| 1 | Supply and fixing of Mast Nut, Bolt & templates suitable for 30 Mtr High mast. Complete in all respects as per directiion of E/I.(AOR) |
| 2 | Supply and fixing of Winch Machine assembly suitable for 30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 3 | Supply and fixing of SS Rope Wire 16Mtr/30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 4 | Supply and fixing of Lantern Carriage made of 2.5\\" outer dia G.I. Pipe Class B heavy duty for mounting the luminaries suitable for 16Mtr/30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 5 | Supply and fixing of Head Frame with Pulley suitable for 16Mtr/30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 6 | Dismantling of 30 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. Complete in all respect . As per direction of E/I. (AOR) |
| 7 | Fixing of 30 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. on existing foundation. Complete in all respect . As per direction of E/I. (AOR) |
| 8 | Dismantling of 16 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. Complete in all respect . As per direction of E/I. (AOR) |
| 9 | Fixing of 16 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. on existing foundation. Complete in all respect . As per direction of E/I. (AOR) |
| 10 | Supply and fixing of Window Door/Cover size as per 16Mtr/30 Mtr High mast made of 3mm thick MS Sheet with 2 Nos heavy duty lock shutter type incl. hinged. Complete in all respects as per directiion of E/I. (AOR) |
| 11 | Supply and fixing of Aviiation Light suitable for 16Mtr/30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 12 | Supply and fixing of MS Lighting arrestor rod suitable for 16Mtr/30 Mtr High Mast. Complete in all respects as per directiion of E/I. (AOR) |
| 13 | Supply and fixing of fibre Junction Box suitable for 16Mtr/30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 14 | Supply and fixing of Mast Nut, Bolt & templates suitable for 16 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 15 | Supply and fixing of Winch Machine suitable for 16 Mtr High mast. Complete in all respects as per directiion of E/I.(AOR) |
| 16 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. DSR Electricals 2018 No. 9.3a) 2 X 16 sq. mm (9.3.1) |
| 17 | b) 2 X 25 sq. mm (9.3.2) |
| 18 | c) 4 X 16 sq. mm (9.3.29) |
| 19 | d) 3.5 x 50 sq. mm (9.3.19) |
| 20 | e) 3.5 X 70 sq. mm (9.3.20) |
| 21 | fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect .CAT- AAA PS No 1455 |
| 22 | S/F of 11 KV TPMO Reico/Rama make 9 nos insulator of Jai shree/BHEL make complete in all respects as per direction of E/I UPERC-48 |
| 23 | S/F of 11 kV, 100 Amp, Drop fuse set channel type (3 nos) (AOR) |
| 24 | S/L of Al conductor PVC/XLPE insulated rmoured served sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand alround & protected with burnt on sides & on top surface the cable run shall be fixed on M.S. Clamps etc of suitable size or as directed by complete in all respects. The armoruring of the cable shall be properly connected with the earth conductor by clamps etc. P S No 501. 50 Sqmm x 3.5 Core |
| 25 | 16 sqmm x 4 core |
| 26 | S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as pe direction of E/I PS No. 504. i) 16 Sqmm |
| 27 | ii) 50 Sqmm |
| 28 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. DSR 14.16.1a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 29 | b) 90 mm dia (OD-90 mm & ID-76 mm nominal) (14.16.2) |
| 30 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50mm, inner Dia 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity one earth lead of 25mm x 3mm G.I. Strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra.) along with 30 cm squrare C.I. frame with hinged cover masonry housing . ps 725 (B) 2018 |
| 31 | S/L of 25x3mm G.I. Strip from earth electrode directly in the ground as required Complete in all respects as per PS No. 716 |
| 32 | Supplying and fixing of light class G.I. pipe of 80 mm dia.(nominal) 3 metres length along the pole for protection of under ground cable as required. DSR Electrical-18/ 12.38 |
| 33 | Supply and fixing of TPN capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint crossing of time switch TSO 100 series with contractors, HRC fuse, isolating swtich metering instrument & instrument box with CTs etc. in case of TPN, Complete in all respects. as per PS No. 807F-ii. 40 Amp |
| 34 | Supply and laying of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc.PS 506 a) 120 sq. mm 3 core |
| 35 | S/F of jointing of following sizes outdoor/indoor type 11 KV jointing kit heat Shrinkable type for 11 KV Cable including cost of all material, labour, T&P etc. for proper completion of the E/I. (Raychem/Denson Make) uperc Pg-41 120 Sqmm |
| 36 | S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE 100 (PE 400) grade as per IS code 4984 with excavation at a depth of 1.20 Mtr below ground level i/c the cost of cutting of pipes for making up to length and making joints complete all respects as per direction of E/I.. (AOR) |
| 37 | Location and pin pointing of LT Cable fault exposing the same in the underground LT Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by providing fault locator machines with operator (Cable fault locator) (AOR) |
| 38 | Location and pin pointing of 11KV HT Cable fault exposing the same in the underground 11KV Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by providing fault locator machines with operator (Cable fault locator) (AOR) |
| 39 | Location and pin pointing of LT Cable fault exposing the same in the underground LT Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by expert technical staff. (AOR) |
| 40 | Pole Bus bar support connector 4 way with Backsheet. Completed in all respects. (AOR) |
| 41 | Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects P.S. No. 627 |
| 42 | S/f of 11 KV Disc insulator 70 KN and fitting B&S heavy duty with clamp of cross arm fixed on ht pole BHEL/ Jai shree / WS/RR make UPERC 19 P No 24 I No 9 |
| 43 | S/f of 11 KV Pin 12 long with insulator of Jai shree/BHEL on cross arm fixed on HT pole including all T/P etc UPERC P No 26 I No 7 |
| 44 | Supply and laying 90 mm dia DWC ( Double wall corrugated pipe across the road by Trenchless method (Manual). Complete in all respect as per direction of E/I. (AOR) |
| 45 | Supply and fixing of XLPE insulated Al. unarmoured cable for working voltage for energizing the distribution boxes & street light size 1x25sqmm complete in all respects as per direction of E/I. (AOR) |
| 46 | S&F of 6 Amp to 32 Amp. SP MCB (10 KA) C Curve Ps No.1002 CAT A |
| 47 | S&F of 63 Amp. 4 pole MCB(10 KA) C Curve CAT A PS No.1020A CAT A |
| 48 | Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 3 output (1output per phase) and suitable for three phase supply DSR Electrical 2018/15.4.3 |
| 49 | Cement Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.07/S.N. 279 |
| 50 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Cold twisted bars (AOR) |
| 51 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. The contractor has to detect different utilities like sewer line, water supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavation only after getting permission of E/I. All kinds of soil.(AOR) |
| 52 | Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns (AOR) |
| 53 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (AOR) |
| 54 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) DSR Civil-2018/I-5.2.2 Please Enable Macros to View BoQ information |