over the plastered wall surface to prepare the surface even and smooth |
| 18 | Finishing walls with Premium Smooth Acrylic exterior paint with Silicon additives of required shade: |
| 19 | Providing an laying factory made chambered edge Cement Concrete paver blocks in footpath ,parks ,lawns ,drive ways or light traffic parking etc of required sterngth,thickness & size/ shape, made by table vibratory method using PU mould, laid in required colur & pattern over 50 mm thick compacted bed of sand ,compacting and proper embedding /laying of interlocking paver blocks into the sand bedding layer thriugh vibratory compaction by using palte vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern,finishing and sweeping extra sand complete all as per direction of Engeneer -in -charge |
| 20 | S/F of Glow Sign Bord I LOVE Achalganj |
| 21 | S/F of Submersible with all fittings |
| 22 | Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect.with led mount holder Si no 642 |
| 23 | Supply and fixing of LED Street light Fitting having die cast alluminium body and difuser with driver set suitable fo 45-50 watt (CAT-AAA). Confirming to IP 66 protextion complete in all respect.Si.No-1421 |
| 24 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. {Si. item no 501(i)} |
| 25 | Supply and burying earth electrode for lighting conductor of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe for watering funnel, 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineerin-charge complete in all respect. (Si no 706) |
| 26 | Supplying & Fixing of nature switch for automatic control of light sensitive electric circuit using space grade infra-red sensor to adjust automatically on-off adjustment. Time shall be adjusted as per personal variation of sunrise and sunset etc including connection to nearest electric pole i/c labour T&P etc complete as per directed by Er.In Charge.(as per MR) |
| 27 | For Gym Equipment |
| 28 | S/f of trees |
| 29 | S/f of Land Scape Grass |
| 30 | S/F of 100 watt Halogen |
| 31 | S/F of Gate Lights |
| 32 | S/F of Concealed Lights on Gate |
| 33 | S/F of Deep Lights |
| 34 | S/F of 4 Way Lights in B/Wall |
| 35 | S/F of Fan |
| 36 | S/F of 4 Nozzle fountain |
| 37 | S/f of 2 HP Motor at fountain |
| 38 | S/f of 4 water proof spot light |
| 39 | S/F of Swings |
| 40 | S/f of Shock Machine with wiring |
| 41 | S/f of MS Jaali |
| 42 | S/f of Bollard Lights Please Enable Macros to View BoQ information |