| 1 | Providing and fixing 300 mm long bracket fabricated from angle iron 25 mm x 25 mm x 3 mm on the existing border fence angle iron post complete with G.I. bolt, nut and washer, including painting with one coat primer and two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture, including providing and fixing bobbin insulator of size 40 mm x 30 mm (nominal size) at one end of bracket with GI nut, bolt and washer, drilling of holes etc as required compete. (as per drawing provided by the Engineer in charge) |
| 2 | Providing and fixing 450 mm long bracket fabricated from angle iron 25 mm x 25 mm x 3 mm on the existing border fence angle iron post complete with two nos. G.I. bolts, nuts and washers, including painting with one coat primer and two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture, including providing and fixing bobbin insulator of size 40 mm x 30 mm (nominal size) at one end of bracket with GI nut, bolt and washer, drilling of holes etc as required compete. (as per drawing provided by the Engineer in charge) |
| 3 | Providing and fixing 600 mm long bracket fabricated from angle iron 25 mm x 25 mm x 3 mm on the existing border fence angle iron post complete with two nos. G.I. bolts, nuts and washers, including painting with one coat primer and two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture, including providing and fixing bobbin insulator of size 40 mm x 30 mm (nominal size) at one end of bracket with GI nut, bolt and washer, drilling of holes etc as required compete. (as per drawing provided by the Engineer in charge) |
| 4 | Supplying and erection of 2.59 mm dia G.I. High tensile wire with minimum of 230 gms/sq.m zinc coating on existing bobbin insulators fixed on B.S. fence, including binding with 2 mm dia aluminium wire etc. as required. ( G. I. wire Confirming to IS: 398 -Part II ) |
| 5 | Supplying and fixing weather proof thermoplastic indicator box size 217 mm x 253 mm x115mm with transparent hinged lid, including providing and fixing following accessories, inter-connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable, including one 40x3mm MS flat clamp with nuts, bolts and washers duly painted, fixing indicator box on existing Angle iron post etc complete as required. (make : box Hensel Catalog No. KG 9003)i) DIN Rail for five MCBs with fastening screws.- 1 Noii) MCB 'C' series 10KA, 6 amps. Make : C&S / L&T/ Legrand /ABB / Havells/ Siemens- 4 Nosiii) Mounting plate 180 mm x 136 mm made 3 mm thick phenolic laminated sheet with fastening screws including cutting to required shape. 1 Noiv) LED indicator 240 V. make : C&S/ L&T/ Legrand/ HPL/ Havells. - 4 Nosv) Grommets IP55 ESM 32-02 nos Hensel make vi) Grommets IP55 ESM 25-01 nos Hensel make |
| 6 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit or air as required. 2.5 Sqmm Make: Havells / Polycab / L&T / RR Kabel |
| 7 | Supplying and Laying of 2 X10 sq. mm size one number aluminium conductor, XLPE Insulated, PVC sheathed, unarmoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing DWC HDPE /RCC/ HUME/ METAL pipe as required. (ISI marked Make Havells /Polycab/ Finolex /KEI /RR Kabel) |
| 8 | Supplying and Laying of 2 x 10 sq. mm size one number aluminium conductor, XLPE Insulated, PVC sheathed, unarmoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing masonry open duct/ along surface/loose for connection etc as required. |
| 9 | Supplying and fixing bakelite terminal block of follwing size on the existing box/ switch board including connection etc as required. Terminal block, 2 way, 30 A, |
| 10 | Supplying and fixing bakelite terminal block of follwing size on the existing box/ switch board including connection etc as required.Terminal block, 4 way, 30 A, |
| 11 | Providing and fixing bottle type bobbin insulator of size 40 mm x 30 mm (nominal size) with GI nut, bolt and washer, on existing angle iron bracket including drilling of holes etc complete as required. |
| 12 | Supplying and fixing of 20 mm medium class PVC conduit along with accessories in surface as required. |
| 13 | Supplying and fixing sleeves on wires up to 2.5 sq mm Copper Conductor Single core Cables etc. as required. |
| 14 | Supplying and fixing of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE pipe ISI marked conforming to IS 14930, Part II complete with fitting and cutting, jointing direct in air with the support of pole/fance picket etc. complete as required. |
| 15 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 16 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 17 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. Direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. i) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 18 | A) TOTAL MR items Rs. (SRL NO 1 to 14) |
| 19 | B) TOTAL DSR items Rs. (SRL NO 15 to 17) |
| 20 | C) Add GST difference Multification Factor (0.0633) on DSR Item (B) |
| 21 | D) Add labourcess @1% on DSR Item amount D= 1% of (B+C) |
| 22 | G) Apply correction factor on DSR @0.973 i.e (*0.973) Please Enable Macros to View BoQ information |