| Sl. No. | Item Description |
| 1 | M&L for Comprehensive Maintenance of Diesel Generator (DG) Set mentioned at Appx-A, covering all routine scheduled services, running repairs, breakdown maintenance and replacement of all wear-and-tear parts, lubricants, filters, and consumables necessary for the smooth and reliable operation of the DG set.The scope includes:1.Preventive Maintenance: Execution of all mandatory periodic services (A-Check, B-Check, C-Check,D-Check as per OEM), including replacement of Engine Oil, Coolant, Fuel Filters, Oil Filters, Air Filters, and all associated consumables (The item should be measure and paid seperatly in repective item of this schedule).2.Breakdown Maintenance: Unlimited call-outs for emergency breakdown repairs, including all required labor and consumables.3.Replacement of Parts: Replacement of all non-structural, wear-and-tear components (e.g., fan belts, hoses, sensors, batteries, minor electrical components, etc.) that fail or require replacement during the contract period to ensure operational readiness. Excludes major engine overhaul components (e.g., block, crank, major alternator winding) unless explicitly stated in the contract/tender documents.4.Testing and Load Trials: Quarterly load banking or on-load testing of the DG set for a minimum duration of 1 hour, documenting performance parameters (voltage, frequency, current, oil pressure, temperature).5.Logbook and Reporting: Maintaining a comprehensive service logbook and providing detailed service reports after every PM visit and breakdown call.NOTE:-All work shall be carried out only by authorised Rep of OEM and using all genuine spare parts supplied by OEM only, in this regard an MOU between OEM i.e M/S Cotton Greaves and the Contractor must be perform , A copy of the same MOU shall be uploaded with the tender document . |
| 2 | Appx-A1.Main Power House - 320 KVA2.Trauma Center-320 KVA3.Gynae Department- 40 KVA4.GE Center-200KVA5.ICU Base Hospital-62.5 KVA6.Sur III -200 KVA7.CPL Lab- 160 KVA8.X-Ray Sub- 320 KVA9.OT S/S - 500 KVA10. Pump House-160 KVA11.Ortho-I &II - 200 KVA12.NICU Ward- 160 KVA13.Dialysis Center-62.5 KVA14.Morchary BHDC-50 KVA15.Psy Ward-160 KVA16.Pead Ward-100 KVA17.OT S/S - 160 KVA18.Trauma Center-160 KVA19.COVID ICU- 400 KVA20.NEW OPD -750 KVA |
| 3 | General Terms and Condition For Item no 01(i) All work shall be carried out only by authorised Rep of OEM and using all genuine spare parts supplied by OEM only.(ii) Contractor should be responsible of proper functioning of all the system from current condition (either in malfunctioning or working) in the initial phase of contract and rate for for the same shall be included in the quoted. Nothing extra in that respect shall be paid to the contractor.(iii) Contractor through OEM shall be responsible for repair and replacement of all defective parts of the equipment as per OEM recommendation during entire comprehensive maintenance period.(iii) Preventive maintenance of all systems on monthly basis.(iv) Attending all complaints within 24 working hours intimated by Engg-in-Charge.(v) Field service report shall be maintained and submitted to the Engg-incharge after expiry of every month and before submission of RAR .(vi) The rates quoted by the contractor shall deemed to be inclusive of T&P etc |
| 4 | Supply only Kit fuel filter insert prim & sec cat part no. 123306370785 complete in all aspect all as specified and as directed. |
| 5 | Supply only L.O. filter and element V8/V6 cat part no. 605411880009 complete in all aspect all as specified and as directed. |
| 6 | Supply only air filter element primary 8\\" (XRB08) cat part no. 141109234232 complete in all aspect all as specified and as directed. |
| 7 | Supply only air filter element safety 8\\" (XRB08) cat part no. 141109234233 complete in all aspect all as specified and as directed. |
| 8 | Supply only element-pre-fuel filter cat part no. 1200240911 complete in all aspect all as specified and as directed. |
| 9 | Supply only element-micro-fuel filter cat part no. 1200240912 complete in all aspect all as specified and as directed. |
| 10 | Supply only lube oil filter(232V12) cat part no. 605411880008 complete in all aspect all as specified and as directed. |
| 11 | Supply only pre-filter element cat part no. p21109230191 complete in all aspect all as specified and as directed. |
| 12 | Supply only sec-filter element cat part no. p21109230192 complete in all aspect all as specified and as directed. |
| 13 | Supply only element to air filter (105413100107) cat part no. 105413100166 complete in all aspect all as specified and as directed. |
| 14 | Supply only outer element cat part no. 106900000014 complete in all aspect all as specified and as directed. |
| 15 | Supply only inner element cat part no. 106900000015 complete in all aspect all as specified and as directed. |
| 16 | Supply only outer element cat part no. 106900000045 complete in all aspect all as specified and as directed. |
| 17 | Supply only inner element cat part no. 106900000046 complete in all aspect all as specified and as directed. |
| 18 | Supply only lube oil filter 234 cat part no. 605412970039 complete in all aspect all as specified and as directed. |
| 19 | Supply only primary AF element cat part no. 141109234242 complete in all aspect all as specified and as directed. |
| 20 | Supply only air filter element safety 12\\" (XRB12) cat part no. 141109234243 complete in all aspect all as specified and as directed. |
| 21 | Supply only lube oil filter + element V8/V6 cat part no. 605411880009 complete in all aspect all as specified and as directed. |
| 22 | Supply only Greaves Lube Oil C14+ cat part no 123200198734 complete in all aspect all as specified and as directed. |
| 23 | Supply only Radiator pre-mix greaves kool cat part no 141100195040 complete in all aspect all as specified and as directed. |
| 24 | Supply only coolant additive pack cat part no 123200198518 complete in all aspect all as specified and as directed. |
| 25 | Supply and fix in replacement V-Belt /Drive Belt (Cogged or Plain) as required at site of existing make and size complete all as specified and as directed. |
| 26 | Supply and fix in replacement Battery Terminal Cleaner 250 ml spray cane as required complete as specified and as directed. |
| 27 | Supply and fix in replacement Rocker Cover Gasket/Gasket Set as required at site of existing make and size complete all as specified and as directed. |
| 28 | Supply and fix in replacement Fuel Hose Pipe Set as required at site of existing make and size complete all as specified and as directed. |
| 29 | Supply and fix in replacement O-Ring and seals for oil/fuel lines as required at site of existing make and size complete all as specified and as directed. |
| 30 | Note for item No. 1.03 to 1.281. All item shall be supplied by authorised OEM i.e Greaves Power. |
| 31 | Materials and Labor (M&L) for the dismantling, inspection, replacement of the crankshaft, reassembly, and commissioning of the 320 KVA DG set. This includes the supply of a new crankshaft of suitable size as required at the site, along with main bearings and rod bearings, and a full set of thrust washers for correct crankshaft end float. The work comprises a comprehensive labor charge for the complete dismantling of the engine (including the sump, oil pump, connecting rods, pistons, and cylinder heads), followed by the cleaning of all internal components. The labor also covers the careful reassembly with the new crankshaft, the adjustment of clearances (Main Bearing, Big End, and End Float), and Engine Alignment checks. Furthermore, it requires the replacement of all necessary Engine Gasket Sets, Oil Seals, O-rings, and Packing disturbed during the overhaul, which includes the Sump Gasket, Cylinder Head Gaskets/O-rings, and Front & Rear Crankshaft Seals. The supply also includes Fresh Engine Oil (as per OEM specification and quantity), New Oil Filters, New Fuel Filters, and Coolant/Anti-freeze for the first filling after the rebuild. Finally, the scope covers Commissioning, no-load running, a load test (e.g., for 4 hours at 75% load), and the monitoring of engine parameters (oil pressure, temperature, blow-by, and vibrations) to confirm satisfactory operation as per OEM standards. The work must be complete in all aspects, all as specified and as directed. |
| 32 | Comprehensive rewinding of the 415V, 3-Phase Alternator of any capacity (KVA/KW) required during the contract period of the DG set. The work shall include, but not be limited to, the following tasks and materials, complete in all aspects as specified and directed:Dismantling & Cleaning: Complete dismantling of the Alternator unit, visual inspection, and chemical/steam cleaning of all components (core, housing, rotor, etc.).Winding Removal & Data: Stripping of old, burnt/damaged stator and rotor windings, followed by recording of winding data and slot insulation removal.Stator Rewinding: Installation of New Copper Winding using Electrolytic Grade 99.9% Pure Copper and Enameled High-Temperature Class 'H' or 'F' Insulated Wire. This includes slot insulation, connection of leads, and internal wiring as per the original design.(Supply of Cu wire is measured in the respected item of this schedule.)Rotor/Exciter Work: Inspection and necessary repair or complete rewind of the main rotor field winding and/or Exciter windings using compatible high-grade insulated copper wire.VPI Treatment: Application of High-Grade Insulating Varnish to all new windings, followed by Vacuum Pressure Impregnation (VPI) or an equivalent high-quality impregnation process, and baking to ensure maximum moisture resistance and mechanical stability.Component Replacement: Supply and replacement of New Deep Groove Ball Bearings (e.g., SKF/FAG or equivalent standard) and replacement of all necessary Gaskets, Oil Seals, and Hardware during reassembly.Reassembly & Alignment: Complete reassembly of the alternator unit, mounting back onto the DG set, and execution of necessary alignment checks.Testing & Commissioning: Conduction of pre-commissioning checks including Insulation Resistance (Megger) test and Continuity Check. Final commissioning shall include a Full-Load Test (e.g., for a minimum of 2 hours at 80% load) to confirm stable voltage, frequency, and temperature rise within acceptable limits. |
| 33 | Supply only Electrolytic Grade 99.9% Pure Copper and Enameled High-Temperature Class 'H' or 'F' Insulated Wire in suitable gauge size as required for rewinding of alternator complete in all aspect all as specified and as directed. |
| 34 | Taking down old unsv UG cable complete in all aspect all as specified and as directed. |
| 35 | Supply, laying, jointing and testing of LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts Grade conforming to IS-1554 laid in trenches, pole,road crossing walls, floor etc. cross sectional area of 240 Sqmm 3.5 core complete all as specified and directed. |
| 36 | Supply, laying, jointing and testing of LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts Grade conforming to IS-1554 laid in trenches, pole,road crossing walls, floor etc. cross sectional area of 185 Sqmm 3.5 core complete all as specified and directed. |
| 37 | Supply, laying, jointing and testing of LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts Grade conforming to IS-1554 laid in trenches, pole,road crossing walls, floor etc. cross sectional area of 120 Sqmm 3.5 core complete all as specified and directed. |
| 38 | Supply, laying, jointing and testing of LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts Grade conforming to IS-1554 laid in trenches, pole,road crossing walls, floor etc. cross sectional area of 95 Sqmm 3.5 core complete all as specified and directed. |
| 39 | Supply, laying, jointing and testing of LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts Grade conforming to IS-1554 laid in trenches, pole,road crossing walls, floor etc. cross sectional area of 70 Sqmm 3.5 core complete all as specified and directed. |
| 40 | Supply, laying, jointing and testing of LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts Grade conforming to IS-1554 laid in trenches, pole,road crossing walls, floor etc. cross sectional area of 50 Sqmm 3.5 core complete all as specified and directed. |
| 41 | M&L for of a permanent lighting arrangement for the Diesel Generator (DG) set room/Yard, comprising high-efficiency, industrial-grade IP65-rated LED weatherproof fittings (minimum 36W to 40W) designed to provide an average illumination level of 150–200 Lux across the floor area. The system shall include a dedicated distribution board (DB) with MCB protection, heavy-duty 2.5 sq.mm FRLS (Flame Retardant Low Smoke) copper wiring housed in surface-mounted GI or rigid PVC conduits, and industrial-grade modular switches. The arrangement must feature a standalone emergency lighting unit equipped with an internal battery backup (minimum 2-hour duration) to provide automatic illumination during total power failure, strategically positioned to facilitate safe engine maintenance and control panel operation. All fixtures shall be securely mounted on vibration-resistant brackets to withstand engine-induced resonance, ensuring compliance with local fire safety and electrical regulations for power plant installations with necessary arrangement of UG cable of suitable size jointing to the nearest existing panel with complete excavation and laying in proper way complete in all aspect all as specified and as directed. |
| 42 | M&L for cleaning and sanitization of the designated DG set yard area, including the removal of all accumulated debris, dry leaves, loose soil, and unwanted vegetation or weeds from the flooring and surrounding peripheral drains. The work involves the removal of oil stains, grease, and carbon soot from the floor surface using approved industrial-grade degreasers and high-pressure water jets where applicable, ensuring no water ingress into the DG control panels or sensitive electrical components. It further includes the dusting and wiping of the external acoustic enclosure, radiator fins (using soft brushes/air blowers), and fuel tank exteriors to ensure the area is free from dust and flammable residues. All collected waste must be disposed of at a designated site outside the premises in accordance with environmental safety norms, leaving the entire yard in a neat, orderly, and hazard-free condition complete in all aspect all as specified and as directed. |
| 43 | S&F in replacement 320 kVA AMF Panel with Bypass & Protection Supply and commissioning of a fully automated AMF panel suitable for a 320 kVA DG set. The unit shall be housed in a dust-proof, vermin-proof, IP54-rated metal enclosure. Switchgear shall include a 3-Pole 500A MCCB for DG protection and a pair of 4-Pole AC-3 duty power contactors rated for 500A to handle auto-transfer between Mains and Generator. A key feature includes a 630A 4-Pole On-Load Changeover Switch to provide a complete manual bypass of the AMF logic for maintenance. The Control Logic shall be driven by a microprocessor controller (L&T or equivalent) featuring auto-start/stop, 3-phase sensing, and a digital VAF meter. The panel shall further include an automatic SMPS battery charger (24V), control fuses, phase indicating LEDs, and high-conductivity tinned copper busbars rated for the full load with 35kA fault withstand capacity complete in all aspect all as specified and as directed. |
| 44 | Supply and Fix in replacement MNX 650 3 pole power contractor, 650 Amp AC3/800 Amp AC1 including connection of existing/new LT cable with suitable size of lugs/ferrule complete in all aspect all as specified and as directed. |
| 45 | Supply and Fix in replacement MCX 41 4 pole power contractor, 325 Amp 4 pole including connection of existing/new LT cable with suitable size of lugs/ferrule complete in all aspect all as specified and as directed. |
| 46 | Supply and Fix in replacement MCX 34 4 pole power contractor, 255 Amp 4 pole including connection of existing/new LT cable with suitable size of lugs/ferrule complete in all aspect all as specified and as directed. |
| 47 | Supply and Fix in replacement MNX 250 3 pole power contractor, 250 Amp AC3/300A AC1 pole including connection of existing/new LT cable with suitable size of lugs/ferrule complete in all aspect all as specified and as directed. |
| 48 | Supply and Fix in replacement MCX 47 4 pole power contractor, 800 Amp 2NO+2NC including connection of existing/new LT cable with suitable size of lugs/ferrule complete in all aspect all as specified and as directed. |
| 49 | Supply and Fix in replacement MCX 13 4 pole power contractor, 80 Amp 2NO+2NC including connection of existing/new LT cable with suitable size of lugs/ferrule complete in all aspect all as specified and as directed. |
| 50 | Supply and Fix in replacement C&S power contractor 3 Pole contractor 300 Amp (Model No. LC1FDP330AE) including connection of existing/new LT cable with suitable size of lugs/ferrule complete in all aspect all as specified and as directed. |
| 51 | Supply and Fix in replacement C&S power contractor 3 Pole contractor 315 Amp (Model No. LC1FDP2654AE) including connection of existing/new LT cable with suitable size of lugs/ferrule complete in all aspect all as specified and as directed. |
| 52 | Supply and Fix in replacement C&S power contractor 3 Pole contractor 315 Amp (Model No. LC1FDP2254AE) including connection of existing/new LT cable with suitable size of lugs/ferrule complete in all aspect all as specified and as directed. |
| 53 | Supply and Fix in replacement C&S power contractor 4 Pole contractor 700 Amp (Model No. LC1FDPM5004AE) including connection of existing/new LT cable with suitable size of lugs/ferrule complete in all aspect all as specified and as directed. |
| 54 | Supply and Fix in replacement HRC DIN fuse links HN type size 1 315 A L&T make 100 kA gG fuse SF 94234 comply IS 13703(Part-II) and IEC 60269-2 complete in all aspect all as specified and as directed. |
| 55 | M&L for dismantling and re-installation of the electrical transformer using a mobile crane of suitable capacity, including the disconnection of all primary and secondary terminations, busbars, and grounding strips. The process entails the careful lifting and shifting of the unit from its existing plinth to a designated temporary storage or new location, followed by the precise re-positioning, leveling, and securing of the transformer onto its foundation. All necessary rigging tools, slings, D-shackles, and specialized labor are included to ensure a safe transition, concluding with the re-termination of cables and comprehensive testing to ensure the unit is electrically sound and ready for commissioning complete in all aspect. |
| 56 | Demolition of brick work built in cement mortar including all quoins, pillars etc, complete all as specified and as directed. |
| 57 | M&L brick work with sub class B bricks straight or curved on plan exc 6 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 58 | M & L 15 mm thick rendering in cement mortar (1:4), on brick or concrete wall surface, mixed with water proofing compound @ 2% by weight of cement, finished fair & even without using extra cement complete all as specified and as directed. (Note: WPC shall be measured and separately under relevent item of this Schedule). |
| 59 | Demoiltion of unreinforced cement concrete is ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 60 | M&L for 150 mm thick Plain Cement Concrete (PCC) 1:2:4, Type B1, using 40 mm graded stone aggregate, as in sub-base of foundation, complete all as specified and as directed. |
| 61 | Demolition of RCC of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-charge. |
| 62 | Use and waste form work to sides and soffits of floor, roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, over hangers etc also splays between floor and beam etc for rough finished surfaces of concrete flat complete all as specified and directed by Engr-in-charge. |
| 63 | M&L for MS TMT bar 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire annealed not less than 0.9 mm dia and conforming to Fe 500 or Fe 550D complete all as specified and directed by Engr-in-charge. |
| 64 | M&L for MS TMT bar 8 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire annealed not less than 0.9 mm dia and conforming to Fe 500 or Fe 550D complete all as specified and directed by Engr-in-charge. |
| 65 | M&L for Reinforced cement concrete (1:2:4) (Nominal Mix) Type B1 using 20mm graded stone aggregate slabs supported on walls, beams, and columns, in floors, roof, landings, balconies, canopies, deck slab and in shelves and the like complete all as specified and directed by Engr-in-charge. |
| 66 | M&L Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by Engr-in-charge. |
| 67 | Supply and fix in replacement 800A, 3-Pole (3P) Moulded Case Circuit Breaker (MCCB) having a rated short-circuit breaking capacity of 36kA at 415V AC. The unit shall feature a microprocessor-based or thermal-magnetic adjustable trip release for overload and short-circuit protection, complete with rotary operating handle (ROM), phase separators, and necessary terminal spreaders for cable termination complete in all aspect all as specified and as directed. |
| 68 | Supply and fix in replacement 800A, 4-Pole (4P) Moulded Case Circuit Breaker (MCCB) having a rated short-circuit breaking capacity of 36kA at 415V AC. The unit shall feature a microprocessor-based or thermal-magnetic adjustable trip release for overload and short-circuit protection, complete with rotary operating handle (ROM), phase separators, and necessary terminal spreaders for cable termination complete in all aspect all as specified and as directed. |
| 69 | Supply and installation in replacement of 800A, 4-Pole (4P), Manual On-Load Changeover Switch (I-O-II) in open execution for panel mounting. The switch shall be rated for AC-23A utilization category at 415V, conforming to IS/IEC 60947-3, with a rated insulation voltage of 1000V. It shall feature a robust double-break contact system, high-grade flame-retardant housing, and a door-interlocked extended rotary operating handle. The scope includes providing tinned copper bridging bars, terminal shrouds, and all necessary hardware for integration into the AMF panel busbar system complete in all aspect all as specified and as directed. |
| 70 | Supply and fix in replacement 630A, 3-Pole (3P) Moulded Case Circuit Breaker (MCCB) having a rated short-circuit breaking capacity of 36kA at 415V AC. The unit shall feature a microprocessor-based or thermal-magnetic adjustable trip release for overload and short-circuit protection, complete with rotary operating handle (ROM), phase separators, and necessary terminal spreaders for cable termination complete in all aspect all as specified and as directed. |
| 71 | Supply and fix in replacement 630A, 4-Pole (4P) Moulded Case Circuit Breaker (MCCB) having a rated short-circuit breaking capacity of 36kA at 415V AC. The unit shall feature a microprocessor-based or thermal-magnetic adjustable trip release for overload and short-circuit protection, complete with rotary operating handle (ROM), phase separators, and necessary terminal spreaders for cable termination complete in all aspect all as specified and as directed. |
| 72 | Supply and installation in replacement of 630A, 4-Pole (4P), Manual On-Load Changeover Switch (I-O-II) in open execution for panel mounting. The switch shall be rated for AC-23A utilization category at 415V, conforming to IS/IEC 60947-3, with a rated insulation voltage of 1000V. It shall feature a robust double-break contact system, high-grade flame-retardant housing, and a door-interlocked extended rotary operating handle. The scope includes providing tinned copper bridging bars, terminal shrouds, and all necessary hardware for integration into the AMF panel busbar system complete in all aspect all as specified and as directed. |
| 73 | Supply and fix in replacement 500A, 3-Pole (3P) Moulded Case Circuit Breaker (MCCB) having a rated short-circuit breaking capacity of 36kA at 415V AC. The unit shall feature a microprocessor-based or thermal-magnetic adjustable trip release for overload and short-circuit protection, complete with rotary operating handle (ROM), phase separators, and necessary terminal spreaders for cable termination complete in all aspect all as specified and as directed. |
| 74 | Supply and fix in replacement 500A, 4-Pole (4P) Moulded Case Circuit Breaker (MCCB) having a rated short-circuit breaking capacity of 36kA at 415V AC. The unit shall feature a microprocessor-based or thermal-magnetic adjustable trip release for overload and short-circuit protection, complete with rotary operating handle (ROM), phase separators, and necessary terminal spreaders for cable termination complete in all aspect all as specified and as directed. |
| 75 | Supply and installation in replacement of 500A, 4-Pole (4P), Manual On-Load Changeover Switch (I-O-II) in open execution for panel mounting. The switch shall be rated for AC-23A utilization category at 415V, conforming to IS/IEC 60947-3, with a rated insulation voltage of 1000V. It shall feature a robust double-break contact system, high-grade flame-retardant housing, and a door-interlocked extended rotary operating handle. The scope includes providing tinned copper bridging bars, terminal shrouds, and all necessary hardware for integration into the AMF panel busbar system complete in all aspect all as specified and as directed. |
| 76 | Supply and fix in replacement 320A, 3-Pole (3P) Moulded Case Circuit Breaker (MCCB) having a rated short-circuit breaking capacity of 36kA at 415V AC. The unit shall feature a microprocessor-based or thermal-magnetic adjustable trip release for overload and short-circuit protection, complete with rotary operating handle (ROM), phase separators, and necessary terminal spreaders for cable termination complete in all aspect all as specified and as directed. |
| 77 | Supply and fix in replacement 320A, 4-Pole (4P) Moulded Case Circuit Breaker (MCCB) having a rated short-circuit breaking capacity of 36kA at 415V AC. The unit shall feature a microprocessor-based or thermal-magnetic adjustable trip release for overload and short-circuit protection, complete with rotary operating handle (ROM), phase separators, and necessary terminal spreaders for cable termination complete in all aspect all as specified and as directed. |
| 78 | Supply and installation in replacement of 320A, 4-Pole (4P), Manual On-Load Changeover Switch (I-O-II) in open execution for panel mounting. The switch shall be rated for AC-23A utilization category at 415V, conforming to IS/IEC 60947-3, with a rated insulation voltage of 1000V. It shall feature a robust double-break contact system, high-grade flame-retardant housing, and a door-interlocked extended rotary operating handle. The scope includes providing tinned copper bridging bars, terminal shrouds, and all necessary hardware for integration into the AMF panel busbar system complete in all aspect all as specified and as directed. |
| 79 | Supply and fix in replacement 250A, 3-Pole (3P) Moulded Case Circuit Breaker (MCCB) having a rated short-circuit breaking capacity of 36kA at 415V AC. The unit shall feature a microprocessor-based or thermal-magnetic adjustable trip release for overload and short-circuit protection, complete with rotary operating handle (ROM), phase separators, and necessary terminal spreaders for cable termination complete in all aspect all as specified and as directed. |
| 80 | Supply and fix in replacement 250A, 4-Pole (4P) Moulded Case Circuit Breaker (MCCB) having a rated short-circuit breaking capacity of 36kA at 415V AC. The unit shall feature a microprocessor-based or thermal-magnetic adjustable trip release for overload and short-circuit protection, complete with rotary operating handle (ROM), phase separators, and necessary terminal spreaders for cable termination complete in all aspect all as specified and as directed. |
| 81 | Supply and installation in replacement of 250A, 4-Pole (4P), Manual On-Load Changeover Switch (I-O-II) in open execution for panel mounting. The switch shall be rated for AC-23A utilization category at 415V, conforming to IS/IEC 60947-3, with a rated insulation voltage of 1000V. It shall feature a robust double-break contact system, high-grade flame-retardant housing, and a door-interlocked extended rotary operating handle. The scope includes providing tinned copper bridging bars, terminal shrouds, and all necessary hardware for integration into the AMF panel busbar system complete in all aspect all as specified and as directed. |
| 82 | Supply, installation, testing, and commissioning in replacement of a 100 Amp, 4-Pole, motorized Automatic Transfer Switch (ATS) conforming to IEC 60947-6-1 standards, designed for seamless power transition between primary (Utility) and secondary (Generator) power sources. The unit shall feature a high-speed switching mechanism with a transfer time of less than 500 ms, integrated mechanical and electrical interlocks to prevent simultaneous connection of both sources, and a microprocessor-based controller for real-time voltage and frequency monitoring of both inputs. The ATS shall include adjustable time delays for source failure (0–60s) and restoration (0–30 mins), an integrated manual operating handle for emergency use, and a user-friendly HMI or LED status panel indicating source availability and \\"On-Load\\" status. The assembly must be housed in a compact IP54 rated enclosure suitable for DIN rail or plate mounting, providing short-circuit making capacity of at least 15 kA and auxiliary contacts for remote signaling and generator start/stop control complete in all aspect all as specified and as directed. |
| 83 | Supply, installation, testing, and commissioning of a 200 Amp, 4-Pole, motorized Automatic Transfer Switch (ATS) conforming to IEC 60947-6-1 (Utilization Category AC-33B/AC-32B), specifically designed for high-reliability power transition between Utility and Standby Generator sources. The unit shall be a Class PC/CC transfer switch featuring a robust solenoid or motorized switching mechanism with a rapid transfer time (typically <500ms) and an integrated microprocessor-based controller for continuous three-phase monitoring of voltage, frequency, and phase sequence on both sources. The assembly must incorporate a patented mechanical and electrical interlocking system to prevent simultaneous connection of sources, alongside a user-interface featuring an LCD/LED display for status annunciation, adjustable time delays for engine start (TDES), transfer (TDNE), and cool-down (TDEC), and a manual emergency override handle. Housed in a compact, IP40/IP54 rated enclosure, the switch shall provide a rated short-time withstand current of at least 10 kA (0.5s), auxiliary contacts for remote signaling/BMS integration, and terminal shrouds for safe cable termination of up to 150 sq.mm conductors complete in all aspect all as specified and as directed. |
| 84 | Supply, installation, testing, and commissioning of a 400 Amp, 4-Pole, motorized Automatic Transfer Switch (ATS) conforming to IEC 60947-6-1 (Utilization Category AC-33B/AC-32B) for high-capacity industrial or commercial backup power systems. The unit shall be a Class PC transfer switch featuring a motorized or high-speed solenoid switching mechanism with a transition time typically less than 500 ms and three stable positions (I-O-II) to ensure a \\"break-before-make\\" sequence. It must include an integrated microprocessor controller for real-time monitoring of three-phase voltage and frequency on both sources, with adjustable parameters for under/over voltage, phase loss, and frequency deviation. The assembly shall incorporate a robust mechanical and electrical interlocking system, a front-facing LCD or LED display for status indication and alarm logging, and manual emergency operating facilities. Housed in a powder-coated, IP40/IP54 rated enclosure, the switch must have a rated short-time withstand current of at least 20 kA (0.5s), a short-circuit making capacity of at least 40 kA, and provide auxiliary contacts for generator start/stop control and remote BMS signaling via RS485/Modbus communication complete in all aspect all as specified and as directed. |
| 85 | M&L for locating the fault in underground electrical power cable of any length & any type of 1100 volt grade LT cables, by arranging portable fault locating Machine suitable for underground LT power cable faulty detection ,including pre -location and pin point capability using TDR or similer advance technology the fault, cutting the cable at fault to fixing the joint including testing of the cable after locating fault and jointing cable including excavation and earth work in any type of soil complete all as specified and as directed. Note:- (i) Jointing of cable shall be measured and paid separately under respective item of this Schedule. (ii) If fault is not rectified within 24 hours after receiving Message, the contractor shall be charged penalty for Rs 500/- per hour per complaint and shall be deducted from next payment due to contractor. |
| 86 | S&F straight through jointing kit for 1.1 kv XLPE/PVC insulated cable size 10sqmm- 25sqmm including all accessories such as lugs/ferrule,heat shrink sleeve,insulated tape, sealing compounds, mechanical and electrical protection as per manufacturer recommendation includes prepration of cable end,crimping of connectors,cleaning, application of anti corrosion compond complete in all aspect all as specified and as directed. |
| 87 | All as per item No 57 above here in before but cable size 35sqmm-50sqmm. |
| 88 | All as per item No 57 above here in before but cable size 70sqmm-95sqmm. |
| 89 | All as per item No 57 above here in before but cable size 120sqmm-240sqmm. |
| 90 | All as per item No 57 above here in before but cable size 300sqmm-630sqmm. |
| 91 | Supply,Installtion and termination of high conductivity electro-thinned copper compression lugs suitable for cable size 10 sqmm-25sqmm stranderd cable M-6/M-8/M-10/M-12 stud hole size, with inspection hole to comply IS 8309 standerd complete in all aspect all as specified and directed. |
| 92 | All as per item No 62 above here in before but cable size 35sqmm-50sqmm. |
| 93 | All as per item No 62 above here in before but cable size 70sqmm-95sqmm. |
| 94 | All as per item No 62 above here in before but cable size 120sqmm-150sqmm. |
| 95 | All as per item No 62 above here in before but cable size 185sqmm. |
| 96 | All as per item No 62 above here in before but cable size 200sqmm-240sqmm. |
| 97 | All as per above item No 62 here in before but cable size 300sqmm-400sqmm. |
| 98 | All as per above item No 62 here in before but cable size 500sqmm-630sqmm. |
| 99 | Supply, installation, testing, and commissioning in replacement of new Lead Acid Battery as required at site with a capacity of 120 Ampere-Hour (AH) at the 12 Volt capacity. The battery must comply with relevant standards 1651, IEC 60896 and include the following as a complete in all aspect all as specified and directed. |
| 100 | Supply & fixing in Replacement Sealed Maintenance Free 12V/65AH Batteries with suitable size terminal link complete in all aspect all as specified and a directed. |
| 101 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts, checknuts and washers of galvanized iron or steel as shown in electrical plate No 3 connected to earthing test point including testing on completion all as directed.Note:- The unit rate quoted shall be include for necessary excavation and earth work , earth strip connected to test point max 7 mtr as per site requirement, PCC 1:3:6 type for earth pit & Pit cover, funnel with wire mesh including GI medium grade watering pipe 15mm bore & 25 mm dia for supporting of earth strip/wire. |
| 102 | Material and Labor for complete comprehensive maintenance of Passenger Lift of 2000 Kg capacity through OEM (i.e M/S TK Elevators) including unlimited breakdown/call-out services, and replacement of all consumables and wear-and-tear parts ensuring reliable and safe operation of the lift installed at Adm Block including Execution of periodic checks on monthly basis as per OEM specifications, covering inspection, lubrication, adjustments, cleaning, and testing of all major components,unlimited emergency call-out services and breakdown maintenance within the response time specified in the contract,repair/replacement of parts that fail during normal operation complete in all as aspect all as specified and as directed.The work also includes but not limited to:-1.Replacement of main hoist ropes and governor ropes2.Replacement of Contactors, Relays, PCB/Card repairs (excluding complete main Controller replacement), Limit Switches, and Fuses.3.Replacement of Car Guide Shoes, Counter Weight Guide Shoes, Bearings, Oil Seals, and all necessary Lubricants/Grease.4.Replacement of Door Locks/Contacts, Door Operator Parts (excluding complete machine), Landing/Car Push Buttons, Indicators, and Cabin Lighting5.Regular testing of safety features (Overspeed Governor, Safety Gear, Buffers, Limit Switches) and providing necessary documentation for regulatory compliance |
| 103 | Material and Labor for complete comprehensive maintenance of Goods Lift of 1000 Kg capacity through OEM (i.e M/S TK Elevators) including unlimited breakdown/call-out services, and replacement of all consumables and wear-and-tear parts ensuring reliable and safe operation of the lift installed at Adm Block including Execution of periodic checks on monthly basis as per OEM specifications, covering inspection, lubrication, adjustments, cleaning, and testing of all major components,unlimited emergency call-out services and breakdown maintenance within the response time specified in the contract,repair/replacement of parts that fail during normal operation complete in all as aspect all as specified and as directed.The work also includes but not limited to:-1.Replacement of main hoist ropes and governor ropes2.Replacement of Contactors, Relays, PCB/Card repairs (excluding complete main Controller replacement), Limit Switches, and Fuses.3.Replacement of Car Guide Shoes, Counter Weight Guide Shoes, Bearings, Oil Seals, and all necessary Lubricants/Grease.4.Replacement of Door Locks/Contacts, Door Operator Parts (excluding complete machine), Landing/Car Push Buttons, Indicators, and Cabin Lighting5.Regular testing of safety features (Overspeed Governor, Safety Gear, Buffers, Limit Switches) and providing necessary documentation for regulatory compliance |
| 104 | General Terms and Condition for item no ( & ) :-(i) All work shall be carried out only by authorised Rep of OEM and using all genuine spare parts supplied by OEM only, in this regard an MOU between OEM i.e M/S TK Elevators and the Contractor must be perform , A copy of the same MOU shall be uploaded with the tender document .(ii) Contractor should be responsible of proper functioning of all the system from current condition (either in malfunctioning or working) in the initial phase of contract and rate for for the same shall be included in the quoted. Nothing extra in that respect shall be paid to the contractor.(iii) Contractor through OEM shall be responsible for repair and replacement of all defective parts of the equipment as per OEM recommendation during entire comprehensive maintenance period.(iii) Preventive maintenance of all systems on monthly basis.(iv) Attending all complaints within 24 working hours intimated by Engg-in-Charge.(v) Field service report shall be maintained and submitted to the Engg-incharge after expiry of every month and before submission of RAR .(vi) The rates quoted by the contractor shall deemed to be inclusive of T&P etc |
| 105 | Supply, installation, testing, and commissioning in replacement of a fully automatic, three-phase, microprocessor-based Phase Sequence Corrector unit, suitable for operation on a 50 Hz AC supply system with IP 4X protection for rated current capacity of 100 Amp,415 Volt 3-Phase, 4-Wire, Fast switching time, typically < 1 second , Microprocessor controlled using Thyristorised or Contactor-based switching ,Digital display for line-to-line/line-to-neutral voltages and phase sequence status (R-Y-B/R-B-Y) with Built-in protection against over-voltage, under-voltage, and single-phasing and Manual or Automatic bypass arrangement (Contactor/Switch-based) , suitbale size of incoming and outgoing power cables between the main distribution board/source and the APSC unit, including termination with lugs, glands, and ferrule marking complete with necessary mounting hardware (MS channel supports, bolts, etc.) for fixing the unit securely at the designated location in all aspect as specified and directed. Please Enable Macros to View BoQ information |
| 106 | Supply, installation, testing, and commissioning in replacement of a fully automatic, three-phase, microprocessor-based Phase Sequence Corrector unit, suitable for operation on a 50 Hz AC supply system with IP 4X protection for rated current capacity of 100 Amp,415 Volt 3-Phase, 4-Wire, Fast switching time, typically < 1 second , Microprocessor controlled using Thyristorised or Contactor-based switching ,Digital display for line-to-line/line-to-neutral voltages and phase sequence status (R-Y-B/R-B-Y) with Built-in protection against over-voltage, under-voltage, and single-phasing and Manual or Automatic bypass arrangement (Contactor/Switch-based) , suitbale size of incoming and outgoing power cables between the main distribution board/source and the APSC unit, including termination with lugs, glands, and ferrule marking complete with necessary mounting hardware (MS channel supports, bolts, etc.) for fixing the unit securely at the designated location in all aspect as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy