| 1 | Taking down fan of any type/make and size of AC ceiling fan, carefully from fan hook, and transporting to MES E/M store yard, and refixing on same location or other location complete all as specified and as directed.( Cost of repairing including replacement of spares if any will be measured and paiid seperately under relevent items of this schedule. |
| 2 | Cutting the existing copper winding of AC ceiling fan 1200 mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 metres long size 24/0, 020 (ISI marked) all insulating materials including varnishing, heating and drying complete including satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge. |
| 3 | Cutting the existing copper winding of AC ceiling fan 1400 mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 metres long size 24/0, 020 (ISI marked) all insulating materials including varnishing, heating and drying complete including satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.Note:- For Item No 1 to 3 Replacement of defective/ unserviceable parts shall be measured and paid separately in respective items as supply only. |
| 4 | Supply only ball bearing of size 6201/6202 suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed. Make : NBC/SKF/SBBI |
| 5 | Supply only condenser ISI marked 230/240/250 volts AC 2.5 Mfd suitable for ceiling fan.(Make : Usha/Asian/EPCOS/Universal). |
| 6 | Supply only bush bearing suitable for any type/make of ceiling fan complete all as specified and as directed. |
| 7 | Supply only rubber reels including shackle clamp, bolts, nuts, washers split pins of appropriate size as required complete all as specified and as directed. |
| 8 | Supply only down rod 15mm dia GI pipe heavy duty 45 cm long including machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable for any size and make of fan complete all as specified and as directed. |
| 9 | M & L for painting of ceiling fan complete with blades ,in situ with synthetic enamel paint Duco by spraying including filling cavities with filler ,ones coat after cleaning all dust etc.complete all as specified and as directed. |
| 10 | Taking down exhaust fan of size 200mm to 300mm sweep of any make and transporting from any location to MES E/M store yard, and refixing on same location or other location carefully after repairing, washing by petrol ,greasing, replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same including provision of twisted twin core flexible wire upto 0.7 meters long size 24/0, 020 (ISI marked) and testing the fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and as directed.Note:- Replacement of defective/ unserviceable parts if required shall be measured and paid separately under respective items . |
| 11 | All as per item serial No 10 here-in-before but exhaust fans 300 mm sweep to 450 mm sweep complete all as specified and as directed. |
| 12 | Rewinding the armature for 200mm to 300mm sweep exhaust fan any make with super enamelled copper wire of suitable size with and including all insulating materials varnishing complete all as specified and directed.Note:- Replacement of defective/ unserviceable parts if required shall be measured and paid separately under respective items . |
| 13 | All as per item serial No 12 here-in-before but exhaust fans 380 mm sweep omplete all as specified and as directed. |
| 14 | All as per item serial No 12 here-in-before but exhaust fans 450 mm sweep complete all as specified and as directed. |
| 15 | Supply only ball bearing suitable for exhaust fan 300 mm sweep complete all as specified and as directed. Make : NBC/SKF/SBBI |
| 16 | Supply only ball bearing suitable for exhaust fan 380/450 mm sweep all as directed.(Make : NBC/SKF/SBBI) |
| 17 | Supply only bush bearing made out Gun metal suitable for any type/make of Exhaust fan. |
| 18 | Supply only condenser ISI marked 230/240/250 volts AC 4.0 Mfd suitable forexhaust Fan.(Make : Usha/Asian/EPCOS/Universal). |
| 19 | Taking down wall/cabin fans of any sweep carefully from site & transporting from any location inside Army area to MES E/M store yard for repairing complete all as specified and as directed. |
| 20 | Rewinding the armature for 400/ 450 mm sweep wall / cabin fan any make with super enamelled copper wire of suitable size with and including all insulating materials varnishing complete all as specified and directed. |
| 21 | Re-Metalling the worn out shaft at bush/ ball bearing seat by brazing/ welding and machining for proper fixing of ball bearing/ bush of any size of ceiling fan/ Exhaust fan/ wall fan complete all as specified and directed. |
| 22 | S&F in repairs hook for hanging ceiling fan size as per site requirement including nut,bolts &clamps complete all as specified and as directed |
| 23 | Taking down unserviceable Geysers of any capacity from its location by disconnecting and sealing all electrical and water lines for painting/maintenance/servicing/overhauling , opening the same for repair/ replacement of unserviceable parts, including cleaning , taking out sludge from inner tank and washing with cleaning solution and reassembling and refixing the same in its original location /position , connecting all electrical and water connection and testing complete all as specified and directed.Note : (a) New parts shall be measured and paid separately under \\"Supply only\\" rates here-in-after.(b) Minor Part if any , not mentioned in the schedule but required for smooth functioning of geyser are deemed to be included in the unit rate of the item. |
| 24 | Supply only thermostat switch for 25/50 Ltrs Geyser, 230 V, 30 degree to 90 degree centigrade temp range to be set at 70 degree to 50 degree centi grade suitable for water heater complete all as specified and as directed. |
| 25 | Supply only heating element 1500 Watts with round/triangular base, push and clamp fixing type suitable for 25/50 Liters capacity geysers. |
| 26 | Supply only heating element 2000 Watts with round/triangular base, push and clamp fixing type suitable for 25/50 Liters capacity geysers. |
| 27 | Supply only copper container suitable for Geyser 25 ltr complete all as specified and as directed. |
| 28 | Supply only copper container suitable for Geyser of 50 ltr capacity complete all as specified and as directed |
| 29 | S&F in replacement of heating elements of 1.5 KW 230 V suitable for water heater of any type including connection with suitable cable complete all as specified and as directed. |
| 30 | S&F in replacement of heating elements of 2 KW 230 V suitable for water heater of any type including connection with suitable cable complete all as specified and as directed. |
| 31 | Supply only glass wool for insulation of tank as approved. |
| 32 | M& L in repair Air termination, single pointed, Copper rod 12 mm dia and 300 mm long completed all as specified and as directed. |
| 33 | M & L for test point teminal block made of gun metal or phosphorus bronze size 75x75x25 mm ,drilled and screwed including 3 nos 8 mm 25 mm long hexgonal Head screw including taking out old one completed all as specified and as directed. |
| 34 | M & L for Copper strip 25 x 3.15mm to be fix on top of \\"V\\" type porcelain insulator or DMC insulator of suitable size and fixing screws etc. for roof conductors and down conductors above ground including taking out old strip of any description complete all as specified and as directed. |
| 35 | M&L for plate earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and connected to 20x3mm copper strip as earthing lead by means of clamps, bolts, nuts and washer made of galvanised iron or steel and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I, including dismantling of old ones complete all as specified and directed. Please Enable Macros to View BoQ information |