| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in PVC casing caping with modular switch modular plates suitable size modular surface box of specified Category and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.;(c) Group C -- with Cat B Modular Accessories |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independent PVC casing capping of appropriate size as required.;(c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm casing ) |
| 3 | Supply of 4 core armoured PVC/XLPE insulated PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;4 Core 25 sq.mm |
| 4 | Supply of 3 core unarmoured PVC/XLPE insulated PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;3 Core 2.5 sq.mm |
| 5 | Supply of 4 core armoured PVC/XLPE insulated PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;4 Core 4 sq.mm |
| 6 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface etc. complete as required |
| 7 | Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required.;(b) 25 mm |
| 8 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade complete as required.;(6) 4 x 25 Sq. mm. |
| 9 | Supply and erecting of 48 inch (1200mm sweep) ceiling fan double ball bearing type complete with all accessories.;(b) Cat B |
| 10 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required;(b) Cat B |
| 11 | Supplying and fixing following size modular PVC box alongwith modular base and cover plate for modulator switches in recess etc. as required;(h) 1 or 2 Module Cat B |
| 12 | Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 1 no 6 pin 15/16 A modular socket outlet and 1 nos 15/ 16 A modular switch connection painting etc. as required. ( For workstations);(b) Cat B |
| 13 | Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required.;(b) Cat B |
| 14 | Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/Isolator);(n) 8 way double door Cat B |
| 15 | Supplying and fixing 6 A to 32 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(a) SP Cat A |
| 16 | Supplying and fixing 6 A to 32 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(c) DP Cat A |
| 17 | Supply, installation testing and commissioning of LED 22 W, Luminaire make Havells, ( Cat no. LUMINEBS22WLED865SPCWH) or Equivalent in Crompton / Bajaj / Phillips / Legero . Complete as required. (Equivalent to be approved by Engineer incharge ) |
| 18 | Supply, Installation, testing and commissioning of Pump Control Panel, fabricated out of 16SWG CR sheet, powder coated, mounted on 40x40x6mm Angle frame comprising ofIncomer:100Р3P МССВ, 35KA,- 1no160A Al. Bus bar TPN - 1setEarth leakage relay with CBCT - 1 noMF meter, CT's and RYB lampsOutgoing:* 5no 3HP 3ph,DOL starter with 20A TP MCB, TP contactor, over load relay and single phasing relay with on/off push buttons and indicators* 3no 1HP 1ph,DOL starter with 20A SP MCB, 2P contactor, over load relay with on/off push buttons and indicators*All MCCB's MCB's,MCC, MC contactors, etc shall be of L&T, Siemens, Legrand, Havells make only. |
| 19 | Dismantling of old panels, cables , accessories etc and providing all necessary accessories and connections to the new panels complete as required. |
| 20 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI markof approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /lifting arrangement and watering pipe etc. with charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately).;(a) In soily strata |
| 21 | Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt). |
| 22 | Supplying and laying 8 SWG copper wire at 0.5 m below ground level for conductor earth electrode including soldering etc. as required |
| 23 | Supply and laying of service wire for providing connection to light fittings complete as required. Please Enable Macros to View BoQ information |