| 1 | Taking down chowkats or frames n. exc. 1.5 sqm with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 2 | All as per Srl Item No 1 above but exc 1.5 sqm but n. exc 4 sqm (without taking of shutters from the frames) complete all as specified and directed. |
| 3 | S&F 35mm thick factory made plain framed panelled shutters of 2nd class hard wood two panels with lock rail of 9mm thick BWP commercial ply. The size of rail and stile as per IS:1003 (part I) kiln seasoned and chemically pressure treated factory made shutters wood is to be incorporated complete all as specified and directed. |
| 4 | S&F Pressed steel frames made out of MS sheet 1.25mm thick of size 105mm x 60mm for doors/windows with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed. |
| 5 | M&L PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in as in back filling of chowkhat complete all as specified and directed. |
| 6 | S&F steel window 1.25mm thick box type (Primer coated) ERW hollow P section of size 85mm x 35mm double rebated comprises gauged,glazed skeleton shutter ERW sec 50mm x 20mm and 1mm thick with two openable leaf consisting two Nos sash bar of T- section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- section of size 30mm x 25mm and 1.25mm thick including cutting holes and making good dismanted portion in PCC M-15, type B-0 (04 Nos for each window, steel duly painted with ones shop coat of Zinc chromate primer on prepared surfaces) and finishing the surface to match with existing including following fitting welded to frame shutter :-(i) hold fast, 150mm long of 12mm x 3mm made to shape -04 Nos per window. (ii) Handle of Z section 20mm x 25mm, 100mm long-1No per leaf. (iii) MS tower bolt 150mm long-2 No per leaf. (iv) Z section 20mm x 25mm, 100 long stopper -1 No per leaf. (v) Cleat 65mm long of hollow square 15mm x 20mm x 63mm welded to hinge- 1 No per leaf. (vi) Mild steel pintle hinge of size 75mm x 12mm - 2 No per leaf. (vii) flat iron fillets of size 20 x 3mm for fixing wire gauge, complete all as specified and directed. |
| 7 | S&F steel ventilators with center hung shutter including two pairs of brass cup pivoted catch spring and pulley wheel complete all as specified and directed. |
| 8 | Galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, or galvanized wire staples complete all as specified and directed. |
| 9 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares n exc. 0.5 sqm in each pane complete all as specified and as directed. |
| 10 | S&F aluminium alloy, anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed 250mm long complete all as specified and directed. |
| 11 | S&F anodised aluminium barrel tower bolt extruded section size 200mm size complete all as specified and directed. |
| 12 | S&F anodised aluminium handle cast type 125mm size complete all as specified and directed. |
| 13 | Preparation of new or previously untreated steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 14 | M&L for two coat of synthetic enamel paint over a coat of pink primer on new or previously untreated wooden based or wooden surfaces of any description not otherwise described, over 10cm width or girth complete all as specified and directed. |
| 15 | Demolition of stone or brick masonry built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work etc complete all as specified and directed. |
| 16 | M&L for stone walling of random rubble with best quality locally available harder stone such as granite, trap or basallt brought upto courses well bonded bedded, solidily hearted and built in cement mortar 1:6 complete all as specified and directed. |
| 17 | All as Srl Item No. 16 above but except stone. |
| 18 | Taking down cement plaster/Pointing on brick walls or stone walls any discription etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 19 | M&L for 15mm thick plaster with water proofing compound in CM 1:4 on bricks or concete surfaces finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 20 | M&L rendering and plastering work with WPC 5mm thick in CM 1:4 bricks or concrete surfaces finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 21 | Rendering 10mm thick in cement plaster on other than fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed. |
| 22 | Prepartion of plastered surface of wall by applying 1.5mm wall care putty in two layer and making the surface smooth with sand paper and applying two coat of OBD over new/old surfaces complete all as specified and directed. |
| 23 | M&L rendering or plastering work with WPC 5mm thick in CM 1:3 in water sump fascia/edges/ceiling of chajjas and roof projection etc. including taking out peeled out of plaster/concrete and making the line in true shape and finishing the surface without using extra cement complete all as specified and directed. |
| 24 | Supply only liquid water proofing compound |
| 25 | Demolition of cement concrete in ground floor and paving, n exc. 15cm thickness (below and above ground level), un- reinforced complete all as specified and directed. |
| 26 | M&L PCC 1:3:6 type C2 (40mm graded crushed stone aggregate) as in plinth protection 75mm thick complete all as specified and directed. |
| 27 | M&L for chequered cement concrete tiles with grey cement and not pigment 30cm x 30 cm x 25mm thick, set jointed and pointed in neat cement slurry and in floors laid over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed. |
| 28 | PCC M-15, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in floor, 25mm thick, finished even and rough to receive floor finishes complete all as specified and directed. |
| 29 | M&L cement concrete type C2, 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) in foundation filling and mass concrete complete all as specified and directed. |
| 30 | Dismantling of corrugated or plain steel sheeting of any gauge thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed. |
| 31 | Pre painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips,valley gutters, roof covering/ cladding fixed with self tapping screws complete all as specified and directed. |
| 32 | Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws complete all as specified and directed. |
| 33 | Dismantling of wall and ceiling boarding (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, with nails including cover fillets and removing from site complete all as specified and directed. |
| 34 | M&L false ceiling using anodised aluminium T&L section snap grid frame work of size 600mm x 600mm including hangers 6mm dia GI(upto1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of G.I. flat 40mm X 3 mm size 60mm long complete with 4mm thick non asbestos fiber cement board ISI marked Eboard colour coaated and designed complete all as specified and directed. |
| 35 | M&LPCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in copings, benching cills, pcc gola, roof kerbs and the like including weathering, slightly rounded or chamfered on edges directed mixwd with water proofing compound (water proofing compound shall be measured separately) complete all as specified & directed. |
| 36 | Dismantling or frameed work timber scantlings 40 sqcm and over in section, in any position complete all as specified & directed. |
| 37 | M&L for 2nd class hardwood as in scantling, framed work as in ceiling, clean sawn timber and fixed in any position complete all as specified & directed. |
| 38 | Dismantling wrouht iron or mild steel work of any description not otherwise provided complete all as specified & directed. |
| 39 | S&F framed work as in doors or gates of angle or other section,rails, braces, etc., complete,drilling for fixing of steel sheeting or other covering. Doors to be prepared for hanging or sliding with and including either hooks and hinges or steel door fittings also fastening and fixing complete all as specified & directed. |
| 40 | M&L for applying two or more coats of 100% premium acrylic emulsion paints having VOC less than 50 gms/litre, and UV resistance as per IS 15489-2004,alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additived @1.43 litre/10 sqm over and including priming coat of exterior primer applied @0.90litre/10 sqm over new/old surface complete all as specified and directed. |
| 41 | M&L surface prepartion, cleaning/grinding, repair of cracks, honey combs and voids with epoxy mortar application of one coat epoxy primer and two coat epoxy coating of approved make to reqd DFT including curing, protection, cleaning al as in water sump completa by authorised applicator complete all as specified and directed. |
| 42 | M&L for (non-skid), premium class I grade, coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18sqm but n exc. 0.38sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15 mm thick screed bedding layer in CM 1:6, complete all as specified and directed. |
| 43 | Taking down cement plaster/terrazo dado/wall tiling and skirting etc. on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed. |
| 44 | M&L non-skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18sqm but n exc. 0.38sqm, on vertical surfaces such as skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement, laid over and including 10 mm thick bedding layer in CM 1:4 on surafce of walls complete all as specified and directed. |
| 45 | S&F for fixing water level indicator comprasing of CI float oval type 250mm dia at center MS pulley of 150mm dia, mild steel indicator of suitable size permantely marked standard SS rope of 10 mm dia with suitable length for smooth functioning and testing on completion including taking down unsv |
| 46 | Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site and making good distrubed surface of wall, floors, etc. complete all as specified and directed. |
| 47 | Taking down main switches DBs with sheet metal enclosure 12 way SPN DBs etc. complete all as specified and directed. |
| 48 | Dismantling of house service brackets of any size and type and making good the distrubed wall surfaces complete all as specified and directed. |
| 49 | Material and labour for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core in casing caping of 20/25 mm size complete with PVC rectangular block with 3mm thick plastic laminated sheet for mounting switch/ sockets regulators etc.and with 1.5 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one light point controlled by one switch complete all as specified and directed. |
| 50 | All as per serial item No. 49 above but for 3 pin socket outlet point controlled by one, one way switch on the same board complete all as specified and directed. |
| 51 | All as per serial item No. 49 above but for one 3 pin switch socket combination of 5 Amp capacity on independent board complete all as specified and directed. |
| 52 | All as per serial item No. 49 above but for 3 pin switch socket combination of 15 Amp on independent board with cable 2.5 sqmm unsheathed stranded 1100 Volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed. |
| 53 | Supply and fix switch socket combination 2 in 1, 3 pin 5 and 15 Amp flush type complete all as specified and directed. |
| 54 | Supply and fix switch piano type 5 Amp single pole one way complete all as specified and directed. |
| 55 | Supply and fix socket outlet 3 pin 5 Amp flush type complete all as specified and directed. |
| 56 | Supply and fix switch socket combination 2 in 1 , 3 pin 5 Amp flush type complete all as specified and directed. |
| 57 | Supply and fix ceiling rose surface backelite three terminal complete all as specified and as directed . |
| 58 | Supply and fix LED tube light fittings1 x 20 Watt,220 V, AC decorative box type with driver holder including LED tube rodconnecting up with three core flexible copper conductor cable from ceiling rose to tube light fitting complete all as specified and directed. |
| 59 | Supply and Fixing wall security LED light fittings of Cap 18 W suitable for New generation energy saving and environmental friendly long life, light made up of pressure die cast aluminium housing with highly efficient LEDs as Lighting Source and PC cover with integrated lens with IP66 protection and impact resistance of IK07 complete all as specified and directed. |
| 60 | S&F bracket for bldg security light made out of 25 mm GI tubing medium grade 0.60 Mtr long bend to required shape as in bracket for bldg security light fittings, incl drilling hole in pipe for fixing with nut, bolt/screw in building wall complete all as specified and directed. |
| 61 | Supply and fix MCB SPN 240 Volts 32 Amp breaking capacity 10 KA rating complete all as specified and directed. |
| 62 | Supply and fix MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed. |
| 63 | Supply and fix sheet metal enclosure powder painted for MCB SPN 8 way DB double door with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and directed. |
| 64 | S & F PVC rectangular block for mounting, DB,s etc. with 3mm thick plastic laminated sheet cover of size 250x200x50 mm deep complete all as specified and directed. |
| 65 | M & L for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion ® |
| 66 | Supply and fix 16 sqmm, 1100 volts grade heavy duty cable, PVC insulated aluminium stranded condcutor with inner sheathed of PVC tape abd over all PVC sheathed for service connection suspended by insulating hangers not more than 01 mtr apart including 4mm dia suspension wire and twin core cable flat or circular complete in cluding taking down old service connection complete all as specified and directed. Please Enable Macros to View BoQ information |