Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala. 3rd Call Name of Work : Provision of 04xrooms along with toilet block near quarter gaurds of 1EW Bn Loc for Med Regt and provn of sorting out and Inspection shed of 106(I) comp pl ASC at New Mil Stn under GE Kapurthala. Contract No : GE KPT- /2025-26 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out soft/loose soil, including removal of excavated earth upto a distance 500m from starting point complete all as specified and directed by Engr-in-Charge. |
| 3 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundations etc or man holes, cesspits etc. not exc 10 Sqm on plan and getting out in soft / loose soil all as specified and directed by Engineer - in - Charge. |
| 4 | Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out , returning filling in layers not exceeding 25cm including watering and ramming and removing surplus earth to a distance not exceeding 50 metre complete all as specified. |
| 5 | M&L for cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate for foundations, fillings and mass concrete all as specified and directed by Engineer – in - Charge. |
| 6 | M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed by Engineer - in - Charge |
| 7 | M&L for PCC (1:5:10) type E2 using 40mm graded aggregate as in sub base and foundation filling complete all as specified and directed by Engineer-in-charge. |
| 8 | M&L form work to sides of concrete foundations, footings, bases of columns, and similar work etc for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge. |
| 9 | M&L form work to sides of pillars, posts, struts, piers, columns and stanchions square or rectangular for rough finished surface of concrete all as specified and directed by Engineer - in - Charge. |
| 10 | M&L form work to sides of soffits of plinth beams; lintels beams, roof beams and similar work for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge. |
| 11 | M&L for RCC M-25 as in foundation including raft, footings, foundation plinth beams bases of columns and the like complete all as specified and directed by Engineer - in - Charge. |
| 12 | M&L for RCC Design Mix M-25 (20 mm graded agg.) in Beams, cantilevers, bressummers, lintels over 1.5m span. |
| 13 | M&L for RCC (Design Mix) M-25 (20mm grade) as in columns, pillars, piers, posts and struts all as specified and directed by Engineer - in - Charge. |
| 14 | M&L forr form work to soffits of suspended slabs such as roof slab floor slab not exc 200mm thick with rough finished surface of concrete. |
| 15 | M&L for RCC M-25 as in slab supported on walls, beams and column in floor roofs landing the like complete all as specified and directed by Engineer - in - Charge. |
| 16 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregates finished even & smooth without using extra cement complete all as specified and directed by Engineer in charge. |
| 17 | M&L for 25 mm thick cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregates finished even & smooth without using extra cement complete all as specified and directed by Engineer in charge. |
| 18 | M&L forr vitrified ceramic light shade tiles 10 mm thick (square/rectangular) polished, area of each tile exc 0.42 Sqm and n exe 1.00 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, with 15 mm thick cement screed bed in CM (1:6). |
| 19 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11sqm but n.exc 0.18 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles including 15 mm thick cement screed bed in CM (1:6) Complete all as directed by Engineer-in-Charge. |
| 20 | M&L forr vitrified ceramic light shade tiles 10 mm thick (square/rectangular) polished, area of each tile exc 0.42 Sqm and n exe 1.00 Sqm in skirting and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, with 15 mm thick cement screed bed in CM (1:6). |
| 21 | M&L for glazed ceramic coloured tiles in vertical surface 300 x 450 x 7mm thick set and jointed in neat cement Paste pointed in white or colour cement to match the colour, including 10 mm thick cement screed bed (1:4) Complete all as directed by Engineer-in-Charge. |
| 22 | M&L for mild steel TMT bars10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as specified and directed by Engineer - in - Charge . |
| 23 | - ditto - all as per Srl item No. 21 here in before but 8mm dia and over as in stirrups, spacers and binders all as specified and directed by Engineer - in - Charge. |
| 24 | S & F rolled section Fe 410-W ( Gde-E-250) Quality-A as in framing for cladding, glazing and the like fixed angle cleat and connecting plates, etc complete all as specified and directed by Engr-In-charge |
| 25 | S & F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde-E-250) quality B complete all as specified and directed by Engr-in-Charge. |
| 26 | S&F Mild steel screw bolts 16mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm and n exc 30cm long complete all as specified and directed by Engr-in-Charge. |
| 27 | Use and waste of formwork to chajjas and similar items including edges rough finished complete all as specified and directed. |
| 28 | M&L for providing precast cement concrete 1:2:4 type B-1 (using 20mm Graded stone aggregated) as in manhole cover slabs brackets, etc. (of any section indicated), with plain fair faces, including necessary formwork complete all as specified and directed as by Engineer-in-charge |
| 29 | M&L forL RCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in chajjas , manhole cover , tank platform etc. complete all as specified and directed by Engineer-in-charge. |
| 30 | M&L for brick work with fly ash bricks (old size bricks) straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:4 complete all as specified and directed by Engr-in-charge . |
| 31 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 Complete all as directed. |
| 32 | M&L for rendering 15mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified. |
| 33 | M&L for 15mm thick Rendering in CM 1:4 on brick work or concrete surfaces with water proofing compound finished even and smooth etc complete all as specified and directed. Note: WPC shall be paid separately. |
| 34 | M&L for 10mm thick rendering in CM 1:3 on brick work or concrete surfaces finished even and smooth w/o using extra cement in Ceiling etc complete all as specified and directed. |
| 35 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of whitewash on ceiling over a coat of birla 1.00mm thick white putty complete all as specified and directed by Engr-in-Charge |
| 36 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distermper over a coat birla 2.00mm thick white putty complete all as specified and directed by Engr-in-Charge |
| 37 | M&L forr Preparation of new plastered or unplastered decorated surfaces of walls or cornics thereafter applying two coat of exterior emuslion paint and including 2mm thick wall care putty to achieve smooth finish over a coat of appropriate primer complete all as specified and directed by Engr-in-charge. Note- Exterior emulsion paint to be done by Roller. |
| 38 | M&L for two coats of cement base paint, white or tinted on walls / vertical surfaces incl. Preparing of new ( plastered or unplastered ) surfaces with chalk whiting priming complete all as specified and directed by Engr-in-Charge. |
| 39 | M&L for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and as directed by Engineer-in-Charge. |
| 40 | M&L for pre painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and as directed by Engineer-in-Charge. |
| 41 | M&L for hardcore of broken stone or boulders of gauge n. exc 63mm, deposited spread and levelled in layers n exc. 15 cm thick watered and rammed to a true surface complete all as specified. |
| 42 | M&L 75mm thick PCC 1:3:6 type C2 as in plinth protection finishing the surface even and smooth with out using extra cement complete all as specified and directed. |
| 43 | Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete |
| 44 | M & L for 40mm thick Damp proof course to horizontal or vertical surfaces including necessary formwork |
| 45 | S&F pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 125 x 60mm filling hollow frame complete all as specified and directed. |
| 46 | M&L PCC 1:3:6 type C2 as in filling of chowkhats complete all as specified and directed by Engineer-in-charge. |
| 47 | S&F factory made 2nd class, hard wood, 35mm thick glazed and skeleton shutters, open rebated and prepared to received glass, gauge, etc ( without sash bars) edges of framing plain, chambered or rounded, fitted with cut and mitred beads for securing glass , etc but difided into squares with plain chamfered or rounded mirted and rebated sash bars any numbers sizes of members of shutters as specified and directed by Engineer-in -Charge. |
| 48 | S &F factory made 2nd class hard wood Plain, framed, panelled shutters 35 mm thick (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed by Engineer-in-charge. |
| 49 | S&F Aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt in 200mm |
| 50 | S&F extruded aluminium alloys handles frabicated type anodized of size 150mm long. |
| 51 | S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt in 250mm complete all as specified and directed. |
| 52 | M&L for preparation of new wooden surface exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 53 | M&L for preparation of new steel surfaces of any description over 10cm girth or width not otherwise described and applying two coat of synthetic enamel paint over red oxide primer all as specified and directed by Engineer-in-Charge. |
| 54 | Providing and fixing factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose. |
| 55 | Supply and fix steel ventilators fixed type with glazing bars etc complete all as specified and directed by EIC. |
| 56 | S&F 4.00mm thick sheet glass, ordinary quality in squares n exc 0.5 sqm each pane and glazing with oil putty complete all as specified and directed by Engineer-in-charge. |
| 57 | S&F 4.00mm thick figured glass, pinhead type in squares n exc 0.5 sqm each pane and glazing with oil putty all as specified. |
| 58 | S/F stainless steel wire cloth 0.56mm nominal dia of wire and avarage width of aperture 1.00mm and fixed with tinned tacks/screws with bolts incl leaping wooden complete all as specified and directed. |
| 59 | S/F 300mm MS ordinary rat rail rod pattern helical springs including roller and roller plate complete all as speicified complete all as specified and directed. |
| 60 | Preparation of newly plastered surface making surface completely dry after drying of primer apply APP modified water proofing membrane with non woven polyster reinforcement 3mm thick superior multipolymericweighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers with a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm under the APP membrane laid with torching application to the surface complete and sealing the side as well as end laps (overlaps should not be less than 10 cm) complete all as specified and directed. |
| 61 | M&L cement concrete Type B0 1:2:4 (12.5mm graded aggregate) in roof kerbs, rounded or chamfered edges complete all as specified and directed by Engineer-in-charge. |
| 62 | M&L for rendering 10mm thick cement mortar 1:3 on concrete surface even and smooth with waterproofing compound as directed by Engr-in-Charge |
| 63 | Supply only integral water proofing compound. |
| 64 | Supply and apply high build elastomeric waterproofing coated based on pure hydrophobic polyurethane cold applied or spray, brush applied, membrane with an elongation of 280 % and tensile strength of 2.7N/mm2 as per ASTMD 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure, minimum 88% solid content. The system includes final base preparation, epoxy primer application with 100% water dilution and pure polyurethane application in two coats with minimum consumption of 1.2 kg/sqm complete all as specified and directed by Eng-In-Charge. |
| 65 | S/F solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening |
| 66 | S&F Factory made solid PVC panel shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and a gap insert for top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement as specified in SSR Part-II- 2004 SEC 8 CLAUSE 8b1 TO 8b 2.1complete all as specified and directed by EIC |
| 67 | S&F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 68 | S&F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified |
| 69 | S&F alumunium hinges for PVC door shutter, size of hinges in 100mm |
| 70 | Cutting chases, pinning in, making good to facing through brick wall where reqd and pointing in CM 1:3 to ends of edges of landing etc and cutting chases for concealed water tubing and making good cutting exc 10 cm but n.exc 20 cm girth. |
| 71 | S&F GI tubing 20mm dia medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors including making hole in RCC slabs for vertical pipes & making good the same with Cement Concrete I:2:4. |
| 72 | S&F GI tubing 15mm dia medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors. |
| 73 | S&F vitreous china wash down water closet pan (Pedestal pattern) of white colour including plastic water closet seat back closed pattern with flat bottom (with MS or CP hinging device) and fixing bolts, P or S trap, jet spray necessary inlet and outlet connections including syphonic action type low level PVC flushing cistern of 10 lit capacity make white in colour and PVC flush pipe 32mm dia complete. |
| 74 | Supply and fix vitreous china ware wash basin white, flat back size 550 X 400mm with pedestal including 15mm dia pillar tap chromium plated, CP waste coupling, waste fittings, union and waste pipe 32mm dia or required length and all necessary inlet, out let connections complete |
| 75 | Supply and fix vitreous china bowl urinals flat back, half stall complete including providing & fixing plugs, bedding urinal against wall in CM (1:2) securing urinal to plugs with & including 60cm long brass screws, jointing around urinal back in cement paste including flush pipe, grating and union for discharge pipe as specified. |
| 76 | S&F 15 mm bore CP bib taps fancy type cast copper alloy with crutch or butter fly handle screwed down for iron pipe or for brass ferrule and fixed complete. |
| 77 | S&F concealed 15mm dia of pipe stop valves, chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for Unions and fixed . |
| 78 | Supply & fix 15mm Angle valve fancy type of CP cast copper alloy , with capstan heads, chromium plated, screwed down high pressure, screwed for iron pipe and fixed |
| 79 | S&F PVC connection 15mm dia and 45cm long with two Nos of brass checknuts and washers complete. |
| 80 | S&F brass Choromium plated shower rose with or without swivel joints 125mm size includingfixing to steel pipe or union complete. |
| 81 | Supply of 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 82 | S & F PTMT Corner shelf with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 300 gms) |
| 83 | Supply and fixing of soap-dish chromium plated all as specified |
| 84 | S&F 600mm long tubular tower rail brass chromium plated 20mm dia, D type 60cm longfixedwith two plugs (Gutties) of 2nd class hard woodembeded in cement mortor 1:3 with MS screwscomplete all as specified. |
| 85 | S&F 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as directed by Engineer-in-Charge. |
| 86 | S&F 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as directed by Engineer-in-Charge. |
| 87 | S&F 75 mm PVC (SWR) bend complete all as directed by Engineer-in-Charge. |
| 88 | S&F 110 mm PVC (SWR) bend complete all as directed by Engineer-in-Charge. |
| 89 | S&F PVC(SWR) floor trap with CP grating and diameter of outlet 75mm including jointing to waste pipe fixed with solvent cement complete all as specified and directed. |
| 90 | S&F rotational moulded polythelene water storage tanks cylindircal water tank for hoisted and fixed in postion of 1000 ltrs capcity incl fittings and as directed by Engr-in-Charge |
| 91 | Supply and fixing 20 mm dia gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed. |
| 92 | Supply & fix 20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. |
| 93 | 110 mm bore PVC (SWR) vent cowl. |
| 94 | S & F PVC (SWR) gully trap 125/110 mm setting and jointing with solvent , cement |
| 95 | Supply and fixing 100 mm bore stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for nominal bore. |
| 96 | Returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick using excavated soil. |
| 97 | Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed. |
| 98 | Cement concrete (1:3:6) type C2 using 40mm graded crushed stone aggregate as in bed of RCC NP-2 pipe 300mm bore including packing under and haunching against the sides of pipes after laying and testing complete all as specified |
| 99 | M & L Reinforced concrete 300 mm dia pipe class NP-2 laid & jointed complete with collars, complete all as specified and directed. |
| 100 | Cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in surface channel and benching for manholes and haunching around manholes frames including necessary form work and finishing exposed surfaces even and smooth without using extra cement. |
| 101 | Soakage well excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.0 m dia X 4.50 m effective depth (DRG No CEJZ/STD-242/07) |
| 102 | M&L for 20 users on site LLDPE conventional Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc. complete |
| 103 | M&L for Sand filing under floors or in foundations including watering and consolidation |
| 104 | M & L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658 - 2006 of 80mm thick ness, M-40 grade with grey cemet and pigment over sand cushioning complete all as specified. |
| 105 | M&L Precast cement concrete block masonary with solid block (size 30x20x10 cm) as in edging ,type B1 1:2:4 (20 mm graded aggregate) exc 10 cm in width and setting in mortar 1:4 complete |
| 106 | M & L for point wiring with 1.5 Sgmm (Nominal Area) FRLS PVC insulated sheathed multi stranded copper conductor, 1100 Volts drawn through and including rigid non metalic concealed conduit medium grade ISI marked minimum 20mm size and its accessories complete along with 1.5 sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed, in walls/ ceiling/ roofs with and incuding 1.2mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting modular switches, Socket, bell push, fan requiators etC. as required with modular frame and cover of 1 module to 18 module as required at site all as specified and as directed for the following points :- |
| 107 | One light point controlled by one 1-way switch. |
| 108 | One ceiling / exhaust fan point controlled by one switch. |
| 109 | One three pin socket out let 5 amps on independent board complete. |
| 110 | One three pin socket out let 5 amps on Same board complete. |
| 111 | All as per item no 105 above but with 2.5 Sqmm (Nominal Area) FRLS PVC insulated sheathed multi stranded copper conductor, 1100 Volts for one 3 pin socket out let 15 amps on independent board. |
| 112 | S&F switch modular type 6A 240 Volts complete all as directed |
| 113 | S&F switch modular type 15A 240 Volts complete all as directed |
| 114 | M & L ceiling rose surface type Bakelite 65 x 50 mm with three terminals complete all as directed |
| 115 | S&F modular socket outlet 2 in 1, 3 pin, 5/6 amp with shutters complete. |
| 116 | S&F modular socket outlet 2 in 1, 3 pin, 5 and 15 amp with shutters complete. |
| 117 | Taking down old unserviceable Lamp holder & S&F Lamp holder, PVC/Polycarbonate angular type with LED lamp base B-22 (holder type) 7 watts complete all as directed |
| 118 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CMM with service value 6.00 BEE with brushless direct current motor (BLDC) with copper wound complete all as specified and directed. Note: (1) Rate for taking down C.fan & trasportaion to deposit at E/M storeyard to ceiling fan deemed to be incuded in this rate. Make : Orient electric automiser, Crompton Energion HS 1200, Havells efficiencia. |
| 119 | Supply and fix metallic Heavy duty Exhaust fan copper wound with double ball bearing continuous duty with louvers, with fixing arrangements & making hole of suitable size if necessory for 300 mm sweep, 900 rpm, 230V. |
| 120 | S&F LED light fitting 1x20 watt, 220 volt AC decorative box type with driver, holders,including LED tube light connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and directed. |
| 121 | S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 220 volt AC decorative type with driver, holders,including LED lamp connecting up with three core flexible copper conductor of suitable size complete all as specified and directed. Make -Philips/Crompton/Havells |
| 122 | S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with GI bracket of dia 40mm light grade of suitable size with complete. Make :Crompton/CG/Philips/Luker. |
| 123 | |S&F LED decorative wall Lights 16/20 W 230 V complete all as directed at site. Make: Philips : Grace Wall light/Havells/Crompton |
| 124 | M & L for sub main wiring with FRLS PVC insulated. 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications with 3 runs of 6 sqmm single core multistranded copper conductor FRLS PVC insulated cable as earth continuity conductor drawn through & including PVC conduit of 20mm dia. size and conduit accessories concealed in wall connecting to common earth dolly all as specified and directed. Note: (i) Three runs of cable and one run of conduit with necessary accessories will be measured as one unit length. (ii) The wiring shall be done in proper colour coding using red, yellow or blue for phase, black for neutral and green for earth leads. |
| 125 | Supply and fix Sheet steel factory made, powder coated MCB DB with bus bar 200Amps. Neutral link, Earth bar, double door TPN 4 way 230 volts all as directed. Make - Indoasian/Legrand/Havells |
| 126 | Supply and fix Sheet steel factory made, powder coated MCB DB with bus bar 200Amps. Neutral link, Earth bar, double door SPN 8 way 230 volts all as directed. Make - Indoasian/Legrand/Havells |
| 127 | S & F Single pole and neutral enclosure with a two pin and earth with single pole MCB 20 Amp. Make :Havells/L&T/Legrand. |
| 128 | S&F MCB Single pole 240 volts 6-32 Amps, 10KA, B-series, Make - Havells/L&T, Legrand |
| 129 | S&F MCB SPN 240 volts 0- 32 Amps, 10KA, B-series. Make - Havells/L&T, Legrand |
| 130 | S&F MCB TPN 415 volts 25 - 100 Amps, 16KA, B-series. Make - Havells/L&T, Legrand |
| 131 | M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mm x 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 4 mm dia GI earth lead wire as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead protected in and including 15 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as directed. |
| 132 | S&F electric water heater, storage type ABS body with metalic inner tank and heating element capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, Automatic Thermal cut-out and multi function valves, NRV, 450 mm brass connection pipe etc. Make- Havells monza DX/Usha Aquerra/ Racold Classico |
| 133 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out including trimming of sides complete all as specified and directed by Engineer-in-Charge. |
| 134 | Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer compete all as specified and directed by Engineer-in-Charge. |
| 135 | Removal of surplus spoil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge. |
| 136 | Supply and fixing GI tubing medium grade 25 mm bore in any length with all fitting laid in trench and connecting up with water supply main complete all as specified and directed (Excavation and earthwork shall be measured and paid for separetely under approprite item) |
| 137 | Supply and fixing GI tubing medium grade 40 mm bore in any length with all fitting laid in trench and connecting up with water supply main complete all as specified and directed (Excavation and earthwork shall be measured and paid for separetely under approprite item) |
| 138 | Supply and fix in replacment of gun metal globe or gate valve with iron wheel head screwed both ends suitable for galvanised pipe 40 mm bore complete all as specified. |
| 139 | Supply and fixing GI tubing medium grade 25 mm bore in any length with all fitting laid in trench and connecting up with water supply main complete all as specified and directed (Excavation and earthwork shall be measured and paid for separetely under approprite item) |
| 140 | Supply and fix in replacment of gun metal globe or gate valve with iron wheel head screwed both ends suitable for galvanised pipe 15 mm bore complete all as specified. |
| 141 | Supply and fix in replacment of gun metal globe or gate valve with iron wheel head screwed both ends suitable for galvanised pipe 15 mm bore complete all as specified. |
| 142 | M&L for Cutting cast iron/GI pipe up 40/50 mm bore, in position for insertion of new tees of suitable size including jointing materials complete all as specified and directed |
| 143 | Supplying, laying, jointing and testing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 vols grade cross sectional area 16 Sqmm 4 core laid in trences, in floor, in duct, through pipes or along the pole including taking down old one complete all as specified and directed by Engr-in-Charge. |
| 144 | Material and labour for sand cushioning to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable complete all as specified and directed. |
| 145 | Material and labour for brick protection using old size sub class ‘B’ bricks, laid flat, dry adjacent to each other laid length wise perpendicular to the axis of cable complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail