| 1 | Shifting / Transporting repairable summer appliances such as Window type AC / Split AC of single phase from various locations to contractor's workshop for checking, repair & replacement of spares including dismantaling of unserviceable/sizing/burn compressor unit, re fixing/ jointing the compressor, discharge suction line with parts like capillary tubes & filter, by brazing ,Checking any leakage in system (i.e compressor and condensor) and making good by servicing, flushing/vacum the whole system, cleaning of condensor etc for 1.5TR to 2TR ACs complete all as specified and as directed and return back the same after repairs in serviceable condition and refixing testing the same in the existing location Noted :- Spare parts shall be mearsured & paid separately under relevant items) |
| 2 | All as per item no-01( here in before) but water cooler of capacity 40 to 80 liters complete all as specified and as directed by engineer in charge. |
| 3 | All as per item no-01 (here in before) but Refrigerator of capacity upto 320 liters complete all as specified and as directed by engineer in charge. |
| 4 | All as per item no-01 (here in before) but Deep Freezer of capacity upto 320 liters complete all as specified and as directed by engineer in charge. |
| 5 | Supply only rubber grommet with sealed compressor for the window reciprocating Compressor/ Split AC of capacity 1.5 ton ,complete all as specified and as directed by Engr in charge . Make compressor - OEM/Emerson Cliamate Technology / Tecomseh/Carrier.) |
| 6 | Supply only rubber grommet with sealed compressor for the window rotary Compressor/ Split AC of capacity 1.5 ton ,complete all as specified and as directed by Engr in charge .Make compressor - OEM/Emerson Cliamate Technology / Tecomseh/LG/Carrier ) |
| 7 | Supply only rubber grommet with sealed compressor for the window reciprocating Compressor/ Split AC of capacity 2 ton ,complete all as specified and as directed by Engr in charge .Make compressor - OEM/Emerson Cliamate Technology / Tecomseh/Carrier.) |
| 8 | Supply only rubber grommet with sealed compressor in repair for the window rotary Compressor/ Split AC of capacity 2 ton ,complete all as specified and as directed by Engr in charge .Make compressor -OEM/ Emerson Cliamate Technology / Tecomseh/LG/Carrier ) |
| 9 | Supply only Capillary Tube (copper) suitable for window type AC/split AC upto 2 Ton complete all as specified and as directed. |
| 10 | Supply only Filter strainer (copper) suitable for window type AC/split AC,complete all as specified and as directed . |
| 11 | Supply only split out door fins type copper condensor of capacity 2 Ton ,complete all as specified and as directed. |
| 12 | Supply only Running capacitor 45/50 mfd + 06 mfd, complete all as specified and as directed. Make: Sarda/Tibcon/OEM. |
| 13 | Supply only Running capacitor 50 mfd + 4 mfd,dual cap, complete all as specified and as directed. Make: Sarda/Tibcon/OEM. |
| 14 | Supply only capacitor 60 +6 mfd, complete all as specified and as directed. Make: Sarda/Tibcon/OEM. |
| 15 | Supply only capacitor 3.15 mfd, complete all as specified and as directed. Make: Sarda/Tibcon/OEM. |
| 16 | Supply only Contactor relay for split type AC complete all as specified and as directed Make:L&T/ Indo Asian/OEM |
| 17 | Supply only blower Fan (PVC) for split type AC upto 2 Ton Capacity, complete all as specified and as directed .Make OEM/Carrier/ Usha/ Videocon/ Samsung. |
| 18 | Supply only inner Blower Fan for window AC complete all as specified and as directed .Make: OEM/Carrier/ Videocon/ Samsung. |
| 19 | Supply only indoor fan motor for window type AC upto 2 ton capacity complete all as specified and as directed . |
| 20 | Supply only outdoor fan motor for Non inverter split type AC upto 2 ton capacity complete all as specified and as directed . |
| 21 | Supply only outdoor fan motor for inverter split type AC upto 2 ton capacity complete all as specified and as directed . |
| 22 | Supply only indoor fan motor for inverter split type AC upto 2 ton capacity complete all as specified and as directed . |
| 23 | Supply and fix in repairs PCB Board for split type AC upto 2 ton complete all as specified and as directed.Make:-OEM/LG/Voltas/carrier /samsang /Videocon |
| 24 | Taking down carefully u/s indoor electronic type PCB at existing location repair and refixing split type AC of capacity 1.5 to 2.0 Ton complete all as specified and as directed by Engr-in- Charge. |
| 25 | Supply only 2.5 mfd capacitor for indoor split unit complete all as specified and as directed (Make : OEM/Universal/Sarada) |
| 26 | Supply only Swing motor of lower shutter complete all as specified and as directed . |
| 27 | S & F in repairs Display board for upto 2 Ton AC complete all as specified and as directed |
| 28 | S & F in repairs Sensor for indoor unit complete all as specified and as directed |
| 29 | S & F in repairs 1/4\\" (Brass) service line charging valve complete all as specified and as directed |
| 30 | S & F in repairs 1/4\\" dia copper pipe complete all as specified and as directed |
| 31 | S & F in repairs 1/2\\" dia copper pipe complete all as specified and as directed |
| 32 | S & F in repairs 5/8\\" dia copper pipe complete all as specified and as directed |
| 33 | S & F in repairs 1/2\\" dia (Brass) suction line valve, complete all as specified and as directed |
| 34 | S & F in repairs 1/4\\" dia Flare nut, complete all as specified and as directed |
| 35 | S & F in repairs 5/8\\" dia Flare nut, complete all as specified and as directed |
| 36 | S & F repairs, drain pipe suitable for upto 2 Ton cap split Ac.complete alll as specified and as directed. |
| 37 | S & F in repairs, insulation tube (size 1/4\\"/1/2\\",5/8\\") for split type AC to insulation copper pipe complete all as specified and as directed. |
| 38 | S & F in repairs, Metal plug top 20 Amps,3pin for split type AC/window AC complete all as specified and directed. |
| 39 | S & F in repairs, Metal socket plug 20Amps,3pin for split type AC/window AC complete all as specified and as directed. |
| 40 | S & F in repairs, MCB DP 20 to 32Amps, C curve complete all as specified and as directed. |
| 41 | Dismantling of blower fan motor for window type AC 1.5/2.0 ton , cutting burnt coils and taking out from the stator, cleaning the slots using primer, rewinding using super enamelled copper winding wire of same size and gauge as existing including insulation materials, replacement of bush (front and rear) made out of gun metal or ball bearing as existing and re-assembling all accessories and testing complete all as specified and as directed. |
| 42 | All as per item no- 41 (here in before) but split AC out door unit 1.5/2.0 ton complete all as specified and as directed. |
| 43 | Attending complaints of any nature for defective AC of various capacity of split/window type AC and rectification of defects and necessary repairing and fixing at site and replacing spare as requried for smooth functioning of the AC all as directed by EIC . Note:- Spare parts shall be measured and paid separetly. |
| 44 | Attending complaints only of leakage of refrigerant R-22 for split type AC and rectification on site and charging of refrigerant in system all as directied by Engineer in charge . |
| 45 | Attending complaints only of leakage of refrigerant R-32 for split type AC and rectification on site and charging of refrigerant in system all as directied by Engineer in charge . |
| 46 | Attending complaints only of leakage of refrigerant R-410a for split type AC and rectification on site and charging of refrigerant in system all as directied by Engineer in charge . |
| 47 | Supply and charging of refrigant R-134 complete all as specified and as directed. |
| 48 | Supply and charging of refrigant R-22 complete all as specified and as directed. |
| 49 | Dismantling/Shifting and refixing of split type AC of capacity 1.5 to 2.0 Ton including repositioning of mounting arrangement for indoor / outdoor unit and gas charging of required quantity in the unit complete all as specified and directed by Engr-in- Charge.(Note:-Refrigerants R-22 & copper pipe shall be measured and paid separately |
| 50 | Supply & fix in repairs remote control for split/window AC complete all as specified and directed by Engr-in- Charge. |
| 51 | Supply and fix in repairs metal enclosure box single pole and neutral two pin and earth socket with MCB complete all as specified and directed by Engr-in- Charge . |
| 52 | Attending complaints of any nature for defective water cooler of any capacity and rectification of defects including servicing and necessary repairing and fixing at site and replacing spare as requried for smooth functioning of the water cooler complete all as specified and as directed by Engr-in-Charge. Note:- Spare parts shall be measured and paid separetly. |
| 53 | All as per item no-52 (here in before) but Refrigerator of any capacity, complete all as specified and as directed by engineer in charge. |
| 54 | All as per item no-52 (here in before) but Deep Freezer, complete all as specified and as directed by engineer in charge. |
| 55 | Dismantling of blower fan motor, cutting burnt coils and taking out from the stator, cleaning the slots using primer, rewinding using super enamelled copper winding wire of same size and gauge as existing including insulation materials, replacement of bush (front and rear) made out of gun metal or ball bearing as existing and re-assembling all accessories and testing for the water cooler/ Deep Freezer complete all as specified and as directed . |
| 56 | Supply only Blower motor for Deep Freezer of capacity 320 liters, complete all as specified and as directed by engineer in charge. |
| 57 | Supply only Deep Freezer Of capacity 320 Liters, Compressor complete all as specified and as directed by Engr-In-Charge . |
| 58 | All as per item no-57 (here in before) but Refrigerator of capacity 315 liters, complete all as specified and as directed by engineer in charge. |
| 59 | Supply only filter strainer (copper) for Refrigerator /water cooler/deep freezer complete all as specified and as directed by engineer in charge. |
| 60 | Supply and fix ICE-Chamber / Cooling coil upto 310 ltr refrigerator, complete all as specified and as directed by engineer in charge. |
| 61 | Supply only copper capillary pipe 10 feet long for refrigerator of capacity 315 ltrs complete all as specified and as directed by engineer in charge. |
| 62 | Supply only copper capillary pipe 20 feet long for water cooler/deep freezer complete all as specified and as directed by engineer in charge. |
| 63 | Supply only timer suitable for various capacity of refrigator complete all as specified and as directed by engineer in charge. |
| 64 | Supply only open type relay with over load protector complete all as specified and as directed by engineer in charge.Make : OEM/Samsung/Whirl pool. |
| 65 | Supply only thermostate long tail auto defrost for water cooler/ deep freezer complete all as specified and as directed by engineer in charge. |
| 66 | Supply only Bimetal relay complete all as specified and as directed by engineer in charge. |
| 67 | Supply only Heating element complete all as specified and as directed by engineer in charge. |
| 68 | Supply only frost free fan motor complete all as specified and as directed by engineer in charge. |
| 69 | Supply and fix condenser coil upto 310 Ltr refrigerator complete all as specified and as directed by engineering in charge |
| 70 | Supply only starting relay suitable for 0.50/1HP compressor motor complete all as specified and as directed by engineer in charge. |
| 71 | Supply only thermostate for refrigerator complete all as specified and as directed by engineer in charge. |
| 72 | Supply only PCB for refrigerator complete all as specified and as directed by engineer in charge. |
| 73 | Taking out voltage stabilizer by disconnecting existing cable for u/s stabilizer of upto 5 KVA capacity including repairing / replacement of push on switch, relay transistor, diode, voltmereter, indicator lamp,high low cutout, MCB, complete parts along with testing and commissioning and transportation charges from site to workshop complete all as specified and as directed by engineer in charge. |
| 74 | Supply and fix in repairs of wall mounted single phase AC Voltage stabiliser 140 to 280 volt of capacity upto 05 KVA complete all as specified and as directed by engineer in charge. |
| 75 | Supply and fix in repairs PCB Board for outdoor unit upto 2 ton inverter type Split AC complete all as specified and as directed.Make:-OEM/LG/Voltas/carrier /samsang /Videocon |
| 76 | Supply and fix in repairs PCB Board for indoor unit upto 2 ton inverter type Split AC complete all as specified and as directed.Make:-OEM/LG/Voltas/carrier /samsang /Videocon |
| 77 | S&F in replacement of Indoor unit including outer body, fan motor, filter, copper cooling coil, blower, display, thermostate, sensor & PCB suitable for 1.5/2 TR split type AC unit Non inverter type including testing all as specified & directed by Engr-in-Charge. |
| 78 | S&F in replacement of Indoor unit including outer body, fan motor, filter, copper cooling coil, blower, display, thermostate, sensor & PCB suitable for 1.5/2 TR split type AC unit inverter type including testing all as specified & directed by Engr-in-Charge. |
| 79 | Supply and fix in repairs of indoor cooling coil made up of copper tubing and copper/aluminium cooling fins all as per sample and as suitable for 1.5/2 Ton capacity split type AC all as specified and directed by engr in charge. |
| 80 | Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas charging as prescribed by manufacturer, leak testing & commissioning of Split type A/C of any type, any capacity, any make complete all as specified and directed by Engr in charge. |
| 81 | M&L for Clear guard Copper preventive coating to protect corrosion of Window/ Split type AC Copper parts like cooling coil ,condencing coil,copper piping complete all as specified and directed by Engr in charge. |
| 82 | Taking out servo type voltage stabilizer for 5 KVA capacity including repairing / replacement of push on switch, relay transistor, condenser, voltmeter, preset , indicator lamp, cutout wherever required complete parts along with testing and commissioning and transportation charges from site to workshop all as specified and as directed. |
| 83 | Matetial and labour for providing sub-main wiring with 4.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 4.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size including cutting chases pinning in making good to facing and pointing in using cement moter 1:3 to the ends with taking down old unserviceable sub main wiring and making good disturbed surface complete all as specified and as directed.Note :(i) Two run of 4.0 Sqmm + one run of 2.5 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit. |
| 84 | Matetial and labour for providing sub-main wiring with 6.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 6.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC casing/caping of suitable size including with taking down old unserviceable sub main wiring and making good disturbed surface complete all as specified and as directed.Note :(i) Two run of 6.0 Sqmm + one run of 4 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit. |
| 85 | Supplying and fixing 1100 volts grade,heavy duty cable with PVC insulated, aluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed, flat or circular of size 2 core x 6 sqmm with IS 694: 2010,complete all as specified and as directed.Make: Richa/Plaza/Havells |
| 86 | Supply & Fix in repairs Outdoor unit stand for split/window AC complete all as specified and directed by Engr-in- Charge. Please Enable Macros to View BoQ information |