| 1 | Construction of tube well from ground level & up to 100 mtr depth accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part 11: 1979 (both amended up to date) and technical specifications, with gravel as per IS.4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and acking during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, work, but excluding the t cost co of housing and strainer pipe assembly). The work would be completed after obtaining sand free water. |
| 2 | Nominal bore 200 mm dia |
| 3 | Construction of Tube Well up to 150 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in al types of soil & over burden including lowering of casing pipe, (if required) excluding cost of casing pipe, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. |
| 4 | Nominal bore 200 mm dia |
| 5 | Add 15% extra on depth more than 150 mtr for drilling beyond 150 mtr depth from ground level |
| 6 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes |
| 7 | 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) |
| 8 | Labour charges for making slots on blank pipes made of ERW MS black pipe of following sizes, the slotting should be as per IS-8110-2000 or as amended up to date. |
| 9 | 200 mm dia nominal bore. |
| 10 | Providing & laying ISI marked Gl Pipe Light duty (\\"A\\" Class) as per IS:1239 part I 2004 or ainended up to date for casing pipe for submersible cable external/internal work 40 mm dia complete in all respect. |
| 11 | Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of subinersible pump set and interconnection up to water mains, complete in all respect. |
| 12 | Up to 5.5 KW (7.5 IIP) & head above 120 mtr. |
| 13 | Supply and Fixing ofelectric control feeder panel comprising of suitable rating MCCB, fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete olete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand (made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg's length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level The panel should have opening of suitable size in front of space for energy meter with glass for meter reading The operation of panel should be suitable for 440 Volt AC Supply. |
| 14 | Above 5 HP and up to 10 HP |
| 15 | Supply & Fixing of ISt marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc |
| 16 | 3 core 4.0 Sq.mm |
| 17 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-1/1554-1 approved make in ground as per 1S:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling carth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 18 | 16.0 Sq.mm, 4 core |
| 19 | Plate Earthing as per IS:3043 with G.1. Earth plate of size 600mm x 600mm x 6 Onm by embodying 3 to 4 mtr. below the ground cround level with 20 mm dia. G.I 'B' class watering Pipe including all accessories like nut, bolts, reducer,nipple, wiremeshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I Cover, C.1. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required |
| 20 | Supply & Fixing MS clamp set of 50x6 mm flat from iron with nuts and bolts etc for lholding the riser pipe assembly of submersible pump set. |
| 21 | Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. |
| 22 | 200 mm dia |
| 23 | Providing & Lowering in tubewell ISI marked GI Pipe \\"B\\" (medium) class as per IS. 1239 part 1 2004 or amended up to date, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts ete complete in all respect. |
| 24 | 50 mm dia |
| 25 | Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. |
| 26 | 50 mm dia |
| 27 | Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge. |
| 28 | Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes |
| 29 | 65 mm dia |
| 30 | Supplying & Installing 100 mm diameter., sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per pressure specification with safety cover. |
| 31 | Providing, lowering, laying and Jointing in trenches, standard lengths HDPE ISI marked Plpes as per IS-4984: 1995 (amended up to date) with necessary Jointing material like mechanical connectors, I.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, Including all taxes transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work).Note: Providing and fixing ofall requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. |
| 32 | HDPE PE-80 PN-6 |
| 33 | 90 mm dia |
| 34 | 110 mm dia |
| 35 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes, transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note: Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 М. |
| 36 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil |
| 37 | Supply & Installation of 3 phase ISI marked submersible motor pump set of five star (if not available then three/ four star whichever higher rating available) rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories ineluding making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. |
| 38 | Up to 5.5 KW (7.5 HP) & head above 120 mtr |
| 39 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. |
| 40 | 3 core 4.0 Sq.mm |
| 41 | Supply and Fixing ofelectric control feeder panel comprising of suitable rating MCC3, fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter (supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimumsize 900 x 600 x 450 mm with Stand (made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg's length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. |
| 42 | Above 5 HP and up to 10 HP |
| 43 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (\\"B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. |
| 44 | 50 mm dia |
| 45 | Supply & Fixing XLPE insulated/P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-1/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 46 | 16.0 Sq.mm, 4 core |
| 47 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifieations: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 Body Seat ring, Wedge facing ring & Bushes - LTB2/SS, Face to face dimensions as per IS 14846/2000 (amended up to date),Epoxy (NonToxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick. Sluice valves including all jointing & jointing material, labour, testing and commissioningalong with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 48 | Manually Operated CI Sluice valve of Class PN-1.0 |
| 49 | 80 mm dia |
| 50 | 125 mm dia Please Enable Macros to View BoQ information |