| 1 | Supply of steel tubular pole 11 Metre long designated 410 SP-56 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect UPREC P-30 |
| 2 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 |
| 3 | Supply of 185 sq. mm 3 core high conductivity aluminum strand compacted circular conductor XLPE armoured 11 KV(E) Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment complete in all respects as per direction of E/I. (Gloster/Universal/Polycab/ Havells/Diacab/KEI make) |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required..(DSR elect 2018 Item.N. 8.3.2 Above 120 Sqmm and upto 400 Sqmm |
| 5 | S/F of jointing of following sizes outdoor/indoor type 11 KV jointing kit heat Shrinkable type for 11 KV Cable including cost of all material, labour, T&P etc. for proper completion of the E/I. (Raychem/Denson Make) uperc Pg-41 120 Sqmm |
| 6 | S/L of 3\\" (80mm) dia G.I. Pipe 'B' Class in the ground level including road cutting Complete in all respects as per direction of E/I DSR Electrical-18 12.38 |
| 7 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PS No. 501 (Make-Havells/Grandley/Polycab/ Diatron/Gloster/Kalinga). 400 sqmm x 3.5 core |
| 8 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making onnection etc. complete in all respect as per direction of the Engineer-Incharge. PS No. 504 d) 185 sqmm |
| 9 | c) 400 sqmm |
| 10 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing ead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (B) |
| 11 | Supply and laying of 25 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect.PS No. 716 |
| 12 | Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects P.S. No. 627 |
| 13 | S/f of 11 KV Pin Insulator complete with large steel head G.I. Pin, nuts, washer etc. as required. DSR-2018/13.10 |
| 14 | S/f of 11 KV Disc insulator for 11KV Overhead lines with galvanished insulator fittings, ball and socket type and complete with galvanished stain clamp, bolt nut, washer etc. as required DSR-2018/13.11 |
| 15 | S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE 100 (PE 400) grade as per IS code 4984 with excavation at a depth of 1.20 Mtr below ground level i/c the cost of cutting of pipes for making up to length and making joints complete all respects as per direction of E/I. (creator poly extrusion/duraline/rex/times/ narander plast/pioneer make). (AOR) |
| 16 | S/F of straight MS channel 50x100 mm (9.2 per kg) 1.5 mtrs long including S/E of suitable clamp made of MS flat 50x6 mm including all nuts and bolts fixing on pole. T off channel UPERC P-48 |
| 17 | Numbering of poles with combination of yellow and black colour paint etc. complete in all respects as per direction of E/I (AOR) |
| 18 | Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect. PS No. 634 |
| 19 | Supply of Top MS Channel 100x50x2240mm as per design complete in all respects UPERC P-39 |
| 20 | Dismantling of PCC pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. DSR Electrical 2018/ I. No. 12.42 |
| 21 | Supply and laying 120 mm dia DWC ( Double wall corrugated pipe across the road by Trenchless method (Manual). Complete in all respect as per direction of E/I. (AOR) |
| 22 | Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. DSR Elect 2018/I-12.40 |
| 23 | Demolishing Cement Concrete manually by mechanical means including disposal of material within 50 mtr lead as per direction of Engineer-in-Charge, Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) DSR Civil 15.2.1 (AOR) |
| 24 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate moorum screening, red bajri and labour required. i) bituminious portion (AOR) |
| 25 | ii) water bound macadam (AOR) |
| 26 | Cement Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.07/S.N. 279 |
| 27 | Cement Concrete with 4cm gauge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.08/S.N. 281 |
| 28 | Taking out existing c.c. interlocking paver blocks from foothpath/central verge, including removal of rubbish etc. disposal of unserviceable material to the dumping ground, for which payment shall be made seperately and stacking off serviceable material withing 50 mtr lead as per direction of E/I (AOR) |
| 29 | Laying Old cemennt concrete interlocking paver blocks of any design/shape laid in required line, level currative colour and pattern over and including 50mm thick compacted bed of course sand filling the joint with fine sand etc. all complete as per direction of E/I (Old CC Paver block shall be supplied by the deptt free of cost) (AOR) Please Enable Macros to View BoQ information |