| 1 | M&L for brickwork with fly ash bricks (old size), straight or curved on plan, exc 6 m mean redius, built in cement mortar 1:6 with and including demolition of existing brick work built in cement or cement lime mortar of any description complete all as specified and as directed |
| 2 | M&L for walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 including demolition of existing stone masonry work complete all as specified and as directed. |
| 3 | All as per serial item No. 2.00 above but except stones Note : Old stones obtained from demolition shall be reused. |
| 4 | M&L for precast cement concrete block masonry with solid block of PCC (1:5:8), exc 10 cm in width and setting in cement mortar (1:6) including demolition of existing block work built in cement or cement lime mortar of any description complete all as specified and as directed. |
| 5 | Taking down cement plaster on walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed. |
| 6 | M&L for rendering 15 mm thick on fair faces of brick work /concrete surfaces in cement mortar 1:4, finished even and fair without using extra cement complete all as specified and as directed. |
| 7 | M&L for rendering 15 mm thick on other than fair faces of brick work /concrete surfaces in cement mortar 1:4, finished even and fair without using extra cement complete all as specified and as directed. |
| 8 | M & L preparation of new plastered surfaces/ concrete surfaces of walls and applying two coat of cement base paint over a coat of alakli resistant primer complete all as specified and as directed. |
| 9 | M&L for preparation of Old plastered surfaces and applying one coats of cement base paint over prepared old plastered or unplastered wall surfaces, complete all as specified and as directed by Engineer-in-Charge. |
| 10 | M&L for preparation of new wall surfaces and applying two coat of 100% premium exterior acrylic emulsion paint, alkali & fungal resistance, dirt resistance on over a coat of exterior alkali resistant primer complete all as specified and as directed by Engineer-in-Charge.. |
| 11 | Dismantling fencing posts or struts (wood, steel or R.C.C.) any section, embedded in concrete etc.complete all as specified and directed. |
| 12 | Excavation in post holes in any type of soil, each not exceeding 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed. |
| 13 | M&L for PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in bands, beam, benching to drain, coping slightly rounded or chamfered angles and throating and similar work including necessary formwork complete all as specified and as directed. |
| 14 | M&L for PCC 1:3:6, type C2, using 40mm graded stone aggregate as in foundations filling and mass concrete for fixing fencing posts and similar work complete all as specified and as directed. |
| 15 | S&F in repairs, galvanised, 2 strand, steel barbed wire, 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails restraining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and as directed. |
| 16 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 17 | M&L for prestressed reinforced cement concrete solid posts with fair faces in precast cement concrete 1:2:4 type B-0 (12.5mm graded stone aggregate) including mouldings and fixed in columns, posts, boundary pillars with and including grooves for locking of precast RCC wall panels, set in cement mortar 1:4 complete all as specified and as directed.Notes : (a) The cost of reinforcement and form work shall deemed to be included in rate quoted.(b) Precast/prestressed slabs for wall shall be measured and paid separately under respective item. |
| 18 | M&L for 45 to 50mm thick precast reinforced cement concrete solid slabs finished fair on both sides in cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) (with interlocking joints for fixing in precast columns) including mouldings and fixed as compound wall in grooves of prestressed posts as per approved design and pattern and set in cement mortar 1:4 complete all as specified and as directed. Notes : (a) The cost of reinforcement and form work shall deemed to be included in rate quoted.(b) Surface area of slabs excluding embedded porton in grooves shall be measured for payment. (c) Prestressed concrete posts shall be measured and paid separately under respective item. |
| 19 | Dismantling old fencing wire mesh/chain link fencing, any description, any type complete all as specified and as directed. |
| 20 | Supply only mild steel galvanised chain link fencing, made out of GI wire, any size or type, complete all as specified and directed.Note :- Dia and size of mesh shall be as decided by GE. (ii) Payment shall be allowed after ascertaining weight of chain link fencing as per actual at site by the BOO ordered by GE. |
| 21 | Fixing only chain link fencing wire mesh, any size and type to any standards, angle iron posts, rails, straining bolts including provision of binding wire etc. and fixed complete all as specified and as directed. |
| 22 | M&L for machine made, mild steel bolts, 10 mm dia shank with hexagonal or square head one end and screwed the other or screwed both end, each screwed end to be fitted with, washers and one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm complete all as specified and as directed. |
| 23 | S&F mild steel angle/flat iron as in fencing posts/struts for securing barbed/chain link fencing of any description including drilling holes, notching for wire etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or rivetting and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 24 | S&F mild steel round or square bars as in line bars for fixing chain link fencing including cutting to length, bent to shape required, hooking ends complete all as specified and as directed. |
| 25 | Dismantling mild steel work including doors, gates but excluding framed trusses complete all as specified and as directed. |
| 26 | S&F framed work as in doors or gates of angle/hollow section or other sections with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges and door fittings necessary rivetting/welding cutting up complete steel conforming to Fe-410-0 or Fe-310-0 all as specified and as directed. Note : Disturbed surfaces of walls shall be made good to match with the existing surfaces. |
| 27 | Labour only for erection and fixing of mild work as in doors or gates of angle/hollow section or other sections with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges and door fittings necessary rivetting/welding cutting up complete of any grade of steel all as specified and as directed. Note : Disturbed surfaces of walls shall be made good to match with the existing surfaces. |
| 28 | Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 29 | M&L for 75mm thick plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base of floors and pavings complete all as specified and as directed. |
| 30 | Dismantling of stone slab and tiles laid bedded and pointed in any mortar description or thickness in floors, apron etc complete all as specified and as directed. |
| 31 | M&L for 60mm thick factory made chamfered edge, cement concrete paver blocks (glossy/ rubber matt finish) of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed |
| 32 | M&L for 80mm thick factory made chamfered edge, cement concrete paver blocks (glossy/ rubber matt finish) of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. |
| 33 | Fixing only cement concrete paver blocks as in footpath, parks, lawns, drive ways or light traffic parking etc., over and including 25mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed.Note: Old cement concrete paver blocks of any type and size retrieved from dismantling shall be reused under this item. |
| 34 | M&L for 18-20 mm thick prepolished granite stone slab of approved shade as in table top, top of WHB, kitchen slab/platform, steps, gate pillars, cills etc or on vertical surfaces including vertical projection, including full round moulding the edges, laid over and including 15mm thick screed bed in cement mortar 1:4, jointing , pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite and rubbing polish to achieve mirror finish complete all as specified and as directed.Note : Colour and shade of granite shall be as approved by GE. |
| 35 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing complete all as specified and as directed. |
| 36 | M&L for factory made digitally printed coloured vitrified parking/paver tiles, 9 to 10 mm thick (square or rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (400X400 mm) as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20mm thick screed bed in CM 1:6 etc complete all as specified & directed.Note : Colour and design shall be as approved by Engineer-in-charge. |
| 37 | M&L for factory made digitally printed heavy duty coloured vitrified parking/ paver tiles 11 to 12 mm thick (square or rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm (600X600 mm) in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed in CM 1:6 complete all as specified & directed.Note: Color and shade shall be as approved by Engineer-in-charge. |
| 38 | M&L for precast cement concrete coloured chequered tiles with glossy finish of size 25cm x 25cm x 25mm thick/30cm x 30cm x 25mm thick, machine pressed with grey cement and pigment, set, jointed and pointed in neat cement slurry over and including 20mm thick screed bed or bedding layer in cement mortar 1:6 and pointed in coloured cement to match the colour of tiles complete all as specified and as directed. |
| 39 | M&L for moorum filling in floors or paving, laid in layers n.exc. 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed. |
| 40 | M&L for hard core of gauge not exc. 63 mm, deposited spread and levelled in layers n. exc. 15cm thick, including watering and rammed etc. complete all as specified and as directed. |
| 41 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over one coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 42 | M&L for preparation of old steel or iron surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paints complete all as specified and as directed. |
| 43 | M&L for preparation of new steel and iron surfaces of any description not otherwise described not exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 44 | Earth work in excavation by mechanical means (Hydraulic excavator) in all kind of soil over areas (exceeding 30 cm in depth,1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, all as specified and as directed. |
| 45 | Excavation in trenches not exc 1.50m wide and not exc 1.50m deep for foundation etc . or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and as directed. |
| 46 | Returning, filling in soil, including spreading, levelling watering & well ramming in layers not exc 25 cm thick complete all as specified and as directed. |
| 47 | Removing excavated soil to distance exc 250 m (beyond 50m catered under item 44 above) but n exc 500 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 48 | S&F in repairs 110mm dia PVC (SWR) pipes, single socketed, in any length, with rubber ring joint, laid in trenches or in floors or in masonry as in spouts, weep holes etc complete all as specified and as directed. |
| 49 | M&L for 35mm thick precast cement concrete louvers and jallies including mouldings in precast cement concrete 1:2:4 type B-0 using 12.50mm graded stone aggregate and fixed in cement mortar 1:4 including dismantling old precast louvers and jallies complete all as specified and as directed. |
| 50 | M&L for welding in repairs n exc 2.5cm in length and thickness of metal to be welded not exc 6 mm all as specified and as directed. |
| 51 | M&L at or near ground level factory made kerb stone of M-25 grade cement concrete fixed in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required and dismantling of existing kerb stones complete all as specified and as directed. |
| 52 | M&L for preparation of concrete/plastered surface over 10 cm width or girth applying two coats of synthetic enamel paint over one coat of primer paint of any description complete all as specified and directed. |
| 53 | M&L for preparation of concrete/plastered surfaces over 10 cm width or girth applying one coat of synthetic enamel paint, any description complete all as specified and as directed. |
| 54 | M&L for RCC 1:2:4 (nominal mix) type B-1 using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span,etc complete all as specified and as directed. |
| 55 | Use and waste of formwork to sides and soffits of beams for rough finished surfaces of concrete all as specified and as directed. |
| 56 | M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 57 | M&L for mild steel TMT bars 5 mm dia and over upto and including 10mm dia, in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 58 | S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including dismantling of old mild steel work all as specified and as directed. Please Enable Macros to View BoQ information |