| Sl. No. | Item Description |
| 1 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, round tiles,Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch,Modular plate with grid plate, screws, making connections, testing etc. as required. |
| 2 | Short point (up to 3 mtr.) |
| 3 | Medium point (up to 6 mtr.) |
| 4 | Long point (up to 10 mtr..) |
| 5 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, round tles, Hot Dipped Galvanized M.S Modular box of 20 SWG with earth terminal,6 A two way Modular switch, Modular plate with grid plate, screws, making connections, testing etc. as required. |
| 6 | Medium point (up to 6 mtr.) |
| 7 | Long point (up to 10 mtr..) |
| 8 | Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, Hot Dipped Galvanized M.S Modular box of 20 SWG with earth terminal, 6 A modular switch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required. |
| 9 | On board |
| 10 | Long point (up to 10 mtr..) |
| 11 | S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required. |
| 12 | 20 mm |
| 13 | 25 mm |
| 14 | 32 mm |
| 15 | 50 mm |
| 16 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. |
| 17 | 2 x 1.5 sq.mm |
| 18 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 19 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 20 | 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. |
| 21 | 4 x 10.0 sq.mm |
| 22 | 1 x 4.0 sq.mm |
| 23 | Supplying and drawing PVC jacketed with annealed bare copper inner conductor & tinned copper conductor shielding foam PE dielectric coaxial cable of approved make in existing surface or recessed conduit/casing capping including making connections as required.RG - 6 |
| 24 | Supplying and drawing PVC/ Polythene insulated and PVC sheathed unarmoured/ armoured telephone cable with 0.5 mm dia. Tinned / annealed copper conductor taped &confirming to ITD specification S/WS -113C of approved make in existing surface or recessed conduit/casing capping. Unarmoured Telephone cable in existing surface or recessed conduit/casing capping., 1 pair |
| 25 | Supplying and fixing of power plug point Modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost of modular 16 amp. Switch and socket outlet , making connection , testing , etc. as required. |
| 26 | P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and enamel paint including cutting, welding, holes etc.of following sizes as required. 35mm x 35mm x 5mm |
| 27 | P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. |
| 28 | 3.0 mm thick |
| 29 | 9.0 mm thick |
| 30 | P & F phenolic laminated sheet 2.0 mm thick of size 75 mm dia. Including screws, cup washer as required. |
| 31 | P & F P.V.C. sheet of size 75 mm dia. Including screws, cup washer as required. |
| 32 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. |
| 33 | Single pole MCB6 A to 32 A rating |
| 34 | Triple pole MCB40 A 63 A rating |
| 35 | Four pole MCB40 A 63 A rating |
| 36 | P&F 240/415 V Residual current circuit breaker conforming to IS:12640:1988/ IEC 61008 on existing board/sheet including making connections, testing etc. as requiredTwo pole 30 mA sensitivity, 25 A rating |
| 37 | P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required.Double door (Three phase), 8 Way |
| 38 | P&F recessed/ surface mounting heavy duty Vertical type 16 SWG sheet steel Distribution board with provision of incomer suitable for MCCB and SP / TP MCB as outgoing , phophatised ,powder painted complete with insulated suitable rating copper bus bar , neutral link, earth link and din bar, masking sheet & conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required.Double door with Provision of Incomer MCCB 200/ 250 A Rating, 6 Way |
| 39 | P & F IS:371 marked 6 amp surface type ceiling rose including making connection testing etc. as required. |
| 40 | P & F ISI marked 6 amp bakelite batten/angle holder including making connection testing etc. as required. |
| 41 | P & F ISI marked ding dong/musical chime bell including making connection testing etc. as required. |
| 42 | P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required |
| 43 | 2 pin Telephone socket |
| 44 | T.V. coaxial socket |
| 45 | 5 step fan regulator 2 Module |
| 46 | 25 Amp. 2 Module Motor Starter with on / off Push button |
| 47 | Blanking plate |
| 48 | P & F modular Down light/Foot light with recessed metal box, fitted with lamp holder, covered with polycarbonate louvered four module plate including making connection testing etc. as required. |
| 49 | SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet , required hardware ,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear . Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator) |
| 50 | Supplying and fixing of Aluminium / Copper bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves.Electrolytic grade Aluminium bus bar |
| 51 | SF of (0-500) V range Volt meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type |
| 52 | SF of CT operated direct reading type Ampere meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.Analog type ( 96 mm x 96 mm ) Below 500 A |
| 53 | SF of Current Transformer , with all necessary support in existing panel including connection etc. as required .from 500 / 5 to 1600/5 Ratio , 15 VA , class 1 accuracyfrom 500 / 5 to 1600/5 Ratio , 15 VA , class 1 accuracy |
| 54 | SF of selector switch of 10 A for voltmeter (4 position ) including making connection etc. as required . |
| 55 | SF of CT linked selector switch of 10 A for Ampere meter (4 position ) including making connection etc. as required . |
| 56 | SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required. |
| 57 | Red/yellow/Green colour |
| 58 | Blue colour |
| 59 | S & F of Electrical insulating rubber matts confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required.3.3 KV, 2 mm thick with proof voltage 10 KV / 3 min. and Break Down Voltage 30 KV |
| 60 | SITC of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR . including making connections with suitable capacity conductors/cables testing etc. as required.Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) |
| 61 | SITC of microprocessor based three phase sensing power factor correction relay having following sensing capacity secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, metering facility as required. 12 to 14 stage, sensitivity up to 50 milli Amp |
| 62 | P & F Cam operated rotary switches on existing panel with 2 way and off position one pole 32 A |
| 63 | P & F of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current , conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. |
| 64 | 7 to 10 KVAR |
| 65 | 11 to 20 KVAR |
| 66 | SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs & spreaders, etc. as required. With Thermal Magnetic release 200 Amp , 25/35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu, With Thermal Magnetic release200 Amp , 25/35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu |
| 67 | SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push ( test ) to trip , including making connections with lugs & spreaders, etc. as required.With Thermal Magnetic release |
| 68 | up to 100 Amp , 25 kA, fixed O/L & S/C setting |
| 69 | With Thermal Magnetic release160 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu |
| 70 | With Thermal Magnetic release200 Amp , 25/35kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu |
| 71 | With Thermal Magnetic release250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu |
| 72 | With Thermal Magnetic release400 Amp ,35 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu |
| 73 | With Thermal Magnetic release630 Amp , 35/50 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu |
| 74 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. |
| 75 | 10.0 Sq.mm, 2 core |
| 76 | 10.0 Sq.mm, 4 core |
| 77 | 25.0 Sq.mm, 4 core |
| 78 | 35.0 Sq.mm, 3.5 core |
| 79 | 70.0 Sq,mm, 3.5 core+C77 |
| 80 | 120.0 Sq.mm, 3.5 core |
| 81 | 185.0 Sq.mm, 3.5 core |
| 82 | Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) duly crimped with crimping tool, PVC tape etc of following size. |
| 83 | 10.0 Sq.mm |
| 84 | 25.0 Sq.mm |
| 85 | 35.0 Sq.mm |
| 86 | 50.0 Sq.mm |
| 87 | 70.0 Sq.mm |
| 88 | 95.0 Sq.mm |
| 89 | 120.0 Sq.mm |
| 90 | 150.0 Sq.mm |
| 91 | P / L of Double wall corrugated HDPE pipe confirming to IS : 14930 P - 1 & 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required of Gemini or IS:14930 marked make. Outer Dia. / Inner dia. |
| 92 | 90 / 76 mm |
| 93 | 110 / 95 mm |
| 94 | P & Laying XLPE insulated IS:7098/II/85 of Group1 and approved make H.T.cable for working voltage 11 K.V.Earthed direct in ground including excavation of 30cmx100cm size trench, 25cm layer of river sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size. 3 core 150.0 Sq.mm |
| 95 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/joint kit of Group1 and approved make suitable for XLPE insulated 11 KV / 33 KV cable, with required components, prepration of cable ends,testing etc. as required of following sizes .11 KV End Termination Kit Outdoor type3 core 120/150/185/225 Sq.mm |
| 96 | Maintenance free Gel Earthing with Pipe in pipe / Pipe in strip technology filled with anti corrosive conductive compound ( CPRI Tested ) below the ground in 150 - 200 mm dia. earth pit & surrounding filled with required mineral filling compound ( MFC should have hygroscopic property to retain the moisture for long time to create low resistance zone ) and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete testing of earth resistance as required. of following sizes.With Strip in Pipe Technology with 80 - 100 micron GI CoatingGI pipe 2000 mm long ,63 / 80mm, Inner strip 50 mm x 3 mm copper |
| 97 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
| 98 | 8 SWG copper Wire |
| 99 | 25mm x 3mm copper strip |
| 100 | S & Laying following size' B ' class G.I. Pipe confirming to IS : 1239 P - 1 ( 1990 ) with accessories for laying earth conductor/strip / cable in ground/surface/recess as required |
| 101 | 50 mm dia. |
| 102 | 100 mm dia. |
| 103 | Making of hole in wall of required size for housing exhaust fan and making good the same, with cement plaster as required of following size:Up to 457 mm size |
| 104 | P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . |
| 105 | P&F of Double ball bearing, capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible copper conductor ,making connections, testing etc. as required.300 mm sweep |
| 106 | P&F of Heavy duty capacitor start, Double ball bearing 900/1400 RPM single phase ISI marked Exhaust fan,IS:2312 marked in existing opening including making connections testing etc. as required.300 mm sweep(900/1400 RPM) 300 mm sweep(900/1400 RPM) |
| 107 | P & F of capacitor start, metal body, metal blade three speed wall mounting fan of following sweep with the help of anchor bolts including making connection testing etc. as required.400 mm sweep(Oscillating type) |
| 108 | P & F extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as reqd. |
| 109 | P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as reqd.Up to 380 mm size |
| 110 | Supply & Fixing ISI marked ( IS : 15683 ) Portable Fire Exitnguisher, ABC type,finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of following capacity.4 kg |
| 111 | SITC of self contained drinking water cooler with energy efficient hermetic sealed type compressor, non CFC refrigerant suitable for operation on 230V/1pH/50Hz AC supply, Full stainless steel (S304) body and tank, stainless steel water tray, minimum two nos. faucets and suitable drainage system complete in all respect with 300mm height MS fabricated and painted plate form complete in all respect of the following capacity.Cooling capacity 150 Ltr./Hr. and Storage capacity 150 Ltr. |
| 112 | SITC of RO water system with Filtration stage = Particilate filter- Membrane life enhancer flilter - sediment filter - pre carbon filter - RO Membrane filter - Post carbon filter, Input power Rating - 230 V AC, 50 HZ, Percentage of Rajection TDS - 90% or better having following features (a) Double puriflcation by RO with ESS or latest technology with TDS indicator (b) Spin welded RO Membrane Housing to prevent tempering. (c) Push fit componcnts for leak proof performance (d) Full automatic operation with auto start and auto off (e) SS/ABC construction for corrosion free lifespan. (f) Equally suitable for water from all bore wells overhead storage tanks, water tankers and even municipal taps. (g) RO Membrane Flushing - Auto Flush @ Every Start, Every Stop and every One Hour of working for one minute. complete in all respect with following capacity.Purification capaity -50 LPH, Duty Cycle 270-500 liters/ day. |
| 113 | P & F of 36 Watt IP 20 LED 2' x 2' fixture, Recessed / Surface type, having efficacy of not less than 100 lumen / watt, made out from CRCA housing and with high purity/ transmisvity duffuser for uniform light distribution highefficiency driver electronices and in compliance to IEC standard (intergral with light fixture), Life time of more than 50000 burning hours, CCT 6000K (minimum), CRI>80 driver maintaining PF>0.9 |
| 114 | P & F of 36 Watt IP 20 LED tube light 20 watt with external batten made from CRCA sheet steel suitable to replace T-8/T-12 tube light, intergral driver, 2000 luman + 5% to tolerance system luman efficiacy of 100 Lm// watt minimum expercted life time of 25000 burning hours, CCT 5700K ANSI, CRI>80 driver efficiency > 85%, Life expectancy of driver min 30000 hrs. PD 0.95 at full load/ 230 volt AD. |
| 115 | P & F double ball bearing capacitor start, aluminium body & blade ceiling fan with down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.1200 mm sweep |
| 116 | P&F of IP65 protected LED Street Light Luminaire on existing bracket. Fixture made of powder coated single piece pressure die cast aluminum with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover ( from 45W onwards ) and should be secondary lens on each LED . The System level Luminaire efficacy >=100 with High Power LEDs of CREE/NICHIA/OSRAM/PHILIPS/SEOUL make is to be used .The LED Driver shall be BIS certified and Input Voltage AC 110 to 270 V AC with Input Frequency 50Hz±3% Power Factor>0.95 Driver Efficiency >85% , THD(I) <10% Humidity 10% to 90% RH Working Temp -20C to SOC . Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% initial lumens maintained ,Rendering Index >75% .Surge protection shall be min� 5 KV internal and min 10 KV external. Manufactures Word Mark/Name Engraved/Embossed on die cast housing to allow traceability/authenticity till life offixture. Fixtures shall be CE complianed.LED Street Light fixture 70 Watt |
| 117 | P & F of IP 65 protected high power LED flood light system with Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to acheive various beam angles, 240V, 50Hz - High Power LED fixture suplied with per wired cable of 1 mtr. integrated driver shall be high efficiencey having efficiency more than 85% and in compliance of IEC standards / BIS certified. The system level Luminaire efficacy >=100 with High power LEDs of CREE / NICHIA/ OSRAM/ PHILIPS/ SEOUL make is to be sed LED Driver Input Voltage AC 110 to 270 V AC with Auto resetting Safety Cut-off. Input Frequency 50Hz+3% Power Factor >0.95 Driver Efficiency > 85%, Control Gear Integral Design, THD(1) <10% Electrical Connector Must be provided Surge Protection Min >=5KV internal and 10 KV external in 80 W on wards, Humidity 10% to 90% RH Working Temp -20C to 50C LED Luminaire Specifications Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen mainteance Manufactures Word Mark/ Name Engraved/ Embossed on die cast housing to allow traceability / authenticity till life of fixture Fixtures shall be CE complianed.High Power LED Flood Light 100W |
| 118 | P & F of IP20 LED Recessed / Surface Mounted, Round I Sqaure Non-Dimmable Downlight with die-castaluminum housing & Heat Sink for heat dissipation, high purity reflector with external BIS certified 2.5 KV surge protected driver having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of �100 Im/ watt and life time of minimum 35000 Burning Hours with 70% of intial Lumen maintaned, CCT 3000°K / 4000°K / 6000°K , maximum power consumption should not more than the specified rating and Fixture shall be ofCE complianed. |
| 119 | Recessed Mounting, LED Downlight 18/20w |
| 120 | Recessed Mounting , LED Downlighty 16/20Watt |
| 121 | S I T C of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, as per BEE star level- 2 & BIS approved with losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cableboxes, Off-LTC (+5% to -10%@ 2.5%) winding temperature rise of 50/55 degree C, ISi marked drain valve, Dial type Temperature gauge, first fill of oil, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer. ( TransformerShould be CTL Tested , w/ o any extra cost), 5OO KVA |
| 122 | Supply and erection of P.C.C./R.C.C. pole as per REC manual no 15/1979 conforming to IS: 2905/1966 including excavation of pit and back filling with stone aggregate/boulders and soil in 0.45m consolidating each deposited layer of 0.45m by ramming and watering etc complete in all respect.9.0 Mtr long (200 Kg ) as per Discom specification |
| 123 | Supply and erection of GI stay set as per Discom specification complete with long stay rod with anchor plate including stay clamps turn buckle and G.I stay wire tightened through strain insulator, in cement concrete 1:3:6 including excavation of pit-re-filling etc as reqd.Stay set of dia 20mm,2.4m long stay rod and anchor plate 380x380x6.4mm |
| 124 | Supplying and drawing overhead steel core Aluminium conductor (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required as per Discom specification. 50 Sqmm of (6+1) 3.35 mm (Insulated Rabbit)50 Sqmm of (6+1) 3.35 mm (Insulated Rabbit) |
| 125 | Supply and fixing of 'V' type cross arms made of MS channel on the existing poles complete including all necessary nut and bolt etc with clamps as per Discom specification.11kV cross arms (75 x 40 x 6.8 kg/mtr) |
| 126 | Supply and fixing of top hamper on the existing pole complete including nut bolts etc as required. Vertical type11 kV (.7m long) (65 x 65 x6mm angle) |
| 127 | Supply and fixing 11kV pin insulator( IS 731/ 1971) with minimum creepage distance of 300mm on existing bracket including all accessories like hot dipped GI spindle and nuts etc (as per specificationof Discom). |
| 128 | P & F PVC Storage Tank ISI Marked (IS: 12701) indicating the BIS license No., of approved make with cover, 25mm dia 1 M long G.I. overflow pipe & 25 Cm. long wash out pipe with plug & socket, including Making connection etc., complete of approved design:500 Litres Capacity. |
| 129 | Providing and Fixing Chlonnated Polyviny Chioride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plan & brass threaded fitting i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.) |
| 130 | 20mm nominal outer dia pipes: |
| 131 | 25mm nominal outer dia pipes: |
| 132 | SITC of MNRE approved & confirming to IS:12933 P-1,2,3&5 Evacuated tube Collector type solar hot water system with collector, insulated stainless steel storage tank with electrical back up , MS stand for Collector & Tank etc. as required. of following capacity.500 litre/ day |
| 133 | Supply and erection of M S swaged tubular pole conforming to IS: 2713-1980 (part I to II) with galvanised base plate in position including excavation of the pit and filling the same with C.C. of M-20 grade (1:1.5:3) from base plate to 50 cm above ground level, with the help of steel frame not less than 40 cm dia up to 114.3mm outer dia and 50 cm beyond 114.3mm outer dia around the pole. Duly finished with cement plaster, earthing terminals , cable entry, GI cable sleeve complete as required. The pole shall be fabricated by using ISI mark tube for structural purpose of following height & designation. ( See Table E - 09 for specs.), 8.5 Mtr. ( 410 SP - 17 ) |
| 134 | Add for supply and fixing of M S Overhang of following size over the existing poles76.1 mm OD x 3.25 mm thickness |
| 135 | P&F of thermoplastic/ PVC cable junction boxes of following sizes including clamps for holding the box, cost of DIN rail for MCB mounting, connectors for cables terminals, threaded cable glands made of polyamide material etc. complete in all respect. 175mm X 150mm X100mm |
| 136 | S & F of Street light bracket made out from following size of ' B ' class GI pipe with heavy duty pole clamp, Saddles suitable fastners etc. as required. |
| 137 | 25 mm Dia. |
| 138 | 32 mm Dia. |
| 139 | Supply , Drawing and Testing of 4 pair, 24 AWG UTP Cat 6 Cable as per latest ammendments of TIA /EIA 568 B.2-1 Specifications in existing MS/PVC Conduits including making connections to Information outlets and Patch Panels with ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing required |
| 140 | Supply and Installation of Information outlets made of high impact plastic body ABS FR Grade with spring loaded collapsible shutters in jack Recess, suitable for Cat 6 application complying to latest ammendments EIA/ TIA 568 B.2-1 Specifications in existing modular /MS Boxes along with necessory connections as required |
| 141 | Supply & fixing of Faceplate for Flush / Surface Mount Information Outlets Single Aperture with screw hole covers & Icon Tree Size 86mmX86mm Single Aperture |
| 142 | Supply , Installation, Testing and Comissioning of Rack mounted 19\\", Cat 6 UTP,1.5-1.6 MM CRS chasis , powder coated Modular Patch Panels with collapsible shutters on jacks to support latest ammendments of TIA / EIA Cat 6 Specifications in Existing Communication Rack along with necessary connections of Cat 6 UTP Cables, With Rear Cable management trays and clamps. 24 Ports |
| 143 | Supply , Installation, Testing and Comissioning of Wall mounted Communication rack with glass doors, handles ,lock , Top and Bottom Cable entries, Supports for mounting rack on wall , Cable managers, one Fan, Equipment mounting hardware, power supply box for supplying power to switches, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable9 U(44 mm ) wall mounted |
| 144 | SITC of Managed Layer-2 Intelligent Ethernet Switch providing 24 x 10/100 Fast Ethernet ports and with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software |
| 145 | SITC of radial / mixed flow submersible motor pump sets ISI marked (IS:8034-1989) of approved make with required accessories including making connection suitable for T.W./ D.C.B./ Open well. The job includes lowering of riser pipe, G.I./ H.D.P.E. pipe with rope, cables, installation of complete fitting and accessories, jointing of electrical cables up to switch board. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect.100 mm diameter Submersible pump shall have following HP Rating, phase, Head, minimum Discharge respectively.5.0 HP, 1-Ø, (120-220)Mtr, (100-38)LPM |
| 146 | SITC of ISI mark( IS:8472) self priming monoblock pump set of approved make, TEFC, permanent split capacitor type (PSC), fitted with thermal overload protection, mechanical seal, 1440/1500 RPM, single phase(180 to 240 V). Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively. Self priming pumps1.0/ 1.1 HP, 1-Ø, (10-50)Mtr, (53-6.5)LPM |
| 147 | Supply and fixing of oil / Air break DOL / Star Delta Starter made out of sheet steel powder coated enclosure with single phasing protection, ON / OFF push buttons, etc. complete in all respect suitable for following rating motors.DOL Starter 7.5 HP |
| 148 | Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sum on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed: |
| 149 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand).Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 150 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 151 | Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish 25 mm thick |
| 152 | P & F Gun-metal Non-return Valve or Check Valve(IS: Make) of apprved make, superior quality: 25 mm nominal bore: Horizontal |
| 153 | P & F Full-way Valve (IS:778 Nark) or wheel valve of approved make: Gun-metal 25mm nominal bore. |
| 154 | P & F Stop Cock (IS: 8931 Mark), superior quality & approved make: Brass 400gm. 15mm nominal bore. |
| 155 | Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications:DP :double pole structure on 2 no ISMB 125 x 70 mm, 10 mtr high using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required.GO:Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,GI pipe of suitable length for operation.DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulatorsLA: 3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv Overhead line with rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required.JUMPERS: 3 no 11kv acsr conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’ |
| 156 | SITC of high mast lighting system (as per CP3-TR7/1996 of ILE, UK) consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm, mast head frame assembly with full cover, aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, suitable ropes (AISI 316, 7 / 19 costruction ), EPR insulated PCP sheathed trailing cable, outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning of high mast. ( See table E - 13 for specs.) 16.0 Mtr HM (in 2 section) |
| 157 | P & F of aviation obstruction light luminaire comprising of yellow painted die cast aluminium alloy housing, built in 75 VA step up transformer, heat resistant clear glass cover, neon spiral lamp / 2x100W GLS Lamp / LED Lamps complete in all respectaviation obstruction neon light luminaire |
| 158 | P & F of IP 65 protected high power LED flood light system with Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to acheive various beam angles, 240V, 50Hz - High Power LED fixture suplied with per wired cable of 1 mtr. integrated driver shall be high efficiencey having efficiency more than 85% and in compliance of IEC standards / BIS certified. The system level Luminaire efficacy >=100 with High power LEDs of CREE / NICHIA/ OSRAM/ PHILIPS/ SEOUL make is to be sed LED Driver Input Voltage AC 110 to 270 V AC with Auto resetting Safety Cut-off. Input Frequency 50Hz+3% Power Factor >0.95 Driver Efficiency > 85%, Control Gear Integral Design, THD(1) <10% Electrical Connector Must be provided Surge Protection Min >=5KV internal and 10 KV external in 80 W on wards, Humidity 10% to 90% RH Working Temp -20C to 50C LED Luminaire Specifications Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen mainteance Manufactures Word Mark/ Name Engraved/ Embossed on die cast housing to allow traceability / authenticity till life of fixture Fixtures shall be CE complianed. High Power LED Flood Light 180W Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail