| 1 | Supply and Fixing of 16 Mtr High Mast pole of approved make with rising system, Hot dip galvanised inside & outside, having pole sheet thickness 3mm, top dia minimum 150 mm bottom dia miimum 360 mm base plate 32 m thick, suitable for wind velicity as per IS 875 part 3 & having no circumferential weld with accessories for High Mast such as heat frame suitable for 6 luminaries & its control gear boxes, 1.5 HP power tool motor, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufacturer drawing & site requirement along with foundation bolts, nuts, washer, Anchor plate etc. Complete in all respects as per direction and satisfaction to the Engineer-in-charge (PS No. 652) (MakeBajaj/Valmont/Transrail) |
| 2 | Supply and fixing of Factory wired integral LED Flood Light Luminaires with die cast Aluminium housing build with driver set suitable for 170 to 200 watt. Confirming to IP66 and above protection. Complete in all respects. (PS No. 1455) CAT-AAA . (Make - LT/Bajaj/Havells/ Crompton/Philips/Wipro) |
| 3 | Supplying and Laying of 6 sq. mm 2 core PVC Insulated Al. moued cable for street Light pole (as per RESPO-2018) annexure -3 pg. 17. |
| 4 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000 mm, Outer pipe 50mm, inner pipe 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive and conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra.) ps 725(A) |
| 5 | Supply and fixing of 25 Amp TPN capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint crossing of time switch TSO 100 series with contractors, HRC fuse, isolating swtich metering instrument & instrument box with CTs etc. in case of TPN, Complete in all respects. as per PS No. 807E |
| 6 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (KEI/ Havells/ Polycab make) (PS No 501) |
| 7 | 16 Sq.mm. 4Core (PS No. 501) |
| 8 | 10 Sq.mm. x 2 Core |
| 9 | 70 sq mm 3.5 core (PS No 501) |
| 10 | S/F of Plain of pin type copper tin plated cable socket(lug) to the cable leads, insulating with tape and making connection etc. Complete in all respects as per direction for E/I (PS No. 504) |
| 11 | 70 Sq.mm. |
| 12 | 16 sq. mm |
| 13 | 10 sq. mm |
| 14 | S/Laying of 90 mm dia (OD 90 mm & ID 76 mm nominal) size of (DWC) HDPE Pipes ISI marked along wigh all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete with filling and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation and refilling the trench pat excluding sand cushioning and protective covering etc. Complete in all respects. Rex/Duraline/Time/CPE make. as per DSR 2018 item no. 14.16.2 page no. 49 |
| 15 | laying of 90mm dia DWC(Double wall corrugated) pipe across the road by Trenchless method(Manual).AOR |
| 16 | Demolishing cement concrete manually/ by mechanical means including disposal of material with in 50 Mtr. Lead as per direction of E/I. Nominal concrete 1:3:6 or richer mix(i/c equivalent design mix) (AOR) |
| 17 | Filling available excavated earth( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead upto 50 m and lift upto 1.5 m. (AOR). P- |
| 18 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required (AOR) |
| 19 | a) Bituminous Portion (AOR) (2265.0+18% gst) P- |
| 20 | b) Water Bound Macadam (AOR) (1400.0+18% gst) P- |
| 21 | SITC of Outdoor Architectural LED Circular projector flood light with system wattage not more than 50W,system efficacy>45LPW(+5%),CCT RBGW(W=3000k) with 4 in 1 LED chip for uniform illumination ensuring every LED in Luminare reproducing same color at all time ,system lumen output should not less than 2160lm(10%) with all RBGW channels ON.Fixture should have Integral Driver & 4 channel Decoder,Fixture should be compatiable for DMX512 and able to reproduce 16 Millon colors with 256 step dimming.AOR |
| 22 | Supply, Installation, testing & Commissioning of flexible copper power cable 3 x 2.5 sqmm . AOR |
| 23 | Earth work in Excavation in by mechanical means (Hydraulic excavator) manual means over areas excaading 30 mtr in depth,1.50 mtr width as well as 10sqm on plan)including out and desposal of excavated earth ,load upto 50m and lift upto 1.5 m as directed by the Engineer incharge The Contractor has defect diffrent utillities like Sewer line,water supply line,electric cable,telephone cable,gas pipe line,etc.using utility defecting machine before start of excavation and shall start excavation only after getting permission of Engineer in charges.(AOR). P- Please Enable Macros to View BoQ information |