| 1 | Civil Work |
| 2 | Class-150 brick work in 1 : 4 cement and f sand mortar in the super-structure in 1/2 brick thick wall i/c supply of all materials, labour and T & P etc. required for proper completion of the work. |
| 3 | 12 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) |
| 4 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth Complete. |
| 5 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 6 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on both faces of shutters: 35MM THICK |
| 7 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 8 | PProviding and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 9 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators I/C all work. |
| 10 | E/W in Excavation in foundations in ordinary soil including dressing of sides and rammings of bottom. |
| 11 | Providing and laying PCC 1:4:8 (1 cement : 4 fine sand : Brick ballast 40 mm. nominal size) in foundation i/c supply of all materials. Labour and T&P etc. |
| 12 | Class-150 brick work in 1 : 6 cement and C. sand mortar in the Foundation including necessary cutting and moulding of bricks as required and also including supply of all materials, labour and T & P etc. required for proper completion of the work. |
| 13 | R.C.C. work in Foundation with cement approved coarse sand and 20 mm gauge approved stone grit in the proportion of 1:1 1/2:3 i/c supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also i/c supply of all materials, labour and T & P etc. |
| 14 | Providing and laying RCC 1:1 1/2:3 (1 cement : 1 1/2 C. sand :3 Stone grit 20 mm. size) in Plinth bend, Top bend i/c supply of all materials. Labour and T&P etc. |
| 15 | Centering and Shuttering i/c strutting, propping etc. and removal of form work for Foundation, Columns, Slab etc. |
| 16 | Mild steel or iron in plain work shch as reinforced concrete work i/c cutting , bending. |
| 17 | Class-150 brick work in 1 : 4 cement and C. sand mortar in the super-structure One brick thick wall i/c supply of all materials, labour and T & P etc. required for proper completion of the work. |
| 18 | E/W in Excavation in foundations in ordinary soil and disposal malwa out of 1Km. Distance from site and including dressing of sides and rammings of bottom. SI No. - 251 |
| 19 | E/W in cutting or filling in embankment in ordinary soil i/c ramming dressing and leveling the same to required level and slope. as per SI No. - 253 |
| 20 | Providing and laying PCC 1:6:12 (1 cement : 6 fine sand : 12 graded brick aggregate 40 mm. nominal size) i/c supply of all materials. Labour and T&P etc. SI No. 273 |
| 21 | Class-150 brick work in 1 : 4 cement and coarse sand mortar including necessary cutting and moulding of bricks as required and also including supply of all materials, labour and T & P etc. required for proper completion of the work. SI No.305 |
| 22 | 12 mm thick plaster work |
| 23 | 25 mm thick cc in 1:2:4 |
| 24 | Laying C.C. Road slab consisting of 1:1 1/2:3 Cement, C.Sand and App. 20 mm GAUGE stone grit over prepared subgrade after its rectification bringing it to proper camber i/c supply of all materials, labour and T & P etc. required for proper completion of the work. SI No. 773 a. |
| 25 | G.I. Pipe Class B 15 mm. dia |
| 26 | G.I. Pipe Class B 20 mm. Dia |
| 27 | G.I. Pipe Class B 25mm. dia |
| 28 | C.P. Bib cock heavy quality 15mm dia Ch. 21 Sr. 44 |
| 29 | Stop cock heavy quality 15mm dia Ch. 21 Sr. 46 |
| 30 | Supply and hosting of low density polythene seamless one pease moulded tanks and placing the same in proper position for 500 leter as per 730 NBO |
| 31 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 32 | Wash hand basin 550x400 mm size of white glazed earthen ware (22\\"x16\\") as S.no.12 |
| 33 | Mirror of Atul make with Indian polish of 600x450 mm dia size with bevelled edge Each 16 |
| 34 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with mdular type switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 35 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 36 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 37 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. |
| 38 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. |
| 39 | Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc.as required. |
| 40 | Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections,painting etc. as required. |
| 41 | Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 poles and earth metal enclosed plug top along with 20 amps. \\"C\\" curve, SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. |
| 42 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB)suitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required. |
| 43 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 40 Amps |
| 44 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 63 Amps |
| 45 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. asrequired. 40 amps. |
| 46 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. asrequired. 63 amps. |
| 47 | Supplying and fixing following way, SP&N, sheet steel, MCB distribution board, 240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB / Isolator) |
| 48 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcludingmodular plate etc. as required. 5/6 A switch |
| 49 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcludingmodular plate etc. as required. 3 pin 5/6 A socket outlet |
| 50 | Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspendedcomplete in all respect. |
| 51 | Supply of 225/230mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. Please Enable Macros to View BoQ information |