| 1 | PART - I - SPECIAL REPAIRS TO COOLING APPLIANCES AGAINST BER AT MTTI |
| 2 | Disconnecting electrical supply from source and taking down split/window type Air Conditioner of any capacity along with voltage stabilizer and all accessories, without damaging other installations, making good disturbed surfaces to match with existing finish, and transporting the same to MES Store Yard GE Avadi, complete all as specified and as directed |
| 3 | Supply, installation, testing and commissioning of Hi-wall split type Air Conditioner of 1.5 TR capacity complete with indoor and outdoor units, cordless remote control unit, inbuilt ionizer and plasma filter for improved indoor air quality, having minimum 5-star rating and EER not less than 3.2 with copper condenser coil; including fixing of GI powder coated brackets (16 SWG) for mounting of outdoor unit with suitable fasteners and grouting, laying of copper refrigerant tubing of suitable sizes (1/4\\" and 1/2\\") with PUF insulation along with all connected accessories, and PVC drain pipe of 20/15 mm dia for indoor unit, complete all as specified and as directed |
| 4 | Supply and fixing of Automatic Voltage Stabilizer suitable for 1.5 TR split Air Conditioner, having input voltage range of 170–270 volts (or as specified), output voltage 230 volts ± 10%, capacity 5 kVA, with high/low voltage cut-off protection, time delay relay, thermal overload protection, complete with all connections, fixing arrangements and testing, complete all as specified and as directed |
| 5 | PART - II - PROVN OF VITRIFIED TILES & ALUMINIUM PARTITION IN CQA (HV) |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and disposing of unserviceable materials outside premises, complete all as specified and as directed. |
| 7 | Demolition of cement concrete (unreinforced) in ground floor or pavings not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed |
| 8 | Material and labour for 100 mm thick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub-base, complete all as specified and as directed. |
| 9 | Material and labour for 25 mm thick cement concrete type B-1 (1:2:4) for flooring, finished even and smooth without using extra cement, complete all as specified and as directed |
| 10 | Material and labour for 40 mm thick cement concrete type B-1 (1:2:4) for flooring, finished even and smooth without using extra cement, complete all as specified and as directed. |
| 11 | Material and labour for vitrified tiles, light shade, 10 mm thick (square/rectangular), polished, area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15 mm thick screed bed in cement mortar (1:4), complete all as specified and as directed. |
| 12 | Material and labour for vitrified tiles, light shade, 10 mm thick (square/rectangular), polished, in vertical surfaces (dado/skirting), to match with tiles laid over, including 10 mm thick backing coat in cement mortar (1:3), complete all as specified and as directed . |
| 13 | Supply and fixing of anodised aluminium powder coated frames (minimum thickness of powder coating 50 microns) for doors, windows and ventilators with one or more rebates including necessary joining cleats for fixing, complete all as specified and as directed. |
| 14 | Supply and fixing of powder coated anodised aluminium partition door shutters, aluminium sections weighing not less than 0.55 kg/m, including necessary joining cleats, glazing clips, rubber neoprene packing, handles (2 Nos per door), hinges, anodised aluminium snap beading, screws, etc., complete all as specified and as directed. |
| 15 | Material and labour for 12 mm thick prelaminated particle board, interior grade, prelaminated on one side with decorative laminate and balancing white laminate on the other side, fixed with screws to aluminium frame shutter, complete all as specified and as directed. |
| 16 | Supply and fixing of 5.5 mm thick sheet glass, ordinary quality, glazing with oil putty in panes exceeding 0.50 sqm, complete all as specified and as directed. |
| 17 | Point wiring on stone/brick masonry wall complete with two 1.5 sqmm single core PVC insulated FRLSH, 1100 volts grade unsheathed cable conforming to IS:694, with multistranded copper conductor, drawn through non-metallic rigid PVC conduit of not less than 20 mm dia concealed in walls, including one 1.5 sqmm FRLSH green earth wire, complete with modular box, all as specified and as directed (for one 3 pin 5 Amp socket on same board). |
| 18 | One switch socket outlet 3 pin 5 Amps on independent board. |
| 19 | Supply and fixing of switch, piano flush type, single pole, 5 Amps, 240 volts, complete all as specified and as directed. |
| 20 | Supply and fixing of socket outlet 2 in 1, 3 pin, 5 Amps, flush type (multi-purpose), complete all as specified and as directed. |
| 21 | Supply and fixing of sheet metal enclosure for DB, double door, flush type, complete with 100 Amps bus-bar, 240 volts single phase, 8 ways, including necessary brick work and plastering to match existing surface, complete all as specified and as directed. |
| 22 | Material and labour for power/sub-main wiring with PVC insulated FRLSH copper conductor, two runs of 6 sqmm single core cable with one 6 sqmm earth wire, drawn through rigid PVC conduit, concealed in walls, complete all as specified and as directed. |
| 23 | Supply and fixing of 240 V, 10 kA ‘B’ curve MCB, single pole, 5–32 Amps, complete with connection, testing and commissioning, complete all as specified and as directed. |
| 24 | Supply and fixing of 240 V, 10 kA ‘B’ curve MCB, SPN, 40–63 Amps, complete with connection, testing and commissioning, complete all as specified and as directed. |
| 25 | Material and labour for PVC conduit of 25 mm internal dia, heavy duty, laid in floor for LAN/telephone cables, complete all as specified and as directed. |
| 26 | Supply and fixing of Telephone/LAN socket RJ45 Cat 6, complete all as specified and as directed. |
| 27 | PART - III - PROVN OF WASH ROOM AT SOUTH POWER HOUSE AND PROVN OF INTERLOCKING TILES AT GR PRASAD HALL AND PROVN OF 2 NOS OF CUBES 2 TON AND 3 TON AT 23 ED AF STN AVADI |
| 28 | Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in hard/ dence soil incl cleaning away all grass vegetation saplings shrubs brushwood undergrowth roots and trees not exceeding 30cm grith and remoiving rubbish upto a distance 50M outside the operiphery of the area under clearance complete all as specified and as directed |
| 29 | Excavation of trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation etc or for sharts, wells cessipts, manholes, pier holes etc 10 Sqm on plan and n exc 1.5m in depth and getting out soft/loose soil. complete all as specified and as directed |
| 30 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregete as in foundation filling and mass concreteing complete all as specified and as directed |
| 31 | Material and labour for Brickwork with flyash bricks using Old size bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and as directed |
| 32 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and as directed |
| 33 | Removing excavated material not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point. complete all as specified and as directed |
| 34 | Rendering 10 mm thick on fair faces of brick work or concrete surfaces complete all as specified and as directed |
| 35 | M&L for 5 mm thick cement plaster in CM 1:4 with WPC rendered over 10 mm thick plaster in CM 1:6 finished even and fair without using extra cement (water proofing compound shall be measured and paid separately.) complete all as specified and as directed |
| 36 | Preparing surface plastered or unplastered on walls and applying three coat of white wash complete all as specified and as directed |
| 37 | M&L for preparation new surface of wall applying two coats of cement based paint over coat of alkaline resistant Primer on external wall surface complete all as specified and directed |
| 38 | Roof trusses (framed) trussed purlins,crane gantries rail and fastering and havy brackets framing (Beam tee angle, chenal or flat sections) including distance pices , cleats etc Fe 410-W(Gde E-250) quality-A complete all as specified and as directed |
| 39 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed |
| 40 | M&L Pre painted galvalume aluminium zinc coating GI based plain steel sheet in ridges 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall,fixed with self tapping screws complete all as specified and as directed |
| 41 | Preparation of new or pervousily untreeated steel surfaces of any descrpition, over 10cm width or girth not other wise described and applying two coats of synthetic enamal paint over a coat of red oxide primer. complete all as specified and as directed |
| 42 | M & L cement concrete 1:3:6, 75 mm thick, type C2, (using 40 mm graded stone aggregate) as in plinth protection/ path etc finished surface even and smooth witout using extra cement. complete all as specified and as directed |
| 43 | M&L broken stone or boulders hardcore of guage not exceeding 63mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a ture surface complete all as specified and as directed |
| 44 | M&L for forming 12mm thick expansion joints filled with pre formed bituminous filler 100mm pth and top 30mm shall be applied wioth primer and sealed with sealing compoubnd Grade \\"B\\" complete all as specified and as directed |
| 45 | Supply only Liquid Water Proofing Compound complete all as specified and as directed |
| 46 | S&F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment of Fe-410-W (Gde-E-250) quality ‘A’ complete all as specified and as directed. |
| 47 | MS screw bolts machine made fitted with washers length nexc 5 cm and dia 16 to 20mm. complete all as specified and as directed |
| 48 | S&F 500 ltr capacity triple layer, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hosited and fixed in position complete all as specified and as directed |
| 49 | S&F Ball vales, high pressure with of PTMT with expoxy caiorted aluminium rod & high desity plastic ball screwed fopr iron pipe of 25mm bore (minium weight 455 gms) and ffix complete all as specifed and directed |
| 50 | S&F 25 mm gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe all as specifed and directed |
| 51 | S&F Unplasticised PVC pipes and fittings of 15mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed |
| 52 | All as per item No.54.00 above but for 20mm bore |
| 53 | S&F Non coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular ) area of each tiles exceeding 0.03 sqm but not exceeding 0.11 sqm in floors etc . set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over 10mm thick screed bed in CM 1:4 complete all as specifed and directed |
| 54 | M&L Glazed ceramic tiles in vertical surface of size 450 x 350x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM ( 1:3 ) all as specified and directed |
| 55 | S&F Vitreous china squatting pan “ Orissa” pattern size 580mm x 440mm white with integral foot rest including 10ltrs capacity PVC flushing cistern (low level with inlet, ball valve float), brackets, flush pipe of polyethylene of low density PVC 32mm dia for low level flushing cistern complete all as specified and as directed. |
| 56 | S&F Vitreous China wash basin (flat back or angle type) of size 550zx400mm including brackets, PTMT waste coupling 32mm and PVC 32mm dia waste pipe including cutting for and pinning in ends of bracket or erecting stands etc. complete all as specified and directed. |
| 57 | S&F Vitreous china urinals, half stall type with PVC waste / flush pipe, complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement grating and union for discharge pipe etc complete all as specified and directed. |
| 58 | S&F tubular towel rail aluminum anodized, 20mm dia D Type 60cm long between flanges all as specified and directed. |
| 59 | S&F in repairs soap dish vitreous china white of size 160x160x90mm fixed to wall all as specified and directed. |
| 60 | S&F fancy type 600 x 450 mm bevelled edges mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screw and cup washers. complete all as specified and as directed |
| 61 | S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and directed. |
| 62 | S&F 15mm dia Bib taps, chromium plated coated copper alloy with crutch or butterfly handle, screwed down , screwed for PVC/iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 63 | S&F 15mm dia stop valve /Angle valve, chromium plated fancy type cast copper alloy, screwed down high pressure with crutch or butterfly handle, screed both ends for PVC /Iron pipes or for unions and fixed of complete all as specified and directed. |
| 64 | S&F 15mm dia pillar taps cast copper, alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered “Hot” or ‘Cold’ with long screed shanks and fly nuts screwed for iron pipe complete all as specified and directed. |
| 65 | S&F PVC Connections 15mm size with PTMT nuts of length 600mm. complete all as specified and as directed |
| 66 | S&F PVC (SWR) pipe 110mm bore PVC (SWR) pipes single socked, in any length with rubber rings joints, laid in trenches or in floors, complete all as specified and directed. |
| 67 | S&F PVC (SWR) pipe 75mm bore PVC (SWR) pipes single socked, in any length with rubber rings joints, laid in trenches or in floors, complete all as specified and directed. |
| 68 | S&F PVC (SWR) pipe 110mm bore PVC (SWR) pipes single socked, in any length with rubber rings joints, fixed on walls, complete all as specified and directed. |
| 69 | S&F 75mm bore PVC (SWR) bends any radius, complete all as specified and directed |
| 70 | S&F 110mm bore PVC (SWR) bends any radius, complete all as specified and directed |
| 71 | S&F PVC (SWR) vent cowl complete all as specified.complete all as specified and as directed |
| 72 | S&F PVC (SWR) dully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed |
| 73 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube of 19 gauge meter cut at two corners and joined by inserting two Nos of 150mm long brackets of 15mmx15mm MS square tube inside the 19mm MS Square tube and suitably screed complete all as specified and as directed. |
| 74 | S&F Factory made solid PVC moulded door shutter with wood free EPS 28 to 30mm thick (Styles) with 2,4 or 6 raised panel design with 2mm hick moulded PVC sheet on front face and 2mm plain colour PVC Sheet on back face, supplying and fixing in frame at site as per specification complete all as specified and as directed |
| 75 | S&F 100mm Butt hinges stainless steel with stainless screw complete all as specified and as directed |
| 76 | S&F aluminum handle 100mm cast type anodized. complete all as specified and as directed |
| 77 | S&F aluminium anodized tower bolt 100mm size complete all as specified and directed |
| 78 | S&F anodized aluminum frame for doors, window ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified (including channels for louver glass) complete all as specified and as directed |
| 79 | S&F 4mm thick figured glass pin headed type and glazing with oil putty in square not exc 0.5sqm in each pane. complete all as specified and as directed |
| 80 | Demolition and breaking up drain pipes, 150mm internal dia (Salt glazed stone ware pipe)including bed & hunching concrete (including removal of debris to a distance not exceeding 50m at a level as directed) and provision of material and labour for new salt glazed stone ware drain pipe 100mm internal dia of grade ’A’, laisd in trenches and set jointed in cement mortor 1:1 complete all as directed. Note:- Provision of Bed and haunching concrete will be measured and and paid separately. complete all as specified and as directed |
| 81 | M&L for DWCPE (SN8) pipes of nominal bore dia 150mm laid and jointed completely with collars all as specified and as directed |
| 82 | Material and labour for concrete bed to SWG/DWCPE pipe line of 150mm bore with PCC (1:3:6) type C2(USING 40MM graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid and tested all as specified and as directed |
| 83 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 25 cm using excavated soil complete all as specified and as directed |
| 84 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required internal dia of pipe 150mm complete all as specified and as directed |
| 85 | Material & labour for precast cement concrete in (1:2:4) type B1(using 20mm garfed stone aggregate) set in cement mortar 1:6as in landings, cover slabs chullah hoods, chajjas, water troughs managers sheles and similar articles with palin face including necessary form work complete all as specified and as directed |
| 86 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required including craking, bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips all complete all as specified and as directed |
| 87 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing the debris off all as specified and directed. |
| 88 | Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregate)as in sub base floor hard standing etc all as specified and directed. |
| 89 | Material & Labour for 50mm thick sand filling and leveling under 60mm thick interlocking paver block.all as specified and directed. |
| 90 | Machine pressed precast concrete interlocking paver block, 60 mm thickness, M-35 grade of any shape and size conforming to IS 15658-2006 all as specified and directed. |
| 91 | M&L RCC M-30 design mix as in Columns, pillars, piers, posts and struts all as specified and directed. |
| 92 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.all as specified and directed. |
| 93 | Point wiring on stone/brick masonry wall complete with two runs of 1.5 sqmm single core PVC insulated FRLSH, 1100 volts grade unsheathed cable conforming to IS:694 with multistranded copper conductor, drawn through and including non-metallic rigid PVC conduit with conduit fittings and accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling/roof trusses, including one run of 1.5 sqmm PVC insulated FRLSH green colour copper conductor as earth continuity conductor connected to common earth dolly, including steel box of required module for modular switches/sockets and regulators, complete all as specified and as directed for (a) one light point controlled by one switch. Note: Cost of terminal box and cutting chases for concealing conduit is deemed to be included in the item rates. |
| 94 | One exhaust fan point controlled by one switch. |
| 95 | One switch socket outlet 3 pin 5 Amps on independent board. |
| 96 | Supply and fixing of switch, piano flush type, single pole, 5 Amps, 240 volts, complete all as specified and as directed. |
| 97 | Supply and fixing of switch socket outlet, 3 pin, 5 Amps, multi-pin, flush type, complete all as specified and as directed. |
| 98 | Supply and fixing of ceiling rose 65 × 50 mm, three terminals, bakelite, surface type, complete all as specified and as directed. |
| 99 | Supply and fixing of MCB DB SPN 4 way, double door, powder coated, 240 volts, AC, 50 Hz, IP43 protected, with provision for double pole MCB as incomer and SP MCBs as outgoing, complete with tinned copper bus bar, neutral link, earth link and connections, complete all as specified and as directed. Note: Incoming and outgoing MCBs shall be measured separately under relevant items. |
| 100 | Supply and fixing of 240 V, 10 kA ‘B’ curve miniature circuit breaker (MCB), single pole, 6 to 32 Amps, in MCB DB, complete with connection, testing and commissioning, complete all as specified and as directed. |
| 101 | Supply and fixing of 240 V, 10 kA ‘B’ curve miniature circuit breaker (MCB), SPN, 20 Amps, in MCB DB, complete with connection, testing and commissioning, complete all as specified and as directed. |
| 102 | Supply and fixing surface/wall mounted LED tube light fitting 20/22 W, batten type, with polycarbonate housing and diffuser, integrated electronic driver, complete with all accessories, suitable for operation on AC single phase 220/230 volts, 50 Hz supply, including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting, complete all as specified and as directed. |
| 103 | Supply and fixing LED bulkhead light fitting 1×9 W / 1×10 W including LED driver, complete with all accessories and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. |
| 104 | Supply and fixing exhaust fan heavy duty 300 mm sweep, 1370 RPM, with louvers, metal body conforming to IS:2312, AC single phase 240 volts, 50 Hz, including provision of two-way PVC connectors, 1 sqmm three core multistranded copper conductor flexible cable from ceiling rose/connector to fan, including earthing and fixing arrangements such as making hole in wall and finishing to match adjoining surface and marking MES number with synthetic enamel paint, complete all as specified and as directed. |
| 105 | Material and labour for earth continuity conductor or main earthing lead fixed on batten or recessed in walls or buried in ground or drawn in conduit or any other situation for loop earthing using 4 mm dia galvanised steel wire, complete all as specified and as directed. |
| 106 | Earthing complete with galvanised iron earth plate electrode 600 mm × 600 mm × 6 mm thick including earthing lead of 4 mm dia GI wire protected by 15 mm dia GI pipe up to a length of 7.5 m, buried vertically not less than 2.25 m below ground level with top edge not less than 1.5 m below ground level, connected with GI/MS bolts, nuts, washers and checknuts, including PCC chamber 1:3:6 type C-1, RCC cover slab 1:2:4 type B-1 reinforced with 8 mm TMT bars at 140 mm c/c both ways, GI watering pipe 20 mm dia with funnel, wire mesh, salt and charcoal, complete including testing, all as specified and as directed. |
| 107 | PART - IV - PROVN OF DEEP FREEZER AND REFRIGERATOR AT CQA (HV) |
| 108 | Supply , installation & commissioning of refrigerator, electric driven (single phase), capacity 185 Litres, double door ,BEE 5, Invertor type star rating including auto voltage stablizer complete all as specified and as directed . |
| 109 | Supply , installation & commissioning of deep freezer hard metal top of capacity 205/210 Litres , Single Phase, having single door Complete all as specified and as directed. |
| 110 | Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90V to 300V with out put voltage stablized at 230v with accuracy of +/- 2.5% and capacity 4KVA all as specified and as directed. |
| 111 | Point wiring on stone/brick masonry wall complete with two 1.5 sqmm single core PVC insulated FRLSH, 1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc, and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly, including modular boxes, frames and cover plates all as specified and directed complete for (a) switch socket outlet 3 pin 5 Amps on independent board. |
| 112 | Supply and fixing modular switch 1 way 6A, 1 module |
| 113 | Supply and fixing modular Socket, 6A - 2/3 pin combined 2 module all as specified and directed. |
| 114 | PART - V - PROVN OF SPLIT AC IN READING ROOM (LIBRARY) |
| 115 | Supply, installation, testing and commissioning of Hi-wall split type Air Conditioner of 1.5 TR capacity complete with indoor and outdoor units, cordless remote control unit, inbuilt ionizer and plasma filter for improved indoor air quality, having minimum 5-star rating and EER not less than 3.2 with copper condenser coil; including fixing of GI powder coated brackets (16 SWG) for mounting of outdoor unit with suitable fasteners and grouting, laying of copper refrigerant tubing of suitable sizes (1/4\\" and 1/2\\") with PUF insulation along with all connected accessories, and PVC drain pipe of 20/15 mm dia for indoor unit, complete all as specified and as directed |
| 116 | Supply and fixing of Automatic Voltage Stabilizer suitable for 1.5 TR split Air Conditioner, having input voltage range of 170–270 volts (or as specified), output voltage 230 volts ± 10%, capacity 5 kVA, with high/low voltage cut-off protection, time delay relay, thermal overload protection, complete with all connections, fixing arrangements and testing, complete all as specified and as directed |
| 117 | Supply and fix 240 V 20 Amps Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 16 Amp capacity complete all as specified and as directed. Supply and fix Water heater storage type, electric, capacity 25 litres, BEE 5 star rated (incl inlet, out let pipes), adjustable thermostat, Efficient long-life copper heating element, Shock-resistant and rust-proof engineering, thermoplastic body, IPX4 waterproof technology, tank designed to withstand 8 bar pressure, tank marine grade glass line coated,PUF insulation, Magnesium anode complete with all fixing arrangements all as specified and directed. Please Enable Macros to View BoQ information |