Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Please Enable Macros to View BoQ information |
| 2 | Construction of Intakewell at bank of SONE RIVERInvestigation, Planning, engineering ,Drawing /Design,Vetting of drawing from IIT, soil investigation (up to boring 30m depth) and CONSTRUCTION OF INTAKE WELL CUM PUMP HOUSE as per design for 12 MLD WITH RCC FOOTBRIDGE with pillar up to 150 m length and 3.60m width(with 0.5m width both side foothpath colour zigzag M30 concreting paver blocks ) with rcc pier with both side handrail 1.8m height all necessary equipment & Appurtenant Works, including desilting arrangment, Electrical works, including supply of all materials, labour, tools and plants etc. Provision for piping work for flushing choking material from the inlet pipe complete as per instruction of engineer in charge. Provision for inlet pipe of 400 mm dia (3x20m). Supply and fixing of Kirloskar Sluice valves 3 nos of Pn 20 of dia 400 mm with spindle/wheel with all mountings and accessories complete. Supply and fixing of M.S. Ladder for Intake Well inside the reservoir of dam or river, with minimum required depth and diameter as mentioned below with pump house in RCC framed Structure, of minimum height of 6.0 m with required length of RCC footbridge with railing, of minimum 3.6 m clear width or more as required to transport the pumping plant machinery by vehicle excluding curb, piping & cable, pump floor level minimum 1.5 m above HFL, water inlet openings with sluice gates, having different intake capacity of water at different inlet points, construction of spiral RCC staircase upto bottom, grit chamber with mechanical scraping belt or bucket for de-gritting the well, Pump house operating Slab, a separate electrical gantry of suitable capacity, cement concrete floor with hardener, rolling shutter fabricated from steel, Circular Balcony minimum 1.5 m width, staircase post-column beams, Railings, Dg set yard, transformer yard,meter room,guard room, landescoping,orboriculture, greeneries,plantation, lighting arrengments development of land,20 cm th.CC approach road (3.6Mtr wide) , required length 1.8 M heigth RCC BOUNDARY WALL WITH 3.6m wide MS GATE with 1.2 M wide wicate gate etc. arrangement should be made inside pump house such that to fix required nos. of VT Pumps HT/LT panels and starters, including all earthing as requried, instrumentation & SCADA & wireless telemetry (voice & Data), internal and external electrifications and adequate LED lighting including excavation of soil i.e. Kankar mixed morrom/soft/hard rock and concrete of minimum grade of M-15 and all R.C.C. work in grade M-30 or above in raft/pile foundation, Intake, RCC, wall with supply of all type steel bars of approved quality and cement as approved by the Employer, cofferdam construction with bailing out water as per site construction requirement diversion arrangement of flow of river during construction by making bundh across the river supply with gunny bags, sand, fixing suitable size of steel girder, dismantling and refixing etc. and also supply and fixing of collapsible gate, Aluminium door, Aluminium window as per relevant specifications, fresh air circulation arrangement, including of one-coat Primer, two coat Distamper in inner side & external painting with apex ultima/equivalent paint, all steel work must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification of intake well, supply and fixing of three-row railing of 20 mm dia GI Pipe with M.S. Angle posts supply and fixing of inlet openings of required capacity, including supply of all materials, all labor T&P etc. required for proper completion of works as per direction of the Engineer and Consultant, Anything not mentioned will be as provision laid down in CPHEEO GOI Manuals. Cost of VT Pumps, Motors. Panels, SCADA, Panel Board, Pipes etc. are not covered in this item incluidng construciton of electric power sub-station room size (8.0mx5.0mx4.0m) &CONST. of 80 MTR RIVER PROTECTION WORKS. |
| 3 | Construction of Water Treatment Plant Survey, Planning ,Engineering ,Investigation, Planning,Drawing/ Design, vetting of design/drwaing from IIT, soil investigation ( up to depth 30 M), Construction and Commissioning of WTP capacity 7 MLD with CWR as per required capacity. For construction of WTP, Admin Building with Command Control Room, Sub station room and fire fighting arrangements, first aid arrangements Circular Cascading Aerator, Inlet chamber, alum dosing, pre-sedimentation Tank, Rapid Mix, Vertical Flow Clarifloculator, Rapid Gravity Filter with Back Wash Arrangement, reuse arrengments, Proper Sludge Disposal and Backwash water disposal arrangements to nearest drain/low laying area & Appurtenant Works. Automated through PLC with outputs to SCADA, walkway in between WTP components with railing, 10 sqm area Guard Room, 2 storey 2 ROOM SET -2 NOS staff quater ( 4 NOS), 150sq.m plinth area admin building with required furnitures (Godrej make), &1.5 ton capacity 5 star AC-2 nos, 40 sq.m lab with isi mark appreatus,60 days storage capacity Chemical Store House, Gaseous Chlorination Plant,4m width CC approach road Landesceping,Development of WTP area with adequate greeneeries, orboricutures, plantation, Rainwater & ground harvesting unit. 1.8 m heigth required boundary wall with 4.5 mtr wide 1.2 m tr wide wicket gate, Raw water to be treated and filtered. Lean concrete to be used of grade not less than M-15 and other structures in minimum M-30 grade of concrete. Cement and steel should be as per approved by the Employer/IS code. Collapsible MS steel doors and aluminium windows to be provided including of One-coat Priming, internal two coat Distamper painting, external painting with apex ultima/equivalent paint/Weither Paint, all steel work must be painted with red oxide paint and two coat of anticorrosive paint , 3 coat foodgrade epoxy of inner parts of concrete etc. and internal and external electrification with adequate 20 nos DUAL SOLAR with battery LED lights (4.5M heigth)& 2 N0S HIGH MAST LIGHT ( 16 m heigth) for the compound, including automation, instrumentation & SCADA, wireless telemetry (voice & data) Including water testing kits, 40 SQ.M AREA lab building and essential isi mark lab equipments AS PER CPHEEO Manuals Including supply of all materials, labour T&P etc. required for proper completion of works as per direction of the Engineer and Repudiated make 03 Nos. Computer( i7 processor) sets with CPU] Monitor, Printer and Photo copy machine for Mirzapur office for (Monitoring of WTP and Zonal pumping station from Scada) (Civil Work). |
| 4 | Rising Main :- Supply of following sizes (DI K-9) pipes for rising main system conforming to latest/relevant I.S. 8329/2000 Specifications with all jointing materials such as MJ joints, tee ,bends, all required mild steel fabrication works (if MS fabrication used, its proper protection treatment against corossion must be done) and all DI specials conforming to latest /relevant I.S. specifications, suitable for D.I pipes, as per IS‐1239 /2000 and IS 8329/2000 or their latest amendment & CPHEEO latest amendments including F.O.R. destinations rate per metre in Rs., anywhere in U.P. including cost of one Rubber Gasket per pipe length & iniclusive of all Taxes & Duties, Third Party Inspection Charges, Packing & Forwarding Charges, Transit Insurance Charges, Road Transportation Charges etc. with loading, unloading and Carting up to store to site, jointing, laying, HYDRAULIC TESTING AS PER CPHEEO MANUALS latest amendments also including specials for these pipes all complete as per instructions of Engineer ‐in ‐ charge.Note- Only SBR Rubber Gaskets to be used as per IS- 5382 and IS- 12820. |
| 5 | 350 mm DI Pipe Class K-9 |
| 6 | 300 mm DI Pipe Class K-9 |
| 7 | 200 mm DI Pipe Class K-9 |
| 8 | 150 mm DI Pipe Class K-9 |
| 9 | Supply , carting, laying, jointing & fixing in pipe of following size of CI D/F SLUICE VALVES IS-780-1960 tested to 16Kg / Cm2f trenches, jointing and testing etc. complete. |
| 10 | 350 mm |
| 11 | 300 mm |
| 12 | 200 mm |
| 13 | 150 mm |
| 14 | Earth work in ordinary soil, In Moorum /Kankar / Shingle, In Soft/Medium rock. Etc. loam, clay or sand with lift upto 1.50M and lead upto 200m, barricading, Refilling the soil as required, incluidng depositing in layers not exceeding 150 mm, watering and compaction to 95% of the Standard proctor density, level dressing, including supply of all lebour, T&P etc. required for completion of the work. Ramming of excavated earth into the trenches and disposal of surplus earth upto 8KM. and restoration of damaged overhead & underground utility.The trenches shall be properly barricaded and fenced off wherever necessary. RED FLAGS AND CAUTION BOARDS during day and red lights during night shall be displayed so as to avoid any accidents.. its includes provision of making of alignment on city roads, making trial pits to investigated location of various under ground services like telephone cables, electric cable, existing pipe lines and sewer line etc. arrangemnts for diversion of traffic and associated marks etc. with supply of all necessary equipments, materials, labour and T&P etc. complete required for completion of work. |
| 15 | In Ordinary soil |
| 16 | In Moorum /Kankar / Shingle etc. (with replace loose soil) |
| 17 | In Soft/Medium rock. (with replace loose soil) |
| 18 | Supply of all materials, labours T&P etc. and construction of masonary type sluice valve chamber. With extra heavy duty MS cover. |
| 19 | Thrust Block |
| 20 | Supply of all materials,labour, and T & P etc. and construct R.C.C.(M-25 grade) thrust blocks. Including mild steel (1%)works all complete as per design for following size and instructions of Engineer ‐in ‐ charge. |
| 21 | 350 mm (size 1.25m x 1.25m x 1.25m) |
| 22 | 300 mm (size 1.15m x 1.15m x 1.15m) |
| 23 | 200 mm (size 0.85m x 0.85m x 0.85m) |
| 24 | 150 mm (size 0.70m x 0.70m x 0.70m) |
| 25 | Dismantling of following type of road surface including stacking of serviciable material and disposal of unservicable material within the limit of npp upto 8km distance including supply of all labour T&P etc. required for proper completion of the work as per instructions of Engineer ‐in ‐charge. |
| 26 | Bituminous Road |
| 27 | C.C. Road |
| 28 | Interlocking Road |
| 29 | Re-instatement of following type of road surface of PWD/ UPJN specifications including supply of all materials, labour, T&P etc. required for proper completion of the work as per instructions of Engineer ‐in ‐charge. |
| 30 | Bituminous surface (20cm sand, 20cm GSB, 20cm WMM, 5 cm to 8 cm DBM, 3cm to 4 cm B.C.) payment made upto WMM- 50%, DBM- 30% and BC with testing in NABL aprooved lab/PWD- 20% |
| 31 | C.C. Road in M25 grade, minimum thickness 15cm on 15cm sand & 20cm GSB filling base. |
| 32 | Interlocking Road (50% new Interlocking bricks M-30 grade, 80 mm thick on 10cm sand & 10cm GSB filling base) |
| 33 | Providing and laying of GSB for reinstatement of earthen road (Shoulder) including dressing, watering, ramming etc. complete. |
| 34 | Provision for NALLA/CULVERT CROSSING UP TO 200MM DIA PIPE CROSSING including all material, for casing etc. all complete work. With concreting thrust block M20 grade using inlcuding supply of DI K-9 Pipe and laying with MS Fabrication and DI Specals. |
| 35 | Provision for NALLA/CULVERT CROSSING UP TO 200MM DIA PIPE CROSSING including all material, for casing etc. all complete work. With concreting thrust block M20 grade using inlcuding supply of DI K-9 Pipe and laying with MS Fabrication and DI Specals. |
| 36 | Provision for Crossing and laying of RISING MAINS pipe line of both side at State/National Highway and payment to UPSHA/PWD for permission of National/State Highway crossing:- Survey site Investigation Planning , design Drawings, excavation, dismentaling, road restoration & other all utility restoration( as per required) as per NATIONAL HIGHWAY standard as per MORTH Road manual and vetting / checked from State Road/ NH DIV. PWD/NHAI/UPSHA/ PWD/ Divisional Office and taking NOC CHARGES.(incl. noc fees, licence fees, security amount) for trenchless crossing of National highway road , Road for required dia Rising main pipe with casing pipe as required for proper completion of work also including security money deposited to State Road department and Execution of all work in the present of State Road staff / Engineers including of supply of required dia MS carrier pipe and required size of MS casing pipe as per drawing and as per (IS:3589 & made from confining to IS:2062) with 750 Micron th. food grade coating internally and 750 TH. MICRONE anti corrosive bituminous paint externally by trenchless technology method at an average depth 3.60 mtr from normal ground level up to top of casing pipe including dismentalling , restoration ,excavation & sand filling of Pit, Dewatering arrangement, Supporting system for soil, also including supply and fixing of 2 no Sluice valve ISI Mark, construction of sluice valve chamber with heavy duty MS cover etc. all complete work including supply & fixing specials in carrier pipe over main pipe, as per specification given in the bid documents including supply of all materials, labour T&P etc. for proper completion of work as per instruction of Engineer. and concerned department. (CASING- 600MM (id) MS PIPE 12 MM THICK & CARRIER PIPE (8mm th.)- AS PER REQUIRED DESIGN) INCL.3M C/C SPACER |
| 37 | Supply of all materials labour T&P etc. for complete construction of R.C.C. (M30 Grade) Over Head Tank of following capatity and staging min 1m above ground level with main components, soil testing and assuming bearing capacity of soil as 8MT including cost of supply of design and drawings. all the water retaining components of OHT shall be casted in M-30 grade cement concrete and minimum grade of concrete of foundation and staging should be M-25 with approved cement, coarse sand and stone grit as per I.S. 11682 and I.S. 456 seismic effects and wind load should be taken into consideration as per I.S. 1893 for earthquake resistance and I.S. 875 Part-III for wind load on structure and including 1M wide RCC doglegged staircase with separate columns, 1m wide R.C.C. M30 balcony, M.S. ladder made of 50x50x6mm angle section and 20mm plain M.S. bars with hand rails of 20mm medium class G.I. pipes, one aluminum ladder inside the tank from top dome to bottom dome, R.C.C. railling with 20mm dia medium class G.I.pipe (in 3 rows) on both sides of stair case, supported on 50x50x6mm M.S. angle section, spaced at intervals not more than 1.5m, proper ventilator at top dome in circular shape of 1.5m dia, Ultra Sonic Water Level Indicator fabricated with sensor connecting to automation, lightening conductor as per I.S.S. 2309 or its latest amendments of latest electricity rules, consisting of proper elecation rod with 5 or more fork points as prescribed in ISS 2309-1969 and ISS 3013-1966 C.I. manhole of min 60x60cm size with locking arrangement, supply, fixing, jointing of D.I.D/F Pipes of appropriate size with D.I.D/F specials conforming to IS 8329/2000 as vertical pipes for all required no of inlet (200mm OR as designed), all required no of outlet (250mm or as designed for each DMA), overflow and washout as per latest/relevant I.S. specification with all jointing materials for proper completion of work along with NRV Sluice valves with actuators construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit, construction of inlet, outlet, washout, overflow chamber with extra heavy duty MS cover and chambers for sluice / butter fly valves as per departmental type design and drawings, supply of 300mm dia DI K-7 pipe as per I.S.-4985/2000 for disposal of water from overflow and washout chamber to suitable point outside the water works compound, painting of all concrete surface and steel pipe works with three coats. For bidding purpose, bearing capacity of soil shall be considered as 8 t/sqm. working design shall be based on the SBC determind after soil investigation /8 tonne/sqm including requird earthfilling for maintaining FGL as per level of nearest road cost of earth required for filling not to be paid extra.Note :- The bid price of over head tanks is to be submitted considering net safe allowable bearing capacity as 8 t/m2, keeping the minimum foundation depth to be 2.5 m below existing ground level at the site of work, layout as ground level of over head tank consider from 100 cm above than near of road surface to be finalized by the engineer in charge including, campus cleaning, removal of debries, bush cutting and disposal with in municipal limt and filling ogf earth if required as per direction of Engineer in charge. The successful bidder will be required to investigate the soil bearing capacity. If not safe allowable bearing capacity is found to be equivalent or more than 8 t/m2, the design of OHT will be based on 8 t/m2 capacity. However in case the net safe allowable bearing capacity is found to be below 8 t/m2, then the design of OHT will be based on the actual bearing capacity. |
| 38 | For Zone-1 (1350 KL/22 m stagging) |
| 39 | For Zone-4 (450 KL/22 m stagging) |
| 40 | Repair of RCC Over Head Tank 350 KL/16 m Staging and allied works in water campus including Providing and fixing double scaffolding system (cup lock type) on the exterior side of OHT, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @ 0.05kg/running metre and while the suface is tacky filled the groove up to surface with crystalline mortar @1.50kg/running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @1.50kg/running metre. 18 mm cement plaster in two coats under layer 12 mm thickcement plaster 1:5 finished with a top layer 6mm thick cementplaster 1:6. Providing and injecting approved grout (OHT tank body) in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-inCharge. Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/RCC work. Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/RCC work. Epoxy injection grout in concrete/RCC work of approved make. Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures. For vertical surface one coat @1.40 kg per sqm., Cone wall, wall inner, column inner, For horizontal surface one coat @1.10 kg per sqm for Bottom Dom including repairing of MS ladder, 1 m vide RCC balcony, railing, ventilater of top Dome, Water Lever Indicator, CI Mainhole., Sluice valve and Construction of S.V. Chamber, Cleaning of OHT and Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete., Finishing of all Wall/concrete surface in two coat premium acrylic smooth exterior paint with silicon addive, with one coat of exterior primer over smooth base of white cement. cement based wall putty and steel pipe works with three coats of approved cement paint and anticorrosive paints.,foodgrade epoxy painting internal part of water containe with 3 coat, Painting of all m.s./ steel pipe works with three coats of approved cement paint and anticorrosive paints and disposal of water from overflow and washout chamber to suitable point outside the water works compound, painting of all concrete surface and steel pipe works with three coats. |
| 41 | Construction of RCC Common CWR 925 KL under Zone-1 for Water Demand of Zone-1/2/3 & 4 - Survey, Investigation, Soil Testing, Planning, Designing, Construction, Commissioning of CWR of 925 KL. The Concrete in a minimum grade of M-30 and steel to be used as per IS code and approved by Employer. Seismic effects and wind load with earthquake resistance should be taken into account in the design. CWR should be provided with a ventilator, manhole of adequate size. An aluminium ladder minimum of 0.45 m wide in manhole should be provided. Ultrasonic water level indicator should be provided along with lighting conductor as per IS 2309. PCC of M-10 grade to be used in bed blocks. Inlet, Outlet, washout, desilting and Overflow arrangement with the supply & installation of pressure pipe of the suitable dia, for taking overflow water to a suitable low lying area. Painting of all steel and concrete pipes with 3 coats of approved cement plaster and 3 coat food grade epoxy & anticorrosive paint including all labour, material, T & P etc., all required for proper completion of works as per the direction of the Engineer. |
| 42 | PUMP HOUSE - Survey, Investigation, Planning, Designing, Construction, Commissioning of Pump houes of required size to accommodate required nos of pumps. For the construction of Pump House above CWR, minimum 6 m height is to be kept with suitable arrangements to install and dismantle VT/HSC pumps and installation of Fire Extinguishers, Power wiring & earthling system, rubber resistance sheets, spares for motors & switchgear, internal & external electrifications and adequate LED lighting, 23 cm. thick brickwork 1:4 (one cement and four sand), plasterwork 1:4 (one cement and coarse sand). Steel and cement to be used as per approved by Engineer-in charge / IS code. Reinforced Cement Concrete minimum M-25 to be used including fixing of doors, windows, shutters, glass panels with gantry girder arrangement with supply and fixing of suitable sizes of steel girder including snowcem painting two coat over one priming coat using approved Colour and shade and whitewashing three coat of ceiling of pump house and painting over new ironwork with one coat of primer and two coat of approved paint including cost of all arrangement of staircase, balcony with medium G.I pipe 20 mm size three row railing, shuttering, scaffolding and water with supply of all materials, labours T&P etc. required for proper completion of works as per direction of the Engineer. FFL above 60 cm nearest road level. |
| 43 | Construction of electric power sub-station room- Survey, Planning,engineering,Drawing/ Design, vetting of drawing/ design from IIT ,Investigation, Soil Testing, Planning, Designing, Construction of electric power sub-station room (8.00m X 5.00m X 4.00m) of required size. Construction of RCC frame structure room including excavation of soil i.e. Kankar mixed morrom/soft/hard rock, PCC for bedding in lean concrete of minimum grade of M-15, R.C.C. in grade M-25 or above in footing, foundation, plinth beam, column, lintel beam, chajja, roof slab, brick work in CM 1:4 (1 cement & 4 sand) in walling, Internal plaster 12 mm thick for walls & celling in CM 1:4 (1 cement & 4 Sand), External plaster 20 mm thick in CM 1:4 (1 cement & 4 sand), providing laying hand cut polished kota stone flooring 25 mm to 30 mm thick on bed of CM 1:4 (1 cement & 4 sand) including cement float, filling jointing with neat cement slurry, curing polishing and cleaning, providing cable duct of required size, including fixing of rolling shutter, aluminium windows & ventilator with glass panels as per specifications, providing and applying white washing in two coat to new plaster surface, internal two coat snowcem painting including priming coat, external painting with apex ultima/equivalent paint including priming, painting over new iron work with one coat of primer and two coat oil paint of approved make including cost of all arrangement of shuttering, scaffolding including all materials, labours T&P etc. for proper completion of works as per direction of the Engineer. At Zone 1. FFL above 60 cm nearest road level. |
| 44 | Construction of LCS Room size of 6m x 4m x 4m including Supply all materials, labours T&P etc. all complete work including Excavation, PCC(M-15), RCC(M-25), Brick work(1:4), plaster(1:3), painting, door window, collapsible steel shutters, electric wayring etc. all complete work. Cement and steel should be as per approved by the Employer/IS code. Collapsible MS steel doors and aluminium windows to be provided including of three-coat whitewashing, internal two coat putty with acrylic painting, external painting with apex ultima/equivalent paint, all steelwork must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification with adequate LED lights for the compound. FFL above 60 cm nearest road level. |
| 45 | DISTRIBUTIONS SYSTEM :- Supply of following sizes (D.I.) pipes for rising main system conforming to latest/relevant I.S. 8329/2000 Specifications with all jointing materials such as MJ joints, tee ,bends, all required mild steel fabrication works (if MS fabrication used, its proper protection treatment against corossion must be done) and all DI specials conforming to latest /relevant I.S. specifications, suitable for D.I pipes, as per IS‐1239 /2000 and IS 8329/2000 or their latest amendment & CPHEEO latest amendments including F.O.R. destinations rate per metre in Rs., anywhere in U.P. including cost of SBR Rubber Gasket per pipe length & iniclusive of all Taxes & Duties, Third Party Inspection Charges, Packing & Forwarding Charges, Transit Insurance Charges, Road Transportation Charges etc. with loading, unloading and Carting up to store,HYDRAULIC TESTING AS PER CPHEEO MANUALS latest amendments also including specials, carting, laying & jointing in proper trench for these pipes all complete as per instructions of Engineer ‐in ‐ charge.Note- Only SBR Rubber Gaskets to be used as per IS- 5382 and IS- 12820. |
| 46 | DI pipe Class K-7 (IS-8329/2000) |
| 47 | 80 mm |
| 48 | 100 mm |
| 49 | 125 mm |
| 50 | 150 mm |
| 51 | 200 mm |
| 52 | 250 mm |
| 53 | 300 mm |
| 54 | 350 mm |
| 55 | Earth work in ordinary soil, In Moorum /Kankar / Shingle, In Soft/Medium rock. Etc. loam, clay or sand with lift upto 1.50M and lead upto 200m, barricading, Refilling the soil as required, incluidng depositing in layers not exceeding 150 mm, watering and compaction to 95% of the Standard proctor density, level dressing, including supply of all lebour, T&P etc. required for completion of the work. Ramming of excavated earth into the trenches and disposal of surplus earth upto 8KM. and restoration of damaged overhead & underground utility.The trenches shall be properly barricaded and fenced off wherever necessary. RED FLAGS AND CAUTION BOARDS during day and red lights during night shall be displayed so as to avoid any accidents.. its includes provision of making of alignment on city roads, making trial pits to investigated location of various under ground services like telephone cables, electric cable, existing pipe lines and sewer line etc. arrangemnts for diversion of traffic and associated marks etc. with supply of all necessary equipments, materials, labour and T&P etc. complete required for completion of work. |
| 56 | In Ordinary Soil |
| 57 | In Moorum /Kankar / Shingle etc & incl. replace of ordinary soil. |
| 58 | In Soft/Medium rock. & incl. replace of ordinary soil. |
| 59 | Supply of following types of fittings including railway freight, cartage from store to site of work,lowering, carting, fixing , jointing all taxes and duties etc. complete. CI D/F Sluice Valves, Scour Valve Class-I as per IS 780 (1969) & CPHEEO MANUALS latest amendments suitable for a working pressure of 16 Kg / Sq.Cm. (using without galendori valves) |
| 60 | 80 mm |
| 61 | 100 mm |
| 62 | 125 mm |
| 63 | 150 mm |
| 64 | 200 mm |
| 65 | 250 mm |
| 66 | Scour Valve 100mm dia |
| 67 | Fire Hydrant 80mm Dia |
| 68 | Air Valve 25mm Dia |
| 69 | Supply of all types of materials and construct following chambers with extra heavy duty ms cover grade-35as per type design with supply of all labour, T&P etc. completed. |
| 70 | S.V. Chamber (Surface Box Type) |
| 71 | S.V. Chamber (Masonary Type) |
| 72 | Air Valve Chamber |
| 73 | Fire Hydrant Chamber |
| 74 | Dismantling of following type of road surface including stacking of serviciable material and disposal of unsericeable material within the limit of npp upto 8km distance including supply of all labour T&P etc. required for proper completion ofthe work as per instructions of Engineer ‐in ‐charge. |
| 75 | Bituminous Road |
| 76 | C.C. Road |
| 77 | Interlocking Road |
| 78 | Re-instatement of following type of road surface of PWD/ UPJN specifications including supply of all materials, labour, T&P etc. required for proper completion of the work as per instructions of Engineer ‐in ‐charge. |
| 79 | Bituminous surface (20cm sand, 20cm GSB, 20cm WMM, 5 cm to 8 cm DBM, 3cm to 4 cm B.C.) payment made upto WMM- 50%, DBM- 30% and BC with testing in NABL aprooved lab/PWD- 20% |
| 80 | C.C. Road in M25 grade, minimum thickness 15cm on 15cm sand & 20cm GSB filling base. |
| 81 | Interlocking Road (50% new Interlocking bricks M-30 grade, 80 mm thick on 10cm sand & 10cm GSB filling base) |
| 82 | Providing and laying of GSB for reinstatement of earthen road (Shoulder) including dressing, watering, ramming etc. complete. |
| 83 | Provision for NALLA/CULVERT CROSSING from250mm to 350MM DIA PIPE CROSSING including all material, for casing etc. all complete work. With concreting thrust block M20 grade using inlcuding supply of DI K-9 Pipe and laying with MS Fabrication and DI Specals. |
| 84 | Provision for NALLA/CULVERT CROSSING UP TO 200MM DIA PIPE CROSSING including all material, for casing etc. all complete work. With concreting thrust block M20 grade using inlcuding supply of DI K-9 Pipe and laying with MS Fabrication and DI Specals. |
| 85 | THRUST BLOCK |
| 86 | Supply of all materials,labour, and T & P etc. and construct R.C.C.(M-25 grade) thrust blocks. Including mild steel works(1% ) all complete as per design for following size and instructions of Engineer ‐in ‐ charge. |
| 87 | 80mm ( Size 0.45m x 0.45m x 0.45m) |
| 88 | 100mm ( Size 0.55m x 0.55m x 0.55m) |
| 89 | 125mm ( Size 0.60m x 0.60m x 0.60m) |
| 90 | 150mm ( Size 0.70m x 0.70m x 0.70m) |
| 91 | 200mm ( Size 0.85m x 0.85m x 0.85m) |
| 92 | 250mm ( Size 1.00m x 1.00m x 1.00m) |
| 93 | Shifting of Utility as a water supply pipe line, sewer line, drainage pipe,brick drainage nali,Telephone line/pole, Electric pole/ cable, tree cutting etc. all complete work including all material, Labour, T&P etc for whole project. (all overhead / underground utility) |
| 94 | Crossing of Road Laying of pipe line 8mm thick MS carrier pipe 200mm to 300mm dia and 12 mm thick MS Casing pipe 600 mm dia by trenchless technology (Auger Boring Method) For highway. Provision for Crossing and laying of pipe line of both side at State/National Highway and payment to state/NHAI Authority for permission of National Highway crossing:- Survey site Investigation Planning , design Drawings, excavation, dismentaling, road restoration & other all utility restoration( as per required) as per NATIONAL HIGHWAY standard as per MORTH Road manual and vetting / checked from State Road/ NH DIV. PWD/NHAI/UPSHA/ PWD/ Divisional Office and taking all NOC CHARGES.(incl. noc fees, licence fees, security amount) for trenchless crossing of National highway road , Road for required dia Rising main pipe with casing pipe as required for proper completion of work also including security money deposited to State Road department and Execution of all work in the present of State Road staff / Engineers including supply of required dia MS carrier pipe and required size of MS casing pipe as per drawing and as per (IS:3589 & made from confining to IS:2062) with 750 Micron th. food grade coating internally and 750 TH. MICRONE anti corrosive bituminous paint externally by trenchless technology method at an average depth 3.60 mtr from normal ground level up to top of casing pipe including excavation & sand filling of Pit, Dewatering arrangement, Supporting system for soil, also including supply and fixing of 2 no Sluice valve ISI Mark, construction of sluice valve chamber etc. all complete work including supply & fixing specials in carrier pipe over main pipe, as per specification given in the bid documents including supply of all materials, labour T&P etc. for proper completion of work as per instruction of Engineer. and concerned department. (CASING- 600MM (id) MS PIPE 12 MM THICK & CARRIER PIPE- AS PER REQUIRED DESIGN) INCL.3M C/C SPACER |
| 95 | Crossing of Railway Line Laying of pipe line 8mm thick MS carrier pipe 200mm to 300mm dia and 12 mm thick MS Casing pipe 600 mm dia by trenchless technology (Auger Boring Method) For Railway.Provision for Railway Crossing:- Survey site Investigation, Planning , design Drawings as per Railway Divisional Office and taking NOC & permission with all fee/ security/ liecence fee/ for NOC from RBCS PORTAL for trenchless crossing of Railway track, required dia DISTRIBUTION main pipe with casing pipe ( 600 MM DIA (ID) MS PIPE TH. 12MM) as required for proper completion of work also including security money deposited to Railway department and Execution of all work in the present of Railway staff / Engineers including of supply of required dia MS carrier pipe and required size of MS casing pipe as per drawing and as per (IS:3589 & made from confining to IS:2062) with min 750 microne th. foodgrade epoxy coating internally & anti corrosive bituminous paint externally by trenchless technology method at an average depth 5.00 mtr. from normal ground level up to top of casing pipe including excavation &sand filling & restoration of Pit, Dewatering arrangement, Supporting system for soil, also including supply and fixing of 2 no Sluice valve ISI Mark, construction of sluice valve chamber with frame extra heavy duty MS cover etc. all complete work including supply & fixing specials in carrier pipe over main pipe, as per specification given in the bid documents including supply of all materials, labour T&P etc. for proper completion of work as per instruction of Engineer. all works excution as per guidlines of ministry of RAILWAY (CASING- 600MM (id) MS PIPE 12 MM THICK & CARRIER PIPE (8mm th.)- AS PER REQUIRED DESIGN) INCL.3M C/C SPACER |
| 96 | Making House Connection should be done from distribution pipe line to outer wall of house or 2.0 m inside the boundary wall with provision of tap including supply of 7.0 m HDPE Pipe(is code 4984 with latest amendments) 20mm dia, PN- 12.5, PE-100, SDR-11 (0.6m depth below ground level), and 4.0m 15mm dia (ID) G.I. Pipe, Class-B and keeping the G.I. pipe atleast 1.0m in height above the G.L. as per department type design and Drowing including supply of specials, saddle, clamps etc. of suitable size, ISI mark 6mm BRASS FERRULE conforming to latest/relevant I.S. 2692/1989 or their latest amendments, Heavy BRASS Tap, all Materials, labours, T&P etc. complete, Dismentelling of all type of road surface, breaking of all type of floor, wall, and disposal of unserviceable materials up to 8km. Excavation pit/trench, cutting of pipe, Bailing out of water, carting and lowering them unto the already prepared trenches, fixing in position and jointing them with pipelines and testing etc, Grounting by CC 150mm x 150mm x 150mm size in M20, Restoration of pit, trench/Road (as site condition NON PAVED, BOE, CC, INTERLOCKING BRICKS, Bituminous road, RAMP, DRAIN, WALL, FLOOR etc.) as per PWD/UPJN SPECIFICATION and 3 nos GPS location colour photographs submitted after complition of work. Also including GIS Based Survey to collect all required data in projected area Nagar Panchayat Chopan for proper complition of work as per drawing and. As per Instruction of Engineer in charge as per drawing. Payment make after completion of work up to household 70%, RETORATION & GROUTTING-10% and 10% submitted of photographs after Testing and Commisioning,5%after GIS based all collected required data and 3 NOS GPS using colour photographs & geo tagging on google maps - 5% after handover to NP Chopan of all remaining work. |
| 97 | New Connections with New pipe line. |
| 98 | Shifting of Existing House Connection from Old Pipe line to New Pipe Line |
| 99 | Staff quarterProvide all materials, labour T&P etc. and construct Double RooM staff quarter with store room, bathroom, latrine & kitchen as per departmental specification and drawing Including excavation in foundation, PCC(M-15), Brick Work (1:6), 20mm thick DPC, RCC(M-20), 12mm thick plaster(1:4), Floring with tiles, Painting, 04 nos chair, 01 No. Table, 01 No. Almirah (Godrej make) electrification (internal & external) , Wiring , 20 LPM capacity RO, water supply & sanitary etc complete work. all materials, labours, t& p etc.( RCC FRAME STRUCTURE 3.6 M HEIGHT With plinth not less from nearest road level than 0.6 M) |
| 100 | Construction of 1.8 m high and 115mm thick boundary wall ( Zone-1 , Zone-4) with 230 mmx 230 mm RCC BEAM, 230 mmx230 mm thick pillar, 50*50*6mm size MS angle FIXING IN RCC PILLAR with 3 Layer barbed bars made in RCC in 1:1.5:3 the spacing between two pillar should not be more than 2.0 m c/c and depth of rcc footing (1.2*1.2*.3)m not less than 1.2m , and the depth of foundation should not be less than 0.60m below N.G.L. and plinth height should be kept 0.60m above nearest road level, Brick Work in 1:4 and 12mm thick plaster with cement and coarse sand in the ratio of 1:4, painting with weatherproof approved paint, at the site of water works as per departmental type design and drawing, as per specifications given in the bid document and pwd/upjn, including supply of all materials, labour T&P etc.for proper completion of the all work as per instructions of Engineer ‐in ‐ charge. |
| 101 | Supply and fixing of 3.6 m x 1.80 m MS gate including fabrication and supply of steel and construction of RCC pillars of size 1.8m x 0.23m x 0.23m in M25 grade with ornamental brick work 115mm thick around RCC pillers with elctrification and lighting arrangement, brick work in foundation 1:4 cement & fine sand upto plinth, as per departmental type design and drawing and as per specifications of pwd/upjn and laid down in the bid document, including supply of all material, labour,T&P etc.required for proper completion of the work as per instructions of Engineer‐in‐charge. |
| 102 | MS Gate (size 3.60 m X 1.80 m) minimum weight 1.60 Qtl |
| 103 | MS Wicket gate (size 1.20 m X 1.80 m) minimum weight0.50 Qtl |
| 104 | Provision for arboriculture/ greeneries/ plantation for development of water works, including earth filling ( REQUIRED all nonusing area) with pipe sprinkling arrengments. For ZONAL WATER WORKS |
| 105 | Construction of Cement Concrete USING 20 CM TH. M25 grade using concrete type & 30 cm GSB BASE approach road including supply of all materials, labour, tools and plants etc. complete. |
| 106 | Supply and Construction of roof top rain water & ground water harvesting system including all required materials, labour, tools and plants etc. complete. (150 MM DIA PVE PIPE PN6 boring depth 2nd layer strata) |
| 107 | PUMPING PLANT AT INTAKE WELLSupply of vertical turbine oil lubricated raw water pump set along with V.H.S. squairal cage induction motor with shaft, 30 meter column pipe, (tentative it will be decided as per site required) thrust bearing, motor stool foundation bolt etc. suitable to operate 415 volt, 3 phase, 50Hz, AC Supply (2 W+ 1 S). LPM - 2350 Head-35 M with all other accessories complete in all respect. |
| 108 | CE/UL certified PLC/RTU with redundant CPU and power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU and power supply with analog /digital parameter and features as specified for each zps/oht to store and trasmitt data on GSM backbone , RTU/PLC designed with logic to transfer data at multiple station specified in tender document |
| 109 | GSM/GPRS based wireless communication system for RTU capable to transfer and gather data from remote sites to control stations. All accessories included with signal enhancer, antennan etc. |
| 110 | Intelegent Energy meter with memory RTC and 2 serial parts integrated with RTU |
| 111 | Motor operated sluice valve with actuator complete in all respect |
| 112 | Electric motor operated sluice valve 200mm dia or suitable size along with actuator for delivery pipe of pump. |
| 113 | Electric motor operated sluice valve 250mm or suitable size dia along with actuator for common header. |
| 114 | Auto phase reversal unit suitable with inbuilt time delay & enclose of 100 Amp or suitable rating. |
| 115 | Radar type level with RTU communication at Intakewell. |
| 116 | Pressure Transmitter with manual pressure gauge at common header for each pump - 4 Nos |
| 117 | Isolation transformer & surge arrestor. |
| 118 | CE/UL certifiedd 7 inch HMI touch screen suitable to communication with PLC/RTU for local display and control. |
| 119 | Control cabling for intake well including all power and control cable for all equipment (1.5sq mm, 10cx1sq mm, 2cx1sq mm other required items for pump set. |
| 120 | Security serveilliance camera IP with recorder |
| 121 | ELECTRO MAGNETIC FLOW METER |
| 122 | Provision of Electro magnetic flow meter suitable to measure the water discharge and to be fitted in common header of 250mm dia. Or suitable size |
| 123 | FLOW SENSOR |
| 124 | Type - Pulsed DC |
| 125 | End connection- Flanged of Carbon steel |
| 126 | Flange rating - PN 16 size 250 mm./ suitable size |
| 127 | Electrode - SS 316 |
| 128 | Lining Material - Hard rubber |
| 129 | Protection category - IP 68 |
| 130 | Measuring Accuracy- + 5% of measured |
| 131 | Valve inclusive of linearity repeatability pressure effect and Hystrusues between 1 to 3 meter per second. |
| 132 | Sensor Housing - SS 304 with fully welded construction |
| 133 | Connection/ Junction Box - SS 304 |
| 134 | Earthing only grounding rings required |
| 135 | FLOW TANSMITTER CONVERTOR |
| 136 | Type - Micro processor based modular desing |
| 137 | Display - 3 line back lit LDC for indication of actual flow rate forward reverse sum totolizer. |
| 138 | Protection category - IP 65 |
| 139 | Enclosure - DI - Cast Aluminium with poly urethan with glass window. |
| 140 | Programming- Through three key pad as front facia. |
| 141 | Power Supply - 230 volt 50 HZ AC |
| 142 | Cable Gland - ½ NPT |
| 143 | Mounting - Wall mounted |
| 144 | Maximum Sepration - Upto 300 m between sensor and transmeter without any signal boosters. |
| 145 | Terminals - shock-Hazard-protected push lock terminal. |
| 146 | Error Indetification : 0.3, 6/22 MA |
| 147 | Flow Indicator Totalizer - 3½ digit IED display with 6 digit electro mechanical Totalizer. |
| 148 | MAIN PIPING & VALVES INCLUDING COMMON HEADER :- |
| 149 | Size of Delivery of pump 200mm dia length or as per site requirement |
| 150 | Size of Common header of 250mm dia. Length or as per site requirement |
| 151 | Supply of following |
| 152 | CI D/F Reflux Valve 200 mm dia or suitable size -3 Nos. |
| 153 | CI D/F Tee 250x250x200 mm dia or suitable size. -3 Nos. |
| 154 | D/F distance piece 200 mm dia. or suitable size 1.00 m. long - 3 Nos. |
| 155 | D/F distance piece 250 mm dia or suitable size . 1.50 m. long - 3 Nos. |
| 156 | D/F distance piece 250 mm dia or suitable size 3.00 m. long - 3 Nos. |
| 157 | Dismantling joint 200 mm dia or suitable size - 3 Nos. |
| 158 | Dismantling joint 250 mm dia or suitable size for common header - 1 No.Reflex valve 250mm dia or suitable size 1No. |
| 159 | Nut-bolts, bend,rubber packing (as required) |
| 160 | Any other Item required for proper installation of above pumps. - 1 Job. |
| 161 | CABLE FOR INCOMING PANEL & PUMPS :- |
| 162 | Suitable size P.V.C. Armoured Alluminium conductor cable from outgoing of transformer to L.T. incoming Panel and for power wring of pumping plant. |
| 163 | EOT crane |
| 164 | Provision of E.O.T. crane of 3 Ton capacity along with gantry girder and chainpully block and geared trolly suitable for span and 12 meter or suitable higher capacity clear lift complete in all respect for circular pump house, suitable for travelling length. |
| 165 | POWER WIRING : |
| 166 | Power wiring complete for L.T. panel, starter and for 3 No. pump set etc all complete. |
| 167 | EARTHING : |
| 168 | Provision for double plate earthing for 3 nos. of electric motors, starters, panels etc. excavation of earthing pit of required size supply and burrying of 600 mm x600 mm size 3mm thick copper earth plate vertically errected for earthing with its top at least 3 meter from ground level completed with 32 mm G.1. perforated pipes and funnel for watering, laying and fetting of earthing strip, CI boxes hinged cover masonary, laying alternate layers of characoal / coak and salt at least 150 mm thick each layer complete in all respect. |
| 169 | PAINTING |
| 170 | Provision for painting of all the pumps set, main piping and valves, panels etc. installed in the pump house with three coats by enamel paint. |
| 171 | INSTALLATION OF \\" SCADA\\" |
| 172 | Installation of SCADA system, to control the 3 set of pumping plant including testing and commissioning etc. |
| 173 | INSTALLATION AND COMMISSIONING |
| 174 | Installation and commissioining of all 3 no.pumping plants along with L.T. panels distribution boards, switch gear control panels, starter etc laying & jointing of column pipes, delivery pipes, common header also commissioning of pumping plant. |
| 175 | Electrification for pump house and premises. |
| 176 | Electrification of pump house and campus with copper conductor wire concealed with the all material laboure etc. |
| 177 | Fire Extinguisher capasity 4.5 Kg co2 |
| 178 | 12.5 mm thick electric resistance rubber sheet as per BIS for LT Panels |
| 179 | Supply and fixing of exhaust fans of 18\\" size 1450rpm of GEC/equivalent make complete in all respect. |
| 180 | Pole mounted solar based LED light (As per SOR 2018) |
| 181 | PUMPING PLANTSupply of Desilting pump set,nut bolt ,rubber packing etc. LPM - 250 Head - 40,(1W+1S) |
| 182 | SWITCH GEAR WITH starter |
| 183 | Supply of suitable capacity stater for above pump set |
| 184 | supply of 1100 volt grade copper submersible cable 3x16mm |
| 185 | MS column pipe 100mm Dai or suitable size. |
| 186 | CI/DF Sluice valve 100mm Dai or suitable size |
| 187 | CI/DF Reflex valve 100mm dai or suitable size |
| 188 | CI/DF Bend 100 mm dai or suitable size |
| 189 | SS guide pipe of 40mm dai. or suitable size |
| 190 | Dismentaling joint 100 mm |
| 191 | Pressure gauge with stop cock. |
| 192 | Installation ,testing and commissioning of pumping plant. |
| 193 | At C.W.R. WATER TREATMENT PLANT CWR ZONE-1 |
| 194 | PUMPING PLANTSupply of submerged VT/ submerged pumping plant along with suitable motor 415 volt ± 10%, 3phase,50 Hz AC supply with required size and lenghth, Column pipe, Foundation, guide pipe, Auto coupling arrangement if required and other necessary accessories to complete the work, capacity LPM - 2200 Head-50 M (both tentative it will be decided as per site condition) |
| 195 | CE/UL certified PLC/RTU with redudant CPU and power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redudant CPU and power supply with analog /digital parameter and features as specified for each zps/oht to store and trasmitt data on GSM backbone , RTU/PLC designed with logic to transfer data at multiple statins as specified in tender document |
| 196 | GSM/GPRS based wireless communication system for RTU capable to transfer and gather data from remote sites to control stations. All accessories included with signal enhancer, antennan etc. |
| 197 | Intelegent Energy meter with memory RTC and 2 serial parts integrated with RTU |
| 198 | Motor operated sluice valve with actuator complete in all respect- |
| 199 | Electric motor operated sluice valve 150 mm dia or suitable size along with actuator for delivery pipe of pump. |
| 200 | Electric motor operated sluice valve 250mm dia or suitable size along with actuator for common header. |
| 201 | Auto phase reversal unit suitable with inbuilt time delay & enclose of 100 Amp rating or suitable rating. |
| 202 | Rador type level sensor for CWR. |
| 203 | Pressure Transmitter with manual pressure gauge at each pump and common header. |
| 204 | CE/UL certifiedd 7 inch HMI touch screen suitable to communication with PLC/RTU for local display and control. |
| 205 | Security serveilliance camera IP with recorder |
| 206 | CE/UL certified Radar type Level Transmitter for OHT |
| 207 | Isolation transformer & surge arrestor. |
| 208 | Cable (1.5sq mm, 10cx1sq mm, 2cx1sq mm other required itmes for installation of SCADA system. |
| 209 | ELECTRO MAGNETIC FLOW METER |
| 210 | Provision of Electro magnetic flow meter suitable to measure the water suitable discharge be fitted in common header of 250 mm dia or suitable size having following specification |
| 211 | FLOW SENSOR |
| 212 | Type - Pulsed DC |
| 213 | End connection- Flanged of Carbon steel |
| 214 | Flange rating - PN 16 size 250 mm. or suitable size |
| 215 | Electrode - SS 316 |
| 216 | Lining Material - Hard rubber |
| 217 | Protection category - IP 68 |
| 218 | Measuring Accuracy- + 5% of measured |
| 219 | Sensor Housing - SS 304 with fully welded construction |
| 220 | Connection/ Junction Box - SS 304 |
| 221 | Earthing only grounding rings required |
| 222 | FLOW TANSMITTER CONVERTOR |
| 223 | Type - Micro processor based modular desing |
| 224 | Display - 3 line back lit LDC for indication of actual flow rate forward reverse sum totolizer. |
| 225 | Protection category - IP 65 |
| 226 | Enclosure - DI - Cast Aluminium with poly urethan with glass window. |
| 227 | Programming- Through three key pad as front facia. |
| 228 | Power Supply - 230 volt 50 HZ AC |
| 229 | Cable Gland - ½ NPT |
| 230 | Mounting - Wall mounted |
| 231 | Maximum Sepration - Upto 300 m between sensor and transmeter without any signal boosters. |
| 232 | Terminals - shock-Hazard-protected push lock terminal. |
| 233 | Error Indetification : 0.3, 6/22 MA |
| 234 | Flow Indicator Totalizer - 3½ digit IED display with 6 digit electro mechanical Totalizer. |
| 235 | MAIN PIPING & VALVES INCLUDING COMMON HEADER :- |
| 236 | Size of Delivery of pump 150mm dia length or as per site requirement |
| 237 | Size of Common header of 250mm dia. Length or as per site requirement |
| 238 | Supply of following |
| 239 | CI D/F Reflux Valve 150 mm dia or suitable size - 3 Nos. |
| 240 | CI D/F Tee 250x250x150 mm dia or suitable size. - 3 Nos. |
| 241 | D/F distance piece 150 mm dia. 1.00 m. long - 3 Nos. |
| 242 | D/F distance piece 250 mm dia. 1.50 m. long - 3 Nos. |
| 243 | D/F distance piece 250 mm dia. 3.00 m. long - 3 Nos. |
| 244 | Dismantling joint 150 mm dia or suitable size - 3 Nos. |
| 245 | Dismantling joint 250 mm dia or suitable size for common header - 1 No.,Reflex valve 250mm dia 1No. |
| 246 | Nut-bolts, rubber packing (as required) |
| 247 | Any other Item required for proper installation of above pumps. - 1 Job. |
| 248 | POWER WIRING CABLE FOR INCOMING PANEL & PUMPS :- |
| 249 | Supply and laying of 1100 volt grade 70 mm2 x 3½ core/ suitable size P.V.C. Armoured Alluminium conductor cable from outgoing of transformer to L.T. incoming Panel and for power wring of pumping plant. |
| 250 | EARTHING : |
| 251 | Provision for double plate earthing for 3 nos. of electric motors, starters, panels etc. excavation of earthing pit of required size supply and burrying of 600 mm x600 mm size 3mm thick copper earth plate vertically errected for earthing with its top at least 3 meter from ground level completed with 32 mm G.1. perforated pipes and funnel for watering, laying and fetting of earthing strip, CI boxes hinged cover masonary, laying alternate layers of characoal / coak and salt at least 150 mm thick each layer complete in all respect. |
| 252 | EOT crane |
| 253 | Provision of E.O.T. crane of 2 Ton capacity along with gantry girder and chainpully block and geared trolly suitable for span and 6 meter or suitable highter clear lift complete in all respect for circular pump house, suitable for travelling length. |
| 254 | PAINTING |
| 255 | Provision for painting of all the pumps set, main piping and valves, panels etc. installed in the pump house with three coats by enamel paint. |
| 256 | INSTALLATION OF \\" SCADA\\" |
| 257 | Installation of SCADA system, to controle the 3 set of pumping plant including testing and commissioning etc. |
| 258 | INSTALLATION AND COMMISSIONING |
| 259 | Installation of all 3 pumping plants along with L.T. panels distribution boards, switch gear control panels, starter etc laying & jointing of column pipes, delivery pipes, common header also commissiong of pumping plant. |
| 260 | Pole mounted solar based LED light For WTP Campus (As per SOR 2018) |
| 261 | C.W.R. ZONE-1 to OHT Zone-1 |
| 262 | PUMPING PLANTSupply of submerged VT/ submerged pumping plant along with suitable motor 415 volt ± 10%, 3phase,50 Hz AC supply with required size and lenghth, Column pipe, Foundation, guide pipe, Auto coupling arrangement if required and other necessary accessories to complete the work, capacity LPM - 3100 Head-40 M (both tentative it will be decided as per site condition) |
| 263 | CE/UL certified PLC/RTU with redundant CPU and power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU and power supply with analog /digital parameter and features as specified for each zps/oht to store and trasmitt data on GSM backbone , RTU/PLC designed with logic to transfer data at multiple station specified in tender document |
| 264 | GSM/GPRS based wireless communication system for i RTU capable to transfer and gather data from remote sites to control stations. All accessories included with signal enhancer, antennan make for abbove ITRU. |
| 265 | Intelegent Energy meter with memory RTC and 2 serial parts integrated with RTU |
| 266 | Motor operated sluice valve with actuator complete in all respect- |
| 267 | Electric motor operated sluice valve 200 mm dia along with actuator for delivery pipe of pump. |
| 268 | Electric motor operated sluice valve 200 mm dia along with actuator for common header. |
| 269 | Auto phase reversal unit suitable with inbuilt time delay & enclose of 100 Amp rating or suitable rating. |
| 270 | Rador type level sensor |
| 271 | CE/UL certifiedd 7 inch HMI touch screen suitable to communication with PLC/RTU for local display and control. |
| 272 | Security serveilliance camera IP with recorder |
| 273 | Isolation transformer & surge arrestor. |
| 274 | Pressure Transmitter with manual pressure gauge at each pump and common header - 3 Nos |
| 275 | Complete cabling for 8 no. pump set and other required itmes . |
| 276 | ELECTRO MAGNETIC FLOW METER |
| 277 | Provision of Electro magnetic flow meter suitable to measure the water discharge to be fitted in common header of 200 mm dia or suitable size having following specification |
| 278 | FLOW SENSOR |
| 279 | Type - Pulsed DC |
| 280 | End connection- Flanged of Carbon steel |
| 281 | Flange rating - PN 16 size 200 mm. |
| 282 | Electrode - SS 316 |
| 283 | Lining Material - Hard rubber |
| 284 | Protection category - IP 68 |
| 285 | Measuring Accuracy- + 5% of measured |
| 286 | Valve inclusive of linearity repeatability pressure effect and Hystrusues between 1 to 3 meter per second. |
| 287 | Sensor Housing - SS 304 with fully welded construction |
| 288 | Connection/ Junction Box - SS 304 |
| 289 | Earthing only grounding rings required |
| 290 | FLOW TANSMITTER CONVERTOR |
| 291 | Type - Micro processor based modular desing |
| 292 | Display - 3 line back lit LDC for indication of actual flow rate forward reverse sum totolizer. |
| 293 | Protection category - IP 65 |
| 294 | Enclosure - DI - Cast Aluminium with poly urethan with glass window. |
| 295 | Programming- Through three key pad as front facia. |
| 296 | Power Supply - 230 volt 50 HZ AC |
| 297 | Cable Gland - ½ NPT |
| 298 | Mounting - Wall mounted |
| 299 | Maximum Sepration - Upto 300 m between sensor and transmeter without any signal boosters. |
| 300 | Terminals - shock-Hazard-protected push lock terminal. |
| 301 | Error Indetification : 0.3, 6/22 MA |
| 302 | Flow Indicator Totalizer - 3½ digit IED display with 6 digit electro mechanical Totalizer. |
| 303 | MAIN PIPING & VALVES INCLUDING COMMON HEADER :- |
| 304 | Size of Delivery of pump 200mm dia length or as per site requirement |
| 305 | Size of Common header of 200mm dia. Length or as per site requirement |
| 306 | Supply of following |
| 307 | CI D/F Reflux Valve 200 mm dia or suitable size - 2 Nos. |
| 308 | CI D/F Tee 200x200x200 mm dia or suitable size. - 2 Nos. |
| 309 | D/F distance piece 200 mm dia or suitable size. 1.00 m. long - 2 Nos. |
| 310 | D/F distance piece 200 mm dia or suitable size. 1.50 m. long - 2 Nos. |
| 311 | D/F distance piece 200 mm dia or suitable size. 3.00 m. long - 2 Nos. |
| 312 | Dismantling joint 200 mm dia or suitable size. - 2 Nos. |
| 313 | Dismantling joint 200 mm dia or suitable size for common header - 1 No.Reflex valve 200mm dia or suitable size 1 No. |
| 314 | Nut-bolts, Bend ,rubber packing (as required) |
| 315 | Any other Item required for proper installation of above pumps. - 1 Job. |
| 316 | CABLE FOR INCOMING PANEL & PUMPS :- |
| 317 | Suitable size P.V.C. Armoured Alluminium conductor cable from outgoing of transformer to L.T. incoming Panel and for power wring of pumping plant. |
| 318 | EARTHING : |
| 319 | Provision for double plate earthing for 2 nos. of electric motors, starters, panels etc. excavation of earthing pit of required size supply and burrying of 600 mm x600 mm size 3mm thick copper earth plate vertically errected for earthing with its top at least 3 meter from ground level completed with 32 mm G.1. perforated pipes and funnel for watering, laying and fetting of earthing strip, CI boxes hinged cover masonary, laying alternate layers of characoal / coak and salt at least 150 mm thick each layer complete in all respect. |
| 320 | PAINTING |
| 321 | Provision for painting of all the pumps set, main piping and valves, panels etc. installed in the pump house with three coats by enamel paint. |
| 322 | INSTALLATION OF \\" SCADA\\" |
| 323 | Installation of SCADA system, to controle the 4 set of pumping plant including testing and commissioning etc. |
| 324 | INSTALLATION AND COMMISSIONING |
| 325 | Installation of all 2 pumping plants along with L.T. panels distribution boards, switch gear control panels, starter etc laying & jointing of column pipes, delivery pipes, common header also commissiong of pumping plant. |
| 326 | Pole mounted solar based LED light For Campus (As per SOR 2018) |
| 327 | CWR ZONE 1 FOR OHT ZONE-2 |
| 328 | PUMPING PLANTSupply of submerged VT/ submerged pumping plant along with suitable motor 415 volt ± 10%, 3phase,50 Hz AC supply with required size and lenghth, Column pipe, Foundation, guide pipe, Auto coupling arrangement if required and other necessary accessories to complete the work, capacity LPM - 900 Head-40 M (both tentative it will be decided as per site condition) |
| 329 | Motor operated sluice valve with actuator complete in all respect- |
| 330 | Size of Delivery of pump 100mm dia length or as per site requirement |
| 331 | Size of Common header of 100mm dia. Length or as per site requirement |
| 332 | Pressure Transmitter with manual pressure gauge at each pump and common header - 3 Nos |
| 333 | Rador type level sensor |
| 334 | ELECTRO MAGNETIC FLOW METER |
| 335 | Provision of Electro magnetic flow meter suitable to meassure the sutabile discharge to be fitted in common header of suitable size having following specification complete in all respect. |
| 336 | FLOW SENSOR |
| 337 | Type - Pulsed DC |
| 338 | End connection- Flanged of Carbon steel |
| 339 | Flange rating - PN 16 size 100 mm. |
| 340 | Electrode - SS 316 |
| 341 | Lining Material - Hard rubber |
| 342 | Protection category - IP 68 |
| 343 | Measuring Accuracy- + 5% of measured |
| 344 | Valve inclusive of linearity repeatability pressure effect and Hystrusues between 1 to 3 meter per second. |
| 345 | Sensor Housing - SS 304 with fully welded construction |
| 346 | Connection/ Junction Box - SS 304 |
| 347 | Earthing only grounding rings required |
| 348 | FLOW TANSMITTER CONVERTOR |
| 349 | Type - Micro processor based modular desing |
| 350 | Display - 3 line back lit LDC for indication of actual flow rate forward reverse sum totolizer. |
| 351 | Protection category - IP 65 |
| 352 | Enclosure - DI - Cast Aluminium with poly urethan with glass window. |
| 353 | Programming- Through three key pad as front facia. |
| 354 | Power Supply - 230 volt 50 HZ AC |
| 355 | Cable Gland - ½ NPT |
| 356 | Mounting - Wall mounted |
| 357 | Maximum Sepration - Upto 300 m between sensor and transmeter without any signal boosters. |
| 358 | Terminals - shock-Hazard-protected push lock terminal. |
| 359 | Error Indetification : 0.3, 6/22 MA |
| 360 | Flow Indicator Totalizer - 3½ digit IED display with 6 digit electro mechanical Totalizer. |
| 361 | MAIN PIPING & VALVES INCLUDING COMMON HEADER :- |
| 362 | Size of Delivery of pump 100mm dia length or as per site requirement |
| 363 | Size of Common header of 100mm dia. Length or as per site requirement |
| 364 | Supply of following |
| 365 | CI D/F Reflux Valve 100 mm dia or suitable size - 2 Nos. |
| 366 | CI D/F tee 100x100x100 mm dia or suitable size. - 2 Nos. |
| 367 | D/F distance piece 100 mm dia or suitable size. 1.00 m. long - 2 Nos. |
| 368 | D/F distance piece 100 mm dia or suitable size. 1.50 m. long - 2 Nos. |
| 369 | D/F distance piece 100 mm dia. or suitable size 3.00 m. long - 2 Nos. |
| 370 | Dismantling joint 100 mm dia or suitable size. - 1 Nos. |
| 371 | Dismantling joint 100 mm dia. or suitable size - 1 No.Reflex valve 150mm dia 1No. |
| 372 | Nut-bolts, bend,rubber packing ( as required) |
| 373 | Any other Item required for proper installation of above pumps. - 1 Job. |
| 374 | Accessories for pump house : |
| 375 | Fire extingushier cinfirming to BIS of 3 Kg Co2 gas type |
| 376 | 12.5 mm/25mm thich electric resistance rubber sheet as per BIS for LT Panels |
| 377 | E.O.T CRANE |
| 378 | Provision of E.O.T. crane of 2 Ton capacity along with gantry girder and chainpully block and geared trolly suitable for span and 6 meter or highter rating clear lift complete in all respect for circular pump house, suitable for 6 meter travelling length. |
| 379 | CABLE FOR INCOMING PANEL & PUMPS :- |
| 380 | Suitable size P.V.C. Armoured Alluminium conductor cable from outgoing of transformer to L.T. incoming Panel and for power wring of pumping plant. |
| 381 | EARTHING : |
| 382 | Provision for double plate earthing fo2 nos. of electric motors, starters, panels etc. excavation of earthing pit of required size supply and burrying of 600 mm x600 mm size 3mm thick copper earth plate vertically errected for earthing with its top at least 3 meter from ground level completed with 32 mm G.1. perforated pipes and funnel for watering, laying and fetting of earthing strip, CI boxes hinged cover masonary, laying alternate layers of characoal / coak and salt at least 150 mm thick each layer complete in all respect. |
| 383 | Electrification for pump house and premises. |
| 384 | Electrification of pump house and campus with copper conductor wire concealed with the all material. |
| 385 | Supply and fixing of exhaust fans of 18\\" size 1450rpm of GEC/equivalent make complete in all respect. |
| 386 | PAINTING |
| 387 | Provision for painting of all the pumps set, main piping and valves, panels etc. installed in the pump house with three coats by enamel paint. |
| 388 | INSTALLATION AND COMMISSIONING |
| 389 | Installation of all 2 pumping plants along with L.T. panels distribution boards, switch gear control panels, starter etc laying & jointing of column pipes, delivery pipes, common header also commissiong of pumping plant. |
| 390 | At CWR ZONE 1 FOR OHT ZONE-3 |
| 391 | PUMPING PLANTSupply of submerged VT/ submerged pumping plant along with suitable motor 415 volt ± 10%, 3phase,50 Hz AC supply with required size and lenghth, Column pipe, Foundation, guide pipe, Auto coupling arrangement if required and other necessary accessories to complete the work, capacity LPM - 850 Head-40 M (both tentative it will be decided as per site condition) |
| 392 | Motor operated sluice valve with actuator complete in all respect- |
| 393 | Electric motor operated sluice valve 100mm dia or suitable size along with actuator for delivery pipe of pump. |
| 394 | Electric motor operated sluice valve 100mm dia or suitable size along with actuator for common header. |
| 395 | Pressure Transmitter with manual pressure gauge at each pump and common header - 3 Nos |
| 396 | Rador type level sensor |
| 397 | ELECTRO MAGNETIC FLOW METER |
| 398 | Provision of Electro magnetic flow meter suitable to meassure the discharge upto 850 lpm and to be fitted in common header of 100 mm dia having following specification complete in all respect. |
| 399 | FLOW SENSOR |
| 400 | Type - Pulsed DC |
| 401 | End connection- Flanged of Carbon steel |
| 402 | Flange rating - PN 16 size 100 mm. |
| 403 | Electrode - SS 316 |
| 404 | Lining Material - Hard rubber |
| 405 | Protection category - IP 68 |
| 406 | Measuring Accuracy- + 5% of measured |
| 407 | Valve inclusive of linearity repeatability pressure effect and Hystrusues between 1 to 3 meter per second. |
| 408 | Sensor Housing - SS 304 with fully welded construction |
| 409 | Connection/ Junction Box - SS 304 |
| 410 | Earthing only grounding rings required |
| 411 | FLOW TANSMITTER CONVERTOR |
| 412 | Type - Micro processor based modular desing |
| 413 | Display - 3 line back lit LDC for indication of actual flow rate forward reverse sum totolizer. |
| 414 | Protection category - IP 65 |
| 415 | Enclosure - DI - Cast Aluminium with poly urethan with glass window. |
| 416 | Programming- Through three key pad as front facia. |
| 417 | Power Supply - 230 volt 50 HZ AC |
| 418 | Cable Gland - ½ NPT |
| 419 | Mounting - Wall mounted |
| 420 | Maximum Sepration - Upto 300 m between sensor and transmeter without any signal boosters. |
| 421 | Terminals - shock-Hazard-protected push lock terminal. |
| 422 | Error Indetification : 0.3, 6/22 MA |
| 423 | Flow Indicator Totalizer - 3½ digit IED display with 6 digit electro mechanical Totalizer. |
| 424 | MAIN PIPING & VALVES INCLUDING COMMON HEADER :- |
| 425 | Size of Delivery of pump 100mm dia or suitable size.Lenght 6.0 Mtr. for each pump. as per site requirement |
| 426 | Size of Common header of 100mm dia or suitable size, length as per site requirement |
| 427 | Supply of following |
| 428 | CI D/F Reflux Valve 100 mm dia or suitable size - 2 Nos. |
| 429 | CI D/F tee 100x100x100 mm dia. or suitable size - 2 Nos. |
| 430 | D/F distance piece 100 mm dia or suitable size. 1.00 m. long - 2 Nos. |
| 431 | D/F distance piece 100 mm dia or suitable size. 1.50 m. long - 2 Nos. |
| 432 | D/F distance piece 100 mm dia. or suitable size 3.00 m. long - 2 Nos. |
| 433 | Dismantling joint 100 mm dia. - 1 Nos. |
| 434 | Dismantling joint 100 mm dia. - 1 No.Reflex valve 100mm dia 1No. |
| 435 | Nut-bolts, bend,rubber packing ( as required) |
| 436 | Any other Item required for proper installation of above pumps. - 1 Job. |
| 437 | CABLE FOR INCOMING PANEL & PUMPS :- |
| 438 | Suitable size P.V.C. Armoured Alluminium conductor cable from outgoing of transformer to L.T. incoming Panel and for power wring of pumping plant. |
| 439 | EARTHING : |
| 440 | Provision for double plate earthing fo2 nos. of electric motors, starters, panels etc. excavation of earthing pit of required size supply and burrying of 600 mm x600 mm size 3mm thick copper earth plate vertically errected for earthing with its top at least 3 meter from ground level completed with 32 mm G.1. perforated pipes and funnel for watering, laying and fetting of earthing strip, CI boxes hinged cover masonary, laying alternate layers of characoal / coak and salt at least 150 mm thick each layer complete in all respect. |
| 441 | PAINTING |
| 442 | Provision for painting of all the pumps set, main piping and valves, panels etc. installed in the pump house with three coats by enamel paint. |
| 443 | INSTALLATION AND COMMISSIONING |
| 444 | Installation of all 2 pumping plants along with L.T. panels distribution boards, switch gear control panels, starter etc laying & jointing of column pipes, delivery pipes, common header also commissiong of pumping plant. |
| 445 | CWR ZONE 1 FOR OHT ZONE-4 |
| 446 | PUMPING PLANTSupply of submerged VT/ submerged pumping plant along with suitable motor 415 volt ± 10%, 3phase,50 Hz AC supply with required size and lenghth, Column pipe, Foundation, guide pipe, Auto coupling arrangement if required and other necessary accessories to complete the work, capacity LPM - 1000 Head-40 M (both tentative it will be decided as per site condition) |
| 447 | Motor operated sluice valve with actuator complete in all respect- |
| 448 | Electric motor operated sluice valve 100mm dia or suitable size along with actuator for delivery pipe of pump. |
| 449 | Electric motor operated sluice valve 100mm dia or suitable size along with actuator for common header-2 Nos |
| 450 | Pressure Transmitter along with manual pressure gauge |
| 451 | Ultrasonic level sensor of 5 mtr. For RTU communication |
| 452 | ELECTRO MAGNETIC FLOW METER |
| 453 | Provision of Electro magnetic flow meter suitable to meassure the discharge upto be fitted in common header of 100 mm dia or suitable size having following specification complete in all respect. |
| 454 | FLOW SENSOR |
| 455 | Type - Pulsed DC |
| 456 | End connection- Flanged of Carbon steel |
| 457 | Flange rating - PN 16 size 100 mm. |
| 458 | Electrode - SS 316 |
| 459 | Lining Material - Hard rubber |
| 460 | Protection category - IP 68 |
| 461 | Measuring Accuracy- + 5% of measured |
| 462 | Valve inclusive of linearity repeatability pressure effect and Hystrusues between 1 to 3 meter per second. |
| 463 | Sensor Housing - SS 304 with fully welded construction |
| 464 | Connection/ Junction Box - SS 304 |
| 465 | Earthing only grounding rings required |
| 466 | FLOW TANSMITTER CONVERTOR |
| 467 | Type - Micro processor based modular desing |
| 468 | Display - 3 line back lit LDC for indication of actual flow rate forward reverse sum totolizer. |
| 469 | Protection category - IP 65 |
| 470 | Enclosure - DI - Cast Aluminium with poly urethan with glass window. |
| 471 | Programming- Through three key pad as front facia. |
| 472 | Power Supply - 230 volt 50 HZ AC |
| 473 | Cable Gland - ½ NPT |
| 474 | Mounting - Wall mounted |
| 475 | Maximum Sepration - Upto 300 m between sensor and transmeter without any signal boosters. |
| 476 | Terminals - shock-Hazard-protected push lock terminal. |
| 477 | Error Indetification : 0.3, 6/22 MA |
| 478 | Flow Indicator Totalizer - 3½ digit IED display with 6 digit electro mechanical Totalizer. |
| 479 | MAIN PIPING & VALVES INCLUDING COMMON HEADER :- |
| 480 | Size of Delivery of pump 100mm dia or suitable size Lenght 6.0 Mtr. for each pump. |
| 481 | Size of Common header of 100mm dia., or suitable size length as per site requirement |
| 482 | Supply of following |
| 483 | CI D/F Reflux Valve 100 mm dia or suitable size - 2 Nos. |
| 484 | CI D/F tee 100x100x100 mm dia. or suitable size - 2 Nos. |
| 485 | D/F distance piece 100 mm dia or suitable size. 1.00 m. long - 2 Nos. |
| 486 | D/F distance piece 100 mm dia. 1.50 m or suitable size. long - 2 Nos. |
| 487 | D/F distance piece 100 mm dia. 3.00 m. or suitable size long - 2 Nos. |
| 488 | Dismantling joint 100 mm dia. or suitable size - 1 Nos. |
| 489 | Dismantling joint 100 mm dia. or suitable size - 1 No.Reflex valve 100mm dia 1No. |
| 490 | Nut-bolts, bend,rubber packing ( as required) |
| 491 | Any other Item required for proper installation of above pumps. - 1 Job. |
| 492 | CABLE FOR INCOMING PANEL & PUMPS :- |
| 493 | Suitable size P.V.C. Armoured Alluminium conductor cable from outgoing of transformer to L.T. incoming Panel and for power wring of pumping plant. |
| 494 | EARTHING : |
| 495 | Provision for double plate earthing fo2 nos. of electric motors, starters, panels etc. excavation of earthing pit of required size supply and burrying of 600 mm x600 mm size 3mm thick copper earth plate vertically errected for earthing with its top at least 3 meter from ground level completed with 32 mm G.1. perforated pipes and funnel for watering, laying and fetting of earthing strip, CI boxes hinged cover masonary, laying alternate layers of characoal / coak and salt at least 150 mm thick each layer complete in all respect. |
| 496 | PAINTING |
| 497 | Provision for painting of all the pumps set, main piping and valves, panels etc. installed in the pump house with three coats by enamel paint. |
| 498 | INSTALLATION AND COMMISSIONING |
| 499 | Installation of all 2 pumping plants along with L.T. panels distribution boards, switch gear control panels, starter etc laying & jointing of column pipes, delivery pipes, common header also commissiong of pumping plant. |
| 500 | DMA Equipment At OHT Zone 1, |
| 501 | Motor operated Actuators with sluice valve for OHT delivery |
| 502 | SITC of plunger type flow control Valve 250 mm or suitable size. |
| 503 | SITC of Double Solenoid Flow control Valve 250 mm or suitable size. |
| 504 | CE & UL certified Radar type level transmitter for OHT |
| 505 | CE/UL Certified pressure Transmitter |
| 506 | SITC of CE & UL certified Electomagnetic Flowmeter for OHT line size 250 mm. dia or suitable size as per size condition. |
| 507 | SITC of CE & UL certified Electomagnetic Flowmeter for OHT line size 200 mm. dia or suitable size as per size condition. |
| 508 | SITC of Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system . |
| 509 | SITC of SCADA Compatible Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-10 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 510 | Coplete cabling of all equipment at OHT including power and control cable. |
| 511 | Installation ,commissioning and testing . |
| 512 | DMA Equipment At OHT Zone -2 |
| 513 | Motor operated Actuators with sluice valve for OHT delivery |
| 514 | SITC of plunger type flow control Valve of suitable size. |
| 515 | CE & UL certified Radar type level transmitter for OHT |
| 516 | CE/UL Certified pressure Transmitter |
| 517 | SITC of CE & UL certified Electomagnetic Flowmeter for OHT line size 200 mm. dia or suitable size as per site condition. |
| 518 | SITC of Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system . |
| 519 | SITC of SCADA Compatible Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-10 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 520 | Complete cabling of all equipment at OHT including power and control cable. |
| 521 | Installation ,commissioning and testing . |
| 522 | DMA Equipment At OHT Zone -3 |
| 523 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations |
| 524 | G.S.M./G.P.R.S. based wireless communication with 4G Modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations, all accessories included with signal enhancer anteena made for pumping plant |
| 525 | Motor operated Actuators with sluice valve for OHT delivery |
| 526 | SITC of plunger type flow control Valve of suitable size. |
| 527 | CE & UL certified Radar type level transmitter for OHT |
| 528 | CE/UL Certified pressure Transmitter |
| 529 | SITC of CE & UL certified Electomagnetic Flowmeter for OHT line size 250 mm. dia. or suitable size |
| 530 | SITC of Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system . |
| 531 | SITC of SCADA Compatible Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-10 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 532 | Coplete cabling of all equipment at OHT including power and control cable. |
| 533 | Installation ,commissioning and testing . |
| 534 | DMA Equipment At OHT Zone -4 |
| 535 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations |
| 536 | G.S.M./G.P.R.S. based wireless communication with 4G Modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations, all accessories included with signal enhancer anteena made for pumping plant |
| 537 | Motor operated Actuators with sluice valve for OHT delivery |
| 538 | SITC of plunger type flow control Valve of suitable size. |
| 539 | CE & UL certified Radar type level transmitter for OHT |
| 540 | CE/UL Certified pressure Transmitter |
| 541 | SITC of CE & UL certified Electomagnetic Flowmeter for OHT line size 250 mm. dia. or suitable size |
| 542 | SITC of Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system . |
| 543 | SITC of SCADA Compatible Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-10 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 544 | Coplete cabling of all equipment at OHT including power and control cable. |
| 545 | Installation ,commissioning and testing . |
| 546 | Master Control Station (MCS) |
| 547 | CE & BIS approved manufacturer's industrial grade LCD monitor with latest configuration as per specification of size 65\\" |
| 548 | Desktop/PC with i7 processor for as per spec mentioned in technical bid documents. |
| 549 | CE/UL approved manufacturer's 3 KVA UPS with batteries as spec. mentioned for WTP and Computer as per requirement |
| 550 | Full development version of required TAGS SCADA Software with costomization of software for MCS as per required as per spec mentioned in technical bid documents. |
| 551 | CE & UL approved manufacturer's control room PLC with CPU & power supply at MCS in IP65 enclosure as per spec. mentioned |
| 552 | CE/UL certified field gateway agent for transfering data from MCS to control room |
| 553 | GSM based wireless / broadband/Equipment communication system for PLC capable to transfer and gather data from remote sites to control stations, including all accessories complete |
| 554 | CE/UL approved manufacturer's Firewall for network protection |
| 555 | Lightning surge protector for ethernet communication protection |
| 556 | CE/UL approved manufacturer's industrial grade ethernet switch |
| 557 | Mobile App facility system architecture complete. |
| 558 | Supply and Installation 1.5 Ton AC with stabilizer and other required item for installation |
| 559 | Canon/HP 1018/equivalent Laser printer with chair and table. |
| 560 | Security Survelliance IP camera |
| 561 | Installation, testing and commissioning with required furniture,Air Conditioner etc |
| 562 | Test and trial run |
| 563 | Sub station at Intake well |
| 564 | HT Control Panel |
| 565 | 2mm thick M.S. sheet fabricated factory wired dust and vermin proof cubical and floor mounting type SCADA Compatible control panel comprising of following items. |
| 566 | Incoming panel-1No. |
| 567 | 11 KV/800 Amp. 3 Phase 3 wire 50 Hz. HT incoming panel with a short circuit breaking current up to 18.4 KVA capacity in draw out version vaccum circuit breaker fitted with- |
| 568 | 3 Nos. single phase double core epoxy bar primary time current transformer of suitable ratio of class I accuracy and 5p 10 for protection core with burden of 15 VA per core. |
| 569 | 1 no. 3 phase resin cast draw out type PT of ratio 11 KV/110 volt of class I accuracy and 100 VA burden. |
| 570 | 1 set of closing & tripping coil suitable for 30 Volt DC. |
| 571 | Mechanical indicator for ON/OFF. |
| 572 | Emergency Mechanical tripping through push lever. |
| 573 | Rear/Side entry cable box to accommodate suitable size cable. |
| 574 | Energy Analyzer of measuring parameters such as voltage, current, KW, KWH, KVA & Power factor. |
| 575 | Indicating lamp assembly for breaker ON/OFF trapping spring, charge. |
| 576 | Over current and earth fault relay, C.D.G. 31 having elements for over current and one for earth fault etc. |
| 577 | Incoming panel will be followed by a battery charge unit having specification as under |
| 578 | The Cabinet of Suitable thickness shall be enclosed type to ensure the atmosphere is absolutely acid free. It shall be provided with cover for ventilation and shall have steel hinged doors equiped with battery & battery charger. |
| 579 | Outgoing panel 2 No. |
| 580 | H.T. out going panels for feeding two transformers of suitable capacity similar to incoming panel but without following accessories. |
| 581 | Volt meter with selector switch |
| 582 | KWH meter with M.D.I. |
| 583 | Potential transformers |
| 584 | Outgoing battery charger |
| 585 | Provision for oil immersed natural air cooled step down transformer suitable for out door installation of 100 KVA or suitable size as per design in best engineering manner. 11/0.4KV and as per I:S 2020/1972 with all accessories. The transformer should be provided with off load tap changer ± 7.5% voltage varialtion on L.T. side. These tapping should be connected by and externally separated tap changing switch. The temp side in oil by thermometer should not exceed 50oC and of winding by measuring resistance should not exceed 55oC over an ambient of 45oC maximum. The transformer should have cable box on HT/LT side for termination of cables. |
| 586 | Main L.T. Panel with APFC PANNEL |
| 587 | 2mm thick M.S. sheet fabricated factory wired dust and vermin proof cubical and floor mounting type control panel comprising of following items. |
| 588 | Incoming Panel-2No.For Transformer and 1 No. DG |
| 589 | Reputed make cubical floor mounting extensible type panel complete with T.P. air insulated aluminium Bus bar of suitable size with neutral of reduced section, system voltage 415/440 volts 3 phase 4 wire 50 Hz indoor installation type and comprising of suitable size T.P. M.C.C.B. housed in sheet steel cubical panel fitted with following. |
| 590 | One set of Mechanical On/Off Indicator |
| 591 | One no. shunt trip oil |
| 592 | One set of T.P.I.D. M.T. Non-directional combined over current and earth fault relay having setting 50-200% for over current and 20-80% for earth fault or equivalent. |
| 593 | Two CTs of suitable ratio and class for protection and indication. |
| 594 | One no. neutral link |
| 595 | One no. 96 Sq.mm. voltmeter (0-600) selector switch |
| 596 | One no. three way and off voltmeter selector switch |
| 597 | One no. 96 Sq.mm. Ammeter of and suitable range |
| 598 | One no. three way and off Ammeter selector switch |
| 599 | One set of red green indicating lamp |
| 600 | Cable connection arrangments |
| 601 | Suaitable size APFC pannel for maintaning power factor and Inter locking arrangements. |
| 602 | Required No. of Soft starter/VFD Of suitable Size |
| 603 | Bus coupler |
| 604 | Bus coupler complete with internal wiring aluminium bus bar comprising of following. |
| 605 | Extensible type 630 Amp or suitable Capacity Aluminium bus bar arrangement for phase and neutical |
| 606 | 600 Amp. or suitable size 3 pole M.C.C.B. fitted with over load under voltage shunt trip short circuit release with safety shutter etc. for pumps and spare MCCB - 2 Nos. |
| 607 | Ampere meter of suitable range with selector switch and CT's |
| 608 | Voltmeter (0-600) volt with selector |
| 609 | Electrical and mechanical inter locking arrangement |
| 610 | M.C.C.B On/Off indicating lamp. |
| 611 | HRC Fuses |
| 612 | Auxilliary contractors |
| 613 | Breaker control switch |
| 614 | Load Distribution Panel |
| 615 | Floor mounting extensible type with common aluminium bus bar of suitable capacity arrangement comprising of M.C.C.B./M.C.B. suitable C.Ts operated ampere meter, On/Off indicator selector switch and internal wiring etc. complete including Ampere meter, Volt meter, frequency meter, P.F. meter, capacitor, single phasing preventer, Selector switch, fuses, etc as per required no. & suitable size of MCB |
| 616 | Supply and laying of cable |
| 617 | Supply of 11 KV XLPE cable 3 x 70mm sq./ suitable size |
| 618 | Supply of 3.50 core 185 Sq.mm /suitable size aluminium PVC cable 1100 V grade. |
| 619 | Supply of Jointing cable |
| 620 | i) HT Indoor joint |
| 621 | ii) HT outdoor joint |
| 622 | Supply of earthing materials and earthing arrangement. |
| 623 | Erection, testing and commissioning of Sub-Station including testing at work also. |
| 624 | Approval of electrical inspector, electric safety. |
| 625 | Foundation & bolder for Transformers |
| 626 | 25 thick electric resistance rubber sheet as per BIS |
| 627 | Fencing work |
| 628 | Internal Electrification with concealed conduct wiring including all materials and labour complete in all respect of controlling room and staff Quarter. |
| 629 | Sub station at WTP for WTP and main CWR. |
| 630 | HT Control Panel |
| 631 | 2mm thick M.S. sheet fabricated factory wired dust and vermin proof cubical and floor mounting type SCADA Compatible control panel comprising of following items. |
| 632 | Incoming panel-1 No. |
| 633 | 11 KV/800 Amp. 3 Phase 3 wire 50 Hz. HT incoming panel with a short circuit breaking current up to 18.4 KVA capacity in draw out version vaccum circuit breaker fitted with- |
| 634 | 3 Nos. single phase double core epoxy bar primary time current transformer of suitable ratio of class I accuracy and 5p 10 for protection core with burden of 15 VA per core. |
| 635 | 1 no. 3 phase resin cast draw out type PT of ratio 11 KV/110 volt of class I accuracy and 100 VA burden. |
| 636 | 1 set of closing & tripping coil suitable for 30 Volt DC. |
| 637 | Mechanical indicator for ON/OFF. |
| 638 | Emergency Mechanical tripping through push lever. |
| 639 | Rear/Side entry cable box to accommodate suitable size cable. |
| 640 | Energy Analyzer of measuring parameters such as voltage, current, KW, KWH, KVA & Power factor. |
| 641 | Indicating lamp assembly for breaker ON/OFF trapping spring, charge. |
| 642 | Over current and earth fault relay, C.D.G. 31 having elements for over current and one for earth fault etc. |
| 643 | Incoming panel will be followed by a battery charge unit having specification as under |
| 644 | The Cabinet of Suitable thickness shall be enclosed type to ensure the atmosphere is absolutely acid free. It shall be provided with cover for ventilation and shall have steel hinged doors equiped with battery & battery charger. |
| 645 | Outgoing panel-2No |
| 646 | H.T. out going panels for feeding two transformers of similar to incoming panel but without following accessories. |
| 647 | Volt meter with selector switch |
| 648 | KWH meter with M.D.I. |
| 649 | Potential transformers |
| 650 | Outgoing battery charger |
| 651 | Provision for oil immersed natural air cooled step down transformer suitable for out door installation of 200 KVA or higher as per site requirement and design in best engineering manner., 11/0.4KV and as per I:S 2020/1972 with all accessories. The transformer should be provided with off load tap changer ± 7.5% voltage varialtion on L.T. side. These tapping should be connected by and externally separated tap changing switch. The temp side in oil by thermometer should not exceed 50oC and of winding by measuring resistance should not exceed 55oC over an ambient of 45oC maximum. The transformer should have cable box on HT/LT side for termination of cables. |
| 652 | Main L.T. Panel with APFC PANNEL |
| 653 | 2mm thick M.S. sheet fabricated factory wired dust and vermin proof cubical and floor mounting type control panel comprising of following items. |
| 654 | Incoming Panel- 2 No For Transformer and 1 No. DG |
| 655 | Reputed make cubical floor mounting extensible type panel complete with T.P. air insulated aluminium Bus bar of 800 Amp. or suitable size with neutral of reduced section, system voltage 415/440 volts 3 phase 4 wire 50 Hz indoor installation type and comprising of 630 Amp. T.P. M.C.C.B. housed in sheet steel cubical panel fitted with following. |
| 656 | One set of Mechanical On/Off Indicator |
| 657 | One no. shunt trip oil |
| 658 | One set of T.P.I.D. M.T. Non-directional combined over current and earth fault relay having setting 50-200% for over current and 20-80% for earth fault or equivalent. |
| 659 | Two CTs of suitable ratio and class for protection and indication. |
| 660 | One no. neutral link |
| 661 | One no. 96 Sq.mm. voltmeter (0-600) selector switch |
| 662 | One no. three way and off voltmeter selector switch |
| 663 | One no. 96 Sq.mm. Ammeter of and suitable range |
| 664 | One no. three way and off Ammeter selector switch |
| 665 | One set of red green indicating lamp |
| 666 | Cable connection arrangments |
| 667 | Suaitable size APFC pannel for maintaning power factor and Inter locking arrangements. |
| 668 | Required No. of Soft starter/VFD Of suitable Size |
| 669 | Bus coupler |
| 670 | Bus coupler complete with internal wiring aluminium bus bar comprising of following. |
| 671 | Extensible type suitable Capacity Aluminium bus bar arrangement for phase and neutical |
| 672 | suitable 3 pole M.C.C.B. fitted with over load under voltage shunt trip short circuit release with safety shutter etc. |
| 673 | Ampere meter of suitable range with selector switch and CT's |
| 674 | Voltmeter (0-600) volt with selector |
| 675 | Electrical and mechanical inter locking arrangement |
| 676 | M.C.C.B On/Off indicating lamp. |
| 677 | HRC Fuses |
| 678 | Auxilliary contractors |
| 679 | Breaker control switch |
| 680 | Load Distribution Panel |
| 681 | Floor mounting extensible type with common aluminium bus bar of suitable capacity arrangement comprising of M.C.C.B./M.C.B. suitable C.Ts operated ampere meter, On/Off indicator selector switch and internal wiring etc. complete including Ampere meter, Volt meter, frequency meter, P.F. meter, capacitor, single phasing preventer, Selector switch, fuses, etc with as required suitable capacity & No. of MCB . |
| 682 | Supply and laying of cable |
| 683 | Supply of 11 KV XLPE cable 3 x 70mm sq./ suitable size |
| 684 | Supply of 3.50 core 185 Sq.mm /suitable size aluminium PVC cable 1100 V grade. |
| 685 | Supply of Jointing cable |
| 686 | i) HT Indoor joint |
| 687 | ii) HT outdoor joint |
| 688 | Supply of earthing materials and earthing arrangement. |
| 689 | Erection, testing and commissioning of Sub-Station including testing at work also. |
| 690 | Approval of electrical inspector, electric safety. |
| 691 | Foundation and bolder for Transformers |
| 692 | 25mm thick electric resistance rubber sheet as per BIS |
| 693 | Fencing work |
| 694 | Internal Electrification with concealed conduct wiring including all materials and labour complete in all respect of controlling room and staff Quarter. |
| 695 | Sub station at Zone -1 |
| 696 | HT Control Panel |
| 697 | 2mm thick M.S. sheet fabricated factory wired dust and vermin proof cubical and floor mounting type SCADA Compatible control panel comprising of following items. |
| 698 | Incoming panel-1No |
| 699 | 11 KV/800 Amp. 3 Phase 3 wire 50 Hz. HT incoming panel with a short circuit breaking current up to 18.4 KVA capacity in draw out version vaccum circuit breaker fitted with- |
| 700 | 3 Nos. single phase double core epoxy bar primary time current transformer of suitable ratio of class I accuracy and 5p 10 for protection core with burden of 15 VA per core. |
| 701 | 1 no. 3 phase resin cast draw out type PT of ratio 11 KV/110 volt of class I accuracy and 100 VA burden. |
| 702 | 1 set of closing & tripping coil suitable for 30 Volt DC. |
| 703 | Mechanical indicator for ON/OFF. |
| 704 | Emergency Mechanical tripping through push lever. |
| 705 | Rear/Side entry cable box to accommodate suitable size cable. |
| 706 | Energy Analyzer of measuring parameters such as voltage, current, KW, KWH, KVA & Power factor. |
| 707 | Indicating lamp assembly for breaker ON/OFF trapping spring, charge. |
| 708 | Over current and earth fault relay, C.D.G. 31 having elements for over current and one for earth fault etc. |
| 709 | Incoming panel will be followed by a battery charge unit having specification as under |
| 710 | The Cabinet of Suitable thickness shall be enclosed type to ensure the atmosphere is absolutely acid free. It shall be provided with cover for ventilation and shall have steel hinged doors equiped with battery & battery charger. |
| 711 | Outgoing panel- 2 No |
| 712 | H.T. out going panels for feeding two transformers of similar to incoming panel but without following accessories. |
| 713 | Volt meter with selector switch |
| 714 | KWH meter with M.D.I. |
| 715 | Potential transformers |
| 716 | Outgoing battery charger |
| 717 | Provision for oil immersed natural air cooled step down transformer suitable for out door installation of 160 KVA or suitable as per size condition and design and best engineering manner, 11/0.4KV and as per I:S 2020/1972 with all accessories. The transformer should be provided with off load tap changer ± 7.5% voltage varialtion on L.T. side. These tapping should be connected by and externally separated tap changing switch. The temp side in oil by thermometer should not exceed 50oC and of winding by measuring resistance should not exceed 55oC over an ambient of 45oC maximum. The transformer should have cable box on HT/LT side for termination of cables. |
| 718 | Main L.T. Panel WITH APFC PANNEL |
| 719 | 2mm thick M.S. sheet fabricated factory wired dust and vermin proof cubical and floor mounting type control panel comprising of following items. |
| 720 | Incoming Panel-2No.For Transformer and 1 No. DG |
| 721 | Reputed make cubical floor mounting extensible type panel complete with T.P. air insulated aluminium Bus bar of 1000 Amp or suitable capacity. with neutral of reduced section, system voltage 415/440 volts 3 phase 4 wire 50 Hz indoor installation type and comprising of 630 Amp. T.P. M.C.C.B. housed in sheet steel cubical panel fitted with following. |
| 722 | One set of Mechanical On/Off Indicator |
| 723 | One no. shunt trip oil |
| 724 | One set of T.P.I.D. M.T. Non-directional combined over current and earth fault relay having setting 50-200% for over current and 20-80% for earth fault or equivalent. |
| 725 | Two CTs of suitable ratio and class for protection and indication. |
| 726 | One no. neutral link |
| 727 | One no. 96 Sq.mm. voltmeter (0-600) selector switch |
| 728 | One no. three way and off voltmeter selector switch |
| 729 | One no. 96 Sq.mm. Ammeter of and suitable range |
| 730 | One no. three way and off Ammeter selector switch |
| 731 | One set of red green indicating lamp |
| 732 | Cable connection arrangments |
| 733 | Suitable size of APFC pannel to maintaning power factor and Inter locking arrangements |
| 734 | Required No. of Soft starter/VFD Of suitable Size |
| 735 | Bus coupler |
| 736 | Bus coupler complete with internal wiring aluminium bus bar comprising of following. |
| 737 | Extensible type suitable. Capacity Aluminium bus bar arrangement for phase and neutical |
| 738 | suitable 3 pole M.C.C.B. fitted with over load under voltage shunt trip short circuit release with safety shutter etc. |
| 739 | Ampere meter of suitable range with selector switch and CT's |
| 740 | Voltmeter (0-600) volt with selector |
| 741 | Electrical and mechanical inter locking arrangement |
| 742 | M.C.C.B On/Off indicating lamp. |
| 743 | HRC Fuses |
| 744 | Auxilliary contractors |
| 745 | Breaker control switch |
| 746 | Load Distribution Panel |
| 747 | Floor mounting extensible type with common aluminium bus bar of suitable capacity . arrangement comprising of M.C.C.B./M.C.B. suitable C.Ts operated ampere meter, On/Off indicator selector switch and internal wiring etc. complete including Ampere meter, Volt meter, frequency meter, P.F. meter, capacitor, single phasing preventer, Selector switch, fuses and required no. and suitable size of MCB . |
| 748 | Supply and laying of cable |
| 749 | Supply of 11 KV XLPE cable . 3 x 70mm sq./ suitable size |
| 750 | Supply of 3.50 core 120 Sq.mm /suitable size aluminium PVC cable 1100 V grade. |
| 751 | Supply of Jointing cable |
| 752 | i) HT Indoor joint |
| 753 | ii) HT outdoor joint |
| 754 | Supply of earthing materials and earthing arrangement. |
| 755 | Erection, testing and commissioning of Sub-Station including testing at work also. |
| 756 | Approval of electrical inspector, electric safety. |
| 757 | Foundation and bolder for Transformers |
| 758 | 25mm thick electric resistance rubber sheet as per BIS |
| 759 | Fencing work |
| 760 | Internal Electrification with concealed conduct wiring including all materials and labour complete in all respect of controlling room and staff Quarter. |
| 761 | DIESEL GENERATING SET AT INTAKE WELL |
| 762 | Provision for supply Installation,Testing and commissing of salient type suitable capacity DG set as per C.P.C.B. Latest guide line powered with complete in all respect- |
| 763 | Deiesel Engine ( goverining as per BS - 5114) |
| 764 | Type- Vertical |
| 765 | RPM- 1500 |
| 766 | Method of coolling- Radiator |
| 767 | Method of aspiration- Turbo charged after . cooled |
| 768 | Method of Starting- 24 Volt Electric |
| 769 | Alternator |
| 770 | 3 phase, 50 C/S, self regulated, self excited, Screen protected, 415 volts 4 wire alternator of rated capacity at 0.8 power factor. The alternator would generally confirm to relevant BS/IS standard. |
| 771 | Base Plate |
| 772 | The above diesel engine will be directly coupled alternator through a flexible coupling on a sturdy channel section steel base frame. |
| 773 | Control Panel |
| 774 | The control panel will be dust and varmin proof of sheet metal construction, floor mounting type, suitable for indoor use in IP-41 enclosure. The control panel will comprise of - |
| 775 | A.C. voltmeter with selector switch |
| 776 | A.C. Ampermeter with selector switch |
| 777 | Frequency meter |
| 778 | K.W.A. meter |
| 779 | Kilowatt meter |
| 780 | MCCB with overload, shart cercuit and under voltage protection. |
| 781 | Starting push button and Key switch ( ON/OFF) |
| 782 | Audio/Visual alarm with shut down for engine protection for low oil pressure and high coolant temperature. |
| 783 | Indicating lamps for low lub-oil pressure, high coolant temperature, set running and load on set be control on. |
| 784 | Instrument fuses. |
| 785 | 1.5 class CTs of suitable ratio. |
| 786 | Bus bars- Alumimum. |
| 787 | Cable entry gland plate without cable gland |
| 788 | Power cable of 150 sqmm size/suitable size of 1100 volts grade 3½ core Alluminium armoured PVC seathed |
| 789 | DIESEL GENERATING SET AT WTP AND MAIN CWR |
| 790 | Provision for supply Installation,Testing and commissing of salient type suitable rating DG set as per C.P.C.B. Latest guide line powered with complete in all respect- |
| 791 | Deiesel Engine ( goverining as per BS - 5114) |
| 792 | Type- Vertical |
| 793 | RPM- 1500 |
| 794 | Method of coolling- Radiator |
| 795 | Method of aspiration- Turbo charged after . cooled |
| 796 | Method of Starting- 24 Volt Electric |
| 797 | Alternator |
| 798 | 3 phase, 50 C/S, self regulated, self excited, Screen protected, 415 volts 4 wire alternator of rated capacity at 0.8 power factor. The alternator would generally confirm to relevant BS/IS standard. |
| 799 | Base Plate |
| 800 | The above diesel engine will be directly coupled alternator through a flexible coupling on a sturdy channel section steel base frame. |
| 801 | Control Panel |
| 802 | The control panel will be dust and varmin proof of sheet metal construction, floor mounting type, suitable for indoor use in IP-41 enclosure. The control panel will comprise of - |
| 803 | A.C. voltmeter with selector switch |
| 804 | A.C. Ampermeter with selector switch |
| 805 | Frequency meter |
| 806 | K.W.A. meter |
| 807 | Kilowatt meter |
| 808 | MCCB with overload, shart cercuit and under voltage protection. |
| 809 | Starting push button and Key switch ( ON/OFF) |
| 810 | Audio/Visual alarm with shut down for engine protection for low oil pressure and high coolant temperature. |
| 811 | Indicating lamps for low lub-oil pressure, high coolant temperature, set running and load on set be control on. |
| 812 | Instrument fuses. |
| 813 | 1.5 class CTs of suitable ratio. |
| 814 | Bus bars- Alumimum. |
| 815 | Cable entry gland plate without cable gland |
| 816 | Power cable of 185 sqmm size/suitable size of 1100 volts grade 3½ core Alluminium armoured PVC seathed |
| 817 | DIESEL GENERATING SET AT Zone -1 CWR |
| 818 | Provision for supply Installation,Testing and commissing of salient type suitable rating DG set as per C.P.C.B. Latest guide line powered with complete in all respect- |
| 819 | Deiesel Engine ( goverining as per BS - 5114) |
| 820 | Type- Vertical |
| 821 | RPM- 1500 |
| 822 | Method of coolling- Radiator |
| 823 | Method of aspiration- Turbo charged after . cooled |
| 824 | Method of Starting- 24 Volt Electric |
| 825 | Alternator |
| 826 | 3 phase, 50 C/S, self regulated, self excited, Screen protected, 415 volts 4 wire alternator of rated capacity at 0.8 power factor. The alternator would generally confirm to relevant BS/IS standard. |
| 827 | Base Plate |
| 828 | The above diesel engine will be directly coupled alternator through a flexible coupling on a sturdy channel section steel base frame. |
| 829 | Control Panel |
| 830 | The control panel will be dust and varmin proof of sheet metal construction, floor mounting type, suitable for indoor use in IP-41 enclosure. The control panel will comprise of - |
| 831 | A.C. voltmeter with selector switch |
| 832 | A.C. Ampermeter with selector switch |
| 833 | Frequency meter |
| 834 | K.W.A. meter |
| 835 | Kilowatt meter |
| 836 | MCCB with overload, shart cercuit and under voltage protection. |
| 837 | Starting push button and Key switch ( ON/OFF) |
| 838 | Audio/Visual alarm with shut down for engine protection for low oil pressure and high coolant temperature. |
| 839 | Indicating lamps for low lub-oil pressure, high coolant temperature, set running and load on set be control on. |
| 840 | Instrument fuses. |
| 841 | 1.5 class CTs of suitable ratio. |
| 842 | Bus bars- Alumimum. |
| 843 | Cable entry gland plate without cable gland |
| 844 | Power cable of 150 sqmm size/suitable size of 1100 volts grade 3½ core Alluminium armoured PVC seathed |
| 845 | Investigation,design ,planning with supply installation ,testing of all material labour etc.For 7.0 MLD WTP -Agitator, flash mixer, Air Blower, Centrifuge system, Per /post chlorination system, back wash pump, dirty back wash recycle pump, filter media, filter nozzel,gates and valve with actuators, flow meter, sludge thickener, pipe and fitting, PAC and Poly pump,Thickner feed pump,Sludge feed pump, PLC, SCADA, UPS for all zonal OHTs, ,MCS ,Power and control cable, tray, lug ,gland, electrical pannel,LDB,CCTV setup, Repudiated make Computer sets with CPU] Monitor, Printer and Photo copy machine for Prayagraj office for (Monitoring of WTP and Zonal pumping station from Scada) annalazer,lavel switch, indicator ,iron clad, Indoor and out door lighting system with solar system of 5 KW etc. for 7.0 MLD WTP. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail