| 1 | Routine maintenance and attending day to day complaints of electrical installations and compound/security lights alongwith allied fixtures & feeder pillars etc. including repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc and providing assistance to the Engineer-in-charge during breakdown maintenance complete with replacement of worn-out parts issued by the department to the contractor & keeping the entire installation on functional mode including running maintenance & operation and general upkeep of various capacity drinking water supply pump sets in different location along with sluice / gate valves etc. to fill up over head water tank for timely delivery of water supply and carrying out the daily drill comprising of cleaning of pump house and maintaining log book for above installation & keeping the entire installation on functional mode by deploying following staff on all working days of month excluding Sunday & Holidays as per terms & conditions attached and as per direction of Engineer-in-charge etc. as required.(a) Wireman-cum-E&M Operator - 6 Nos. (General Shif)(b) Khallasi - 3 Nos. (General Shif) |
| 2 | Running maintenance & operation and general upkeep & cleaning of various capacity 2 Nos DG Set comprising of AMF Panel & allied accessories for maintaining essential power supply, as and when required, on account of failure of main electrical power supply/load shedding including minor repair works, as and when required and recording reading in log book, keeping the entire installation on functional mode by deploying following staff in on all days of the month excluding Sunday & Holidays as per terms & conditions attached and as per direction of Engineer-in-charge etc. as required.(a) Wireman-cum-E&M Operator - 1 No.(b) Khallasi - 1 No. |
| 3 | Providing services for routine maintenance & operation of 1 No. passengers lift installed for smooth operation and routine checking to ensure proper functioning of passenger lift & providing immediate assistance during emergency situation by deploying adequately trained & experienced following staff on all working days of month excluding Sunday & Holidays for providing above mentioned services as per terms & conditions attached and as per direction of Engineer-in-charge etc. as required.(a) Lift Operator - 1 No. |
| 4 | Payment of overtime to the Wireman-cum-Operator/Lift Operator for operation of passenger lifts beyond duty hours and also on Sunday & holidays as per terms & conditions attached and as per direction of Engineer-in-charge etc. as required. |
| 5 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.5.01) Group C |
| 6 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required6.01) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 7 | 6.02) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 8 | 6.03) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 10 | Supplying and fixing following size/ modules, GI/PVC box along with modular base & cover plate for modular switches in recess etc. as required.8.01) 1 or 2 Module |
| 11 | 8.02) 3 Module |
| 12 | 8.03) 4 Module |
| 13 | 8.04) 6 Module |
| 14 | 8.05) 8 Module |
| 15 | 8.06) 12 Module |
| 16 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.9.01) 5/6 A switch |
| 17 | 9.02) 15/16 A switch |
| 18 | 9.03) 3 pin 5/6 A socket outlet |
| 19 | 9.04) 6 pin 15/16 A socket outlet |
| 20 | 9.05) Telephone socket outlet |
| 21 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).10.01) Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm)36 watt |
| 22 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).11.01) Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm)18-22 watt Please Enable Macros to View BoQ information |