| 1 | CIVIL WORKS |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.All kinds of soil |
| 3 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 4 | Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete |
| 5 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 6 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 8 | Supply and installation of Name Board of suitable size near the High Mast made ofGranite comprising of all required details like Total Cost, Commencement,Completion and Inauguration Dates with all necessary civil works etc. complete asrequired |
| 9 | Supply and installation of Name Board of suitable size made of Acrylic/ACP Sheeton all 4 sides of the Mini Mast using already fabricated and duly painted existing MSStructural supports with Stainless Steel anchor fasteners, bolts, nuts, round and springwashers or screws etc. complete as required |
| 10 | ELECTRICAL WORKS |
| 11 | Supply, installation, testing and commissioning of Outdoor Floor / Wall Mounting Cubical Type KSEBL Metering Panel with Double Door and Canopy suitable for 240 V, Single Phase, 2 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame works and covers, 2 mm thick for gland plates, cleaning and finishing complete with 7 tank process for Powder Coating in approved shade and then provided with Clear Coating, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 12 mm x 3 mm at the rear with 2 Nos. earth stud and control wiring with 2.5 / 1.5 Sq.mm FRLS (Flame Retardant Low Smoke) or HRFR (Heat Resistant Flame Retardant) PVC insulated single core copper conductor cables, cable alleys etc. complete as required. The panel shall conform to the Electrical Inspectorate and KSEBL standards and it shall only be manufactured after getting approval from the Engineer-in-charge and the Consultant.INCOMER1 Nos - Provision for Fixing Single Phase Energy Meter1 Nos - 32A Bakelite Fuse Units with HRC Fuse of Suitable Rating1 Nos - 32A Neutral Link1 Nos - 16A/25A 10kA DP C Curve MCBThere shall be Separate Compartment for Energy Meter and Fuse Units/Neutral Linkwith KSEBL Sealing ProvisionSURGE PROTECTION DEVICE1 Nos - 2 Module DIN Rail Mounting Type 1 + Type 2 / Class 1 + Class II 50kA SPD on the Incoming / Outgoing Side of Incomer MCB along with Green and Red Indication Lamps with Control MCBs [The connections to Phase, Neutral and Earth shall be done using 16 Sq.mm FRLS (Flame Retardant Low Smoke) or HRFR (Heat Resistant Flame Retardant) PVC insulated single core copper conductor cables with less than 0.45m in length]OUTGOING1 Nos - Outdoor / Street Light Compartment with 6A/10A 10kA DP C Curve MCB,25A 30mA DP RCCB, 25A TP AC3 Duty Contactor with Auxiliary Contacts,24Hour Digital Timer Switch, Auto - Manual Selector Switch (2 Pole 2 Way), ON(Red), OFF (Green) Push Buttons and ON (Red), OFF (Red) Indication lamps withControl MCBs |
| 12 | Supply, installation testing and commissioning of Octagonal Pole made of hot dipgalvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mmbase plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 PartIII fixed head frame including round arm luminary carriage suitable to install 4/6 Nosluminaries in symmetrical arrangement including connector and foundation bolt 4Nos on existing RCC foundation using junction box etc. complete as required8 Meters |
| 13 | Installation, testing and commissioning of 200W LED Flood Light with 3Years Onsite Warranty having output greater than 105lumen/W 4000-6000 K with IP66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than0.95 at full load, internal surge protection up to 8 kV and Aluminium pressure diecastPowder coated housing, acrylic cover complete with THD less than 10%, powerfactor greater than 0.98, RoHS compliant, duly wired up for use on 240V AC supply.Driver compartment shall be separately accessible for maintenance (LM 79 and 80certificates from NABL accredited Third party lab to be produced mentioning chipmanufacturer) |
| 14 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 15 | Supply and laying of XLPE insulated and PVC sheathed armoured Aluminium powercable of 1.1 kV grade of the following sizes in the existing excavated trenches, builtup trenches and pulling through existing pipes including all minor civil works etc.complete as required2 Core 10 Sq.mm |
| 16 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.2 core 10 sq mm with factory made clamp |
| 17 | Supply and laying of 2.5 Sq.mm 1.1kV Grade Three Core Round Insulated CopperConductor and Sheathed Flexible cable with compact construction and high insulationresistance. The cable shall have the specifications of Standard FRLS PVC Insulation,FRLS Sheathing in accordance with IS 694, BS 6500, IEC 60227, DIN VDE-0281,IEC 60754-I IEC, 60332-I, BS 4066-I, ASTMD 2843, ASTMD 2863, ConductorClass 5, Number of Conductor Strands 50, Nominal Diameter of Conductor Strands0.25mm, Nominal Thickness of Insulation 0.7mm, Nominal Thickness of Sheath1.0mm, Approximate Overall Diameter 9.6mm, AC Current Rating of 24A, VoltageDrop/Amp/Metre for Single Phase AC 18mV, Maximum Conductor Resistance at 20Deg.C 7.98 Ohms/Km etc. complete as required |
| 18 | Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) |
| 19 | Supply and providing gland earthing using Gland Earthing Clips / Clamps forfollowing size of PVC insulated and PVC sheathed / XLPE Aluminium conductorcable of 1.1 kV grade etc. complete as required2 X 10 Sq.mm |
| 20 | Excavation of all types of soils for the laying of PVC insulated and PVC sheathed /XLPE Aluminium or Copper conductor cable, GI / DWC HDPE / RCC / PVC /Conduit Pipes, Earthing conductors to the required width and depth up to andincluding 1.2m and back filling etc. complete as required. (The trench dimensions andspecifications shall conform to CPWD / PWD, Electrical Inspectorate and KSEBLStandards) |
| 21 | Earthing with ISI Marked Nickel Sealed Copper Bonded 20mm dia, 3.0m long Rodwith T clamp having 250 microns coating thickness tested as per IEC 62561-2 andproviding Masonry Enclosure with Concreate Slab Cover or Heavy Duty FRPEnclosure with Cover Plate having 5000kg load bearing capacity including sufficientearthing compound etc. complete as required |
| 22 | Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG) |
| 23 | Supply and installation of 10 kg/cm2 PVC Pipes of the following sizes with all necessary accessories and laying in existing excavated trenches, built up trenches,clamping in built up trenches / walls / MS supports using Stainless Steel saddles andscrews of which spacing between 30cm to 60cm including all minor civil works etc.complete as requiredUp to and including 40mm |
| 24 | Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanicalprotection to underground power cables with all required accessories in ground in theexisting trench50/38 mm or nearest size |
| 25 | Supply, fabrication and installation of Outdoor Floor / Wall Mounting Cubical TypeKSEBL Metering Panel / PVC Pipe / Cable supports / Name Board supports etc.using MS Angles, Flats, C Channels and Square Tubes of adequate size painted withtwo coats of epoxy primer and two coats of black / grey / other approved shade epoxypaint. The scope also the includes the supply and installation of necessary rectangular/ square plates, anchor fasteners, bolts, nuts, round and spring washers or screws etc.complete as required |
| 26 | Preparation and submission of application for Single Phase Connection along withdrawings, detailed load schedule etc. and co-ordination with KSEBL for energizationetc. complete as required. (*All Statutory fees for getting connection shall also comewithin the scope of the Contractor) |
| 27 | EXCLUSIVE OF GST Please Enable Macros to View BoQ information |