| 1 | SOLAR WATER GEYSERDisconnecting of water connection and dismantling complete solar water heating system of capacity 300 ltrs per day including hot & cold water pipes and hot water tank complete and refixing after repairing the system fixing back in position and testing complete all as specified and directed by Engineer-in-charge.Note : Rates quoted by the contractor shall deemed to be included for :-(a) Making good the worn out missing nuts bolts, washers, union, sockets, flanges and screws etc.(b) Descaling/ desludging, cleaning and washing of the solar panel, hot water pipes, copper tubes, hot and cold water tanks by using appropriate chemicals and re-assembling the panel including welding of collector fins as required.(c) Painting of staging, solar panel frame, hot water tank frame with applying one coat of synthetic enamel paint incl preparation of old painted steel surfaces of any description(e) All other materials shall be measured and paid separately under respective items. |
| 2 | All as per items No 01 here in before but of capacity 200 ltrs per day complete all as specified and as directed. |
| 3 | All as per items No 01 here in before but of capacity 100 ltrs per day complete all as specified and as directed. |
| 4 | Supply only solar energy collector panel made of aluminium body with toughened glass complete with copper fins of capacity upto 300 ltrs per day complete all as specified and as directed. |
| 5 | Supply only as in replacement, solar panel toughened glass having thickness 5mm all as per the existing model of system complete all as specified and as directed. |
| 6 | Supplying only as in replacement, solar panel gasket made out of fine rubber to make system air tight, dust and water proof complete all as specified and as directed.(8 RM per panel) |
| 7 | Supplying only as in replacement, copper tubes with collectors fins for solar energy collector panel complete of same dia and thickness as per existing, brazing by copper alloy brazing rod with the existing inlet/outlet hot/cold water pipes to make the panel water tight complete all as specified and as directed. |
| 8 | Supply only compressed glass wool 48 mm thick between solar energy collector panel copper tubes frame and aluminum body panel including securing it on panel by means of necessary adhesives all as complete all as specified and as directed. |
| 9 | Supply only solar energy collector panel manifold 1.40 mtr long, made of 20mm dia copper tube having 1 No MS flange 74 mm dia welded at each end duly drilled for nuts & bolts complete all as specified and directed by Engineer-in-charge. Note : Rate quoted deemed to be included for welding of solar collector tubes with manifold complete all as specified and as directed. |
| 10 | S&F hose pipe for hot/ cold water for solar system of suitable length as existing size complete with 02 Nos clamps complete all as specified and as directed. |
| 11 | Supply only auxillary tank for make up tank to reduse pressure of solar system complete all as specified and as directed. |
| 12 | S&F Electrical backup heater of 2 KW for solar system with all electrical connection complete all as specified and as directed. |
| 13 | S&F Electrical backup heater of 3 KW for solar system with all electrical connection complete all as specified and as directed. |
| 14 | Descaling solar energy collector panel made of aluminium body with toughened glass complete with copper fins of capacity 100/200/300 ltrs per day complete all as specified and as directed. |
| 15 | Descaling of hot water storage tank of food grade stainless steel 100 ltr capacity complete all as specified and as directed. |
| 16 | Descaling of hot water storage tank of food grade stainless steel 200 ltr capacity complete all as specified and as directed. |
| 17 | Descaling of hot water storage tank of food grade stainless steel 300 ltr capacity complete all as specified and as directed. |
| 18 | M&L for insulation of hot water pipe with glass wool and covering with aluminium sheet cladding 25 gauge for 20mm bore GI pipe complete all as specified and as directed. |
| 19 | S & F rotational moulded polythene water storage tanks, white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Litres complete all as specified and as directed. |
| 20 | S & F in repairs ball brass valves high pressure with polythene float and fly nuts complete, screwed for iron pipe and fixed 15mm bore complete all as specified and as directed. |
| 21 | S & F in repair ball brass valve 20mm bore dia high pressure with polythene float and fly nuts complete screwed with iron pipe and fixed complete all as specified and as directed. |
| 22 | S & F in repairs gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 20mm bore as in repairs complete all as specified and as directed. |
| 23 | S & F in repairs gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 15mm bore as in repairs complete all as specified and as directed. |
| 24 | S & F in repairs glass wool insulation with aluminium cladding for 25 mm bore pipe complete all as specified and as directed. |
| 25 | Supply and filling distilled water to solar geyser for various capacity complete all as specified and as directed. |
| 26 | GEYSETaking down the existing unsv storage type electric water heater (geyser)of any make/ capacity, installed at different location including dis-connecting, taking down opening all parts/accessories for inspection, cleaning, descaling, refixing serviceable parts, replacing unserviceable parts installed at old location and reconnection, testing complete all as specified and as directed. for the follwoing capacity :- 25 Ltr capacity |
| 27 | All as per item No 26 above, but 35 Ltr capacity complete all as specified and as directed. |
| 28 | All as per item No 26 above, but 50 Ltr capacity complete all as specified and as directed. Note :- (a) The rates of item No 26 above deemed to include the labour charges for fixing of new parts as required .The new parts required shall be paid as supply only under item No 29 to 40 here in after. (b) Serviceable materials obtained from item No 1 above shall be refixed and labour charges for the same are included in unit rate of Item No 1 above. (c ) Other item shall be paid as mentioned here in after. |
| 29 | Supply only heating element round type of geysers including rubber washer for the following capacity complete all as specified and as directed :- (a) 1500 Watt capacity |
| 30 | (b) All as per item No 29 above, but 2000 Watt capacity complete all as specified and as directed. |
| 31 | Supply only PVC connection pipe with brass unions at both ends, 450mm long 15mm bore (for incoming cold water) complete all as specified and as directed. |
| 32 | Supply only chromium plated copper connection pipe 450mm long with two brass adopters washers and connecting up complete all as specified and as directed. |
| 33 | Supply only apparatus plate suitable for 25 ltrs capacity geyser.(Make : Bajaj/Recold) complete all as specified and as directed. |
| 34 | Supply only apparatus plate suitable for 35 ltrs capacity geyser complete all as specified and as directed. |
| 35 | Supply only apparatus plate suitable for 50 ltrs capacity geyser complete all as specified and as directed. |
| 36 | Supply only thermostat (ISI Marked) for 25/35/50 Liters capacity Geyser.(Make: Elcon, USHA or Equivalent ISI marked) complete all as specified and as directed. |
| 37 | Supply only thermostat (ISI Marked) for 25/50 Liters capacity Geyser for Racold geysers complete all as specified and as directed. |
| 38 | Supply only steel tanks 25 liters and refixing after testing the leakage complete incl replacement of insulating material (Glass wool) for 25 Liters capacity Geysers and replacement of rubber packaging ring heat resistsnt type complete all as specified and as directed. |
| 39 | Supply only steel tanks 35 liters and refixing after testing the leakage complete incl replacement of insulating material (Glass wool) for 35 Liters capacity Geysers and replacement of rubber packaging ring heat resistsnt type complete all as specified and as directed. |
| 40 | Supply only steel tanks 50 liters and refixing after testing the leakage complete incl replacement of insulating material (Glass wool) for 50 Liters capacity Geysers and replacement of rubber packaging ring heat resistsnt type complete all as specified and as directed. |
| 41 | Supply & Fixing Plug top, 3 pin, 15 amps, 230 volt, including electric connection after taking out old unserviceable one complete all as specified and as directed. |
| 42 | S&F stop valve, ISI marked, brass, 15mm bore after taking out defective/ unserviceable one complete all as specified and as directed. |
| 43 | M&L for concealed sub main wiring with 3 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit complete all as specified and as directed. [NOTE : (i) Three run of submain wiring cable alongwith 20mm PVC conduit pipe shall be measured as one unit length]. |
| 44 | M&L for sheet metal enclosure MCB distributon board, 2 way single door 230 volts complete all as specified and as directed. |
| 45 | S&F in replacement safety nut for pressure release valve (as per sample) complete all as specified and as directed. |
| 46 | S&F in replacement hole fastener 10 mm dia, 100 mm long including nut and washer complete all as specified and as directed. |
| 47 | S&F non return valve complete all as specified and as directed. |
| 48 | S&F in replacement rubber gas Kit suitable for 50/25 ltrs capacity geyser (as per sample) complete all as specified and as directed. |
| 49 | M&L for fixing of new/old geysers at new place with hole fastener and cement work including connection with existing pipes complete all as specified and as directed. |
| 50 | FANSTaking down ceiling fan any size from its location including disconnecting from ceiling rose, after removing carefully false celing/ ceiling wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosine oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing, locking nut, screw, split pin, check nut, rubber real wherever required tightening of stator up and bottom cover in position; washing body, blades, canopies with detergent soap powder; preparation of old painted surfaces by filling cavaties with suiatble filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing and re - hanging fan and false ceiling in position and making electric connection complete all as directed. (Spare wherever required to be renewed shall be measured and paid vide under respective item supply only). |
| 51 | Material and labour for removing the defective/burnt ceiling fans winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, with required Number of turns and including all insulating material s such as insulating tape,cloth and sleeves, varnishing and drying, greasing amd making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts and testing and brouught at site complete all as specified and as directed. Note: (i) Winding shall be carried out by winding machine. |
| 52 | Taking down exhaust fan 300/380/450 mm sweep of any size from its location including disconnecting from ceiling rose, after removing carefully wall wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosine oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing, locking nut, screw, split pin, check nut, rubber real wherever required tightening of stator up and covers in position; washing body, blades, with detergent soap powder; preparation of old painted surfaces by filling cavaties with suiatble filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing and refixing fan to wall in position and making electric connection complete all as specified and as directed. (Spare wherever required to be renewed shall be measured and paid vide under respective item supply only). |
| 53 | Material and labour for removing the defective/burnt Exhaust fans of sweep 380/450 mm of any make and type stator winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, with required Number of turns and including all insulating material s such as insulating tape,cloth and sleeves, varnishing and drying, greasing amd making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts and testing and brouught at site complete all as specified and as directed. Note: (i) Winding shall be carried out by winding machine. |
| 54 | Material and labour for removing the defective/burnt Exhaust fans of sweep 300 mm of any make and type stator winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, with required Number of turns and including all insulating material s such as insulating tape,cloth and sleeves, varnishing and drying, greasing amd making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts and testing and brouught at site complete all as specified and as directed. Note: (i) Wnding shall be carried out by winding machine. |
| 55 | Taking down wall mounted / padestal fan of 600mm sweep any size from its location including disconnecting from ceiling rose, after removing carefully false celing wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosine oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing, locking nut, screw, split pin, check nut, rubber real wherever required tightening of stator up and covers in position; washing body, blades, with detergent soap powder; preparation of old painted surfaces by filling cavaties with suiatble filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing and re - hanging fan and false ceiling in position and making electric connection complete all as specified and as directed.. (Spare wherever required to be renewed shall be measured and paid vide under respective item supply only). |
| 56 | Material and labour for removing the defective/burnt pedestal fans of sweep 600 mm of any make and type stator winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, with required Number of turns and including all insulating material s such as insulating tape,cloth and sleeves, varnishing and drying, greasing amd making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts and testing and brouught at site complete all as specified and as directed. Note: (i) Wnding shall be carried out by winding machine. |
| 57 | S&F in replacement of ball bearings No 6201,6202,6203, 6204 or any other size required for old vintage ceiling fans / exhaust fans/ pedastal fans Make: SKF / NBC complete all as specified and as directed. |
| 58 | S&F in replacement of bronze bush of suitable size for ceiling fans of any size and make including greasing with approved quality of grease complete all as specified and as directed. |
| 59 | S&F in replacement of capacitor 2.5/4.0 mfd for ceiling fan complete all as specified and as directed. |
| 60 | S&F in replacement of capacitor 4.0 mfd for ceiling fan complete all as specified and as directed. |
| 61 | S & F Fan shaft ( as sample ) suitable for motor of ceiling fan 1200/1400 mm sweep complete all as specified and as directed. |
| 62 | S&F in replacement of PVC connector block 4 way with fixing nuts and clamps complete all as specified and as directed. |
| 63 | M&L for Painting of ceiling fans including blades with applying two coats of synthetic enameled paint over a coat of red oxide primer by using spray painting machine on old prepared surface including writing of MES No using synthetic enamel paint black colour complete all as specified and as directed. |
| 64 | Supply and fixing upper canopy and down canopy for ceiling fans suitable for any make and sweep all as specified and as directed. |
| 65 | Supply and fixing in repair hanging clamp suitable for ceiling fans of any make and type with rubber real, nuts, bolts and washers of suitable size including locking pin complete all as specified and as directed. |
| 66 | S&F in replacement of Metal Fan blade suitable for Ceiling Fan 1200 mm sweep complete all as specified and as directed. |
| 67 | S&F in replacement of Metal Fan blade suitable up to 300 mm sweep Exhaust fan (As per exixting sample) complete all as specified and as directed. |
| 68 | S & F in replacement of PCB Card for BLDC Remote Fan(Energy efficient) of make Havells, Orient & Bajaj complete all as specified and as directed. |
| 69 | Taking down carefully old/unsv copper/alluminium any type of point wiring for one light, socket, fan, bell or power etc incl all fittings such as switches sockets, holders, light fittings, fan requlators, call bell etc and making good the disturbed surface of wall ceiling complete all as specified and as directed. |
| 70 | M&L for Concealed type Point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core malti stranded copper FRLS cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in including PVC conduit of adequate size having a wall thickness not less than 1.5 mm with all accessories (including cutting chases & making good the disturbed surface to its original specification) including 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor FRLS cable as earth continuity conductor connected to main switches/DB's or common earth dolly complete all as specified and as directed for the following:- One light point controlled by one way switch 5/6 amps. complete all as specified and as directed |
| 71 | All as per item No 70 above but,One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps. complete all as specified and as directed. |
| 72 | All as per item No 70 above but, One socket out let 5/6 amps point on the independent board complete all as specified and as directed. |
| 73 | All as per item No 70 above but,One socket out let 5/6 amps point on the same board complete all as specified and as directed. |
| 74 | All as per item No 70 above but,One bell/buzzer point controlled by one bell push button complete all as specified and as directed. |
| 75 | All as per item No 70 above but, One light point controlled by two way switch 5/6 amps. complete all as specified and as directed. |
| 76 | All as per item No 70 above but wiring with 2.5 sq mm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and as directed |
| 77 | S&F in repair switch piano flush type 5/6 amps single pole one way complete all as specified and as directed. |
| 78 | S&F switch piano flush type 5/6 amps single pole two way complete all as specified and as directed. |
| 79 | S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and asdirected. |
| 80 | S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and as directed. |
| 81 | S&F in repair switch piano flush type 15/16 amps single pole one way complete all as specified and as directed. |
| 82 | S&F in repair Switch socket combination 2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with and including taking down existing unserviceable, complete all as specified and as directed. |
| 83 | S&F in repair switch socket combination 2 in 1, 6 pin 5/6 amps and 15/16 amps multipurpose, white/ivory finish flush non shutter non inter locking type with and including taking down existing unserviceable, complete all as specified and as directed. |
| 84 | S&F in repair bell/buzzer push 5/6 amps flush type white/ivory finish complete all as specified and as directed. |
| 85 | S&F in repair ding dong bell malti music type, AC, Single pole, 220/240 Volts, surface type complete all as specified and as directed. |
| 86 | S&F in repair ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed. |
| 87 | S & F in repair lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed. |
| 88 | S & F in repair deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and as directed. |
| 89 | S&F LED white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and as directed. Make: Surya/Havells/Philips/CG. |
| 90 | S&F in repair modular switch 6 Amp of ABB make as per site one module complete all as specified and as directed. |
| 91 | S&F in repair modular swith 16 Amp of ABB make as per site one module complete all as specified and as directed. |
| 92 | S&F Modular socket 6 Amp 2/3 Pin combined 2 module 230 volt flush type complete all as specified and as directed |
| 93 | S&F Modular socket 6/16 Amp 2/3 Pin combined 2 module 230 volt flush type complete all as specified and as directed. |
| 94 | S & F in repair modular fan regulator 120W 230 volts AC 50 Hz 2 modules complete all as specified and as directed. |
| 95 | S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed. |
| 96 | S&F IP 20, Class I, LED Mirror light fitting 1 x 9 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified and as directed. |
| 97 | S & F Post top lanterns 20 watt LED light fitting(Warm type) ,outdoor new generation, energy saving, environmental friendly, longlife with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, spun aluminium canopy, with opal/clear acrylic diffuser and complete with all accessories intenally prewired including connecting up with three core twisted flexible copper conductor cable up to cealing rose and necessary mounting arrangements, complete all as specified and as directed. |
| 98 | S & F Recess mounting flat panel 35/36 Watt LED fitting (2'X2') for armstrong/ grid ceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mounting arrangements, including necessary connection complete all as specified and as directed. |
| 99 | S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete incl removal of old unsv fitting complete all as specified and as directed. |
| 100 | M&L for sub main wiring with 2 run of 6.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit with and including taking down unsv sub main, complete all as specified and as directed.(NOTE : (i) PVC non rigid nonmetallic conduit shall be measured & paid separately under relevant item of this Schedule ‘A’.(ii)Two run of submain wiring cable alongwith one run of earth wire with and including 25 PVC conduit pipe shall be measured as one unit length). |
| 101 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators complete with and including taking down old unsv one all as specified and as directed. |
| 102 | S & F MCB TPN 415 volts suitable for fixing in MCB DB of capacity 40 to 100 amps complete all as specified and as directed. |
| 103 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators complete with and including taking down old unsv one complete all as specified and as directed. |
| 104 | S&F MCB, Single pole & neutral, 32 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one complete all as specified and as directed. |
| 105 | S&F MCB, Single pole & neutral, 40 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one complete all as specified and as directed. |
| 106 | S&F MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with and including taking down old unsv one complete all as specified and as directed. Please Enable Macros to View BoQ information |