| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Repair/ replacement/ servicing of summer appliances and allied works at Mil Stn Beas, 2ASD and Jandiala Guru under GE Kapurthala Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | M&L for preventive maintenance/ servicing (Bi-Annual) cleaning of air filters, evaporator/condenser coils, blower fans, and drain pans using chemical wash/high-pressure air. Check refrigerant levels, gas leak test, motor greasing/oiling, electrical connections tightening, capacitor/thermostat testing, checking/removing any leakage & vibration in the window type AC of capacity 1/1.5/2 TR any make complete all as specified and directed by Engineer-in-Charge. Note - (i) Cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc, transportation of equipment to workshop and back is deemed to be included in the unit rates quoted by the contractor. (ii) Attend complaints within 8 hours, provide standby units if repair exceeds 48 hours. (iii) All complaint/repairs shall be attended/completed within 06 Hour failing which a recovery of Rs 500/- per day per complaint shall be made from contractor dues after intimation by rep of E/M sub div through telephonic/digital/ written complaints.(iv) Maintain logbook with unit no, date, complaints, with JE signatures after completion of wk.(v) All the parts included in this CA are paid separately under respective items of this schedule. |
| 3 | - ditto - all as per Item No. 01above but for split AC of capacity 1/1.5/2TR complete all as specified and directed. |
| 4 | S&F in replacement for Window/Split type AC upto 1/1.5/2 TR complete all as specified and as directed by Engineer-in-Charge for the following items |
| 5 | Starting relay |
| 6 | Over load protection relay |
| 7 | Thermostate switch |
| 8 | Blower motor 1/8 HP, double shaft, single phase |
| 9 | Fan Motor |
| 10 | Fan blade |
| 11 | Front grill size as per site |
| 12 | Capacitor 45 MFD |
| 13 | Capacitor 4 MFD |
| 14 | Capacitor 60 MFD |
| 15 | Capacitor 6 MFD |
| 16 | Universal power circuit breaker (PCB) |
| 17 | Outdoor Unit (ODU) Stand AC on wall with nuts, bolts & washers |
| 18 | Evaporator coil suitable for any type of AC as requred at site |
| 19 | Expansion valve |
| 20 | Condensor unit/cooling coil copper |
| 21 | Capillary tube |
| 22 | S&F in repairs of capillary filter |
| 23 | S&F in replacement Wiring kit or wiring harnes |
| 24 | Reversible valve with solenoid coil |
| 25 | M&L for carryout the pressure test with nitrogen gas of refrigeration system, detecting leakage including soldering and brazing of leaking copper tubing complete all as specified and directed. |
| 26 | Taking down, repairing and re-fixing main printed circuit board (PCB) with electric accessories and sensors suitable for inverter type split type AC/ window type AC all weather mode of any capacity and model complete all as specified and directed. |
| 27 | S&F in replacement, new compressor copper wound for Window/Split type AC 1.5 TR capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system complete all as specified and as directed by Engineer-in-Charge. Note: Compressor shall be tested to entire satisfaction of Engr-in-Charge and test results recorded and kept on charge. Gas will be measured and paid separately under respective item of this Schedule. |
| 28 | - ditto - all as per Item No. 06 above but for 2.00 TR capacity |
| 29 | Dismantling and refixing the split AC of 1.5/2 TR Including Drilling of holes into a brick wall for connecting Indoor with outdoor unit’s pipes and connecting indoor and outdoor units with copper pipes and installation of drainage pipes and fixing outdoor unit on separately ODU stand, Temperature & gas pressure testing, gas charging, carpentry work, Plumbing, masonry & white cementing complete all as specified & as directed. Note : Drain Pipe, Copper pipe of required size, Refrigerant gas , Outdoor stand , power plug, MCB and Copper wire will be paid under relevant items. |
| 30 | S&F in repairs 1.5 TR capacity new window type AC kit including compressor, condenser coil & evaporator coil (copper), copper wounded blower motor, cooling coil, front grill blower motor, chassis, base plate, reverse valve, capacitors and copper pipes & PVC wires of suitable size for internal connection etc including taking down old one complete all as specified and as directed for existing. |
| 31 | S&F in replacement new internal unit inbuilt complete for split type AC 1.5 Ton capacity, 5 star comprising of blower motor, fan blade with rotor, evaporator with suitable plasma filter, remote control system along with outer shell complete all as specified and as directed by Engineer-in-Charge. |
| 32 | S&F in repairs 1.5 TR capacity 5 star new inverter type split type Air Conditioner outdoor unit including condenser coil, blower motor, chassis, base plate , suction and discharge valve, contactor, capacitors and copper pipe, PVC wires, PCB compatible to indoor unit as above mentioned items 8, of suitable size for internal connection, etc. including taking down old unserviceable one complete all as specified & as directed |
| 33 | Supply and fix in replacement copper pipe including insulation pipe of dia 1/2 inch for split/window type AC for 2 ton complete all as specified and as directed by Engineer-in-Charge. |
| 34 | M&L for trickle charging of gas R-22 or as required in AC, any capacity, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contents trapped in the pipe line by charging CO2 gas and maintaining the pressure for prescribed period complete all specified. |
| 35 | M&L for trickle charging of gas R-32 or as required in AC, any capacity, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contents trapped in the pipe line by charging CO2 gas and maintaining the pressure for prescribed period complete all specified. |
| 36 | M&L for trickle charging of gas R-410 or as required in AC, any capacity, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contents trapped in the pipe line by charging CO2 gas and maintaining the pressure for prescribed period complete all specified. |
| 37 | S&F in repair/replacement of sheet metal enclosure with socket plug top & MCB single pole and neutral enclosure with a two pin and earth plug & socket complete with one single pole MCB 20/25 Amps. |
| 38 | S&F in repair/replacement of FRLS cable 1100Volts grade 3 core, 2.5sqmm, multirstranded Copper conductor, PVC insulated from main supply point to out door unit point all as specified and as directed. |
| 39 | M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper condutor, multi stranded cable of size 4.00 Sqmm 1100 volts grade drawn PVC concealed conduit of size 19/20 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good to disturbed surface of wall/floor/etc including one run of 4.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Three run of 4.00 Sqmm cable and one run of PVC Conduit shall be measured & paid as one unit.) |
| 40 | Supply, Install, testing and commissioning of voltage stabilizer having following features i .e. high power efficiency intelligant time delay system (3 mnts + /- 20 sec ITDS ) inrush current capacity etc for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 270 V with output voltage stabilized at 230V with accuracy of +/- 2.5% and of capacity 2.0 KVA compete all as specified and as directed by Engr-in-Charge. |
| 41 | Supply, Install, testing and commissioning of voltage stabilizer having following features i .e. high power efficiency intelligant time delay system (3 mnts + /- 20 sec ITDS ) inrush current capacity etc for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 270 V with output voltage stabilized at 230V with accuracy of +/- 2.5% and of capacity 5.0 KVA compete all as specified and as directed by Engr-in-Charge. |
| 42 | Disconnecting from mains and taking down for servicing of water cooler of capacity 40/80, 60/120, Litres including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing as required and installation in same location complete all as specified and as directed . |
| 43 | S&F in replacement over load protector relay suitable for 40/80, 60/120, Litres capacity water coolers complete all as specified and as directed . |
| 44 | S&F in replacement thermostat suitable for 40/80, 60/120, Litre capacity water coolers complete all as specified and as directed . |
| 45 | S&F in replacement condenser motor fan blade suitable for 40/80, 60/120, Litre capacity water coolers complete all as specified and as directed . |
| 46 | S&F in replacement PVC flexible drain Hose Pipe 40 mm complete all as specified and as directed . |
| 47 | S&F in replacement waste water tray complete suitable for 40/80, 60/120, Litre capacity water coolers complete all as specified and as directed . |
| 48 | S&F in replacement chromium plated push taps suitable for 40/80, 60/120, Litre capacity water coolers complete all as specified and as directed . |
| 49 | S&F in replacement PVC float valve of size 15mm dia complete suitable for 40/80, 60/120, Litre capacity water coolers including GI socket of same size complete all as specified and as directed . |
| 50 | S&F in replacement Starting Capacitor 25 mfd complete all as specified and as directed . |
| 51 | S&F in replacement running Capacitor 10 mfd complete all as specified and as directed . |
| 52 | S&F in replacement Starting relay suitable for 40/80, 60/120, Litre complete all as specified and as directed . |
| 53 | Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/16, 1/32 HP from water cooler cap. 4080, 60/120, Litre and S&F with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as specified & as directed. |
| 54 | Dismantling and removing defective compressor and S&F in repairs new sealed compressor of approved make obtained from authorised dealers, commissioning and testing of water coolers of 40/80 Litres capacity complete all as specified and as directed. |
| 55 | Dismantling and removing defective compressor and S&F in repairs new sealed compressor of approved make obtained from authorised dealers , commissioning and testing of water voolers of 60/120 Litres capacity complete all as specified and as directed. |
| 56 | Disconnecting the mains and taking out the unserviceable condenser coil and supply & fixing new condenser coil as per existing size & patterns for water coolers of capacity 60/120, Litres complete all as specified & as directed. |
| 57 | Disconnecting the mains and taking out the unserviceable condenser coil and supply & fixing new condenser coil as per existing size & patterns for water/coolers of capacity 40/80 Litres complete all as specified & as directed. |
| 58 | Dismantling the evaporator/cooling coil of water cooler capacity 60/120 & 40/80 Litres, checking the leakages of gas and rectify the leakages by brazing or as other manner complete all as specified & as directed |
| 59 | Taking down unserviceable PVC connection pipe and S&F of PVC connections 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed. |
| 60 | Dismantling and removing defective compressor and S&F (in repairs) new sealed compressor of approved make obtained from authorised dealers and commissioning and testing of refrigerators of 165 to 280 Litres capacity complete all as specified and as directed. |
| 61 | Dismantling and removing defective compressor and S&F (in repairs) new sealed compressor of approved make including charging of refrigerant gas R-22/134A, commissioning and testing of refrigerators of 280 to 500 Litres capacity complete all as specified and as directed. |
| 62 | Disconnecting from mains and taking down for servicing of refrigerator of capacity 165/180/195/250/310 and 330 Litres including detecting the leakage of gas and cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs etc; and keeping the refrigerator unit in satisfactory working condition after necessary servicing as required complete all as specified and as directed . |
| 63 | Supply and filling refrigerant gas R-134A/R32/R410/R600 in refrigerators/ deep freezers/ water coolers of any capacity, model and make complete all as specified and as directed . |
| 64 | M&L for detecting the leakage of gas of refrigerators/ deep freezers/ water coolers at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition complete all as specified & as directed. |
| 65 | S&F in replacement capillary tube of existing size including necessary brazing suitable for 165/300 litres capacity refrigerator complete all as specified & as directed (Make :- As per Sample). |
| 66 | S&F in replacement overload protector relay suitable for 165/300/310 litres capacity refrigerator complete all as specified and as directed . |
| 67 | S&F in replacement thermostat suitable for 165/300/310 litres capacity refrigerators all complete all as specified and as directed . |
| 68 | S&F in replacement vegetable basket with glass suitable for 165/300/310 litres capacity refrigerators complete all as specified and as directed . (Suitable for Whirlpool/ LG/Samsung/ Godrej refrigerator). |
| 69 | S&F in replacement PVC defrost tray as per sample suitable for 165/300/310 litres capacity refrigerators complete all as specified and as directed . (Suitable for Whirlpool/ LG/Samsung/ Godrej refrigerator). |
| 70 | S&F in replacement door gasket for refrigerators of capacity up to 250 Litres complete all as specified and as directed (Suitable for Whirlpool/ LG/Samsung/ Godrej refrigerator). |
| 71 | S&F in replacement door gasket for refrigerators of capacity more than 250 Litres but up to 310 litres complete all as specified and as directed. |
| 72 | Disconnecting from mains and taking down for servicing of Deep freezer of Capacity 165/180/195/310/330/450 and 500 Litres including detecting the leakage of gas and refilling of refrigerant , cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition after necessary servicing as required complete all as specified and as directed. |
| 73 | S&F in replacement starting relay 1/6 HP open with OLP complete all as specified and as directed . |
| 74 | S&F in replacement starting relay for 1/8 HP open type with OLP complete all as specified and as directed . |
| 75 | S&F in replacement over load protector relay suitable for up to 500 Litres capacity deep freezer complete all as specified and as directed . |
| 76 | S&F in replacement running capacitor for up to 500 Litres capacity deep freezer complete all as specified and as directed . |
| 77 | S&F in replacement thermostat suitable for up to 500 Litres capacity deep freezer complete all as specified and as directed . |
| 78 | S&F in replacement starting capacitor for up to 500 Litres capacity deep freezer complete all as specified and as directed . |
| 79 | Taking down defective compressor of deep freezer of capacity Upto 300 Litres and any make and supplying and fixing new sealed unit compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capillary and testing complete all as specified and directed . |
| 80 | - ditto - all as per Item No. 58 above but of capacity above 300 Litres but up to 500 Litres deep freezer compressors. |
| 81 | S&F in replacement tubular heating element 1500 Watt, complete all as specified |
| 82 | S&F in replacement heating element 2000 Watt, complete all as specified . |
| 83 | S&F in repair heating element for solar water heater capacity 3000 watt, complete all as specified and as directed by Engineer-in-Charge. |
| 84 | S&F in replacement thermostat for Geyser of capacity 50 Ltr/25 Ltr complete all as specified |
| 85 | S&F in replacement safety valve for any capacity of Geyser complete all as directed. |
| 86 | S&F in replacement 15mm outer dia PVC connection for hot and cold water pipe 450mm long, with adaptors of brass jem nuts and rubber washers, both side complete all asspecified and as directed by Engineer-in-Charge. |
| 87 | S&F in replacement selector switch three speed (low, medium and high) suitable for desert coolers including taking out unserviceable selector switch complete all as specified and as directed by Engineer-in-Charge. |
| 88 | S&F in replacement 3 pin plug top 5 Amp |
| 89 | S&F in repairs metal clad socket of 20 Amps complete all as specified & as directed. |
| 90 | S&F in repairs of MCB SP 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and as directed. |
| 91 | M&L for taking down desert cooler of any type/size/model from any height / floor for servicing like changing of wood wool pads, kit motor, submersible pump, fan blade, front grill, wiring, capacitor, cleaning as specified and re-fixing to existing place after servicing work complete all as specified and directed. |
| 92 | S&F in replacement wood wool pad of suitable size for 24” sweep desert cooler, 01 Set comprising of 3 Nos of pads approximate weight 800-900 Gms as per sample complete all as specified & as directed. |
| 93 | S&F in replacement submersible pump motor 230 Volts, single phase, AC suitable for plastic body/steel body desert cooler complete all as specified and as directed. |
| 94 | S&F in replacement front grill for desert cooler of approved make suitable for fixing 5 Amp switch, three speed regulator and indicating lamp complete all as specified and as directed . |
| 95 | S&F in replacement running capacitor of 4 mfd capacity for desert/ water cooler complete all as specified and as directed. |
| 96 | S&F in replacement wire mesh for desert cooler pad (Set of Three) including taking down old one complete all as specified and as directed . |
| 97 | S&F in replacement PVC pipe for connecting pump and water distributor of size 15 mm dia including PVC elbows complete all as specified and as directed . |
| 98 | S&F in replacement PVC elbow for desert cooler of suitable size complete all as specified and as directed . |
| 99 | S&F in replacement PVC 4 Way distribution cross for desert cooler complete all as specified and as directed . |
| 100 | S&F in repairs of desert cooler kit fan motor, single speed, 230 V, 50 Hz of capacity 90 Watt 1450 RPM, copper wounded including nuts bolts for fixing complete all as specified and as directed. |
| 101 | S&F in repair desert cooler exhaust fan motor, single speed, 230 V, 50 Hz of capacity 150 Watt 1400 RPM, copper wounded including nuts bolts for fixing including taking down old unserviceable one complete all as specified and as directed. |
| 102 | S&F in repairs of flexible copper conductor cable, 3 core PVC insulated & PVC sheathed of size 1.5 Sqmm with permanently joined top of 15 Amps complete all as specified and as directed. (Length of wire about 1.5 meter) |
| 103 | S&F in repairs desert coolers fan blade of 18\\" (inch) sweep make out of Aluminium complete all as specified and as directed . |
| 104 | S&F in repairs switch piano flush type single pole one way 5Amp 230 V for desert cooler complete all as specified and as directed . |
| 105 | S&F in repairs cooler fan motor bracket sets made up as existing including painting complete all as specified and directed. |
| 106 | Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface, repainting the complete desert coolers i.e. side panel, bracket, body & desert cooler stand with two coats of synthetic enamelled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “ GE KPT (MES)” letter size of 50mm height at stencil in black/white including servicing and greasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as specified & as directed. |
| 107 | S&F in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) of sheet 22 Gauge and with side panels (03 Nos) fabricated out of 24 SWG PGI Sheet along with PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e., side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with \\"GE KPT (MES)\\" letter size of 50mm height in stencil in black/white complete all as specified & as directed. |
| 108 | M&L for for frame work with angle iron for frame support, with fabrication, welding joining including cutting tops to shape as directed, drilling holes, notching for wire flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 including taking down old unserviceable one complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |