| 1 | Material and labour for taking down the old ceiling fan of any make and Supply and fixing connecting & testing of ceiling fan complete with blades, down rods, fan regulator socket type and accesssories, 230V , 1200mm sweep , Min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) without reomte complete all as directed. Notes:- (a) Old taking down ceiling fan shall be deposited to E/M-II store yard.(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a \\"Pre dispatch\\" inspection at the \\"Factory Premises\\" shall be carried out by the Engineer-in-Charge alongwuth the representative of \\"Accepting Officer\\" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The \\"Pre dispatch\\" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. |
| 2 | Material and labour for taking down the old ceiling fan of any make and Supply and fixing connecting & testing of ceiling fan complete with blades, down rods, fan regulator socket type and accesssories, 230V , 1400 sweep , Min air delivery 245 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) without reomte complete all as directed. Notes:- (a) Old taking down ceiling fan shall be deposited to E/M-II store yard.(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a \\"Pre dispatch\\" inspection at the \\"Factory Premises\\" shall be carried out by the Engineer-in-Charge alongwuth the representative of \\"Accepting Officer\\" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The \\"Pre dispatch\\" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. |
| 3 | Material and labour for taking down the old exhaust fan of any make and Supply and fixing exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge. Notes:- Old taking down exhaust fan shall be deposited to E/M-II store yard.(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a \\"Pre dispatch\\" inspection at the \\"Factory Premises\\" shall be carried out by the Engineer-in-Charge alongwuth the representative of \\"Accepting Officer\\" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The \\"Pre dispatch\\" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. |
| 4 | Material and labour for taking down the old exhaust fan of any make and Supply and fixing exhaust fan 450 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge. Notes:- Old taking down exhaust fan shall be deposited to E/M-II store yard.(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a \\"Pre dispatch\\" inspection at the \\"Factory Premises\\" shall be carried out by the Engineer-in-Charge alongwuth the representative of \\"Accepting Officer\\" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The \\"Pre dispatch\\" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. |
| 5 | Material and labour for taking down the old split type unit of any make and capcity and Supply and fixing connecting & testing of air cooled split unit indoor & outdoor complete with cordless remote control unit air conditioner electric driven,single phase 230V, 50 hz, turbo cooling, inverter type of capacity of 1.5 TR, BEE 5 star rated inverter split AC with anti dust filter, copper condensor, R-32 refrigerant,Environment friendly- no ozone depletion potential & low global warming potential with & including suitable MS mounting stands for indoor and outdoor unit including connecting Cu cable and connecting copper pipe up to 5 mtr length, drain pipe, energy efficient, high ambient cooling, anti microbial air filtration, self dignosis, LED Display and Completed all as specified and directed. NOTES : (a). The rates quoted shall deem to include the cost of cutting holes in the brick wall for passing copper tubing and making good the surfcaes to match with adjoining surfaces include fixing with angle iron into any type of wall for out door unit whereever reqd.(b). Old taking down split AC shall be deposited to E/M-II store yard.(c) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a \\"Pre dispatch\\" inspection at the \\"Factory Premises\\" shall be carried out by the Engineer-in-Charge alongwuth the representative of \\"Accepting Officer\\" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The \\"Pre dispatch\\" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. |
| 6 | Material and labour for taking down the old split type unit of any make and capcity and Supply and fixing connecting & testing of air cooled split unit indoor & outdoor complete with cordless remote control unit air conditioner electric driven,single phase 230V, 50 hz, turbo cooling, inverter type of capacity of 2.0 TR, BEE 5 star rated inverter split AC with anti dust filter, copper condensor, R-32 refrigerant,Environment friendly- no ozone depletion potential & low global warming potential with & including suitable MS mounting stands for indoor and outdoor unit including connecting Cu cable and connecting copper pipe up to 5 mtr length, drain pipe, energy efficient, high ambient cooling, anti microbial air filtration, self dignosis, LED Display and Completed all as specified and directed. NOTES : (a). The rates quoted shall deem to include the cost of cutting holes in the brick wall for passing copper tubing and making good the surfcaes to match with adjoining surfaces include fixing with angle iron into any type of wall for out door unit whereever reqd.(b). Old taking down split AC shall be deposited to E/M-II store yard.(c) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a \\"Pre dispatch\\" inspection at the \\"Factory Premises\\" shall be carried out by the Engineer-in-Charge alongwuth the representative of \\"Accepting Officer\\" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The \\"Pre dispatch\\" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. |
| 7 | Material and labour for dismantling the old split type unit of any make and capcity and Supply and fix connecting / testing of air cooled split unit indoor/outdoor complete with cordless remote control unit air conditioner electric driven,three phase 415V, 50 hz of capacity 3 TR, BEE Star rating, copper condensor,Refrigerant R-32 / R-410A (Eco-friendly, non-ozone depleting),MS mounting stands for indoor and outdoor unit includig connecting Cu cable and connecting copper pipe up to 5 mtr length, drain pipe,energy efficient, high ambient cooling , anti microbial air filtration, self dignosis,LED Display and Completed all as specified and direted. NOTES : (a). The rates quoted shall deem to include the cost of cutting holes in the brick wall for passing copper tubing and making good the surfcaes to match with adjoining surfaces include fixing with angle iron into any type of wall for out door unit whereever reqd.(b). Old taking down split AC shall be deposited to E/M-II store yard.(c) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a \\"Pre dispatch\\" inspection at the \\"Factory Premises\\" shall be carried out by the Engineer-in-Charge alongwuth the representative of \\"Accepting Officer\\" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The \\"Pre dispatch\\" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. |
| 8 | Material and labour for taking down the old window AC unit of any make and capcity and Supply and fix connecting & testing of heav duty window type air conditioner with cordless remote control unit,Cooling Capacity Full Load 5100W, Cooling Capacity Half Load 2550W inverter type,single phase 230V, 50 hz of capacity of 1.5TR, copper condensor coil, R-32 Eco Friendly Refrigerant,Turbo Cooling, LED Display, energy efficient, BEE 5 star rated Completed all as specified and direted.Notes:- (a) Old taking down window AC shall be deposited to E/M-II store yard.(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a \\"Pre dispatch\\" inspection at the \\"Factory Premises\\" shall be carried out by the Engineer-in-Charge alongwuth the representative of \\"Accepting Officer\\" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The \\"Pre dispatch\\" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. |
| 9 | Material and labour for taking down the old refrigerator of any make and capcity and Supply and fixing connecting & testing of refrigerator, electric driven single phase 230V, 50 hz, single door, capacity not less than 185 Litres or nearest higher capacity . BEE star rated Completed all as specified and direted.Notes:- (a) Old taking down refregerator shall be deposited to E/M-II store yard.(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a \\"Pre dispatch\\" inspection at the \\"Factory Premises\\" shall be carried out by the Engineer-in-Charge alongwuth the representative of \\"Accepting Officer\\" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The \\"Pre dispatch\\" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. |
| 10 | Material and labour for dismantling the old desert cooler of any make and capcity and Supply and fix connecting / testing of desert cooler electric driven single phase230V, 50 hz, having nominal Air Delivery 4000 CFM ±5% ,window type, with copper wound exhaust fan (metal blades) Motor Speed 1350–1450 RPM, Fan Diameter 18\\" to 20\\" (450–500 mm),Power Consumption 400–600 W (approx.),Heavy gauge galvanized steel body including honey compo pads,Water Tank Capacity 60–80 liters Dimension (Approx.) 700 mm × 650 mm × 950 mm (L×W×H),Overhead water distributor with plastic piping Pump Type Submersible water pump18–25 W Completed all as specified and direted.Notes:- (a) Old taking down desert coolers shall be deposited to E/M-II store yard.(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a \\"Pre dispatch\\" inspection at the \\"Factory Premises\\" shall be carried out by the Engineer-in-Charge alongwuth the representative of \\"Accepting Officer\\" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The \\"Pre dispatch\\" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. |
| 11 | Material and labour for sub main wiring (concealed) with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 4 sqmm drawn through and including non - metallic rigid PVC conduits of suitable size with all necessary fittings and provision of one run of 4 sqmm PVC insulated unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, complete all as specified and directed.Note: Two runs of 4 sqmm cable, one run of 4 sqmm earth conductor cable and one run of PVC conduits shall be measured and paid together as one unit length. |
| 12 | Supply and fixing metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket with and inlcuding one SP MCB 20 Amps, 10kA complete all as specified and as directed. |
| 13 | Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 25 mm dia with accessories, on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including 3mm thick laminated sheet over sunken box for housing the switches , socket outlets, fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) Switch, socket outlet and fan regulators to be measured and paid for separately . |
| 14 | All as item No.13.00 here-in-before but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board. |
| 15 | Supply and fixing switch piano, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Supply and fixing switch piano, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 17 | Supply and fixing socket outlet 2 in 1, 6 & 16 Amp, one way, 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 18 | Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Material and labour for sub main wiring (concealed) with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 6 sqmm drawn through and including non - metallic rigid PVC conduits of suitable size with all necessary fittings and provision of one run of 6 sqmm PVC insulated unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, complete all as specified and directed.Note: Two runs of 6 sqmm cable, one run of 6 sqmm earth conductor cable and one run of PVC conduits shall be measured and paid together as one unit length. |
| 20 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised iron wire earth lead of 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron, earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion . |
| 21 | Supply and fixing exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge. Note : The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a \\"Pre dispatch\\" inspection at the \\"Factory Premises\\" shall be carried out by the Engineer-in-Charge alongwuth the representative of \\"Accepting Officer\\" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The \\"Pre dispatch\\" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. |
| 22 | Supplying, laying, jointing, testing & commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoured electric power cable with stranded aluminium conductor of cross sectional area 16 Sqmm 2 core conforming to IS- 7098 (Part-I) 1988 laid as in trenches or fixed along the wall/pole through pipe etc. complete all as specified & directed.Note : The above LT cables may be procured either directly from the manufacturer or their authorised dealers. In both cases, a \\"Pre dispatch\\" inspection at the \\"Factory Premises\\" shall be carried out by the Engineer-in-Charge alongwuth the representative of \\"Accepting Officer\\" to verify the major sepifications and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The \\"Pre dispatch\\" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. |
| 23 | Excavation in trenches, not exceeding 1.5mtr wide & not exceeding 1.5mtr in depth; for foundation, laying/taking out pipes/cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan & not exceeding 1.5mtr in depth and getting out, in soft/loose type soil complete all as specified & directed. |
| 24 | All as per Item No. 23 above but for depth exceeding 1.50 m and not exceeding 3.00 m complete all as specified and directed.. |
| 25 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm thick each in soft/loose type soil complete all as specified & directed. |
| 26 | Removal of excavated surplus soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed. |
| 27 | Material and labour sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cm deep after laying the cable (punned down to 18 cm depth after laying and stretching of cable ) complete all as specified & directed. |
| 28 | Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge |
| 29 | S&F GI tubing 40 mm bore light grade galvanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position including taking down existing one complete all as specified. |
| 30 | Supply and fixing sheet metal enclosures 4 way TPN Vertiacal type loadline distribution board of 4 way incomer + 12 module outgoings , double door IP 43 protection 160 A rated bus bar blanking plates duly flush in wall and making good disturbed surfaces complete all as specified and directed . |
| 31 | Supply and fixing sheet metal enclosures for MCB distribution board 415 Volts three pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. |
| 32 | Supply and fixing sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. |
| 33 | Supply and fixing MCCB three pole 415 Volts, 100 A, 16 KA complete all as specified and directed. |
| 34 | Supply and fixing MCB three pole and neutral 415 Volts, 40 A, 10 KA complete all as specified and directed. |
| 35 | Supply and fixing MCBs 5 to 40 amp SPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed. |
| 36 | Supply and fixing MCB, 5 to 32 amp SP C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed. |
| 37 | Supply and fixing true vertical steel tubular, swaged welded pole conforming to 1S-2713 part II, type 410 SP 31, 9 metre long complete with mild steel base plate of 6mm thick size 300mm X 300mm, finial taper plug, cap, boltes, nuts, washer and screws hole of required size and Nos. for fixing cross arms including painting externally with two coats of aluminium paint over & including one coat of zinc oxide primer for exposed surface and two coats of black bluminious paint for embeded portion in concrete as well as throughout internally including provision of white & blue colour strips with fluorescent paint upto 1.5 mtr height & numbering of pole complete all as specified & directed.Note Excavation, earth work and PCC shall be measured and paid separately. |
| 38 | Supply instaliation, commissioning and testing LT panel of AC, 3 phase, 415 volts, 50 Hz out door type control panel factory made approx size 600x600x300mm free standing dust proof, vermin and water proof tecna modular fully bolted with concealed hinges for all doors & PU foam gasket at doors, fabricated cut of 3.15 mm thick CRCA sheet inciduing aluminium bus bar 200 Amps with front & backside door and locking arrangement, degree of protection-54. The metal will be treated in ten tank process. After thorough treatment, the panel will be epoxy powder coated, painted with standard and including volt meter, amp meter, indicator lamps, selector switches Fully compartmentalized designed with MCCB 100 Amp, 36 KA 4 pole 415 volts with adjustable thermal magnetic release Inspection at factory premises IP-54 certificate of CPRI also required angle iron stand of size 40x40x6mm frame grouted in ground with PCC foundation 1:2:4 type C1 with 20mm graded mechanically crushed stone aggregate along with all necesary cable connections, lugs and cable gland including 2 coat of paint over a coat of red oxide primer complete all as specified and directed |
| 39 | Supply and fixing of LED street light fittings 120 watts, input 120 volts to 280 volts volts, life > 25000 Hrs, color temperature 5700K, initial efiicacy>= 100 Im/watt IP 66, high pressure Die cast aluminium housing with weather proof gasket for lamp the driver must be constant current type having power factor > 0.90 with short circuit protection, open circuit protection, reverse circuit protection, high voltage protection, protection against 5 KV high surges, necessary connection with multi standard copper conductor cable 3 core 1.0 sqmm for connection complete all as speecified and directed. |
| 40 | Supply and fixing of LED street light fittings 90 watts, input 120 volts to 280 volts volts, life > 25000 Hrs, color temperature 5700K, initial efiicacy>= 100 Im/watt IP 66, high pressure Die cast aluminium housing with weather proof gasket for lamp the driver must be constant current type having power factor > 0.90 with short circuit protection, open circuit protection, reverse circuit protection, high voltage protection, protection against 5 KV high surges, necessary connection with multi standard copper conductor cable 3 core 1.0 sqmm for connection complete all as speecified and directed. |
| 41 | Supply and fixing of LED street light fittings 72 watts, input 120 volts to 280 volts volts, life > 25000 Hrs, color temperature 5700K, initial efiicacy>= 100 Im/watt IP 66, high pressure Die cast aluminium housing with weather proof gasket for lamp the driver must be constant current type having power factor > 0.90 with short circuit protection, open circuit protection, reverse circuit protection, high voltage protection, protection against 5 KV high surges, necessary connection with multi standard copper conductor cable 3 core 1.0 sqmm for connection complete all as speecified and directed. |
| 42 | Supply and fixing LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed |
| 43 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed |
| 44 | Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed |
| 45 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed |
| 46 | Supply and fixing 10 KW equally distributed over 3 phase (3 KW/Phase) automatic street light switch using Nature Switch for automatic switching of street light based on LUX level of natural light. The infrared sensor based on nature switch along with Contactor 63 Amp per phase, MCB SP for input and out put 32 amp wiring for main load 16 sqmm copper should be enclosed in pole/wall mounted enclosure made out of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP 54 all as specified and directed |
| 47 | Supply and fixing security light bracket made out from Gl pipe light grade of size 32/40mm dia bent to shape having length 1.2 meter including flat iron clamp made of FI 40x6mm nuts, bolts, washers etc duly painted with two coat of synthetic enamel paint over a coat of red oxide primer all as specified and directed. |
| 48 | Supplying, laying, jointing, testing & commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoured electric power cable with stranded aluminium conductor of cross sectional area 25 Sqmm 4 core conforming to IS- 7098 (Part-I) 1988 laid as in trenches or fixed along the wall/pole through pipe etc. including taking down/out old unserviceable LT cable any size complete all as specified & directed. |
| 49 | Supplying, laying, jointing, testing & commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoured electric power cable with stranded aluminium conductor of cross sectional area 16 Sqmm 4 core conforming to IS- 7098 (Part-I) 1988 laid as in trenches or fixed along the wall/pole through pipe etc. complete all as specified & directed. |
| 50 | Supplying, laying, jointing, testing & commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoured electric power cable with stranded aluminium conductor of cross sectional area 10 Sqmm 4 core conforming to IS- 7098 (Part-I) 1988 laid as in trenches or fixed along the wall/pole through pipe etc. complete all as specified & directed. |
| 51 | Supplying, laying, jointing, testing & commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoured electric power cable with stranded aluminium conductor of cross sectional area 10 Sqmm 2 core conforming to IS- 7098 (Part-I) 1988 laid as in trenches or fixed along the wall/pole through pipe etc. complete all as specified & directed.Notes for item Nos.48.00 to 51.00 : The above LT cables may be procured either directly from the manufacturer or their authorised dealers. In both cases, a \\"Pre dispatch\\" inspection at the \\"Factory Premises\\" shall be carried out by the Engineer-in-Charge alongwuth the representative of \\"Accepting Officer\\" to verify the major sepifications and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The \\"Pre dispatch\\" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. |
| 52 | Material and labour for cement concrete 1:3:6 type C-2 using (40 mm graded mechanically crushed stone aggregate) in foundation filling of poles/stays/plinths etc complete all as specified and directed |
| 53 | Material and labour for cement concrete 1:2:4 type B-1 using (20 mm graded mechanically crushed stone aggregate) in coping of poles including form work whereas required as per site requirement complete all as specified and directed |
| 54 | Supply and fixing junction box thermoplastic polycarbonate enclosure, shock proof, IP65/IP66 (weather, rust, dust, water and vibration proof, outdoor type, internally embedded gasket with provision for all side cable entry through glands of size 250x200x100mm with 4Nos. aluminium bus bar of size 25x6mm, 8Nos. terminals with and including 01No. 10Amp MCB 10kA duly mounted fixed with MS clamps fabricated out of FI 40x3mm of required shape and size and fied at any location complete all as specified and as directed |
| 55 | Supply and fixing PVC insulated copper conductor cable, 3 core 1.5sqmm, served with inner sheathing of PVC tape and overall PVC sheathed, 1100V grade heavy duty in connections complete all as specified. |
| 56 | Material and labour for Making bore to road/cement path/hard standing for providing GI pipe 40mm both end socketed for passing armoured cable incl making good the disturbed surface complete all as specified. |
| 57 | For Credit Schedule refer tender documents. The amount of credit schedule shall be deducted from total quoted amount of BOQ to arrive contract sum. Please Enable Macros to View BoQ information |