| 1 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (Polycab, KEI, Havells make) |
| 2 | (a) 10 Sq.mm. x 4 Core (PS No. 501) |
| 3 | (b) 16 Sq.mm. x 4 Core (PS No. 501) |
| 4 | (c ) 50 Sq.mm. x 3.5 Core (PS No. 501) |
| 5 | S/F of Palm or Pin type copper tin plated cable socket (lugs) to the cable lead insulation with tape and making connections complete as per direction of E/I. P.S. No. 504 |
| 6 | a)- 16 sq. mm |
| 7 | b)- 25 sq. mm |
| 8 | c)- 35 sq. mm |
| 9 | d)- 50 sq. mm |
| 10 | S/E of overhead line with ACSR conductor on steel tubular poles incl. compression joint, laying stringing and binding etc. as PS No. 627 |
| 11 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000mm, outer pipe 50mm, inner dia 25mm, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.(P.S. No 725B) |
| 12 | Providing and making steel pole collar with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) of specified size and shape including form work, plastering if required, curing etc. as required. (Volume of pipe/pole not to be deducted)(Electrical DSR-14/Ite. No. 11.5 pg.37) |
| 13 | Supply and making straight through joint with cast resin compound including ferrules and other joints material for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required |
| 14 | a) 3.5x70 sq. mm ((Electrical DSR-18/Ite. No. 9.3.20 pg.35) |
| 15 | a) 2x25 sq. mm ((Electrical DSR-18/Item. No. 9.3.2 pg.36) |
| 16 | Dismantling of pole/Street Light standard /strut embedded in cement concrete foundation etc. as required (Electrical DSR-2018/item no. 12.42 P-46) |
| 17 | Errection of metallic pole of following length in cement concrete 1:3:6 ( 1cement:3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required above 10.0 mtr and upto 12 mtr (Electrical DSR 2018 I. n. 11.3.4 ) |
| 18 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m. The contractor has detect different utilities like sewer line, water supply line, electric cable, Telephone cable, Gas pipe line etc. using utility detecting machine before start of excavatiob and shall start excavation only after permission of Engineer in charge. All kind of soil. |
| 19 | Filling available excavated earth( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead upto 50 m and lift upto 1.5 m. (AOR) |
| 20 | S/Laying of 90 mm dia (OD 90 mm & ID 76 mm nominal) size of (DWC) HDPE Pipes ISI marked along wigh all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete for drawing of power cable across the road by drilling of 120mm dia at 1Mtr. below the road level there by doing the work of providing DWC pipe by manual Trenchless method. with filling and cutting, jointing etc Complete in all respects Rex/Duraline/Time/CPE make. (AOR) |
| 21 | Supply and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. (Electrial DSR-2018, Item No. 10.5) |
| 22 | (a) 120 Sqmm ( Item No. 10.5.2 P-37) |
| 23 | (b) 240 Sqmm ( Item No. 10.5.3 P-37) |
| 24 | S/F of sintex type junction box model no. IIGSJB 2817 of size 240x140x110mm with hinges and locking arrangment & MS clamp of 50x6mm flat, complete in all respects including 2 no. G.I pipe 1.5\\" dia having 1.0 meter length each and chuck nut for cable connection etc. as per direction of E/I. (AOR) |
| 25 | Supply and fixing Pole bus bar support connector 4 way with backsheet i/c connection of cable complete in all respect. |
| 26 | Supply and fixing of 6 mtr G.I. octagonal pole of approved make ( top dia 70 mm, bottom dia 130 mm and base plate 12 mm thick) having 3 mm thickness with single arm bracket ( 1 mtr length) in 1:2:4 RCC foundation including the cost of foundation , foundation bolt, excavation & back filling required T & P complete in all respects (foundation Height above 45Cm. above Ground level or as per direction of E/I) (PS No. 647) (Make -Bajaj/Valmont/Transrail) |
| 27 | Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Double arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect.(foundation Height above 45Cm. above Ground level including shifting old lights to new pole) (PS No. 648) (Make - Bajaj/Valmont/Transrail ) |
| 28 | Supply and making Straight Through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. (Electrial DSR-2018, Item No. 10.6) |
| 29 | (a) 120 Sqmm ( Item No. 10.6.2 P-38) |
| 30 | (b) 240 Sqmm ( Item No. 10.6.3 P-38) |
| 31 | Supply and fixing of XLPE insulated Aluminium unarmoured cable for working voltage for enerizing the distribution boxes and street light of size 1x 16 Sq. mm all respect as per E/I. |
| 32 | Supply and fixing of LED Strip Light 5W/M with life L 70/40000 burning hr. of reputed LED make saffran/white/green dachable in 1M suitable for 240V AC 30m of strip for out door use with 3 year warranty complete in all respect as per direction fo E/I |
| 33 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (DSR-2018/Item No. 1.17.2) (1.5S Q. MM 2 CORE) |
| 34 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.(PS no 716/ P-138) |
| 35 | S/F of 100x110mm Shackle insulator/ 100x80 mm pin insulator including G.I. bolts/spindle nuts etc. Complete in all respects PS No. 621 |
| 36 | S/F of 230x32x1.5 mm galvanised steel strips including holes for shackle insulator pins and bolts etc. complete in all respects. As per P.S. No. 622. |
| 37 | S/E of \\"D\\" Clamp of 50x6 mm. M.S. flat iron on steel tubular poles/steel rail poles with bolts and nuts etc. complete in all respects. As per direction of E/I. P.S. No. 623. |
| 38 | S/F Ampere Meter (Make AE/Procom/Conzerve) |
| 39 | S/F Volt Meter (Make AE/Procom/Conzerve) |
| 40 | Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 3 output (1output per phase) and suitable for three phase supply.(DSR - 2018/ I.No. 15.4.3/p-51) |
| 41 | S/F 3 pole Power contractor AC3 40 Amp. (Make L&T/ Siemens/ Schnieder) |
| 42 | S/F of 63 Amp T.P. Isolator CAT A (for Street Light Panel ) PS No. 1006(B) |
| 43 | S/F of 6 Amp. to 32 Amp. S.P. MCB(10KA) C curve CAT A (for Street Light Panel ) PS No. 1002. |
| 44 | Painting with Zinc paint on existing Street Light Poles using spray Gun including all machinery labour T&P complete as per direction of E/I. |
| 45 | Electrician Per day as applicable in authority labour supply. |
| 46 | Helper Per day as applicable in authority labour supply. |
| 47 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required (AOR) |
| 48 | (a) (Bituminous Portion) (AOR) |
| 49 | (b) Water Bound Macadam (AOR) |
| 50 | Demolishing cement concrete manually/ by mechanical means including disposal of material with in 50 Mtr. Lead as per direction of E/I. Nominal concrete 1:3:6 or richer mix(i/c equivalent design mix) |
| 51 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.(AOR) |
| 52 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin-charge. (Old CC paver blocks shall be supplied by the department free of cost). |
| 53 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 54 | Hiring of welding set charges running time @ 6 hrs (AOR) |
| 55 | Hiring of Gas cutting set with oxygen and LPG running time 6 hrs (AOR) |
| 56 | Repairing of 11KV fuse wire/Jumper i/c supply and fixing of required size conductor, fuse wire of 11KV Line/DP structure of Transformer by takinng shutdown from UPPCL Department with all safety instruments like-safety belt, Gloves, shoes and other necessary items complete including all taxes. |
| 57 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. (DSR 2018 item no. 12.34 page no. 42) |
| 58 | Location and pin pointing of LT cable fault exposling the same in the underground LT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable, by making experts technical staff. Complete in all respects as per direction of Engineer in charge (AOR) |
| 59 | Location and pin pointing of 11 KV HT cable fault exposling the same in the underground 11KV HT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable by providing fault location machine with operator (Cable fault locator) Complete in all respects as per direction of Engineer in charge (AOR) |
| 60 | Location and pin pointing of LT cable fault exposling the same in the underground LT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable by providing fault location machine with operator (Cable fault locator) Complete in all respects as per direction of Engineer in charge (AOR) |
| 61 | Hiring charges of Mobile Hydraulic Crane 35 tonne capacirty (173HP) including fule and other T & P for shifting of Pole from One site to other site as per direction of E/I. Please Enable Macros to View BoQ information |