Tender For Supply Installation Testing and Commissioning of New Air Conditioners At Ayushman Arogya Mandir Babar Road, Charkha Museum Palika Parking And Other Ndmc Officers In North Of Kartavya Pathi.
Name of Work:- SITC of new air conditioners at Ayushman Arogya Mandir Babar Road, Charkha Museum Palika Parking and other NDMC officers in north of Kartavya Pathi.
Sl. No.
Item Description
1
SITC of window AC 1.5 TR. capacity with remote control, 5 star rating, inverter type, operation on 230V, 50HZ, cooling and condenser coil made by copper, single phase supply having ISEER as 3.30 & above and considering limited manufactures of this rating /type, fins manufacturing ACs having nominal marketing capacities 1.6 Ton & above (acceptable negative 5% tolerance of name plate rated capacity of 1.6 TR. ) as per specification enclosed with guarantee period of 02 years. Supplying of seasoned teak wood frame made out of 2”x3”/1.5”x4” (NS) teak wood, suitable for 1.5/2 TR. capacity window type AC the work including making modification on frame with same material (teak wood) to suit the AC (the frame should be duly varnished) including providing 6 mm. thick ply wood and painted with enameled paint to suit the wall color around AC and providing packing to prevent the heat leakage from inside and outside the room including making connection of AC installation, testing and commissioning etc. as required. (Make: Hitachi, O General, Mitsubishi )
2
SITC of Split type Air-Conditioners 1.5 TR. capacity invertors type with remote control with 5 star rating operation on 230V, 50HZ, cooling and condenser coil made in copper, single phase supply having EER as 4.50 & above and nominal marketing capacity of 1.5 Ton & above and as per specification enclosed. With guarantee period of 02 years installation with 4 No. brass heavy duty flair nut, including P/F of suitable size of copper pipe up to 6 Mtr. length duly insulated with foam insulation in surface/recess in wall and covering with PVC channel of 4\\"x2\\" size or X\\" dia PVC flexible pipe (whereas is required), P/F rigid PVC pipe heavy duty 25 mm. Dia complete with all accessories such as elbow, nipple, socket etc: Supplying, connection, interconnection with 3 Core PVC insulated and PVC sheathed copper conductor flexible wire of size 80/0.20 mm. dia (NS) with plug top (wherever is required), etc. As required at site of work.(Make: Hitachi, O General, Mitsubishi)
3
Providing Fixing of suction and discharge copper pipe for 1.5 Tr.. Capacity for split type AC including 3-core PVC insulated wire of suitable size and PVC pipe for drainage with foam insulation in surface/ recess in wall complete as required at site.
4
Supply installation testing & commissioning of Tower AC 4 Tr. capacity floor standing high air flow type Air conditioners fitting with rotary energy efficient compressor copper condenser coil high air circulation low noise level indoor operating refrigerant R-410a green gas or equivalent refrigerant suitable for floor mounting conforming to suitable IS code amended upto date and air conditioning suitable for operation 430 volt 50 Hz , 5star rating 3- phase AC supply capable of operating with full functioning cordless remote controller including making necessary foundation for indoor units for elevation complete as per site requirement with one year guarantee period make: Mitsubishi/ Daikin/ O general.
5
Supply, Installation, Testing & Commissioning of high pressure copper refrigerant piping suitable for R-32 / R-410 a refrigerant of following size as required and duly insulated closed cell elastomeric nitrile rubber insulation in tubing form. External Refrigerant piping shall be laid under the 1.5 feet ground level deep. Piping inside occupied spaces shall be supported by using Supplying & fixing of suitable PVC pipe size 76.2 mm dia. The trench of refrigerant should be covered with cement based plaster. Entire refrigerant piping work be Carried out in accordance with the specifications as under 28.6 mm dia/19 mm thick insulation
6
9.5mm dia/13 mm thick insulation
7
Less Credit for old split AC 1.5/2 Tr.
8
Less Credit for old Window AC 1.5/2 Tr.
9
Less Credit for old Cassette ACs 4 Tr. Please Enable Macros to View BoQ information