| 1 | Excavation in foundation in ordinary soil (Loam, Clay or Sand) Including lift upto 1.50 m and lead upto 30m and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer In-charge upto a distance of 30m from the foundation trenches. |
| 2 | Providing and laying cement concrete in 1:6:12 (1 cement : 6 Coarse sand : 12 Graded stone aggregate 40mm nominal size) including supply of all materials, labours and T&P etc. required for proper completion of the work. SI. No. 273 a |
| 3 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. including cost of centering, shuttering, finishing and excluding reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) upto plinth level. DSR SP No. 5.2.2(I) |
| 4 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. including cost of centering, shuttering, finishing and excluding reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) above plinth level. DSR SP No. 5.2.2(I) |
| 5 | Reinforced cement concrete work in in beams, suspended floors roofs having slope upto 15 landings, balconies, shelves, chajjas, lintles, bands, plaint window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering shuttering finishing and reinforcement with 1:1.5:3 ( 1cement:1.5coarse sand:3 graded stone aggregate 20mm nominal size) DSR 5.3 |
| 6 | Class-150 (Non Modular) brick work in 1:4 cement and Coarse sand mortar in foundation of plinth including supply of all materials, labour and T&P etc. required for proper completion of the work. (Coarse Sand not less than 2.25 FM) DSR SPL No. 6.4.1 (P-30) |
| 7 | Class-150 (Non Modular) brick work in 1:4 cement and Coarse sand mortar in super structure including supply of all materials, labour and T&P etc. required for proper completion of the work. (Coarse Sand not less than 2.25 FM) DSR SPL No. 6.4.1 (P-30) |
| 8 | Mild steel or iron work in plain work such as reinforced concrete or reinforced brick work (When not included in and an over all rates) brought to required shape as necessary including bending for proper completion of the work and excluding the supply of steel and its wastage Bend, hooks and authorized over lapping shall be measured upto floor to level.SI No 504 (Unnao) |
| 9 | Steel work in built up tubular (round,square or rectangular hollow tubes etc.) truses etc. including cutting, Hoisting fixing in positin and applying a priming coat of approved steel primer, including welding and boted with special shaped washers etc. complete. (Hot finised welded type tubes. |
| 10 | 12 mm cement plaster on brick work 1:4 (1 cement : 4 Coarse sand) with cement mortar of mix (All floors) including supply of all materials, labours and T&P etc. required for proper completion of the work. SI No 584 |
| 11 | Making grooves 10 to 12mm wide x8mm deep in plaster of the wall or in celing vertically or horizontally as required pwd SI. No. 598 (I) |
| 12 | Painting Two coats over work on steel and wood work surfaces upto 10cm width or girth or small articles not exceeding 0.10 Sqm in area with superior synthetic enamel such as Luxol 3, Hi gloss Apcolite, Superlac, Dulux specified brushing to give and even shade and including the cleaning the surface of all dirt, dust and other foreign matter sand papering and scrapping including cost of all materials, labour, tools and plants etc. required for proper completion of work. DSR SP. No. 13.61.1 |
| 13 | Painting walls with textured exterior paint of required shade : New work (Two or more coat applied @1.67 ltr/10sqm over and including priming coat of exterior primer applied @ 2.20 KGg/10sqm) . PWD SI. No 13.45.1 |
| 14 | Dismantling brick work or stone work in line or cement mortar and including stacking of materials as directed by Engineer-in-Charge within a distance of 60 meters (200 feet). |
| 15 | Deduct M-150 Class old brick 50% of item No. 14 |
| 16 | Class-150 (Non Modular) brick work in 1:4 cement and Coarse sand mortar in foundation of plinth including supply of all materials, labour and T&P etc. required for proper completion of the work. (Coarse Sand not less than 2.25 FM) DSR SPL No. 6.4.1 (P-30) |
| 17 | Providing and laying cement concrete in 1:2:4 (1 cement : 2 Coarse sand : 4 Graded stone aggregate 40mm nominal size) including supply of all materials, labours and T&P etc. required for proper completion of the work. SI. No. 279 |
| 18 | 12 mm cement plaster on brick work 1:4 (1 cement : 4 Coarse sand) with cement mortar of mix (All floors) including supply of all materials, labours and T&P etc. required for proper completion of the work. SI No 584 |
| 19 | Providing and laying in position specified grade reinforced cement concrete,1:1.5:3 (1 cement : 1.5 Coarse sand : 3 stone grit including cost of centering shuttering, finishing, and excluding renforcedment all work of pilinth level SI No. 279 (5.3) |
| 20 | Steel reinforcement for R.C.C. Work including straightening, cutting, bending. Placing in position and binding all complete upto pilinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. Please Enable Macros to View BoQ information |