| 1 | Wiring points for light with 1.5 sqmm FR PVC insulated multistrand single core copper conductor cable (drawn through existing concealed PVC conduit) with 1.5 sqmm PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit and 5 amp flush type switch & ceiling rose/angle/batten holder fixed on 3mm thick phenolic laminated backelite sheet with brass machine screw and brass cup washers mounted over existing MS switch board box/junction box with supply of all material, labour and T&P etc. required for proper completion of the work as directed at site by the Engineer I/C PS No. 174 (C) |
| 2 | Wiring points for ceiling fan (light duty exhaust fan) with 1.5 sqmm FR PVC insulated multistrand single core copper conductor cable (drawn through existing concealed PVC conduit) with 1.5 sqmm PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit and 5 amp flush type switch & ceiling rose/angle/batten holder fixed on 3mm thick phenolic laminated backelite sheet with brass machine screw and brass cup washers mounted over existing MS switch board box/junction box with supply of all material, labour and T&P etc. required for proper completion of the work as directed at site by the Engineer I/C PS No. 177 (C) |
| 3 | Wiring points for Plug point with 1.5 sqmm FR PVC insulated multistrand single core copper conductor cable (drawn through existing concealed PVC conduit) with 1.5 sqmm PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit and 5 amp flush type switch & ceiling rose/angle/batten holder fixed on 3mm thick phenolic laminated backelite sheet with brass machine screw and brass cup washers mounted over existing MS switch board box/junction box with supply of all material, labour and T&P etc. required for proper completion of the work as directed at site by the Engineer I/C PS No. 178 (C) |
| 4 | Wiring points for HPMV/SV with 1.5 sqmm FR PVC insulated multistrand single core copper conductor cable (drawn through existing concealed PVC conduit) with 1.5 sqmm PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit and 15 amp flush type switch & ceiling rose/angle/batten holder fixed on 3mm thick phenolic laminated backelite sheet with brass machine screw and brass cup washers mounted over existing MS switch board box/junction box with supply of all material, labour and T&P etc. required for proper completion of the work as directed at site by the Engineer I/C PS No. 180 (C) |
| 5 | Wiring point for exhaust fan with 1.5 sqmm FR PVC insulated multistrand single core copper conductor cable in 2mm thick PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm FR PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit,15 A piano type switch & ceiling rose on 3mm thick phenolic laminated backelite sheet etc. complete in all respects including matching colour wash.(Heavy duty Ex. Fan) PS No. 144 (C) |
| 6 | Supply and fixing of power plug with 15A/250 V flush type switch and 5 pin 15A/250V flush type flush universal socket in suitable MS box of 175mm x 100mm x 50 mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. PS No. 1139 |
| 7 | Supply and wiring of submains with 2 nos. 2.5 sq mm & with 1 no earth wire of 1.5 sq mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. PS 291 |
| 8 | Supply and wiring of submains with 2 nos. 4 sq mm and 1 no 2.5 sq mm FRLSH PVC insulated copper conductor cable in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. PS 291(A) |
| 9 | Supply and wiring of submains with 2 nos. 6 sq mm and 1 no 4 sq mm FRLSH PVC insulated copper conductor cable. in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. PS 291(D) |
| 10 | Supply and wiring of submains with 2 nos. 10 sq mm and 1 no 6 sq mm FRLSH PVC insulated copper conductor cable. in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. PS 291(G) |
| 11 | Supply & fixing of 5Amp to 32 Amp SP MCB (10KA) (Legand make) PS No. 1002 Cat (A) |
| 12 | S&F of 63 Amp. 4 pole MCB(10 KA) C Curve Complete in all respects PS No.1020 Cat A |
| 13 | S/F surface/flush mounting 8 ways TPN distribution board without additional board without MCB complete in all respect and as directed at site. PS No. 1028 Cat A |
| 14 | Supply and fixing of 100 Amp. four pole change over switch on 40mm x 40mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. PS No. 378 |
| 15 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect complete in all respects. P.S.No. 1413 CAT AAA |
| 16 | Supply and fixing of fan hook fabricated from M.S. rod for ceiling fan each.PS NO 1123 |
| 17 | Supply and fixing and concealing of 25 mm dia 2mm thick PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and T&P etc. required for proper completion of the work as per directions and to the satisfaction of Engineer I/C. (conduit for telephone, computer cable) . PS No. 149 (A) |
| 18 | Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. PS No. 1406 Cat A |
| 19 | Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect. PS No. 1410 Cat A |
| 20 | Supply and fixing of Electronic fan regulator 120-280V. ISI marked, on existing switch board including making connections, required material, labour T/P etc. for proper completion of work to the satisfaction of Engineer I/C of work. PS No. 1203 A |
| 21 | S/L of Al. conductor PVC/XLPE insulated armoured served sheathed cable 1100 V grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround & protected with bricks on sides & top on surface, the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the E/I. complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (Grandley, Gloster, Kalinga, Havells, Nicco, Plaza Make) PS No. 501 i) 16 sq. mm 2 core |
| 22 | 70 Sqmm x 3.5 Core |
| 23 | S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads making connections etc. complete in all respects as pe direction of E/I PS No. 504. b) 16 Sq.mm |
| 24 | c) 70 Sq.mm |
| 25 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 25 A TPN PS No.-807 e (ii) |
| 26 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. DSR 14.16.1a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 27 | b) 90 mm dia (OD-90 mm & ID-76 mm nominal) (14.16.2) |
| 28 | S/L of 3\\" (80mm) dia G.I. Pipe 'B' Class in the ground level including road cutting Complete in all respects as per direction of E/I DSR Electrical-18 12.38 |
| 29 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects. PS No. 716 |
| 30 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50mm, inner Dia 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity one earth lead of 25mm x 3mm G.I. Strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra.) along with 30 cm squrare C.I. frame with hinged cover masonry housing . ps 725 (B) 2018 |
| 31 | Supply and fixing of ceiling fan 1200 mm dia (ISI Mark) (AOR) Make- Crompton, havells, Bajaj or equivalent make |
| 32 | Supply, Installation, testing and commissioning of 300 mm dia 900 R.P.M exhaust fan with louvered Shutters(AOR) |
| 33 | S&F of 100 Amp. 415 V metal clad TP HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect. PS 324 |
| 34 | Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. PS No 647 (Make : Bajaj/Philips/BPP/Crompton) |
| 35 | Supply, Installetion, Testing & Commissioning of 450 mm dia 1400 R.P.M Exhaust fan with lovuvred shutters (AOR) |
| 36 | fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect.PS No.1423 CAT- AAA |
| 37 | Demolishing Cement Concrete manually by mechanical means including disposal of material within 50 mtr lead as per direction of Engineer-in-Charge, Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) DSR Civil 15.2.1 (AOR) |
| 38 | Cement Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.07/S.N. 279 |
| 39 | Cement Concrete with 4cm gauge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.08/S.N. 281 |
| 40 | Taking out existing c.c. interlocking paver blocks from foothpath/central verge, including removal of rubbish etc. disposal of unserviceable material to the dumping ground, for which payment shall be made seperately and stacking off serviceable material withing 50 mtr lead as per direction of E/I (AOR) |
| 41 | Laying Old cemennt concrete interlocking paver blocks of any design/shape laid in required line, level currative colour and pattern over and including 50mm thick compacted bed of course sand filling the joint with fine sand etc. all complete as per direction of E/I (Old CC Paver block shall be supplied by the deptt free of cost) (AOR) Please Enable Macros to View BoQ information |