| 1 | New Pumping Station at basti Baba Kutiya Manjhari Ayodhya |
| 2 | Construction intake Chanel in RCC 4*3.3 mtr |
| 3 | Construction of rectangular sump well in RCC with 1.50% Reinforcement of following depth up to platform level pump house in B/W 1:4 in Super Structure above platform level with roof height of SMTR with RCC roof. |
| 4 | Supply, Installation Testing & Commissioning of diesel driven /Eelectric sewage VT Pumping plant including column assembly Suction Saner Tee Reducer, coupling with all connected Equipment etc all Complete (Kirloskar, Flowmore or Equivalent make and should be relevant to IS/BS standard 10000 LPM 3pase, VT Set 12 M Head suitable HP with required civil work and compelete in all repesct. |
| 5 | Supply, Installation Testing & Commissioning of Starter suitable for Above pump with required civil work and compelete in all repesct. |
| 6 | Supply, Installation Testing & Commissioning of NR Valve 300 valve special design for sewage purpose. |
| 7 | Supply, Installation Testing & Commissioning of NR Valve 600 valve special design for sewage Purpose. |
| 8 | Supply, Installation Testing & Commissioning Traveling crane supply of 10 Ton Capacity 6 Mtr. Mt 12 Mtr. Span traveling crane standard make capacity block extra with required material (Indent/Mints or Equivalent make and should be relevant to IS/BS standard) complete in all respect with required civil work and compelete in all repesct. |
| 9 | Supply, Installation Testing & Commissioning. 300 mm dia MS rising mains of 6 mm wall thickness including coupling and laying for discharge of the storm of the pumping plant including excavation laying of the pipe etc. 1.0 to 1.50 Mtr. deep into the underground trench excavated in the existing road etc all comp. as per direction of E/inch. as per the unit rate analysis. |
| 10 | Supply, Installation Testing & Commissioning. 600 mm dia MS rising mains of 6 mm wall thickness including coupling and laying for discharge of the storm of the pumping plant including excavation laying of the pipe etc. 1.0 to 1.50 Mtr. Deep into the underground trench excavated in the existing road etc all comp.with required civil work and compelete in all repesct. |
| 11 | Supply, Installation Testing & Commissioning of Genset 400 KVA with required civil work and compelete in all repesct. |
| 12 | Supply, Installation Testing & Commissioning of genset 630 KVA CSS tarsnformer complete in all respect. |
| 13 | Supply, Installation Testing & Commissioning of of pannel with VCB and LT with required civil work and compelete in all repesct. |
| 14 | Supply, Installation Testing & Commissioning of MS work spefially as per site requirment. |
| 15 | Making and restoration of road for above pipe line work via damar and interlocking with required civil work and complete in all respect. |
| 16 | Under Ground Cables 240 Sq.mm |
| 17 | Under Ground Cables 120 Sq.mm |
| 18 | Under Ground Cables 120 Sq.mm (HT) |
| 19 | Supply and burring of safe Earthing electrode pf T-39 Cu Copper coated, Length up to 3000mm, outer pipe 76.03 x 3.2 inner pipe 42.4 mm x 2.6 mm, terminal dia 12mm, coating 80-100 micro filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs active soil (BFC) capable of reducing the soil restively with good mixture of retaining capacity along with 30 CM square CI Frame with hinged cover & masonry housing. (from electrode terminal to switch board cost of 25x3 copper strip will be extra. |
| 20 | New Pumping Station at Brahma Kund Awas Vikas Colony, Ayodhya |
| 21 | Construction intake Chanel in RCC 4*3.3 mtr |
| 22 | Construction of rectangular sump well in RCC with 1.50% Reinforcement of following depth up to platform level pump house in B/W 1:4 in Super Structure above platform level with roof height of SMTR with RCC roof. |
| 23 | Supply, Installation Testing & Commissioning of diesel driven /Eelectric sewage VT Pumping plant including column assembly Suction Saner Tee Reducer, coupling with all connected Equipment etc all Complete (Kirloskar, Flowmore or Equivalent make and should be relevant to IS/BS standard 10000 LPM 3pase, VT Set 12 M Head suitable HP with required civil work and compelete in all repesct. |
| 24 | Supply, Installation Testing & Commissioning of Starter suitable for Above pump with required civil work and compelete in all repesct. |
| 25 | Supply, Installation Testing & Commissioning of NR Valve 300 valve special design for sewage purpose. |
| 26 | Supply, Installation Testing & Commissioning of NR Valve 600 valve special design for sewage Purpose. |
| 27 | Supply, Installation Testing & Commissioning Traveling crane supply of 10 Ton Capacity 6 Mtr. Mt 12 Mtr. Span traveling crane standard make capacity block extra with required material (Indent/Mints or Equivalent make and should be relevant to IS/BS standard) complete in all respect with required civil work and compelete in all repesct. |
| 28 | Supply, Installation Testing & Commissioning. 300 mm dia MS rising mains of 6 mm wall thickness including coupling and laying for discharge of the storm of the pumping plant including excavation laying of the pipe etc. 1.0 to 1.50 Mtr. deep into the underground trench excavated in the existing road etc all comp. as per direction of E/inch. as per the unit rate analysis. |
| 29 | Supply, Installation Testing & Commissioning. 600 mm dia MS rising mains of 6 mm wall thickness including coupling and laying for discharge of the storm of the pumping plant including excavation laying of the pipe etc. 1.0 to 1.50 Mtr. Deep into the underground trench excavated in the existing road etc all comp.with required civil work and compelete in all repesct. |
| 30 | Supply, Installation Testing & Commissioning of Genset 400 KVA with required civil work and compelete in all repesct. |
| 31 | Supply, Installation Testing & Commissioning of genset 630 KVA CSS tarsnformer complete in all respect. |
| 32 | Supply, Installation Testing & Commissioning of of pannel with VCB and LT with required civil work and compelete in all repesct. |
| 33 | Supply, Installation Testing & Commissioning of MS work spefially as per site requirment. |
| 34 | Making and restoration of road for above pipe line work via damar and interlocking with required civil work and complete in all respect. |
| 35 | Under Ground Cables 240 Sq.mm |
| 36 | Under Ground Cables 120 Sq.mm |
| 37 | Under Ground Cables 120 Sq.mm (HT) |
| 38 | Supply and burring of safe Earthing electrode pf T-39 Cu Copper coated, Length up to 3000mm, outer pipe 76.03 x 3.2 inner pipe 42.4 mm x 2.6 mm, terminal dia 12mm, coating 80-100 micro filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs active soil (BFC) capable of reducing the soil restively with good mixture of retaining capacity along with 30 CM square CI Frame with hinged cover & masonry housing. (from electrode terminal to switch board cost of 25x3 copper strip will be extra. |
| 39 | Operation and Maintenance cost of Above works for 2 years as follows- (Note- the work shall be awarded on the basis of the rates quoted from serial no 1 to 2 The work mentioned in serial number 3 will be awarded later (if required) and separate contract bond will be prepared for O&M work, after the completion of work mentioned at serial number 1 at the rate quoted by the bidder along with this bid. Quoting rate does not guarantee that O&M work will be awarded to the bidder, but bidder cannot deny to do O&M work if offered.) Please Enable Macros to View BoQ information |