| 1 | Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed. Note :- laying of cable route is same as old cable route . |
| 2 | Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 240 Sqmm, 3.5 core including testing after laid and jointed all as specified and as directed. Note:- Excavation and earth work, cable protection shall be measured and paid separetely. |
| 3 | All as per item No. 2 but cable size 185 Sqmm 3.5 core all as specified and as directed. |
| 4 | All as per item No. 2 but cable size 150 Sqmm 3.5 core all as specified and as directed. |
| 5 | All as per item No. 2 but cable size 120 Sqmm 3.5 core all as specified and as directed. |
| 6 | All as per item No. 2 but cable size 95 Sqmm 3.5 core all as specified and as directed. |
| 7 | All as per item No. 2 but cable size 70 Sqmm 3.5 core all as specified and as directed. |
| 8 | All as per item No. 2 but cable size 50 Sqmm 3.5 core all as specified and as directed. |
| 9 | All as per item No. 2 but cable size 35 Sqmm 3.5 core all as specified and as directed. |
| 10 | All as per item No. 2 but cable size 25 Sqmm 3.5 core all as specified and as directed. |
| 11 | All as per item No. 2 but cable size 16 Sqmm 4 core all as specified and as directed. |
| 12 | All as per item No. 2 but cable size 10 Sqmm 4 core all as specified and as directed. |
| 13 | Excavation in trenches in soft/loose of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables, poles, stay and getting out of excavated material complete all as specified and directed. |
| 14 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed. |
| 15 | Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point all as specified and as directed . |
| 16 | Supply and fix in repair Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 120 mm outer diameter and 103 mm inner Diameter with IS 16285 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. |
| 17 | Supply and fix in repair Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 90 mm outer diameter and 75 mm inner Diameter with IS 16285 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. |
| 18 | Supply and fix in repair Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 63 mm outer diameter and 51 mm inner Diameter with IS 16285 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. |
| 19 | Supply and fix in repair Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 50 mm outer diameter and 38 mm inner Diameter with IS 16285 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. |
| 20 | Material and labour for testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 Volt LT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed.Notes : (i) All T&P and other accessories required for checking and finding of fault in cable shall be provided by the Contractor (ii) Charges/rent of the fault locating mobile machine, operator, engineer, electricians etc shall be deemed to included rate quoted by Contractor. (iii) Checking and finding fault upto 05 places of same route of the cable will be considered as one Job. |
| 21 | Supply and fix in repair Heat shrinkable straight through cable jointing kit for 1100 Volts grade cable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 240 Sqmm. Note :- Any Excavation and earth work, Returning and filling, Removing involved shall be measured and paid separately. |
| 22 | All as per item No. 21 but cable size 70 Sqmm to 95 Sqmm all complete as specified and directed. |
| 23 | All as per item No. 21 but cable size 10 Sqmm to 50 Sqmm all complete as specified and directed. |
| 24 | S&F in renewal MCCB 63 Amps, 4 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 16 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed. |
| 25 | All as per item No. 24 but MCCB 100 Amps, with breaking capacity 25 KA complete all as specified and as directed. |
| 26 | All as per item No. 24 but MCCB 125 Amps, with breaking capacity 25 KA complete all as specified and as directed. |
| 27 | All as per item No. 24 but MCCB 160 Amps, with breaking capacity 36 KA complete all as specified and as directed. |
| 28 | All as per item No. 24 but MCCB 200 Amps, with breaking capacity 36 KA complete all as specified and as directed. |
| 29 | All as per item No. 24 but MCCB 250 Amps, with breaking capacity 36 KA complete all as specified and as directed. |
| 30 | All as per item No. 24 but MCCB 320 Amps, with breaking capacity 36 KA complete all as specified and as directed. |
| 31 | All as per item No. 24 but MCCB 400 Amps, with breaking capacity 36 KA complete all as specified and as directed. |
| 32 | S&F in renewal MCCB 63 Amps, 3 Pole, 415V, 50 Hz, Adjustable type, with breaking capacity 16 KA, Ics=100% of Icu, including taking down of old unserviceable MCCBs, complete all as specified and directed. |
| 33 | All as per item No. 32 but MCCB 100 Amps, with breaking capacity 25 KA complete all as specified and as directed. |
| 34 | All as per item No. 32 but MCCB 125 Amps, with breaking capacity 25 KA complete all as specified and as directed. |
| 35 | All as per item No. 32 but MCCB 160 Amps, with breaking capacity 36 KA complete all as specified and as directed. |
| 36 | All as per item No. 32 but MCCB 200 Amps, with breaking capacity 36 KA complete all as specified and as directed. |
| 37 | All as per item No. 32 but MCCB 250 Amps, with breaking capacity 36 KA complete all as specified and as directed. |
| 38 | All as per item No. 32 but MCCB 320 Amps, with breaking capacity 36 KA complete all as specified and as directed. |
| 39 | All as per item No. 32 but MCCB 400 Amps, with breaking capacity 36 KA complete all as specified and as directed. |
| 40 | Supply and fix in repair LED street light luminaires of capacity 60 watts with pressure die cast aluminium housing heat resistance toughened glass, IP 66 protection and efficacy minimum 120 Lumen per watt, complete with driver, including three core copper flexible wire of size 0.75 Sqmm for connection from street light fitting to OH line or junction box, fixing accessories and complete all as specified and directed. |
| 41 | S&F in repair LED driver for 45W to 60W LED street light fittings complete all as specified and as directed. |
| 42 | Supply and fix in repairs thermoplastic cable entry junction boxes of size 250 x 200 x 105 mm and IP-65 protection level with metric knock out fixed on poles with MS clamps, nuts, bolts and washers including MCB SPN, 6-32 amps, 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc., separate (detachable) gland plate, bakelite connector 4 way 20 amp, dust and vermin proof, front door opening with hinges and locking arrangement, complete all as specified and as directed. |
| 43 | Supply and fix in repair bracket for street light fittings made out of 32 mm dia GI pipe of light grade 1.5 m long each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 30 x 5 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fitting including taking down old unserviceable bracket of any shape and size all as specified and as directed. |
| 44 | M&L for preparing surfaces of electric poles of any type of following sizes including MS cross arms, MS clamps, street light brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of primer and two coat of aluminium paint completely, alternate layer of yellow and black paint of 150 mm strip at the bottom of pole 1.5 mtr above coping with synthetic enamel paint all as specified and as directed.(a) Height of rail /tubular poles exceeding 7.5 Mtrs upto 11 Mtrs above ground level. |
| 45 | All as per item No. 44 but height of steel tubular poles 7.5 Mtrs above ground level complete all as specified and as directed. |
| 46 | M&L for preparing surfaces of electric poles of RCC type of any sizes including MS cross arms, MS clamps, street light brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of primer and two coat of weather proof paint completely and alternate layer of yellow and black synthetic enamelled paint of 150 mm strips at the bottom of pole 1.5 mtr above coping all as specified and as directed. |
| 47 | M&L for preparing surfaces of electric TWO pole Structures of any make and height of pole up to 10 Mtrs above ground level including MS cross arms, AB Switch pipe, DO Fuse assembly, MS clamps, brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint completely as directed. |
| 48 | All as per item No. 47 but electric Four Pole Structures complete all as specified and as directed. |
| 49 | M&L for writing pole No. with letters of size 25 mm height on pole/ plate with Black synthetic enamelled paint complete all as specified and directed. |
| 50 | M&L for Spray painting to existing LT Panel of any capacity / size / type including mounting angle with two coats of approved colour synthetic enamel paint complete including dusting, cleaning of existing dust before applying synthetic enamel paint and writing feeder name with approved colour synthetic enamel paint complete all as specified and directed. |
| 51 | Supply, erecting & fixing in replacement of steel tubular swaged pole complete with base plate, pole cap, nut bolt washer etc type 410 SP-31 (9.00 meters long) swaged poles conforming to IS 2713 (Part-I to III) 1980 all as specified including two coats of black bitumen paint through out internally and externally upto planting depth and applying two coats of aluminum paint over one coat of red oxide primer (externally) and Numbering of poles as directed including excavation /earth work, PCC 1:4:8 type D-2 using 40mm aggregate for pole foundations of size 600x600x1500mm height upto ground level and using PCC 1:2:4 B-1 for coping with size 450x450x300mm including necessary formwork complete with including taking down old unserviceable pole all as specified and as directed. |
| 52 | Materials and labour as in replacement for earthing complete with galvanized earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including GI wire 4.0 mm as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 32 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (a) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor. |
| 53 | Materials and labour as in replacement for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below ground level connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, washers of galvanized iron and connected to main switch/control board upto 7.5m away from the earth electrode including excavation earth work, PCC chamber, RCC cover slab char coal, watering pipe, wire mesh lugs, earth lead protection pipe 40 mm bore, light grade 7.5m long as applicable and as per plate No. 3 of SSR 2009 and all as specified. (a) Excavation and earth work in any type of soil. (b) Drilling of holes in electrode (c) PCC pit in cement concrete (1:2:4) type B-1 (d) 40 mm thick Pre-cast RCC cover with suitable handle. (e) Funnel with watering pipe of GI 20 mm nominal bore ,medium grade & copper lug etc. (f) 40 mm nominal bore medium grade GI protection pipe 7.50 m long for protection of earthing lead. (g) Requisite quantity of charcoal and common salt. (h) Connection to earthing test point and testing on completion. |
| 54 | Supply and fixing in repair retro reflective boards in shape of rectangle of size 1.0 m x1.4 m made out of 2 mm thick stainless steel both side bounded/pasted with high prismatic (iv) sheet mannufactured by avery dennison or 3 M with desired letters/logos designed as directed the board shall be supplied with and including stainless steel frame made out of 25 mm dia pipe in frame around duly welded with and including stainless steel sheet and stainless steel posts of 38 mm dia and full length of 2.20 m one side and 2.8 m other side complete all as specified and directed. ( Note :(i) Rate for fixing of boards with PCC 1:2:4 type B2 filling of size 45x45x60 cm to be incl in unit rate. (ii) The board should be written description as direction given by Engineer-in-Charge) |
| 55 | M&L for Loose filling with aggregates of gauge 20 mm crushed stone back colour suitable for spreading in electrical sub stn after preparation site by removing all type of debris, removing unwanted soil, and spreading lime powder beneath the aggregate all as directed complete all as specified and as directed. |
| 56 | Supply and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, 2.5 sqmm 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire complete all as specified and as directed. |
| 57 | Supply and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, 4 sqmm 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire complete all as specified and as directed. |
| 58 | Supply and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, 6 sqmm 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire complete all as specified and as directed. |
| 59 | Supply and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, 10 sqmm 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire complete all as specified and as directed. |
| 60 | S & F in replacement 1100 Volts grade Copper conductor, PVC insulated, round sheathed (flexible), industrial cable, 1.5 sqmm 3 corecomplete all as specified and as directed. |
| 61 | Supply and fixing in replacement LED flood light 200 watt (Warm white / Cool white) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete with taking down old unserviceable flood light complete all as specified and directed. |
| 62 | Supply and fixing in replacement LED flood light 100 watt (Warm white / Cool white) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete with taking down old unserviceable flood light complete all as specified and directed. |
| 63 | S&F in replacement ONLOAD Changeover switch 400 Amps, 4 Pole, 415 V in sheet steel enclosure suitable for fixing on wall at existing position, including with all incoming and outgoing connection with cable lugs, washers, nutbolts and accessories complete with taking down old unserviceable changeover switch all as specified and directed. |
| 64 | S&F in replacement ONLOAD Changeover switch 320 Amps, 4 Pole, 415 V in sheet steel enclosure suitable for fixing on wall at existing position, including with all incoming and outgoing connection with cable lugs, washers, nutbolts and accessories complete with taking down old unserviceable changeover switch all as specified and directed. |
| 65 | S&F in replacement ONLOAD Changeover switch 200 Amps, 4 Pole, 415 V in sheet steel enclosure suitable for fixing on wall at existing position, including with all incoming and outgoing connection with cable lugs, washers, nutbolts and accessories complete with taking down old unserviceable changeover switch all as specified and directed. |
| 66 | S&F in replacement ONLOAD Changeover switch 100 Amps, 4 Pole, 415 V in sheet steel enclosure suitable for fixing on wall at existing position, including with all incoming and outgoing connection with cable lugs, washers, nutbolts and accessories complete with taking down old unserviceable changeover switch all as specified and directed. |
| 67 | S&F in replacement ONLOAD Changeover switch 63 Amps, 4 Pole, 415 V in sheet steel enclosure suitable for fixing on wall at existing position, including with all incoming and outgoing connection with cable lugs, washers, nutbolts and accessories complete with taking down old unserviceable changeover switch all as specified and directed. |
| 68 | Supply, fixing and testing in replacement of Automatic Street light Timer Switch using combination of NATURE SWITCH for automatic switching of street lights based on LUX level of natural light consisting with Sensor (Natural Switch) along with suitable power contractor, MCB and support terminals should be enclosed in pole/ wall mountable SMC enclosure made out of Rust proof, Electric shock proof, termite proof and FR grade SMC junction Box conforming to IP 54 protection of capacity 12 KW 3 phase, current range 40 Amps, 4 wire (3 separate power contactor) including all accessories and fixing arrangement all as specified and directed. |
| 69 | Supply and installation, testing & commissioning self-supporting totally enclosed factory fabricated LT bus Each bar panel box made out of 3.15mm thick MS sheet with projected globe roof for rain water protection, dust and vermin proof hinged double shutter doors with neoprene rubber gasket epoxy powder coated including danger plate, earth strip, ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts, and washers etc outdoor type cubicle panel board suitable for 3 Feeder phase 4 wire 415 volt 50 HZ and 40 mm x 40 mm x 6 mm angle iron frame, weather proof ventilated with locking arrangement incl of PCC pedestal, accommodate and consisting of the following items :-(i) Aluminium bus-bar 600 Amps, supported with suitable size Porcelain stand lock with suitable size brass nut, bolts and washers with heat shrinkable colour coded PVC sleeving for 3 phase & neutral . - 01 Set (ii) MCCB with Adjustable type release, 4 pole, 400 Amps, 36 KA, 415 Volts, 50 Hz Adjustable - 01 No. |
| 70 | Supply and installation, testing & commissioning self-supporting totally enclosed factory fabricated LT bus Each bar panel box made out of 3.15mm thick MS sheet with projected globe roof for rain water protection, dust and vermin proof hinged double shutter doors with neoprene rubber gasket epoxy powder coated including danger plate, earth strip, ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts, and washers etc outdoor type cubicle panel board suitable for 3 Feeder phase 4 wire 415 volt 50 HZ and 40 mm x 40 mm x 6 mm angle iron frame, weather proof ventilated with locking arrangement incl of PCC pedestal, accommodate and consisting of the following items :-(i) Aluminium bus-bar 400 Amps, supported with suitable size Porcelain stand lock with suitable size brass nut, bolts and washers with heat shrinkable colour coded PVC sleeving for 3 phase & neutral . - 01 Set |
| 71 | Supply and installation, testing & commissioning self-supporting totally enclosed factory fabricated LT bus Each bar panel box made out of 3.15mm thick MS sheet with projected globe roof for rain water protection, dust and vermin proof hinged double shutter doors with neoprene rubber gasket epoxy powder coated including danger plate, earth strip, ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts, and washers etc outdoor type cubicle panel board suitable for 3 Feeder phase 4 wire 415 volt 50 HZ and 40 mm x 40 mm x 6 mm angle iron frame, weather proof ventilated with locking arrangement incl of PCC pedestal, accommodate and consisting of the following items :-(i) Aluminium bus-bar 200 Amps, supported with suitable size Porcelain stand lock with suitable size brass nut, bolts and washers with heat shrinkable colour coded PVC sleeving for 3 phase & neutral . - 01 Set (ii) MCCB with Adjustable type release, 4 pole, 100 Amps, 25 KA, 415 Volts, 50 Hz Adjustable - 01 No. |
| 72 | M&L for drilling suitable dia horizontal bore holes for insertion/ laying of upto 110mm bore HDPE pipe/GI pipe of any description below/under existing road surfaces/apron /floors etc with using mechanical and / or manual devices as required at site including making good the disturbed surfaces to match with the existing strata after laying pipes complete all as specified and directed. (NOTE : (i) Pipes shall be laid minimum 60 cm below/under existing road surfaces/ apron /floors etc). (ii) Equipment, tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor without any extra cost to the Govt. |
| 73 | Supplying and fixing in replacement of HDPE Pipe, 90 mm bore (PN 10), suitable for insertion in horizontal boring for protection of cable / croossing of cable, complete all as specified and directed. |
| 74 | Supply and fixing in replacement of Contactor of type MU-2P series (rating 16 A / 25A / 40A) suitable for existing Automatic Street light Timer Switch complete with taking down old unserviceable Contactor all as specified and as directed. |
| 75 | Supply and fixing in replacement of Contactor of Freedom series, 3 pole (rating 18 A / 25A / 40A) suitable for existing Automatic Street light Timer Switch complete with taking down old unserviceable Contactor all as specified and as directed. |
| 76 | Cleaning of sub station area by uprooting all types vegitation, shrubs, weeds, saplings and creepers of unwanted trees complete with the help of spade, axes, crowbars, by chemical spraying and other mechanical means after taking necessary electrical shutdown from concerned incharge of various sub stns of Military Stn Kamptee complete all as specified and as directed. |
| 77 | Trimming of tree branches touching of Over head Elecctrical Lines upto 2.5 mtr distance from conductors after taking necessary shutdown from concerned incharge all as directed . (Note : Space between two poles will be measured as distance in RM irrespective of nos of conductors). |
| 78 | Supply and fixing in repair of smart integrated 36 Watt Smart Bright, All in one Solar Street Light including suitable bracket for hanging on existing pole / wall, with Infra Red Remote, with built in mono crystalline panel, Lithium ferro phospate (Lite PO 4) Battery , MPPT charge controller and PIR sensor with colour teperature 6000-6500 K, including nuts, bolts and washers etc, complete all as specified and directed. |
| 79 | Supply and fixing of smart integrated 36/40 Watt Smart Bright, All in one Solar Street Light including galvanized steel pole (6 Mtr pole height) with suitable bracket for hanging, with Infra Red Remote, with built in mono crystalline panel, Lithium ferro phospate (Lite PO 4) Battery , MPPT charge controller and PIR sensor with colour teperature 6000-6500 K, including nuts, bolts, washers, excavation /earth work, PCC 1:4:8 type D-2 using 40mm aggregate for pole foundations of suitable size recommended by the manufacturer and using PCC 1:2:4 B-1 for coping with suitable of size including necessary formwork etc, complete all as specified and directed. |
| 80 | Supply and fixing of smart integrated 30 Watt Smart Bright, All in one Solar Street Light, including suitable hanging bracket, Overcharged & deep discharge protection for battery, MPPT solar charge controller, LiFeP04 lithium Ferro Phosphate battery, maintenance free system, inbuilt BMS system, IP-65, lumen output ≥ 1500 Lm, Colour temp 5700K, Surge protection 5 KV, 50000 burning hrs (min), including nuts, bolts, washers, complete all as specified and directed. |
| 81 | Supply and fix of Tiranga Led Rope Light Indian Tricolor Strip Light (Orange + White + Green) Colour in Single Strip | Independence Day/Republic Day Rope Light for complete 9 meter pole (SP-31), Plug and Play Waterproof IP65 Strip Light, Complete with driver and all fixing arrangements, complete all as specified and directed. |
| 82 | Supply and fixing of 3M Scotchlite Reflective Tape of width 50 mm, water proof, for alternate layer of yellow and black / red tape 300 mm from bottom of pole upto 1.5 mtr above, compete all as specified and directed. |
| 83 | M&L for replacement of PCC coping of poles any type size not less than (0.45x0.45x0.45m) with plain cement concrete (1:3:6) type C1 using 20mm graded coarse stone aggregate, concrete base work, complete all as specified and directed. |
| 84 | Material and labour for cable route indicator made out of PCC (1:2:4) type B1 of size 60cm x 15cm x 5cm thick grouted in PCC (1:2:4) type B1 pillar fo size 30 cm x 30 x 30 cm in ground with and including necessary foam work and making on board MES LT Cable (1100 Volt) with arrow indicating cable path (marking shall be engraved and colour painted), complete all as specified and directed. |
| 85 | Supply, installation, test and commissioning of LT Distribution Panel (CPRI Approved) cubicle type IP-65, Outdoor type conforming to IS 5039 of 1983 factory fabricated prewired, outdoor cubicle type, vermin proof, dust proof, fixed on 50x50x5mm MS angle iron frame fixed 600mm above ground level and 400mm below the ground level grouted in and including PCC 1:3:6 type C1 (using 20mm grade stone aggregate) and plane made out of 3.00 mm thick CRCA sheet for both outer shell and 2.00mm thick for inner shell both side open able supported on and including ISMC 75 X 40mm powder coated steel frame and totally powder coated with epoxy RAL 7032 siemen grey colour after seven tank phosphating treatment from inside and outside with locking arrangement, front and back opening type and fixing arrangement i.e nuts, bolts, washers, clamps etc, with naturally air cooled epoxy insulated aluminium busbar TPN with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoming and outgoing with sufficient working space inside complete, all control cables shall be of 2.5 Sqmm copper multi stranded conductors and shall be properly bunched with suitable size binding materials , ferruled for proper identification of colour codes and crimped with adequate size of lugs also to accommodate, fixing 2 Nos danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and consisting of the following items, including taking down the old unserviceable LT Panel/feeder pillar of any size/ any type, all as specified and as directed. Contd.../- Please Enable Macros to View BoQ information |
| 86 | Supply, installation, test and commissioning of LT Distribution Panel (CPRI Approved) cubicle type IP-65, Outdoor type conforming to IS 5039 of 1983 factory fabricated prewired, outdoor cubicle type, vermin proof, dust proof, fixed on 50x50x5mm MS angle iron frame fixed 600mm above ground level and 400mm below the ground level grouted in and including PCC 1:3:6 type C1 (using 20mm grade stone aggregate) and plane made out of 3.00 mm thick CRCA sheet for both outer shell and 2.00mm thick for inner shell both side open able supported on and including ISMC 75 X 40mm powder coated steel frame and totally powder coated with epoxy RAL 7032 siemen grey colour after seven tank phosphating treatment from inside and outside with locking arrangement, front and back opening type and fixing arrangement i.e nuts, bolts, washers, clamps etc, with naturally air cooled epoxy insulated aluminium busbar TPN with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoming and outgoing with sufficient working space inside complete, all control cables shall be of 2.5 Sqmm copper multi stranded conductors and shall be properly bunched with suitable size binding materials , ferruled for proper identification of colour codes and crimped with adequate size of lugs also to accommodate, fixing 2 Nos danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and consisting of the following items, including taking down the old unserviceable LT Panel/feeder pillar of any size/ any type, all as specified and as directed. Contd.../- Please Enable Macros to View BoQ information |