| 1 | NS Item |
| 2 | S/E of junction cover for octagonal poles made outof fiber sheet of size 0.67 feet x 1.5 feet (approx.) or as required at site, complete and fitting of cover with poles using transparent cello tape etc. complete in all respect |
| 3 | Supply and erection of double overhang GalvanizedIron Bracket having 125 mm dia B class canopy 0.6 mtr long and arm of length 1.5 mtr on each side made out of 50 mm dia B class GI Pipe making an angle of 15 degree with horizontal plane and bracing of 1.35 mtr long made out of 25 mm dia GI Pipe. The Bracket should be suitable for fixing of LED Street Light Fittings on 8 Mtr to 10 Mtr long octagonal poles. The cost is inclusive of all the labour and material required to complete the work up to the entire satisfaction of E-I-C of the work and as per drawing. |
| 4 | Repair charges of LED street light /Flood light pointsfrom 225 watt to 400 watt installed in 9 mtr/11 mtr. long PCC/ STP poles/High Mast. ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e.Driver/SPD/PCB/PVC tape/roll/screw etc, arranging of TandP i.e hydraulic ladder/ aluminum ladder, safety belt, safety shoes etc.) on various sectors / master roads complete in all respect up to the entire satisfaction of engineer in charge of work. |
| 5 | S/E of FRLS PVC insulated and round sheathed 2.5Sqmm x 3 core, bright annealed copper conductor heavy duty industrial flexible cable for voltage grade 1100 volts confirming to IS: 694-2010 complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. Make: Grandlay/Polycab/Havells. |
| 6 | 120 Watt LED street light fittings |
| 7 | S/E of 63 Amps connection plate for incoming andoutgoing cabling in existing Panel/High Mast/pole/bracket/pipe to be fitted with connector fixed on Bakelite sheet complete with nut and bolts. |
| 8 | Repair charges of LED street light / Flood light points from 90 watt to 200 watt installed in 6 mtr /11 mtr. long PCC/ STP poles/High Mast. ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e. Driver/SPD/PCB/PVC tape/roll/screw etc, arranging of TandP i.e hydraulic ladder/ aluminum ladder, safety belt, safety shoes etc.) on various sectors / master roads complete in all respect up to the entire satisfaction of engineer in charge of work. |
| 9 | Trenchless horizontal boring 1 M below ground levelfor laying of underground HDPE pipe, including the cost of HDPE pipe of size 63/50 mm outer dia/inner dia. complete in all respect up to the entire satisfaction of Engineer-in-charge. Make: Rex, Gemni, Dura-Rex |
| 10 | S/Eof 2.5 Sqmm x 3 core (Unarmd.) PVC insulatedand sheathed Aluminium conductor service cable 1100 volts, having Single Solid Aluminium conductor in each core as per IS:694 complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. Make: Polycab/ Havells/ Grandlay |
| 11 | Repair charges of LED street light and Flood lightspoints from 45 watt to 72watt LED installed on 9 mtr./11 mtr. long PCC / STP poles/High Mast, ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e. Driver/SPD/PCB/PVC tape/roll/screw etc, arranging of TandP i.e hydraulic ladder/ aluminum ladder, safety belt, safety shoes etc.) on various sectors / master roads complete in all respect up to the entire satisfaction of engineer in charge |
| 12 | Supply and erection of single overhang Galvanized Iron Bracket having 125 mm dia B class canopy 0.6 mtr longand arm of length 1.5 mtr made out of 50 mm dia B class GI Pipe making an angle of 15 degree with horizontal plane and bracing of 1.35 mtr long made out of 25 mm dia GI Pipe. The Bracket should be suitable for fixing of LED Street Light Fittings on 8 Mtr to 10 Mtr long octagonal poles. The cost is inclusive of all the labour and material required to complete the work up to the entire satisfaction of E-I-C of the work and as per drawing. |
| 13 | S/E of 10 Sqmm single core copper, PVC insulated and sheathed with XLPE insulation and Flame Retardant Lead Free (FRI LF) confirming to IS 694-2010 with bright annealed electrolytic grade conductors of 1100 voltage grade/ 1100 volts complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 14 | S/E of Prodigy type in-built L.T. C. T. meter of (40- 200 amps), 3-phase 415 Volts rating suitable for 3-phase 4 wire system of make Secure, Genus or other make pproved by the UHBVNL. This meter is to be fixed in M.S. meter box and wiring done accordingly complete including all patty material i.e. M-Seal, Nuts-Bolts, thimbles etc. Meter reading taken monthly by the meter reading company and after depositing the meter testing fee by him and it will be refunded on production of receipt received from UHBVNL. |
| 15 | Repair charges of sodium street light points / Flood lights 150/250/400 Watt installed in 9 mtr /11 mtr long PCC/ STP poles/High Mast ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e.chock/lamp/ballast/capacitor/lamp holder/ PVC tape roll/screw etc. arranging of TandP i.e. Hydraulic ladder/Aluminum Ladder, safety shoes/safety etc.) on various sectors / master roads complete in all respect up to the entire satisfaction of engineer in charge of work. |
| 16 | HSR Item |
| 17 | 24.4.8.7-STREET LIGHT 8.7. Supply and erectionof Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 9 Metre Long pole with top dia 100 mm and bottom 200 mm with base plate of size 350 x 350 x 20 mm. |
| 18 | 24.14.17-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 17. 10 Sq mm 4 core (UnArm.) |
| 19 | 24.13.24-LT CABLES (Aluminium Conductor,Armoured and Unarmoured) PROVIDING& ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUNDALUMINIUM CONDUCTOR UNDERGROUND CABLELOOSE IN EXISTING PIPE OR TRENCHES COMPLETE INALL RESPECT WITH NECESSARY CONNECTION UPTOTHE ENTIRE SATISFACTION OF ENGINEER IN CHARGEOF THE WORK 24. 16 Sq mm 4 core (Arm.) |
| 20 | 24.13.32-LT CABLES (Aluminium Conductor,Armoured and Unarmoured) PROVIDING& ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUNDALUMINIUM CONDUCTOR UNDERGROUND CABLELOOSE IN EXISTING PIPE OR TRENCHES COMPLETE INALL RESPECT WITH NECESSARY CONNECTION UPTOTHE ENTIRE SATISFACTION OF ENGINEER IN CHARGEOF THE WORK 32. 25 Sq mm 4 core (Arm.) |
| 21 | 23.22.5.1-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole |
| 22 | 24.5.2.3-MISCELLANEOUS ITEMS 2.3. S/E markdouble walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia |
| 23 | 23.27.3-Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 3. M.S. pedestal of size 750 mm wide , 1200 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 m below ground level . 0 0 |
| 24 | 23.22.5.2-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 5.2. Supply anderection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Single Pole |
| 25 | 3.22.1.3-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole onexisting wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-incharge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA Please Enable Macros to View BoQ information |