|
| 1 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. MS pipe specials upto 600 mm dia (with minimum 5.0 mm thickness sheet) |
| 2 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. MS pipe specials upto 600 mm dia (with minimum 5.0 mm thickness sheet) |
| 3 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications:Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date), Epoxy (Non-Toxicsuitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM |
| 4 | 80 mm HW |
| 5 | 100 mm HW |
| 6 | S & F of STAR DELTA STARTER IN THE EXISTING PANEL WITH FOLLOWING RATING |
| 7 | 7.5 KW to 9.3 KW |
| 8 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil |
| 9 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes, transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class |
| 10 | HDPE PE-80 PN-6 |
| 11 | 90 mm dia |
| 12 | 110 mm dia |
| 13 | Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessorles Including making connection sultable for tube well/DCB. The Job Includes lowering of motor pump, Installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and Interconnection up to water malns, complete In all respect. |
| 14 | Up to 2.0 KW |
| 15 | Above 2.0 KW |
| 16 | Supply & Installation of 3 phase ISI marked submersible per motor pump set of three star or better rating of BEE and as IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with requlred accessorles Including making connection sultable for tube well/DCB, The job Includes lowering of motor pump, Installation of complete fitting & accessorles, jointing of electrical cables up to switch board, testing of submersible pump set and Interconnection up to water mains, complete in all respect. |
| 17 | Up to 5.5 KW (7.5 HP) & head up to 120 mtr. |
| 18 | Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indlcating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Helght 600 mm Width 500 mm depth 250 mm with Stand (made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg's length 18\\" and double door including In built locking system. The legs should be embedded In M-15 cement concrete platform. The slze of CС platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be sultable for on 240 Volt AC Supply. |
| 19 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, fully automatic star-delta starter. over load relay, ampere meter with CTs, volt meter, phase preventer, sultable starting capacitors, phase Indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg's length 18\\" and double door including in built locking system. The legs should be embedded In M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of sultable size In front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. |
| 20 | Above 5 HP and up to 10 HP |
| 21 | Above 10 HP and up to 15 HP |
| 22 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 Including making connectlon etc. |
| 23 | 3 core 4.0 Sq.mm |
| 24 | 3 core 6.0 Sq.mm |
| 25 | Supply & Fixing XLPE Insulated/P.V.C. sheathed cable of 1.1 KV grade with aluminlum conductor Armoured of 15:7098. 1/1554-1 approved make In ground as per IS:1255 Including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 26 | 10.0 Sq.mm, 4 core |
| 27 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (\\"8\\" class), Steel tube as per 15:1239 or amended up to date and zinc coating as per 1S 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect |
| 28 | 32 mm dia |
| 29 | 50 mm dia |
| 30 | Providing and laying in position cement concrete in specifled grade over prepared base course complete Including finishing, curing, all materlal, labour, machinery, lighting, guarding for road restoratlon work in trenches of pipe line and chamber work, Measurement for CC work to be made as per standard trench width specifled In tender document and no extra payment shall be made be made for trench width more than specifled, complete work as per technical specification and scope of work. |
| 31 | M20 grade Nominal MI 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nomlnal size). Please Enable Macros to View BoQ information |