| Sl. No. | Item Description |
| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: |
| 2 | All kind of soil |
| 3 | Ordinary rock |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 5 | Extra for every additional lift of 1.5 m or part thereof in excavation/bankingexcavated or stacked material :All kinds of soil |
| 6 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 7 | Anti-Termite |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 9 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with.1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 10 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Providing and laying upto floor v level reinforced cement concrete in kerbs, steps and the like including curing but excluding the cost of centering, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing' |
| 13 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:1½:3 (1 cement: 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 14 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering. finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 15 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with1:1½:3 (1 cement: 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 16 | Supplying and filling with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 17 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 18 | Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete.Dumb bell with central bulb (180mm wide, 8mm thick) |
| 19 | Centring and Shuttering including struting, proping etc and removal of form for. |
| 20 | Foundations, footings, bases of columns, etc. for mass concrete |
| 21 | Suspended floors, roofs, landings, balconies and access platform |
| 22 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 23 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 24 | Arches, domes, vaults up to 6 m span |
| 25 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 26 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 27 | In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. |
| 28 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 29 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 30 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 31 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 32 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 33 | Fixing 18/20 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Makrana White Marble of any colour and shade (excluding cost of marble stone). |
| 34 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 35 | Fixing 20 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Makrana White Marble Stone (excluding cost of marble stone). |
| 36 | Providing and fixing Matt finished SS Grade 304 hanging type floor door stopper with necessary screws, etc. complete.-Flush Doors |
| 37 | Providing and fixing Rubber buffer with necessary screws, etc. complete. |
| 38 | Providing and fixing Brass Handles 600 mm long with necessary screws, etc. complete. |
| 39 | Providing and fixing Brass Lock long with necessary screws, etc. complete. |
| 40 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry, including rubbing and mirror polishing complete with :Makrana white (excluding cost of marble). |
| 41 | Fixing machine cut, mirror/ eggshell polished , Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern ,grooveswherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer- in-Charge. (excluding cost of marble stone). |
| 42 | Stone Cladding on Columns-Main |
| 43 | Stone Cladding on Columns-Small Dia |
| 44 | DOME 2 MANDAP |
| 45 | SHIKHAR 1 DOME 1 |
| 46 | SHIKHAR 2 DOME 2 |
| 47 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.-600x300 mm (Minimum) |
| 48 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. completeSize of tile 600x600 mm |
| 49 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. Size of tile 600x600 mm |
| 50 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 25 mm thick |
| 51 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 52 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levelsGranite of any colour or shade (16mm) (Area of slab upto 0.5 sqm) |
| 53 | Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing ofcut edges etc. complete. |
| 54 | Cement concrete pavement with 1:2:4 (1cement: 2 coarse sand: 4 graded crushed stone aggregate 20 mm nominal size) including finishing and\ |
| 55 | Providing and fixing stainless steel ( Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 56 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steelbolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 57 | CEMENT PLASTER (IN FINE SAND) |
| 58 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 59 | 12 mm cement plaster of mix : |
| 60 | 1:4 (1 cement: 4 fine sand) |
| 61 | 15mm Cement plaster in two coats under layer 12mm thick cement plaster 1 : 5 (1 cement : 5 coarse sand) finished with a top layer 6mm thick cement plaster 1 : 6 (1 cement : 6 fine sand) |
| 62 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete |
| 63 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification.Two or more coats on new work |
| 64 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/liter |
| 65 | Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) |
| 66 | Supplying and applying single component, liquid applied, pure polyurethane based, single component, low VOC,anti root, elastomeric, seamless, waterproofcoating, applied in 2 coats over one coat of PU primer at a total consumption of min. 1.8Kg/ Sq.Mt. to achieve a DFT of 1.2 & thereafter providing & laying 120 GSM polyester geotextile layer. The coating shall be taken to a height of 300mm over the parapet wall and terminated as per manufacturer’s recommendations. |
| 67 | Further laying protective concrete screed of average 75 mm using M20 grade concrete with minimum thickness of 40 mm at the rain water outlet and a slope of 1:120, making wattas at the junctions of horizontal and vertical surfaces to a float finish, well compacted, curing for 7 days etc. completeProviding and fixing factory made uPVC white colour sliding glazed window of height as per drawing/ dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. |
| 68 | Series : I 64 Sliding Window Series Design Type : W01Size (Width X Height) : 2500 X 1600 Glass : 6 mm Clear Toughened - 5 Color : WhiteSlider O/F : 41201-15000 / 108 MM+1.5 MM Slider Sash : 41201-03400 / 65 MM+2 MMFlyscreen Sash : 41201-03300Mesh Material : 20818-17909-90Cm X 30Mtr Al Rail : Grooved ShapeAccessories Type : Single Point Handle Type : Sliding Touch Lock Left,Sliding Touch Lock Right Flymesh Handle : Fly Screen Handle Handle Color : White Roller : Single Wheel With Groove |
| 69 | Series : I 60 Casement Door Series Design Type : W02 Size (Width X Height) : 2400 X 2400 Glass : 6 mm Clear Toughened - 1,2,3 Color : White Outer Frame: 41101-11000 / 60 MM+1.5 MM Coupler : 2108-3108.01 MM Casement Sash : 41101-14000 / 102 MM+1.5 MM Accessories Type : Multi Point Handle Type : Double Side Door Handle Handle Color : White Hinge Type : 3D Hinges Hinge Qty/Shutter : 4 |
| 70 | Series : I 64 Sliding Window Series Design Type : W03 Size (Width X Height) : 1000 X 1000 Glass : 6 mm Clear Toughened - 1 Color : White Slider O/F : 41201-15000 / 108 MM+1.5 MM Slider Sash : 41201-03400 / 65 MM+2 MM Flyscreen Sash : 41201-03300 Mesh Material : 20818- 17909-90Cm X 30Mtr Al Rail : Grooved Shape Accessories Type : Single Point Handle Type : Sliding Touch Lock Left,Sliding Touch Lock Right Flymesh Handle : Fly Screen Handle Handle Color : White Roller : Single Wheel With Groove |
| 71 | Providing & fixing T-iron frames for doors, windows & ventilators of mild steel Tee-sections, joints mitred & welded, including fixing of necessary butt hinges & screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of C.C. 1:3:6 (1cement : 3 coarse sand :6 graded stone aggregate 20mm nominal size) . |
| 72 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer:Using M.S. angles 40x40x6mm for diagonal braces |
| 73 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatmentb) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in- charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period oftwo weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineerin- chargWith average thickness of 120mm and minimum thickness at khurra as 65 mm |
| 74 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete |
| 75 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.Single Socketed pipes : 110 mm diametre |
| 76 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Shoe (plain) : 110 mm shoe |
| 77 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 78 | Providing and fixing ball bearing for rolling shutters. |
| 79 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot &double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in charge(Door handle, lock and stopper etc.to be paid separately). |
| 80 | Providing and fixing bright /matt finished Stainless Steel (Grade 316) handles of approved quality & make with necessary screws etc. all complete. 300mm long as per approved Design(make ) for Glass door shutter |
| 81 | Providing and fixing bright /matt finished Stainless Steel Locking arrangement in glass shutters of approved quality & make with necessary screws etc. all complete of approved Design & make ) |
| 82 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)For fixed portion |
| 83 | Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 84 | Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 85 | Filling the gap in between aluminum frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backerrod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5mm width |
| 86 | Providing &fixing stainless steel (SS-304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge |
| 87 | 205x19mm |
| 88 | 355x19mm |
| 89 | Providing and fixing aluminum extruded section body tubular type universal hydraulic door closer,(having brand logo with IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete : |
| 90 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 91 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :300x10 mm |
| 92 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.125 mm |
| 93 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :Single rubber stopper |
| 94 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin- charge. (Cost of aluminum snap beading shall be paid in basic item.)With float glass panes of 5.0 mm thickness (weight not lessthan 12.50 kg / sqm) |
| 95 | Providing and laying in position Micro concrete of minimum Compressive Strength of 65 Mpa & Standards ASTM C1107 Bulk Density 1.2 kg/l (of fresh mortar). It is a high-strength, shrinkage-compensated, cementitious, pourable mortar designed for repairing, anchoring, or resurfacing concrete structures. It is characterized by its high flowability, rapid strength gain (often in 24 hours), and suitability for thin-sections as per repairs, per drawing & as per direction of Engineer-in-charge.All works above plinth level |
| 96 | Providing & Fixing Shear Studs of 12 mm dia as per drawing to insert in the existing RCC Column.Holes are drilled to a specific diameter, usually 2-4mm larger than the stud diameter, and filled with epoxy. The shear connector shall be connected to new steel reinforcement laid alaround old RCC columns. |
| 97 | Surface roughening to an amplitude of 1/4 in. (approx. 6 mm) is a recognized technical standard to remove old concrete from an existing column to create a rough, bonding surface for new concrete. as per direction of Engineer-in-charge. |
| 98 | Providing & applying Nito Bond Fosroc® Nitobond® EP bonding agent Nitobond EP which shall be a solvent free epoxy based two component resin system . The bonding agent shall be applied by brush & should remain in tacky state after application for a minimum period of 5-6 hrs at 20 deg C & 2-3 hrs at 30 deg C. The product shall achieve 50 N/mm2 compressive strength, 20 N/mm2 tensile strength, 35 N/mm2 flexural strength and 10 N/mm2 shear strength as per BS 6319 standards. The adhesive bond to the concrete substrate shall exceed the tensile strength of the host concrete,etc complete. It shall not be used in the influence zone of the Fosroc Galvashield anodes in case of installation in the periphery of patch. No bond coat shall be applied in case of installation in a grid pattern.over existing RCC column surface as per drawing & as per direction of Engineer-in-charge. |
| 99 | \\"Providing and supplying injection adhesive HILTI HIT-HY 200 R / FISCHER/ WURTH or equivalent male Safe Set System for rebar fixing in dry/ damp conditions for dia of 10mm to 25mm. The system should be made of two components consisting of resin and hardener in 5:1 ratio as a soft foil pack of 330/500ml. The foils should be soft foils for less wastage & being environment friendly. The chemical should have certification/ approvals/ test reports from/ for ETA/ TR023, LEED, corrosion resistant behavior (SGK) , fire rated, water tightness. The installation (drilling hole to the required depth by rotary hammer TE-YD hollow drill bit and filling above mentioned mortar with standard dispenser before inserting rebar) and the setting instructions should be strictly followed as per the manufacturers recommendations. Rate shall be inclusive of pull out test as recommanded by the consultant. Note :- Numbers of bar can be changed as per actual.\\"16mm dia & depth of 160mm (10D) |
| 100 | Providing and fixing water closet squatting pan ( Indian type W.C. pan) with 100 mm sand cast Iron P or Strap, 10 litre low level P.V. C. flushing cistern including flush pipe (of approved make) \\"manually contro(led device (handle lever) conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.Orissa pattern white vitreous china W.C. pan of size 580x440 mm with integral type foot rests. |
| 101 | Providing and fixing PVC pipe for drainage.110mm |
| 102 | Providing and fixing PVC pipe for drainage.75mm |
| 103 | Providing and fixing PVC floor trap110mmX75MM |
| 104 | Providing and fixing Stainless steel grating110mm |
| 105 | Providing and fixing white vitreous china pedestal type water closet (European type W.C . .pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures, complete including cutting and making good the walls and floors wherever requied:W.C. pan with lSI marked white solid plastic seat and lid. |
| 106 | Providing and fixing G.l. pipes complete with G.l. fittings and clamps, including cutting and making good the walls etc.: |
| 107 | 15 mm dia. nominal bore,Medium |
| 108 | 20 mm dia. nominal bore,Medium |
| 109 | 32 mm dia. nominal bore,Medium |
| 110 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x41 Ox265mm sizes respectively. |
| 111 | Providing and fixing wash basin with C. I./M.S. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste ofstandard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China wash basin size 400x400 mm with single 15 mm C.P. brass pillar taps. |
| 112 | Providing and fixing C.P. brass angle valve for basin mixerand gyser points _of approved make conforming to IS : 8931a) 15 mm nominal bore |
| 113 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS : 8931a) 15 mm nominal bore |
| 114 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank lSI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid lSI license]. |
| 115 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) R.C.C. top slab with 1 :2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finsihed with a floating coat of neat cement complete as per standard design.Inside size 90x80 em and 45 em deep including C.l. cover with frame (light duty) 455x61mm. internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With F.P.S. bricks with class designation 75 & with (a) Crushed stone aggregate (b) Nallah stone aggregate |
| 116 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 117 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 118 | Providing and Fixing white vitreous china based urinal partition including fixing to wall with suitable brakcets all as per manufactureres specification and direction of Engineer-in-charge |
| 119 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes75 mm diametre |
| 120 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 121 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C waste fittings complete:32 mm dia |
| 122 | Providing and fixing carbon steel galvanized (minimum coating 5 micron)dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2) counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete masonry etc. as per direction of Engineer-in- charge.10x140mm |
| 123 | 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 124 | Providing and fixing bright /matt finished Stainless Steel (Grade 316) handles of approved quality & make with necessary screws etc. all complete. 300mm long as per approved Design(make ) for Glass door shutter |
| 125 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Flashings/ Aprons.(Upto 600 mm) |
| 126 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with waterproofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 127 | Carriage of material from source to site of work. |
| 128 | Sand (Average lead 55 km) |
| 129 | Aggregate (Average lead 25km) |
| 130 | Bricks (Average lead 60 km) |
| 131 | Electrical Works |
| 132 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. - Group-C |
| 133 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. Mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 134 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 135 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 136 | 2 x6 sq.mm +1 x 6 sq.mm earth wire |
| 137 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required(Make: - Legrand (Mylinc) / Havell's (Coral) |
| 138 | Modular Switch 6-10 Amp |
| 139 | Modular Switch 16-20 Amp |
| 140 | Modular Socket Oulet 3 pin 5/6 A |
| 141 | Modular Socket Outlet 6 pin 15/16 A |
| 142 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (Make: - Legrand (Mylinc) / Havell's (Coral) |
| 143 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(Make: - Legrand (Mylinc) / Havell's (Coral) |
| 144 | 3 Module (100 mmX75 mm) |
| 145 | 4 Module (125 mmX75 mm) |
| 146 | 6 Module (200 mmX75 mm) |
| 147 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make: - Havell's/ ABB/ Schinder/ Legrand/ L&T) |
| 148 | 6- way, Double door |
| 149 | 12- way, Double door |
| 150 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: - Havell's/ ABB/ Schinder/ Legrand/ L&T) |
| 151 | Single pole |
| 152 | Single pole and neutral 40 Amp. |
| 153 | Supply,Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required |
| 154 | LED Tube fitting 20 Watt 4 feet long. |
| 155 | LED Tube fitting 10 Watt 2 feet long. |
| 156 | LED ceiling Lights 12 watt |
| 157 | Supply,Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 158 | Supply, Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as requiredUpto 450 mm sweep (12\\") |
| 159 | Supply, Installation, Testing and Commissioning of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 160 | Upto 35 Sq.mm (XLPE Al.Cable 2 Core 16 Sq.mm , Armoured) |
| 161 | Upto 35 Sq.mm to 95 Sq.mm (XLPE Al.Cable 3.5 Core 50 Sq.mm , Armoured) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail