| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.a) Group C |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.a) Group C |
| 3 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.a) 20 mm |
| 4 | b) 25 mm |
| 5 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required.a) 3 x 1.5 sq.mm |
| 6 | c) 3 x 4 sq.mm |
| 7 | e) 3 x 6 sq.mm |
| 8 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.a) 3 Module (100mmX75mm) |
| 9 | b) 6 Module (200mmX75mm) |
| 10 | c) 8 Module (125mmX125mm) |
| 11 | d) 12 Module (200mmX150mm) |
| 12 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 amp switch |
| 13 | b) 3 pin 5/6 amp socket outlet |
| 14 | c) 15/16 amp switch |
| 15 | d) 6 pin 15/16 amp socket outlet |
| 16 | e) 25A modular SP MCB \\"C\\" curve |
| 17 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.a) 3 Module |
| 18 | b) 6 Module |
| 19 | c) 12 Module |
| 20 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve includingconnections, painting etc. as required. |
| 21 | Supplying and fixing of two module stepped type electronic fan regulator on the existing modular plate switch box i/c connections but excluding modular plate etc as reqd. |
| 22 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single pole |
| 23 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release an terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.a) 100 A, 16 KA, TPMCCB |
| 24 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm)a) 18- 22 watt |
| 25 | b) 36 watt |
| 26 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.)Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm)a) 36watt |
| 27 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.a) 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum) |
| 28 | Supplying installation, testing and commissioning of 1'x4' LED 40watt Surface/pendent Mounting LED Flat panel 1'x4' made of CRCA sheet steel with high efficient LEDs & Glare free opal diffuser, IP20 i/c connection with 1.5sqmm FRLS copper conductor single core cable suitable for 230volt 50Hz AC supply etc as reqd. |
| 29 | Supplying & fixing 400mm sweep wall mounted cabin fan with speed regulator oscilatting type i/c testing & commsisioning suitable for 230volt 50Hz AC supply etc as reqd. |
| 30 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year OriginalEquipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). (Inverter type-Hot and Cold)a) 1.5 TR with 3 Star BEE Rating |
| 31 | Supplying ,installation , testing and commissioning of 4 KVA voltage stablizer wall mounted type for domestic use copper wound complete upto 1.5TR Capacity Air Conditioners unit, , Operating Voltage range (Input): 150-280 volts,Output 230+ 10 Volts, 50Hz AC supply etc. as required. |
| 32 | Supply and fixing of 15/16Amp 3pin top plug including connection complete as reqd. |
| 33 | Supplying & Fixing 25 mm diameter PVC heavy duty pipe for drainage in the existing split type AC unit with supporting clamps etc . complete as reqd. |
| 34 | Supplying and fixing of Extra copper refrigerant piping of 5/8”, 3/8”, 1/4” i/c nitrile rubber insulation wrapping etc. complete as reqd. |
| 35 | Providing and fixing of 3 core 2.5 sqmm PVC insulated and PVC sheathed bright annealed copper conductor cable for communication between indoor unit/outdoor unit/controllers inside building in existing steel/PVC Conduit/ surface/ existing channel, i/c making connection etc as reqd. |
| 36 | Supplying and fixing stand for the outdoor unit of the STAC made of MS duly powder coated complete etc as required. |
| 37 | Credit for dismantle Assorted : Ceiling Fan |
| 38 | Assorted : Stabilizer |
| 39 | Assorted : wall fan |
| 40 | Assorted : SP /DP MCB upto 63 A |
| 41 | Assorted : switch/socket/regulator |
| 42 | Assorted : MCCB |
| 43 | Assorted : LED batten/Downlighter/fl. Fitting |
| 44 | Assorted : 2x2/1x4 fitting Please Enable Macros to View BoQ information |